• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida / Effect of light sources with different wavelengths in micro and ultramicrohardness and elastic modulus of a nanohybrid composite resin. An in vitro study

Araujo, Jesuina Lamartine Nogueira 04 June 2013 (has links)
Este trabalho avaliou in vitro a dureza e módulo de elasticidade de uma resina composta nanohíbrida (Tetric N-Ceram/Ivoclair-Vivadent) com diferentes cores, fotoativada por duas unidades com diferentes comprimentos de onda em 3 espessuras (1, 2 e 3mm) comparadas à partir da superfície irradiada (0mm). Os espécimes foram divididos em grupos (n=5): microdureza Knoop-KHN, ultramicrodureza-DUH e módulo de elasticidade-ME, cor (A2 e Bleach-M(BM), fotoativador LEDazul (Elipar Freeligth2/3M(750mW/25s/430-480nm(FL) e LEDazul/violeta Bluephase/Ivoclar/Vivadent (1200mW/cm²/15s/380-515nm(B15) e 30s(B30). Os espécimes foram armazenados por 24h/37ºC. Os ensaios de KHN foram realizados no HMV-2000/Shimadzu, com carga de 25gf/40s, e de DUH e ME no DUH 211S/Shimadzu com força de 10mN e tempo de espera de 0s. Foram realizadas 5 endentações na superfície irradiada (0mm) e na base das amostras (1, 2 e 3mm). A análise estatística foi realizada por ANOVA, Tukey e correlação de Pearson (p<0,01%). O teste de Pearson mostrou haver correlação direta entre a KHN e a DUH. A fonte FL promoveu maiores valores de KHN e de DUH para as duas resinas testadas; enquanto que a fonte B15, promoveu o maior valor de ME. Quanto às espessuras, 0 e 1mm apresentaram maiores valores de KHN e de DUH, e menores de ME que as espessuras de 2 e 3mm. A cor A2 apresentou maior valor de KHN e DUH e menor ME que a cor Bleach-M. Assim, de acordo com a metodologia proposta e os resultados apresentados pode-se concluir que apesar de a luz LEDazul/violeta propor uma maior eficácia na polimerização de resinas de cor clara, no tocante às propriedades avaliadas isso não foi verificado. / This study evaluated in vitro the hardness (micro and ultramicro) and elastic modulus of a nanohybrid composite resin (Tetric N-Ceram/Ivoclar-Vivadent) with different colors, light sources and thickness. The specimens were divided into groups (n=5): KHN-Knoop microhardness, DUH-nanohardness and ME-elastic modulus; colors: A2 and Bleach-M (BM); light sources: LEDblue Elipar Free light 2/3M-ESPE (750mW/cm²/ 25s/430-480nm- (FL)), LEDblue/violet Bluephase/Ivoclar-Vivadent (1.200mw/cm²/15s/380-515nm) (B15) and 30s (B30); thickness: 1mm, 2mm and 3mm, compared to the irradiated surface (0mm). Specimens were stored dry for 24hours at 37ºC after photo curing. Assays were performed at KHN in HMV-2000/ Shimadzu with load of 25gf at 40s and DUH/ME in DUH 211S/Shimadzu with force of 10mN and no hold time (0s). 5 indentations of each test were made in the surfaces opposites to the photo curing. A statistical analysis was performed by ANOVA, Tukey and Pearson correlation (p<0.01%). Pearsons Test showed a direct correlation between KHN and DUH. Comparison between KHN and ME in the studied resins indicated that the light source FL promoted higher values of KHN and DUH to both resins tested, whereas the B15 light source promoted the higher ME value. Regarding thickness 0mm and 1mm showed higher KHN and DUH and lower ME than 2 and 3mm thickness. A2 color showed higher KHN and DUH and lower ME than BM. Thus, according to the proposed methods and the presented results, the LEDblue/violet was not better for curing the light color of the nanohybrid resin, than LEDblue.
2

Influência das dimensões e do modo de fotoativação do corpo de prova sobre os testes de sorção, de solubilidade e de microdureza Knoop / Influence of the specimen dimensions and mode of photoactivation on the tests of sorption, solubility and Knoop microhardness

Silva, Luciana Maria da 11 February 2011 (has links)
O presente estudo avaliou a influência das dimensões e das formas de fotoativação do corpo de prova através dos testes de sorção, de solubilidade e de microdureza Knoop. Este trabalho foi dividido em duas fases. Na primeira fase, corpos de prova de um compósito experimental medindo 15 mm de diâmetro x 1 mm de espessura foram confeccionados usando uma matriz de teflon bipartida, sendo o compósito inserido em um único incremento e, em seguida, planificado por uma tira de poliéster aderida a uma placa de vidro. Todos os grupos tiveram as mesmas dimensões, porém, foram fotopolimerizados de três maneiras diferentes: G1- Com cinco exposições de cada lado do corpo de prova, de acordo com o padrão especificado pela ISO 4049; G2- Retirando a ponta do aparelho fotoativador de forma que a luz atingisse toda a superfície do espécime e G3- Distanciando a ponta do fotopolimerizador 1,5 cm com o mesmo intuito (n=5). Anova (p<0,05) e teste de Tukey 5% para diferenciação das médias não mostraram diferenças estatísticas significativas entre os grupos para o teste de sorção (p=0,517). Os valores em g/mm3 com seus desvios padrão foram: G1=22,58±1,20; G2=23,51±0,61 e G3=22,16±1,39. Já para o teste de solubilidade foram encontradas diferenças estatísticas significativas (p=0,002), de acordo com as letras sobrescritas. Os valores em g/mm3 com seus respectivos desvios padrão foram G1=0,54±0,14B; G2=0,37±0,14B e G3=1,04±0,09A. Para o teste de microdureza Knoop, a análise estatística apresentou diferenças significativas entre os grupos (p=0,003). Os valores em KHN com seus desvios padrão foram G1=78,9±2,74A; G2=69,4±4,77B e G3=67,4±4,94B. A conclusão desta primeira fase foi que a melhor forma de fotoativação foi do G1 (de acordo com a ISO), a qual apresentou menor solubilidade e a maior microdureza Knoop. A segunda fase do trabalho foi feita utilizando apenas a melhor forma de fotoativação obtida na primeira fase que foi correspondente ao G1 (ISO 4049), variando as dimensões dos corpos de prova com os tamanhos mais usados na literatura de sorção e solubilidade. Os grupos experimentais foram divididos em: (diametro x espessura) g1=15x1 mm (ISO), g2=5,8 x 0,8mm e g3=6 x 0,5 mm, confeccionados da mesma forma que os corpos de prova da primeira etapa. Os espécimes foram então submetidos ao teste de sorção, de solubilidade e de microdureza Knoop. ANOVA (p<0,05) e teste de Tukey (5%) mostraram que não houve diferenças estatisticamente significativas para o teste de sorção (p=0,915). Os valores em g/mm3 com seus respectivos desvios padrão foram: g1=22,58±1,2; g2=22,28±2,26 e g3=22,78±2,02. Já para o teste de solubilidade foram encontradas diferenças estatísticas significativas (p=0,006). Os valores em g/mm3 com seus respectivos desvios padrão foram: g1=0,54±0,14B; g2=3,2±2,07A, e g3=2,16±1,06AB. O teste de microdureza Knoop não demonstrou diferenças estatisticamente significativas entre os grupos (p= 0,106). Os valores em KHN, com seus respectivos desvios padrão foram: g1=62,12±0,86; g2=64,88±4,21 e g3=66,20±2,33. Levando em consideração os diversos fatores estudados pode-se concluir que as dimensões e a forma de fotoativação preconizadas pela ISO 4049 parecem ser a melhor forma de confeccionar os corpos de prova para os testes de sorção e de solubilidade, associados ao teste de microdureza Knoop. / This study evaluated the influence of the dimensions and the light-cure mode of specimens in the tests of sorption, solubility and Knoop microhardness. This research was divided into two phases. In the first stage, disc shaped samples of an experimental composite resin (15 mm in diameter x 1 mm in thickness) were fabricated using a teflon split mold., The composite was inserted in one increment and then flattened by a polyester strip adhered to a glass plate. All groups had the same dimensions, however, were polymerized in three different ways: G1-five exposures for each side of the specimen, according to the standard specified by ISO 4049, G2-removing the tip of the curing unit and allowing light to reach all the surface of the specimen, and G3-distancing the tip of the curing unit 1.5 cm with the same intention (n=5). Anova and Tukey test (p<0.05) for the means comparisons showed no statistically significant differences among groups for the sorption test (p=0.517). The values in g/mm3 with their standard deviation were: G1 = 22.58±1.20, G2 = 23.51±0.61 and G3=22.16±1.39. The solubility test showed statistically significant differences (p=0.002), according to the superscript letters. The values in g/mm3 with their respective standard deviations were G1=0.54±0.14B, G2=0.37±0.14B and G3=1.04±0.09A. For the microhardness test, statistical analysis showed significant differences among groups (p=0.003). The KHN values with their standard deviation were: G1 = 78.9±2.74A, G2 = 69.4±4.77B and G3 = 67.4±4.94B. The conclusion of this first phase was that the best way of light-curing was G1 (according to ISO), which showed lower solubility and the higher Knoop microhardness. The second research stage was performed using only the best way of light-curing achieved in the first round, which was corresponding to Group 1 (ISO 4049), varying the dimensions of the specimens with the sizes most used in the literature of sorption and solubility. The experimental groups were divided into: (Diameter x thickness) g1=15x1 mm (ISO), g2=5.8x0.8 mm and g3=6x0.5 mm, prepared in the same way as the samples of the first phase. The specimens were then submitted to the sorption, solubility and Knoop microhardness tests. ANOVA and Tukey test (p<0.05) showed no statistically significant differences for the sorption test (p=0.915).The values in g/mm3 with their respective standard deviations were: g1=22.58±1.2; g2=22.28±2.26 and g3=22.78±2.02. The solubility test showed statistically differences among groups (p=0.006). The values in g/mm3 with their respective standard deviations were: g1 = 0.54±0.14B, g2=3.2±2.07A, and g3=2.16±1.06AB. The Knoop microhardness test showed no statistically significant differences among groups (p=0.106). The values in KHN with their respective standard deviations were: g1=62.12±0.86, g2=64.88±4.21 and g3=66.20±2.33. Taking into consideration the studied factors, it can be concluded that the size and the shape of photoactivation recommended by ISO 4049 seems to be the best way of preparing the specimens for sorption and solubility tests, associated with the Knoop microhardness test.
3

Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida / Effect of light sources with different wavelengths in micro and ultramicrohardness and elastic modulus of a nanohybrid composite resin. An in vitro study

Jesuina Lamartine Nogueira Araujo 04 June 2013 (has links)
Este trabalho avaliou in vitro a dureza e módulo de elasticidade de uma resina composta nanohíbrida (Tetric N-Ceram/Ivoclair-Vivadent) com diferentes cores, fotoativada por duas unidades com diferentes comprimentos de onda em 3 espessuras (1, 2 e 3mm) comparadas à partir da superfície irradiada (0mm). Os espécimes foram divididos em grupos (n=5): microdureza Knoop-KHN, ultramicrodureza-DUH e módulo de elasticidade-ME, cor (A2 e Bleach-M(BM), fotoativador LEDazul (Elipar Freeligth2/3M(750mW/25s/430-480nm(FL) e LEDazul/violeta Bluephase/Ivoclar/Vivadent (1200mW/cm²/15s/380-515nm(B15) e 30s(B30). Os espécimes foram armazenados por 24h/37ºC. Os ensaios de KHN foram realizados no HMV-2000/Shimadzu, com carga de 25gf/40s, e de DUH e ME no DUH 211S/Shimadzu com força de 10mN e tempo de espera de 0s. Foram realizadas 5 endentações na superfície irradiada (0mm) e na base das amostras (1, 2 e 3mm). A análise estatística foi realizada por ANOVA, Tukey e correlação de Pearson (p<0,01%). O teste de Pearson mostrou haver correlação direta entre a KHN e a DUH. A fonte FL promoveu maiores valores de KHN e de DUH para as duas resinas testadas; enquanto que a fonte B15, promoveu o maior valor de ME. Quanto às espessuras, 0 e 1mm apresentaram maiores valores de KHN e de DUH, e menores de ME que as espessuras de 2 e 3mm. A cor A2 apresentou maior valor de KHN e DUH e menor ME que a cor Bleach-M. Assim, de acordo com a metodologia proposta e os resultados apresentados pode-se concluir que apesar de a luz LEDazul/violeta propor uma maior eficácia na polimerização de resinas de cor clara, no tocante às propriedades avaliadas isso não foi verificado. / This study evaluated in vitro the hardness (micro and ultramicro) and elastic modulus of a nanohybrid composite resin (Tetric N-Ceram/Ivoclar-Vivadent) with different colors, light sources and thickness. The specimens were divided into groups (n=5): KHN-Knoop microhardness, DUH-nanohardness and ME-elastic modulus; colors: A2 and Bleach-M (BM); light sources: LEDblue Elipar Free light 2/3M-ESPE (750mW/cm²/ 25s/430-480nm- (FL)), LEDblue/violet Bluephase/Ivoclar-Vivadent (1.200mw/cm²/15s/380-515nm) (B15) and 30s (B30); thickness: 1mm, 2mm and 3mm, compared to the irradiated surface (0mm). Specimens were stored dry for 24hours at 37ºC after photo curing. Assays were performed at KHN in HMV-2000/ Shimadzu with load of 25gf at 40s and DUH/ME in DUH 211S/Shimadzu with force of 10mN and no hold time (0s). 5 indentations of each test were made in the surfaces opposites to the photo curing. A statistical analysis was performed by ANOVA, Tukey and Pearson correlation (p<0.01%). Pearsons Test showed a direct correlation between KHN and DUH. Comparison between KHN and ME in the studied resins indicated that the light source FL promoted higher values of KHN and DUH to both resins tested, whereas the B15 light source promoted the higher ME value. Regarding thickness 0mm and 1mm showed higher KHN and DUH and lower ME than 2 and 3mm thickness. A2 color showed higher KHN and DUH and lower ME than BM. Thus, according to the proposed methods and the presented results, the LEDblue/violet was not better for curing the light color of the nanohybrid resin, than LEDblue.
4

Influência das dimensões e do modo de fotoativação do corpo de prova sobre os testes de sorção, de solubilidade e de microdureza Knoop / Influence of the specimen dimensions and mode of photoactivation on the tests of sorption, solubility and Knoop microhardness

Luciana Maria da Silva 11 February 2011 (has links)
O presente estudo avaliou a influência das dimensões e das formas de fotoativação do corpo de prova através dos testes de sorção, de solubilidade e de microdureza Knoop. Este trabalho foi dividido em duas fases. Na primeira fase, corpos de prova de um compósito experimental medindo 15 mm de diâmetro x 1 mm de espessura foram confeccionados usando uma matriz de teflon bipartida, sendo o compósito inserido em um único incremento e, em seguida, planificado por uma tira de poliéster aderida a uma placa de vidro. Todos os grupos tiveram as mesmas dimensões, porém, foram fotopolimerizados de três maneiras diferentes: G1- Com cinco exposições de cada lado do corpo de prova, de acordo com o padrão especificado pela ISO 4049; G2- Retirando a ponta do aparelho fotoativador de forma que a luz atingisse toda a superfície do espécime e G3- Distanciando a ponta do fotopolimerizador 1,5 cm com o mesmo intuito (n=5). Anova (p<0,05) e teste de Tukey 5% para diferenciação das médias não mostraram diferenças estatísticas significativas entre os grupos para o teste de sorção (p=0,517). Os valores em g/mm3 com seus desvios padrão foram: G1=22,58±1,20; G2=23,51±0,61 e G3=22,16±1,39. Já para o teste de solubilidade foram encontradas diferenças estatísticas significativas (p=0,002), de acordo com as letras sobrescritas. Os valores em g/mm3 com seus respectivos desvios padrão foram G1=0,54±0,14B; G2=0,37±0,14B e G3=1,04±0,09A. Para o teste de microdureza Knoop, a análise estatística apresentou diferenças significativas entre os grupos (p=0,003). Os valores em KHN com seus desvios padrão foram G1=78,9±2,74A; G2=69,4±4,77B e G3=67,4±4,94B. A conclusão desta primeira fase foi que a melhor forma de fotoativação foi do G1 (de acordo com a ISO), a qual apresentou menor solubilidade e a maior microdureza Knoop. A segunda fase do trabalho foi feita utilizando apenas a melhor forma de fotoativação obtida na primeira fase que foi correspondente ao G1 (ISO 4049), variando as dimensões dos corpos de prova com os tamanhos mais usados na literatura de sorção e solubilidade. Os grupos experimentais foram divididos em: (diametro x espessura) g1=15x1 mm (ISO), g2=5,8 x 0,8mm e g3=6 x 0,5 mm, confeccionados da mesma forma que os corpos de prova da primeira etapa. Os espécimes foram então submetidos ao teste de sorção, de solubilidade e de microdureza Knoop. ANOVA (p<0,05) e teste de Tukey (5%) mostraram que não houve diferenças estatisticamente significativas para o teste de sorção (p=0,915). Os valores em g/mm3 com seus respectivos desvios padrão foram: g1=22,58±1,2; g2=22,28±2,26 e g3=22,78±2,02. Já para o teste de solubilidade foram encontradas diferenças estatísticas significativas (p=0,006). Os valores em g/mm3 com seus respectivos desvios padrão foram: g1=0,54±0,14B; g2=3,2±2,07A, e g3=2,16±1,06AB. O teste de microdureza Knoop não demonstrou diferenças estatisticamente significativas entre os grupos (p= 0,106). Os valores em KHN, com seus respectivos desvios padrão foram: g1=62,12±0,86; g2=64,88±4,21 e g3=66,20±2,33. Levando em consideração os diversos fatores estudados pode-se concluir que as dimensões e a forma de fotoativação preconizadas pela ISO 4049 parecem ser a melhor forma de confeccionar os corpos de prova para os testes de sorção e de solubilidade, associados ao teste de microdureza Knoop. / This study evaluated the influence of the dimensions and the light-cure mode of specimens in the tests of sorption, solubility and Knoop microhardness. This research was divided into two phases. In the first stage, disc shaped samples of an experimental composite resin (15 mm in diameter x 1 mm in thickness) were fabricated using a teflon split mold., The composite was inserted in one increment and then flattened by a polyester strip adhered to a glass plate. All groups had the same dimensions, however, were polymerized in three different ways: G1-five exposures for each side of the specimen, according to the standard specified by ISO 4049, G2-removing the tip of the curing unit and allowing light to reach all the surface of the specimen, and G3-distancing the tip of the curing unit 1.5 cm with the same intention (n=5). Anova and Tukey test (p<0.05) for the means comparisons showed no statistically significant differences among groups for the sorption test (p=0.517). The values in g/mm3 with their standard deviation were: G1 = 22.58±1.20, G2 = 23.51±0.61 and G3=22.16±1.39. The solubility test showed statistically significant differences (p=0.002), according to the superscript letters. The values in g/mm3 with their respective standard deviations were G1=0.54±0.14B, G2=0.37±0.14B and G3=1.04±0.09A. For the microhardness test, statistical analysis showed significant differences among groups (p=0.003). The KHN values with their standard deviation were: G1 = 78.9±2.74A, G2 = 69.4±4.77B and G3 = 67.4±4.94B. The conclusion of this first phase was that the best way of light-curing was G1 (according to ISO), which showed lower solubility and the higher Knoop microhardness. The second research stage was performed using only the best way of light-curing achieved in the first round, which was corresponding to Group 1 (ISO 4049), varying the dimensions of the specimens with the sizes most used in the literature of sorption and solubility. The experimental groups were divided into: (Diameter x thickness) g1=15x1 mm (ISO), g2=5.8x0.8 mm and g3=6x0.5 mm, prepared in the same way as the samples of the first phase. The specimens were then submitted to the sorption, solubility and Knoop microhardness tests. ANOVA and Tukey test (p<0.05) showed no statistically significant differences for the sorption test (p=0.915).The values in g/mm3 with their respective standard deviations were: g1=22.58±1.2; g2=22.28±2.26 and g3=22.78±2.02. The solubility test showed statistically differences among groups (p=0.006). The values in g/mm3 with their respective standard deviations were: g1 = 0.54±0.14B, g2=3.2±2.07A, and g3=2.16±1.06AB. The Knoop microhardness test showed no statistically significant differences among groups (p=0.106). The values in KHN with their respective standard deviations were: g1=62.12±0.86, g2=64.88±4.21 and g3=66.20±2.33. Taking into consideration the studied factors, it can be concluded that the size and the shape of photoactivation recommended by ISO 4049 seems to be the best way of preparing the specimens for sorption and solubility tests, associated with the Knoop microhardness test.
5

Avaliação da microdureza Knoop e do grau de conversão de dois cimentos de ionômero de vidro modificados por resina em função do tipo de polimerização e do tempo / Evaluation of the Knoop microhardness and the degree of conversion of two resin-modified glass ionomer in function of the type of polymerization and the time

Martins, Leandro de Moura 21 May 2007 (has links)
Os ionômeros de vidro vêm sendo utilizados largamente na odontologia com diversas funções. Suas formulações sofreram alterações durante os anos, como a incorporação de componentes resinosos, para a melhoria de suas propriedades físicas e aumento do tempo de trabalho. Com isso, o estudo teve como objetivo avaliar o grau de conversão e a microdureza Knoop dos cimentos de ionômero de vidro modificados por resina (Rely X Luting e Vitremer, ambos da 3M ESPE) de acordo a forma de polimerização (química ou fotopolimerável por lâmpada halógena Ultralux EL ? Gnatus e LED LEC 1000 ? MMOptics) e o tempo de armazenagem. Três espécimes de cada material, autopolimerizável e fotopolimerizável, e tipo de fotopolimerização (por luz halógena e LED) foram confeccionados para cada tempo experimental de 6 horas, 1, 2, 3, 5, 7 ,11 e 14 dias (n=72). Os espécimes foram armazenados em ambiente escuro a 37°C durante esses períodos. Os 72 espécimes foram analisados pela espectroscopia FT-IR para a medição do grau de conversão (GC). Três espécimes de cada material e tipo de polimerização (n=9) foram confeccionados para a medição da microdureza, com um penetrador diamantado piramidal, tipo Knoop, carga estática de 50 gramas por 30 segundos. Os resultados encontrados demonstraram que o material fotopolimerizado com LED apresentou os maiores valores do grau de conversão e da microdureza. O grau de conversão aumentou com o tempo de armazenagem enquanto a microdureza obteve os maiores resultados entre 24-48 horas. Os resultados permitiram concluir que para os cimentos de ionômero de vidro modificados por resina, Vitremer e Rely X Luting, o material fotopolimerizável onde se utilizou o LED apresentou os melhores resultados e que a microdureza Knoop foi ineficaz para predizer o grau de conversão. / Glass ionomer cement have been widely used for many functions. Over the years, some alterations have been made to improve some physico-mechanical properties and to prolong working time. The purpose of this study was to evaluate the relation of the degree of conversion (DC) and Knoop microhardness of resin modified glass ionomer cements (Rely X Luting and Vitremer - 3M ESPE) with polymerization type (chemical curing and light curing reactions, using halogen light or LED) and time of storage. Three specimens of each material, self-cured and light-cured, and light-curing type (halogen light or LED) were prepared for each period of time (n=72). Specimens were stored in dark and dry conditions, at 37oC, during 6 hours, 1, 2, 3, 5, 7, 11 and 14 days. All the specimens were analyzed by FT-IR spectroscopy to measure the DC. Three specimens of each material and polimeryzation type (n=9) were prepared for the microhardness determination, equipped with a Knoop indenter, 50g load for 30 seconds. Results showed that higher values of DC and Knoop microhardness were found on the LED light-cured material. DC values increased with storage time while the Knoop microhardness achieved its higher values between 24-48 hours. Results showed that the LED light-curing unit used to polymerize the resin modified glass ionomer cement Vitremer achieved better values of DC, between light and self-cured materials, and that the Knoop microhardness could not predict the DC.
6

"Diferentes métodos de otimização da polimerização de resinas compostas de uso direto" / Different methods in optimizing the polymerization of direct resin composites

Almeida, Ana Maria Lima 09 December 2005 (has links)
Este trabalho avaliou a influência da densidade de energia da pré-cura, e de diferentes tratamentos pós-cura na otimização das propriedades físicas (Resistência à Flexão e Dureza Knoop) de resinas compostas diretas, visando a possibilidade de indicação para restauraçoes indiretas. Foram usadas as resinas diretas Fillmagic, Concept, Glacier, Z100, Masterfill e W3D Master e as indiretas Solidex e Belleglass HP como controle. Para cada resina direta foram confeccionados 60 espécimes em barra (10x2x2mm), 30 irradiados em uma face e 30 nas duas faces (30 espécimes = 10 controle, 10 autoclave e 10 forno de luz). Para as resinas indiretas foram preparados 10 espécimes conforme processamento de seus fabricantes. 380 espécimes foram submetidos ao ensaio de resistência à flexão (Kratos). De cada condição experimental, 10 fragmentos foram usados para ensaio de microdureza Knoop (Shimadzu HMV-2). A análise de variância e o teste de Tukey demonstraram significância para resistência à flexão nos fatores Resina (p<0,001) e Tratamento (p=0,001) e na interação Resina x Tratamento (p=0,001). Para a microdureza Knoop os três fatores e as interações foram significantes: Resina (p=0,001); Face (p=0,001) Tratamento (p=0,017); Resina x Face (p=0,001); Resina x Tratamento (p=0,007); Face x Tratamento (p=0,001) e Resina x Face x Tratamento (p=0,024). A maior média de cada resina direta, independente da condição experimental, foi comparada às médias das resinas indiretas. Os resultados apontam que na resistência à flexão (Z100 = W3D = Fillmagic = Glacier) e (Z100 > Masterfill > Belleglass HP > Concept > Solidex). Na Dureza Knoop (Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill e Solidex). Conclusão: as propriedades físicas (resistência à flexão e dureza Knoop) não são obstáculos na indicação de resinas compostas de uso direto para restaurações indiretas / This study evaluated the influence of pre-cure energy density, and additional post-cure treatments in optimizing the physical properties (Flexural strength and Knoop microhardness) of direct resin composites with the aim at allowing their use for indirect restorations. Direct resin composites evaluated were Fillmagic, Concept, Glacier, Z100, Masterfill and W3D Master; indirect composites were Solidex and Belleglass HP. Sixty bar-shaped specimens (10x2x2mm) were prepared for each material, so that 30 of them were light-cured by one surface and 30 on both surfaces. From the 30 specimens of each group, 10 were control, 10 were submitted to additional autoclave and 10 to light oven treatment. Ten specimens were prepared with each indirect composite following the manufactures’ recommendations. The 380 specimens were submitted to flexural strength test (Kratos universal testing machine), and values obtained at fracture were reported. After that, 10 fragments were chosen for each experimental condition and assessed for Knoop microhardness (Shimadzu HMV-2). Data were submitted to analysis of variance and Tukey’s test at p<0.05. Statistically significant differences were found among flexural strength results regarding composite materials (p<0.001), treatments (p<0.001) and interactions (composite x treatment, p<0.001). Regarding Knoop microhardness, both three factors and their interactions were also significant: composite (p<0.001), surface (p<0.001) and treatment (p<0.017), composite x surface (p<0.001), composite treatment (p<0.001), surface x treatment (p<0.001) and composite x surface x treatment (p<0.024). The highest mean value for each direct composite, regardless of the experimental condition, was compared to the mean values obtained for the indirect materials. With regard to flexural strength, comparisons point out that Z100 = W3D = Fillmagic = Glacier and Z100 > Masterfill > Belleglass HP > Concept > Solidex, whereas for Knoop microhardness Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill and Solidex. Conclusion: considering the physical properties evaluated in this study, they are not an obstacle to the indication of direct composites for indirect restorations
7

Avaliação da microdureza Knoop e do grau de conversão de dois cimentos de ionômero de vidro modificados por resina em função do tipo de polimerização e do tempo / Evaluation of the Knoop microhardness and the degree of conversion of two resin-modified glass ionomer in function of the type of polymerization and the time

Leandro de Moura Martins 21 May 2007 (has links)
Os ionômeros de vidro vêm sendo utilizados largamente na odontologia com diversas funções. Suas formulações sofreram alterações durante os anos, como a incorporação de componentes resinosos, para a melhoria de suas propriedades físicas e aumento do tempo de trabalho. Com isso, o estudo teve como objetivo avaliar o grau de conversão e a microdureza Knoop dos cimentos de ionômero de vidro modificados por resina (Rely X Luting e Vitremer, ambos da 3M ESPE) de acordo a forma de polimerização (química ou fotopolimerável por lâmpada halógena Ultralux EL ? Gnatus e LED LEC 1000 ? MMOptics) e o tempo de armazenagem. Três espécimes de cada material, autopolimerizável e fotopolimerizável, e tipo de fotopolimerização (por luz halógena e LED) foram confeccionados para cada tempo experimental de 6 horas, 1, 2, 3, 5, 7 ,11 e 14 dias (n=72). Os espécimes foram armazenados em ambiente escuro a 37°C durante esses períodos. Os 72 espécimes foram analisados pela espectroscopia FT-IR para a medição do grau de conversão (GC). Três espécimes de cada material e tipo de polimerização (n=9) foram confeccionados para a medição da microdureza, com um penetrador diamantado piramidal, tipo Knoop, carga estática de 50 gramas por 30 segundos. Os resultados encontrados demonstraram que o material fotopolimerizado com LED apresentou os maiores valores do grau de conversão e da microdureza. O grau de conversão aumentou com o tempo de armazenagem enquanto a microdureza obteve os maiores resultados entre 24-48 horas. Os resultados permitiram concluir que para os cimentos de ionômero de vidro modificados por resina, Vitremer e Rely X Luting, o material fotopolimerizável onde se utilizou o LED apresentou os melhores resultados e que a microdureza Knoop foi ineficaz para predizer o grau de conversão. / Glass ionomer cement have been widely used for many functions. Over the years, some alterations have been made to improve some physico-mechanical properties and to prolong working time. The purpose of this study was to evaluate the relation of the degree of conversion (DC) and Knoop microhardness of resin modified glass ionomer cements (Rely X Luting and Vitremer - 3M ESPE) with polymerization type (chemical curing and light curing reactions, using halogen light or LED) and time of storage. Three specimens of each material, self-cured and light-cured, and light-curing type (halogen light or LED) were prepared for each period of time (n=72). Specimens were stored in dark and dry conditions, at 37oC, during 6 hours, 1, 2, 3, 5, 7, 11 and 14 days. All the specimens were analyzed by FT-IR spectroscopy to measure the DC. Three specimens of each material and polimeryzation type (n=9) were prepared for the microhardness determination, equipped with a Knoop indenter, 50g load for 30 seconds. Results showed that higher values of DC and Knoop microhardness were found on the LED light-cured material. DC values increased with storage time while the Knoop microhardness achieved its higher values between 24-48 hours. Results showed that the LED light-curing unit used to polymerize the resin modified glass ionomer cement Vitremer achieved better values of DC, between light and self-cured materials, and that the Knoop microhardness could not predict the DC.
8

"Diferentes métodos de otimização da polimerização de resinas compostas de uso direto" / Different methods in optimizing the polymerization of direct resin composites

Ana Maria Lima Almeida 09 December 2005 (has links)
Este trabalho avaliou a influência da densidade de energia da pré-cura, e de diferentes tratamentos pós-cura na otimização das propriedades físicas (Resistência à Flexão e Dureza Knoop) de resinas compostas diretas, visando a possibilidade de indicação para restauraçoes indiretas. Foram usadas as resinas diretas Fillmagic, Concept, Glacier, Z100, Masterfill e W3D Master e as indiretas Solidex e Belleglass HP como controle. Para cada resina direta foram confeccionados 60 espécimes em barra (10x2x2mm), 30 irradiados em uma face e 30 nas duas faces (30 espécimes = 10 controle, 10 autoclave e 10 forno de luz). Para as resinas indiretas foram preparados 10 espécimes conforme processamento de seus fabricantes. 380 espécimes foram submetidos ao ensaio de resistência à flexão (Kratos). De cada condição experimental, 10 fragmentos foram usados para ensaio de microdureza Knoop (Shimadzu HMV-2). A análise de variância e o teste de Tukey demonstraram significância para resistência à flexão nos fatores Resina (p<0,001) e Tratamento (p=0,001) e na interação Resina x Tratamento (p=0,001). Para a microdureza Knoop os três fatores e as interações foram significantes: Resina (p=0,001); Face (p=0,001) Tratamento (p=0,017); Resina x Face (p=0,001); Resina x Tratamento (p=0,007); Face x Tratamento (p=0,001) e Resina x Face x Tratamento (p=0,024). A maior média de cada resina direta, independente da condição experimental, foi comparada às médias das resinas indiretas. Os resultados apontam que na resistência à flexão (Z100 = W3D = Fillmagic = Glacier) e (Z100 > Masterfill > Belleglass HP > Concept > Solidex). Na Dureza Knoop (Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill e Solidex). Conclusão: as propriedades físicas (resistência à flexão e dureza Knoop) não são obstáculos na indicação de resinas compostas de uso direto para restaurações indiretas / This study evaluated the influence of pre-cure energy density, and additional post-cure treatments in optimizing the physical properties (Flexural strength and Knoop microhardness) of direct resin composites with the aim at allowing their use for indirect restorations. Direct resin composites evaluated were Fillmagic, Concept, Glacier, Z100, Masterfill and W3D Master; indirect composites were Solidex and Belleglass HP. Sixty bar-shaped specimens (10x2x2mm) were prepared for each material, so that 30 of them were light-cured by one surface and 30 on both surfaces. From the 30 specimens of each group, 10 were control, 10 were submitted to additional autoclave and 10 to light oven treatment. Ten specimens were prepared with each indirect composite following the manufactures’ recommendations. The 380 specimens were submitted to flexural strength test (Kratos universal testing machine), and values obtained at fracture were reported. After that, 10 fragments were chosen for each experimental condition and assessed for Knoop microhardness (Shimadzu HMV-2). Data were submitted to analysis of variance and Tukey’s test at p<0.05. Statistically significant differences were found among flexural strength results regarding composite materials (p<0.001), treatments (p<0.001) and interactions (composite x treatment, p<0.001). Regarding Knoop microhardness, both three factors and their interactions were also significant: composite (p<0.001), surface (p<0.001) and treatment (p<0.017), composite x surface (p<0.001), composite treatment (p<0.001), surface x treatment (p<0.001) and composite x surface x treatment (p<0.024). The highest mean value for each direct composite, regardless of the experimental condition, was compared to the mean values obtained for the indirect materials. With regard to flexural strength, comparisons point out that Z100 = W3D = Fillmagic = Glacier and Z100 > Masterfill > Belleglass HP > Concept > Solidex, whereas for Knoop microhardness Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill and Solidex. Conclusion: considering the physical properties evaluated in this study, they are not an obstacle to the indication of direct composites for indirect restorations
9

Efeito do tipo de fonte de luz sobre propriedades físicas de cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores / Effect of light curing units on the physical properties of experimental resin cements containing different photoinitiators systems

Leonardo Freitas da Silveira 25 March 2013 (has links)
Cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores apresentaram propriedades físicas semelhantes ou superiores a cimentos resinosos convencionais sob efeito de diferentes tipos de fonte de luz. Objetivo: Analisar o espectro de diferentes fontes de luz e sistemas fotoiniciadores e sua influência nas propriedades físicas de cimentos resinosos quando ativados, através de um anteparo cerâmico, por fontes de luz halógena e LED. Metodologia: Cimentos resinosos experimentais contendo uma mistura de BisGMA, TEGDMA (50wt%) e partículas de carga silanizadas (65wt%), foram preparados com o uso dos fotoiniciadores Canforoquinona (CQ), Fenil Propanodiona (PPD) e Óxido bis-alquil fosfínico (BAPO) de forma isolada e combinados. Os co-iniciadores utilizados foram Difenil Iodônio (DFIHFP) e a amina terciária DMAEMA. As fontes de luz utilizadas foram: lâmpada halógena (XL 2500) e duas fontes de diodo emissor de luz - LED (FreeLigth 2 e Bluephase). Um anteparo cerâmico (IPS e.max Press) apresentando 13,0mm x 1,0mm de espessura foi utilizado durante os testes. Amostras com 7,0mm x 2,0mm x 1,0mm foram confeccionadas (n=360). A avaliação do Grau de Conversão (GC) dos cimentos experimentais foi realizada por Espectroscopia de Infravermelho Transformada de Fourier (FTIR), sendo em seguida submetidas ao teste de resistência à mini-flexão, módulo flexural e microdureza Knoop. Os resultados obtidos em todos os testes foram submetidos à análise de variância dois fatores - ANOVA e teste de Tukey (5%). Resultados: A associação do DFIHFP aos fotoiniciadores aumentou as propriedades avaliadas de todos os cimentos experimentais independente da fonte de luz (FL) utilizada. O fotoiniciador BAPO apresentou resultados superiores ou iguais estatisticamente em comparação ao grupo controle (CQ/amina), independente da FL utilizada. Conclusão: A utilização de sistemas iniciadores e co-iniciadores alternativos possibilita a obtenção de propriedades superiores ou iguais ao sistema convencional, tornando-se um sistema promissor para atuar de forma isolada ou associada. / Resin cements containing different experimental photoinitiators systems present physical properties similar to or better than conventional resin cements under the effect of different types of light source. Objective: To analyze the spectrum of different light sources and systems photoinitiators and their influence on physical properties of resin cements when activated through a bulkhead ceramic, halogen light sources and LED. Methodology: experimental resin cements containing a mixture of BisGMA, TEGDMA (50wt%) and silanized filler particles (65wt%) were prepared with the use of photoinitiators camphorquinone (CQ), phenyl oxide bis-propanedione (PPD) and alkyl phosphinic (BAPO) separately and combined. The primers used were co-diphenyl iodonium (DFIHFP) tertiary amine and DMAEMA. The light sources used were: halogen lamp (XL 2500) and two sources of light emitting diode - LED (FreeLigth bluephase and 2). A ceramic shield (IPS e.max Press) having 13.0mm x 1.0mm thick was used for testing. Samples with 7.0mm x 2.0mm x 1.0mm were fabricated (n=360). The evaluation of the degree of conversion (GC) of experimental cements was performed by Infrared Spectroscopy Fourier Transform, and then to test for resistance to mini-bending, flexural modulus and microhardness. The results in all tests were subjected to two-factor analysis of variance - ANOVA and Tukey test (5%). Results: The combination of photoinitiators DFIHFP to improve board properties of all the experimental cements independent light source (LCU) used. The photoinitiator BAPO showed statistically equal or better results compared to the control group (CQ / amine), regardless of LCU used. Conclusion: The use of systems co-initiators and initiators to obtain alternative provides equal or better properties to the conventional system, making it a promising system to act in isolation or in combination.

Page generated in 0.0309 seconds