Spelling suggestions: "subject:"refrigeration"" "subject:"regrigeration""
1 |
Analise energetica e exergetica de um ciclo de refrigeração por compressão de vapor utilizando HC290 em substituição ao HCFC22 / Energetic and exergetic analysis of a vapor compression refrigeration system operating with HC290 as an alternative to HCFC22Arini, Ricardo Greber 12 August 2018 (has links)
Orientador: Arai Augusta Bernardez Pecora / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T19:26:31Z (GMT). No. of bitstreams: 1
Arini_RicardoGreber_M.pdf: 5502572 bytes, checksum: c19e6a830ce67a88c8959a10cd21aef8 (MD5)
Previous issue date: 2008 / Resumo: Este trabalho teve como objetivo analisar experimentalmente um sistema de refrigeração por compressão de vapor operando com o hidrocarboneto propano (R290) em substituição ao refrigerante HCFC22, visando atender as necessidades do mercado atual de refrigeração comercial, que busca alternativas que atendam à exigência de substituição gradual dos refrigerantes hidroclorofluorcarbonados (HCFC's). O estudo foi realizado em um mini-tanque de resfriamento de leite, produzido comercialmente para operar com o refrigerante 22. Foram analisadas as influências da temperatura do fluido no interior do tanque e da temperatura do ar de resfriamento do condensador sobre parâmetros de desempenho do ciclo de compressão como: pressão de condensação, pressão de evaporação, coeficiente de desempenho, efeito frigorífico, trabalho de compressão, taxa específica de transferência de calor no condensador, temperatura do refrigerante na descarga do compressor e volume específico do refrigerante na aspiração do compressor. Além da análise energética, este trabalho apresenta a análise exergética do ciclo operando com R290 em comparação com o ciclo operando com R22. As medidas experimentais foram realizadas em condições de regime permanente, verificado quando não se observaram variações significativas na temperatura do refrigerante em diversos pontos do ciclo. A temperatura do fluido do tanque e a temperatura do ar de resfriamento do condensador foram mantidas constantes através de resistências elétricas imersas na água contida no tanque e na entrada do condensador, respectivamente. A análise de resultados mostrou que é possível a substituição do refrigerante R22 pelo R290 no sistema estudado, sendo observado que o sistema operando com R290 apresentou desempenho energético equivalente ao apresentado pelo R22. Foi verificado que a eficiência exergética do sistema operando com R290 foi igual ou superior à obtida com R22. Observou-se ainda um menor consumo de energia elétrica pelo sistema nos testes de resfriamento utilizando propano como refrigerante. / Abstract: In order to meet the requirements of the commercial refrigeration market, which demands for alternatives to substitute gradually the use of refrigerants such as hydroclorofluorcarbons (HCFC's), this research had the aim to analyze experimentally a mechanical vapor-compression refrigeration system operating with hydrocarbon propane (R290) as an alternative for R22. This study was made in a small tank for milk refrigeration, commercially built to operate with the refrigerant HCFC22. It was analyzed the influences of the factors: temperature of the water inside the tank and temperature of the cooling air at the entrance of the condenser, on the performance of the compression cycle. The following parameters were determined: evaporating pressure, condensing pressure, coefficient of performance, refrigeration capacity per unit mass of refrigerant flow, compression work, rate of heat transfer per unit mass of refrigerant flow at the condenser, refrigerant discharge temperature at the compressor outlet and specific volume of the refrigerant at the compressor inlet. In order to verify which refrigerant fluid realizes the best usage of the available work, it was made, besides an energetic analysis, a comparative exergetic analysis of the cycles. The experimental measures were made at steady state conditions, verified when no significant variations of refrigerant temperatures in several parts of the cycle were observed. The water temperature inside the tank and the air temperature, at the entrance of the condenser, were kept constant by using electrical resistances. The analysis of the results showed that R290 could be used as a substitute for R 22 to the studied system. It was observed that the energetic performance of the system working with R290 was better than the obtained using R22. The exergetic efficiency of the system using R290 was equal or greater than that obtained using R22. A less electrical energy consumption was obtained in the cooling experiments using R290 as refrigerant. / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
|
2 |
Criopreservação de sêmen de galos / Roosters sperm cryopreservationLaan, Guilherme Martino Van Der 30 November 2007 (has links)
Made available in DSpace on 2014-08-20T13:32:51Z (GMT). No. of bitstreams: 1
dissertacao_guilherme_van_der_laan.pdf: 723829 bytes, checksum: 399e8e1ec5f5ec9b7f77f1ffa1d0af80 (MD5)
Previous issue date: 2007-11-30 / Adding extenders to poultry semen is currently used in artificial insemination
programs to optimize the management of genetically superior males. Fresh semen
fertility usually declines after 1 hour of collection, raising the need to use diluents and
low temperatures to store semen for longer periods. Low density lipoprotein (LDL),
extracted from the egg yolk, is used as a component of various mammalian semen
diluents, however its application on poultry semen has not been evaluated.
Regarding cryopreservation, different methodologies have been developed during
the past years. One alternative is to use dimethylacetamide (DMA) as a
cryoprotectant. The best results with DMA are obtained when semen is subjected to
ultra-fast freezing, in pellets, and to a fast thawing at 60ºC. The objective of this work
was to establish protocols to preserve rooster sperm, focusing on the use of LDL as
a component of the refrigeration diluent, and on DMA as a internal cryoprotectant for
freezing. To reach these objectives, the effect of adding different levels of LDL
liposomes to the cooling diluent, upon the quality characteristics of semen
refrigerated at 5 °C, was evaluated. The quality of semen frozen with DMA, packed
in straws or pellets, and thawed in three different temperatures was also evaluated.
The results obtained allow to conclude that: adding 6% of LDL liposomes to the
cooling diluent preserves the general sperm quality, suggesting that improvements
on fertility could be obtained if a limit in lipoprotein supplementation is imposed; body
temperature (40°C) is most suitable for thawing sperm frozem with DMA; and packing
sperm in straws is more efficient than packing in pellets. This last observation is of
great value, since storing semen in straws is more appropriate due to sanitary
reasons, and more convenient for ejaculates identification, especially for field
application of genetic banks. / A adição de diluentes ao sêmen de aves é uma prática rotineiramente
empregada em programas de inseminação artificial para melhorar o manejo de
machos geneticamente superiores. A fertilidade do sêmen fresco normalmente decai
1 hora após a coleta, por isso a necessidade do uso de diluentes e temperaturas
hipotérmicas para o armazenamento do sêmen por períodos mais prolongados. A
Lipoproteína de Baixa Densidade (LDL), extraída da gema de ovo, tem sido utilizada
na composição de diversos diluentes de sêmen para mamíferos, porém, ainda não
tinha sido avaliada a sua aplicação em diluentes de resfriamento para sêmen de
aves. Em relação ao congelamento, diversos métodos foram desenvolvidos ao longo
dos anos. Uma das alternativas é o uso da Dimetilacetamida (DMA) como
crioprotetor. Os melhores resultados obtidos com DMA ocorrem quando o sêmen é
submetido ao congelamento ultra-rápido na forma de pellets e a um rápido
descongelamento à 60ºC. O objetivo deste trabalho foi o estabelecimento de
protocolos de preservação de sêmen de galos, enfocando o uso de Lipoproteínas de
Baixa Densidade (LDL) como um componente do diluente para resfriamento, e a
Dimetilacetamida (DMA) como crioprotetor interno para o congelamento. Para isto,
foi verificado o efeito da adição de diferentes níveis de lipossomas de LDL na
composição do diluente de resfriamento, sobre as características de qualidade do
sêmen resfriado à 5 °C. Também foi avaliada a qualidade do sêmen congelado
utilizando DMA como crioprotetor, envasado em palhetas ou pellets, e
descongelados em três diferentes temperaturas. Os resultados obtidos nestes
estudos nos permitiram concluir que: a adição de lipossomas de LDL ao diluente de
resfriamento mantém a qualidade geral dos espermatozóides quando adicionado na
proporção de 6%; sugerindo que melhorias na fertilidade podem ser obtidas desde
que seja respeitado um limite de adição desta lipoproteína ao diluente; a
temperatura corporal (40°C) foi a mais apropriada para descongelamento de sêmen
criopreservado com DMA; e ainda, o envase em palhetas é mais eficiente em
relação ao pellet. Esta última observação é de grande valor, visto que o
armazenamento do sêmen em palhetas é mais adequado por razões sanitárias, e
mais conveniente para a identificação dos ejaculados, especialmente para a
aplicação a campo de bancos genéticos.
|
Page generated in 0.0768 seconds