Spelling suggestions: "subject:"resin modified class ionomer""
1 |
The colour stability of various glass ionomer cementsKarjiker, Farzana January 2019 (has links)
>Magister Scientiae - MSc / Introduction: Together with bonding to both enamel and dentine, an ideal restorative material would display physical properties similar to that of natural tooth tissue and would not be prone to degradation as a result of the oral environment. This includes changes in colour. Glass ionomer technology has undergone many changes to its original chemistry since it was developed in the early 1970’s. In 1988 resin-modified glass ionomers were introduced and in 2008, nano-ionomers were introduced. As a result of the progression in material sciences and the use of more sophisticated techniques and methods in restorative dentistry, it is possible to accomplish much improved aesthetics and functional durability of a restoration, both anteriorly and posteriorly. However, for as long as aesthetic restorations have been available, and in spite of advances in material structure and performance, one of the greatest challenges facing clinicians still remains that aesthetic restorations have to be replaced relatively frequently as staining and discolouration is a common problem. Aim of the study: The aim of this study was to determine the stainability of four resin-modified glass ionomers and one glass ionomer cement when exposed to a staining broth. Objectives: To record any change in colour before and after exposing the sample with the staining broth using a spectrophotometer, to compare the stainability, to examine the depth of staining using a light microscope and to observe the particle size of the powder and the surface texture using Scanning Electron Microscopy of the four resin- modified glass ionomer cements and one glass ionomer cement. Materials and Methods: Four resin-modified glass ionomers (one nano-ionomer) and one glass ionomer (zinc-reinforced ionomer) were selected. All were shade A2, except for Vitremer™ which was not available in A2. 15 discs of each material were prepared. The discs were 15 mm in diameter and 2 mm in thickness. All the materials were handled and cured according to the manufacturers’ instructions. After curing, only one side of each disc was polished using Sof-Lex™ discs (3M ESPE, USA). The unpolished side of each disc was designated as a matrix finish. The specimens were all immersed in distilled water at 37 °C for one week. They were then immersed in a staining broth for a period of one week and readings were taken after a period of 2 hours, 4 hours, 8 hours, 24 hours and one week. Colour was read on each side of each disc at the indicated intervals with a spectrophotometer. The colour difference was calculated using the CIELAB colour co-ordinates. Sample discs were then sectioned to determine the depth of staining. An additional sample disc of each material was made for observation with the SEM and was therefore not stained. Also, an unmixed sample of each material was prepared for examination with the SEM. Results: In general, for all materials there was an increase in staining when assessed with the colour difference between the baseline colour and the 7 day reading. Ketac™ N100, showed the highest total colour change of 43.84 for the unpolished surface followed by Riva™ which showed the total colour change of 28.55 for the unpolished surface. This was similar to Fuji II LC® which had a total colour change of 28.16 for the unpolished surface. For Vitremer™, the total colour change increased to 18.07 for the unpolished surface. For the unpolished surfaces, ChemFil™ Rock showed the least colour difference from baseline to 7 days (ΔE*ab = 10.45), followed by Vitremer™ (ΔE*ab = 18.07). Both Fuji II LC® and Riva™ Light Cure showed similar colour change from baseline to 7 days for unpolished surfaces (ΔE*ab of 28.16 and 28.55 respectively). Ketac™ N100 showed the highest staining after 7 days in the staining broth with a colour difference of 43.84. For the polished surfaces, the colour change for Fuji II LC® was 25.72 which was similar to Riva™ Light Cure which was 22.44 and Ketac™ N100 which showed a colour change of 22.79 on the polished surface. ChemFil™ Rock showed the least colour change of 17.69 for the polished surface followed by Vitremer™ which showed a colour change of 23.63 for the polished surface. Thus, for both the unpolished and polished surfaces there was a similar staining pattern. Conclusion: In this study it was demonstrated that all products evaluated in this study showed some degree of staining when exposed to a staining broth when evaluated using the ΔE*ab CIELAB colour evaluation. Ketac™ N100 showed the highest colour change compared to the other materials, but the reason for this was not explored. Both Vitremer™ and ChemFil™ Rock showed similar patterns of staining. / 2020-09-01
|
2 |
Evaluation of Shear Bond Strength of Two Resin-Modified Glass-Ionomer CementsRo, Emily Y 01 January 2003 (has links)
Purpose: To compare the in-vitro shear bond strengths of a new paste-paste formulation of resin-modified glass-ionomer cement (Rm-GIC) to an exising powder-liquid formulation. The study will test the hypothesis that the new paste-paste formulation of Rm-GIC (Fuji-Cem ™, GC Corp, Tokyo, Japan) has the same bond strength as an existing popular powder-liquid formulation of Rm-GIC (Rely-X ™ Luting Cement, 3M, St. Paul, MN)Materials and Methods: A total of 33 human molars were sectioned parallel to the occlusal surface to expose mid-coronal dentin and mounted parallel to the bond shearing device on the universal testing machine (Instron). For Group I samples (Rely-X, n=15), the powder and liquid were measured and adjusted to achieve a ratio of 1.6 and mixed for 30 seconds as recommended by the manufacturer. For Group II (Fuji-Cem, n=18), the paste-paste was expressed from the paste-dispenser provided by the manufacturer and mixed for 10 seconds as recommended. After testing, the teeth from group II were bonded on a different site with the same material but mixed for 20 seconds (n=18). To ensure a uniform flow and bond surface area, the mixed cement was syringed into a cylindrical mould (diameter 2.38mm, height 2mm) and allowed to set under constant force. All samples were subjected to fracture by shear loading on a universal testing machine (Instron) at a uniform crosshead speed of .02" per minute and expressed as MPa. Values were analyzed at the pResults: Wilcoxon rank sums test showed significantly higher shear bond strength values for Rely-X compared to Fuji-Cem mixed both at 10 seconds and 20 seconds. Mixing for 20 seconds resulted in stronger bonds for Fuji-Cem compared to 10 seconds, but was still significantly lower than Rely-X.Conclusions: Within the limitations of the study, the Rely-X powder-liquid formula shows a significantly stronger dentin shear bond strength when compared to the new paste-paste formula of resin-modified glass ionomer cement, Fuji-Cem.
|
3 |
Avaliação da microdureza Knoop e do grau de conversão de dois cimentos de ionômero de vidro modificados por resina em função do tipo de polimerização e do tempo / Evaluation of the Knoop microhardness and the degree of conversion of two resin-modified glass ionomer in function of the type of polymerization and the timeMartins, Leandro de Moura 21 May 2007 (has links)
Os ionômeros de vidro vêm sendo utilizados largamente na odontologia com diversas funções. Suas formulações sofreram alterações durante os anos, como a incorporação de componentes resinosos, para a melhoria de suas propriedades físicas e aumento do tempo de trabalho. Com isso, o estudo teve como objetivo avaliar o grau de conversão e a microdureza Knoop dos cimentos de ionômero de vidro modificados por resina (Rely X Luting e Vitremer, ambos da 3M ESPE) de acordo a forma de polimerização (química ou fotopolimerável por lâmpada halógena Ultralux EL ? Gnatus e LED LEC 1000 ? MMOptics) e o tempo de armazenagem. Três espécimes de cada material, autopolimerizável e fotopolimerizável, e tipo de fotopolimerização (por luz halógena e LED) foram confeccionados para cada tempo experimental de 6 horas, 1, 2, 3, 5, 7 ,11 e 14 dias (n=72). Os espécimes foram armazenados em ambiente escuro a 37°C durante esses períodos. Os 72 espécimes foram analisados pela espectroscopia FT-IR para a medição do grau de conversão (GC). Três espécimes de cada material e tipo de polimerização (n=9) foram confeccionados para a medição da microdureza, com um penetrador diamantado piramidal, tipo Knoop, carga estática de 50 gramas por 30 segundos. Os resultados encontrados demonstraram que o material fotopolimerizado com LED apresentou os maiores valores do grau de conversão e da microdureza. O grau de conversão aumentou com o tempo de armazenagem enquanto a microdureza obteve os maiores resultados entre 24-48 horas. Os resultados permitiram concluir que para os cimentos de ionômero de vidro modificados por resina, Vitremer e Rely X Luting, o material fotopolimerizável onde se utilizou o LED apresentou os melhores resultados e que a microdureza Knoop foi ineficaz para predizer o grau de conversão. / Glass ionomer cement have been widely used for many functions. Over the years, some alterations have been made to improve some physico-mechanical properties and to prolong working time. The purpose of this study was to evaluate the relation of the degree of conversion (DC) and Knoop microhardness of resin modified glass ionomer cements (Rely X Luting and Vitremer - 3M ESPE) with polymerization type (chemical curing and light curing reactions, using halogen light or LED) and time of storage. Three specimens of each material, self-cured and light-cured, and light-curing type (halogen light or LED) were prepared for each period of time (n=72). Specimens were stored in dark and dry conditions, at 37oC, during 6 hours, 1, 2, 3, 5, 7, 11 and 14 days. All the specimens were analyzed by FT-IR spectroscopy to measure the DC. Three specimens of each material and polimeryzation type (n=9) were prepared for the microhardness determination, equipped with a Knoop indenter, 50g load for 30 seconds. Results showed that higher values of DC and Knoop microhardness were found on the LED light-cured material. DC values increased with storage time while the Knoop microhardness achieved its higher values between 24-48 hours. Results showed that the LED light-curing unit used to polymerize the resin modified glass ionomer cement Vitremer achieved better values of DC, between light and self-cured materials, and that the Knoop microhardness could not predict the DC.
|
4 |
Ionômero de vidro resinoso nanoparticulado: avaliação de propriedades físico-químicas e biológicas / Resin modified nano ionomer: physical-chemical and biological evaluationGarcia Júnior, Edélcio 15 October 2009 (has links)
O objetivo deste estudo foi avaliar o cimento de ionômero de vidro modificado por resina de nanopartículas Ketac™N100, por meio de três metodologias diferentes: resposta tecidual em subcutâneo de camundongos isogênicos, liberação de flúor e tensão de contração de polimerização, in vitro. Foram utilizados 90 camundongos isogênicos da linhagem BALB/c, divididos em 9 grupos (n=10), nos quais foram implantados tubos de polietileno contendo o Ketac™ 100, ChemFilR (ionômero de vidro convencional) ou tubo vazio. Nos períodos experimentais de 7, 21 e 63 dias o tubo e o tecido adjacente foram removidos para análise microscópica. Para o ensaio de avaliação da tensão de contração de polimerização, foram utilizados dois bastões de vidro fixados a uma máquina de ensaio universal. Nos bastões foi acoplado um extensômetro para medição da força de contração de polimerização de cinco materiais (Resina Filtek™Z350, CompoglassR F, VitremerMR, Ketac™N100 e ChemFilR), com 10 corpos de prova para cada material. Para o ensaio de liberação de flúor, foram confeccionados 8 corpos de prova de 3 diferentes materiais (Ketac™ 100, Vidrion R e Resina Filtek™ Z250), colocados individualmente em 1 ml de saliva artificial. O corpo de prova foi trocado a cada dia por 15 dias e a solução obtida utilizada para a leitura do íon fluoreto.Os resultados microscópicos evidenciaram que a inflamação presente na abertura dos tubos, aos 7 dias, sofreu uma diminuição em área e espessura até os 63 dias, nos 2 materiais e no grupo controle. Comparando a área da reação inflamatória o Ketac™N100 foi diferente estatisticamente do ChemFilR, nos períodos de 7 e 21 dias (p>0,05), com uma área menor para o Ketac™N100. A espessura da reação inflamatória nos períodos de 7 e 21 dias apresentou valores semelhantes entre o Ketac™N100 e ChemFilR (p>0,05). Aos 63 dias, os valores foram estatisticamente diferentes, com um pequeno aumento de espessura para o Ketac™N100. Os valores de tensão de contração de polimerização obtidos seguiram a seguinte ordem crescente: ChemFilR < VitremerMR < Ketac™N100 < CompoglassR F ~ Filtek™Z350 (p>0,05). Quando comparados dois a dois, o ionômero modificado por resina de nanopartículas Ketac™N100 se aproximou mais dos valores da resina Filtek™ Z350 (p>0,05) do que do ionômero de vidro convencional ChemFilR (p<0,05). A sua liberação de flúor ocorreu mais significativamente nos dois primeiros dias, com valores médios 33% menores em comparação ao Vidrion R. Concluímos que o ionômero resinoso nanoparticulado Ketac™N100 é um material que induz uma resposta inflamatória tecidual satisfatória em subcutâneo de camundongos isogênicos. Sua contração de polimerização foi menor do que de a resina Filtek™ Z350 e a liberação de flúor foi um terço menor do que a dos ionômeros convencionais. / The aim of this study was to evaluate the resin modified nano ionomer Ketac™N100, by three different methodologies: tissue response in of isogenic mice subcutaneous, fluoride release and shrinkage stress of polymerization in vitro. We used 90 isogenic mice (BALB / c), divided into 9 groups (n = 10), which were implanted with polyethylene tubes containing Ketac™ 100, ChemFilR (Ionomer conventional) or empty tube. In the experimental periods of 7, 21 and 63 days the tube and the surrounding tissue were removed for microscopic analysis. To evaluating the stress of contraction of polymerization, we used two glass rods attached to a universal testing machine. In the rods was attached to an extensometer to obtain the measure of the polymerization shrinkage strength of five materials (resin Filtek™Z350, CompoglassR F, VitremerMR F, Ketac™ 100 and ChemFilR), with 10 specimens for each material. In the fluoride release test, 8 specimens of 3 different materials (Ketac™ 100, Vidrion R and Resin Filtek™ Z250) placed individually in 1 ml of artificial saliva. The specimens were changed each day for 15 days and we use this solution used for reading the fluoride ion. The microscopic results showed that the inflammation in the opening of the tubes at 7 days decreased in area and thickness up to 63 days in 2 materials and the control group. Comparing the inflammatory reaction area, Ketac™N100 was statistically different from ChemFilR, in periods of 7 and 21 days (p> 0.05), with a smaller area for Ketac™N100. The inflammatory reaction in the periods of 7 and 21 days showed similar values between the Ketac™N100 and ChemFilR (p> 0.05). At 63 days, the values were statistically different, with a small increase in thickness to Ketac™N100. The values of polymerization shrinkage strength obtained after polymerization followed this ascending order: ChemFilR < VitremerMR F < Ketac™ 100 < CompoglassR F ~ Filtek™Z350 (p> 0.05). When compared two by two, the resin modified nano ionomer Ketac™N100 approached most of the values of resin Filtek™ Z350(p> 0.05) than the conventional glass Ionomer ChemFilR (p <0.05). The fluoride release occurred more significantly in the first two days, with average 33% lower compared with Vidrion R. We conclude that the resin modified nano ionomer Ketac™N100 is a material that induces an satisfactory inflammatory response in subcutaneous tissue of isogenic mice. Its polymerization shrinkage strength was lower than the resin Filtek™ Z350 and fluoride release was a third lower than the conventional glass ionomer.
|
5 |
Selamento de fossas e fissuras após 6 meses com diferentes materiais: Resinoso X Ionómerico / Pit and fissure sealants with different materials: Resin Based X Glass Ionomer Cement Results after six monthsGonçalves, Priscilla Santana Pinto 24 May 2013 (has links)
Este estudo avaliou e comparou, após 6 meses, dois materiais usados como selantes de fossas e fissuras, FluroShield® (Dentsply, Germany) e Clinpro™ XT Varnish (3M ESPE, Dental Products, St. Paul, MN, U.S.A.) quanto à retenção e características superficiais. Além disso, comparou-os, com um grupo controle não selado, com relação à incidência de cárie no período. Participaram deste trabalho, 31 crianças de 6 a 8 anos de idade, com no mínimo dois primeiros molares permanentes hígidos e história de cárie, num total de 114 dentes divididos aleatoriamente em três grupos: CLP (Clinpro™ XT Varnish), FS (FluroShield®) e ctr (Controle). O selamento foi realizado sob isolamento relativo para ambos os materiais testados, após profilaxia prévia com jato de bicarbonato de sódio e água e, condicionamento com gel de ácido fosfórico a 35% por 15 segundos. A avaliação clínica foi realizada por dois examinadores calibrados após 6 meses. Avaliou-se a retenção e a incidência de cárie nas cinco áreas oclusais: OM, OC, OD, OV e OL; e as características superficiais e a retenção considerando a superfície oclusal como um todo. Houve diferença estatisticamente significante para a prevalência de cárie (teste de Kruskal Wallis, p=0,000 a 0,007), para todas as áreas, entre os grupos selados (CLP e FS) e o controle. Sendo que quanto à incidência, só foi verificada diferença significante para a área OL (p=0,014). O teste do Qui-quadrado identificou que não houve diferença estatisticamente significante entre os materiais, com relação à taxa de sucesso de retenção da superfície oclusal como um todo, quando se considerou o somatório das cinco áreas (p=0,079) ou quando se verificou a retenção por superfície (p=0,141). No entanto, a análise do conjunto de critérios de retenção na superfície oclusal toda, mostrou uma diferença estatisticamente significante para o FS (teste de Mann-Whitney, p=0,002). Em relação às características superficiais, o FS apresentou superioridade durante o período estudado de forma significativa, indicada pelo teste de Mann-Whitney, para a deterioração marginal (p=0,000), descoloração marginal (p=0,008), e descoloração superficial (p=0,001). Ele também foi superior, mas não significante, quanto à textura superficial. A frequência de bolhas nas superfícies seladas não mostrou diferença significativa (teste do Qui-quadrado, p=0,758) entre os materiais. Desta forma, pode-se concluir que ambos os materiais foram efetivos nos primeiros 6 meses de avaliação, embora, tenha havido melhor desempenho clínico do selante FluroShield®. / This study evaluated and compared two dental sealants, for 6 months. The materials, Fluroshield® (Dentsply, Germany) and Clinpro™ XT Varnish (3M ESPE Dental Products, St. Paul, MN, USA) were analyzed with regard their retention and superficial characteristics. They also were compared with a control group, without sealant, regarding the dental caries incidence. The sample was composed by 31 children from 6 to 8 years of age, with at least two sound first permanent molars, but with a dental caries history. A total of 114 teeth were randomly alocated in three groups: CLP (Clinpro™ XT Varnish), FS (Fluroshield®) and ctr (Control). The sealings were applyed under relative isolation after a previous prophylaxis with a water-air-polishing jet, and an enamel etching with a 35% phosphoric acid gel for 15 seconds. Clinical evaluation was performed by two calibrated examiners after 6 months considering: the sealant retention and the incidence of occlusal caries in five areas: OM, OC, OD, OV and OL and finally, the surface characteristics and retention considering the occlusal surface as only one area. It was shown a significant difference (Kruskal-Wallis test, p=0.000 to 0.007) for the caries prevalence in all areas comparing the sealed group (CLP and FS) versus control. Whereas the incidence, it was only verified a significant diference for the OL area (p=0.014). There was no significant difference (Chi-square test, p=0.079) between the materials regarding the success rate of retention for the occlusal surface when it was considered the sum of the five areas, or for the occlusal surface without divisions (p=0.141). Nevertheless there was a significant difference between the sealants (Mann-Whitney test, p=0.002), with better results for the FS group, when it was analysed the influence of all the retention criteria. Regarding the surface characteristics, the FS group showed a significant superiority (Mann-Whitney test) during the period of the study for the impairment marginal (p=0.000), marginal discoloration (p=0.008), and surface discoloration (p=0.001). Although FS had also been superior for the surface texture, this result was not significant. The frequency of bubbles in the sealed surfaces was not significant (Qui-square test, p=0.758) between the materials. Thus, it can be concluded that both materials were effective during this first 6 months of evaluation, although it is evident that the Fluroshield® sealant had shown a better clinical performance.
|
6 |
Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentinMenegatti, Giovanna Emann Tavares 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
|
7 |
Avaliação da interface dentina/agentes protetores em restaurações com resina composta, através de microscopia eletrônica de varreduraPeliz Fernandes, Maria Inez Lemos [UNESP] 17 October 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-10-17Bitstream added on 2014-06-13T20:41:43Z : No. of bitstreams: 1
pelizfernandes_mil_dr_arafo.pdf: 974117 bytes, checksum: ac5bfc8ea4cf08f87cfa61b609255346 (MD5) / O objetivo deste estudo foi avaliar a formação de microfendas entre diferentes agentes de proteção do complexo dentina-polpa e a estrutura dental. Cavidades de classe V, com dimensões padronizadas, foram preparadas nas faces V e L de 60 terceiros molares humanos recém-extraídos, divididos em 6 grupos: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; e restauradas com resina composta microhíbrida Filtek Z250 (3M ESPE), segundo as normas estabelecidas pelos fabricantes, exceto para os grupos 5 e 6 onde a dentina foi hibridizada previamente à aplicação do ionômero de vidro modificado por resina. Após ciclagem térmica, um segmento longitudinal de 800 æm de espessura foi obtido da porção central de cada restauração e, em seguida, submetidos às etapas de fixação, desidratação em grau ascendente de etanol e secagem através de HMDS. A adaptação interna dos materiais à parede axial foi analisada através do MEV, com 1000x de magnificação. Os dados obtidos foram analisados através do procedimento estatístico não-paramétrico de Kruskal-Wallis (p<0.05). O cimento de hidróxido de cálcio e ionômero de vidro modificado por resina aplicados sozinhos ou em conjunto (p<0.001), sob restauração de resina composta, resultou em microfendas com amplitude estatisticamente maiores do que quando a dentina foi somente hibridizada previamente a restauração. A hibridização dentinária permitiu selamento superior da interface dentina/restauração do que os demais agentes protetores avaliados. / The objective of this study was to evaluate the microgap with different materials used for pulp protection. The null hypothesis tested in this in vitro study was that the combination among calcium hydroxide, resin-modified glass ionomer and dentin adhesive, used as pulp protection in composite restorations would not result in greater axial gap than that obtained by hybridization only. Standardized class V preparations were performed in buccal and lingual surfaces of sixty caries-free extracted human third molars. The prepared teeth were randomly assessed in 6 groups: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; and restored with a microhybrid composite resin Filtek Z250 (3M ESPE), following the manufacturer's instructions. Except for group 5 and 6, which the ethanol- and water-based adhesive were applied prior the resin-modified glass ionomer. The specimens were then cross-sectioned with a thickness of 800 æm, fixed, dehydrated in ascending ethanol, and dried by means HMDS. The specimens were mounted in stubs, sputter coated and the internal adaptation of the materials to the axial wall analyzed under SEM with 1,000x magnification. The data obtained were analyzed with nonparametric tests (Kruskal-Wallis, p<0.05). The null hypothesis was rejected. Calcium hydroxide and resin-modified glass ionomer applied alone or in conjunction (p<0.001), under composite resin restoration, resulted in statistically wider micro gaps than when the dentin was only hybridized prior the restoration. Dentin hybridization provides superior sealing of the dentin and restoration interface than other pulp protection materials.
|
8 |
Avaliação da interface dentina/agentes protetores em restaurações com resina composta, através de microscopia eletrônica de varredura /Peliz Fernandes, Maria Inez Lemos. January 2003 (has links)
Orientador: Sillas Luiz Lordelo Duarte Júnior / Banca: Welingtom Dinelli / Banca: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Manio de Carvalho Tibúrcio / Banca: Camilo Anauate Netto / Resumo: O objetivo deste estudo foi avaliar a formação de microfendas entre diferentes agentes de proteção do complexo dentina-polpa e a estrutura dental. Cavidades de classe V, com dimensões padronizadas, foram preparadas nas faces V e L de 60 terceiros molares humanos recém-extraídos, divididos em 6 grupos: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; e restauradas com resina composta microhíbrida Filtek Z250 (3M ESPE), segundo as normas estabelecidas pelos fabricantes, exceto para os grupos 5 e 6 onde a dentina foi hibridizada previamente à aplicação do ionômero de vidro modificado por resina. Após ciclagem térmica, um segmento longitudinal de 800 æm de espessura foi obtido da porção central de cada restauração e, em seguida, submetidos às etapas de fixação, desidratação em grau ascendente de etanol e secagem através de HMDS. A adaptação interna dos materiais à parede axial foi analisada através do MEV, com 1000x de magnificação. Os dados obtidos foram analisados através do procedimento estatístico não-paramétrico de Kruskal-Wallis (p<0.05). O cimento de hidróxido de cálcio e ionômero de vidro modificado por resina aplicados sozinhos ou em conjunto (p<0.001), sob restauração de resina composta, resultou em microfendas com amplitude estatisticamente maiores do que quando a dentina foi somente hibridizada previamente a restauração. A hibridização dentinária permitiu selamento superior da interface dentina/restauração do que os demais agentes protetores avaliados. / Abstract: The objective of this study was to evaluate the microgap with different materials used for pulp protection. The null hypothesis tested in this in vitro study was that the combination among calcium hydroxide, resin-modified glass ionomer and dentin adhesive, used as pulp protection in composite restorations would not result in greater axial gap than that obtained by hybridization only. Standardized class V preparations were performed in buccal and lingual surfaces of sixty caries-free extracted human third molars. The prepared teeth were randomly assessed in 6 groups: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; and restored with a microhybrid composite resin Filtek Z250 (3M ESPE), following the manufacturer's instructions. Except for group 5 and 6, which the ethanol- and water-based adhesive were applied prior the resin-modified glass ionomer. The specimens were then cross-sectioned with a thickness of 800 æm, fixed, dehydrated in ascending ethanol, and dried by means HMDS. The specimens were mounted in stubs, sputter coated and the internal adaptation of the materials to the axial wall analyzed under SEM with 1,000x magnification. The data obtained were analyzed with nonparametric tests (Kruskal-Wallis, p<0.05). The null hypothesis was rejected. Calcium hydroxide and resin-modified glass ionomer applied alone or in conjunction (p<0.001), under composite resin restoration, resulted in statistically wider micro gaps than when the dentin was only hybridized prior the restoration. Dentin hybridization provides superior sealing of the dentin and restoration interface than other pulp protection materials. / Doutor
|
9 |
Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentinGiovanna Emann Tavares Menegatti 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
|
10 |
Avaliação da microdureza Knoop e do grau de conversão de dois cimentos de ionômero de vidro modificados por resina em função do tipo de polimerização e do tempo / Evaluation of the Knoop microhardness and the degree of conversion of two resin-modified glass ionomer in function of the type of polymerization and the timeLeandro de Moura Martins 21 May 2007 (has links)
Os ionômeros de vidro vêm sendo utilizados largamente na odontologia com diversas funções. Suas formulações sofreram alterações durante os anos, como a incorporação de componentes resinosos, para a melhoria de suas propriedades físicas e aumento do tempo de trabalho. Com isso, o estudo teve como objetivo avaliar o grau de conversão e a microdureza Knoop dos cimentos de ionômero de vidro modificados por resina (Rely X Luting e Vitremer, ambos da 3M ESPE) de acordo a forma de polimerização (química ou fotopolimerável por lâmpada halógena Ultralux EL ? Gnatus e LED LEC 1000 ? MMOptics) e o tempo de armazenagem. Três espécimes de cada material, autopolimerizável e fotopolimerizável, e tipo de fotopolimerização (por luz halógena e LED) foram confeccionados para cada tempo experimental de 6 horas, 1, 2, 3, 5, 7 ,11 e 14 dias (n=72). Os espécimes foram armazenados em ambiente escuro a 37°C durante esses períodos. Os 72 espécimes foram analisados pela espectroscopia FT-IR para a medição do grau de conversão (GC). Três espécimes de cada material e tipo de polimerização (n=9) foram confeccionados para a medição da microdureza, com um penetrador diamantado piramidal, tipo Knoop, carga estática de 50 gramas por 30 segundos. Os resultados encontrados demonstraram que o material fotopolimerizado com LED apresentou os maiores valores do grau de conversão e da microdureza. O grau de conversão aumentou com o tempo de armazenagem enquanto a microdureza obteve os maiores resultados entre 24-48 horas. Os resultados permitiram concluir que para os cimentos de ionômero de vidro modificados por resina, Vitremer e Rely X Luting, o material fotopolimerizável onde se utilizou o LED apresentou os melhores resultados e que a microdureza Knoop foi ineficaz para predizer o grau de conversão. / Glass ionomer cement have been widely used for many functions. Over the years, some alterations have been made to improve some physico-mechanical properties and to prolong working time. The purpose of this study was to evaluate the relation of the degree of conversion (DC) and Knoop microhardness of resin modified glass ionomer cements (Rely X Luting and Vitremer - 3M ESPE) with polymerization type (chemical curing and light curing reactions, using halogen light or LED) and time of storage. Three specimens of each material, self-cured and light-cured, and light-curing type (halogen light or LED) were prepared for each period of time (n=72). Specimens were stored in dark and dry conditions, at 37oC, during 6 hours, 1, 2, 3, 5, 7, 11 and 14 days. All the specimens were analyzed by FT-IR spectroscopy to measure the DC. Three specimens of each material and polimeryzation type (n=9) were prepared for the microhardness determination, equipped with a Knoop indenter, 50g load for 30 seconds. Results showed that higher values of DC and Knoop microhardness were found on the LED light-cured material. DC values increased with storage time while the Knoop microhardness achieved its higher values between 24-48 hours. Results showed that the LED light-curing unit used to polymerize the resin modified glass ionomer cement Vitremer achieved better values of DC, between light and self-cured materials, and that the Knoop microhardness could not predict the DC.
|
Page generated in 0.1172 seconds