• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 410
  • 23
  • 23
  • 23
  • 23
  • 16
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 418
  • 418
  • 154
  • 108
  • 99
  • 92
  • 73
  • 50
  • 49
  • 45
  • 40
  • 40
  • 39
  • 36
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Fadiga dinamica em fibras oticas

Lucas, Max Antonio Ramos 22 November 1985 (has links)
Orientador : Ricardo Enrique Medrano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-16T09:01:01Z (GMT). No. of bitstreams: 1 Lucas_MaxAntonioRamos_M.pdf: 1263993 bytes, checksum: 0b378bfe7c62d6f44b0d3bbf6ecca75d (MD5) Previous issue date: 1985 / Resumo: A fadiga das fibras ópticas é um dos principais fatores a serem analisados em projetos de cabos Ópticos. Este fenômeno resume-se no crescimento de fissuras através de ataques químicos, sendo os ions da água o principal causador deste crescimento.Vários autores já apresentaram trabalhos sobre o assunto, selecionando previamente as amostras mais resistentes e extrapolando lineannente estes dados para tempos altos (20 anos) e tensões pequenas. Questionando este procedimento, nós elaboramos um experimento que não selecionou previamente as amostras, de forma a dividir o conjunto de dados em grupos de amostras fracas, médias e mais resistentes. De posse destes dados, podemos estabelecer uma comparação da relação tensão versus tempo para os três conjuntos de dados e verificar se mantém a linearidade da curva de fadiga para tempos altos / Abstract: Fatigue of optical Fibers is one of the factors that should be analysed in a optical cable project. This phenornenon can be resumed in the grow of flaws, through chemical attack. Ions of water are mainly responsible for this processo. Several papers on the subject are presently available, where the authors are dealing wi th the case of high strength samples. They extrapolate linearly their data to long times (twenty years) and low stress. Contrary to this procedure we perfonn an experiment, without selecting the strength of the samples. We divide the data in three groups of low, medium and high strenth samples. From our set of data, we can establish a comparison of the relation between stress and time for the above three group of data and verify if the lineari ty of the fatigue curve for long times is satisfied / Mestrado / Mestre em Engenharia Mecânica
72

Conformabilidade plastica de fios capilares de ouro na trefilação

Zavaglia, Cecília Amélia de Carvalho, 1954- 24 August 1988 (has links)
Orientador: Ettore Bresciani Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-16T20:08:12Z (GMT). No. of bitstreams: 1 Zavaglia_CeciliaAmeliadeCarvalho_D.pdf: 11187327 bytes, checksum: 1e25a5d6da305701d7f3b8cb258653ec (MD5) Previous issue date: 1988 / Resumo: Este trabalho tem COIID principal objetivo estudar a conformabilidade na trefilação de fios capilares de ouro. Associando-se os conhecimentos sobre a mecânica da conformação, sobre as propriedades do material e sobre os critérios de fratura dúctil, pode-se estabelecer critérios de conformabilidade. A primeira etapa deste trabalho consistiu no desenvolvimento de equipamentos e dispositivos para a obtenção de fios capilares por trefilação. Na segunda etapa foram estudados os mecanismos de fratura dúctil na trefilação de fios de ouro e foram estabelecidos critérios de conformabilidade. Esses critérios foram aplica dos às condições de processamento adotadas neste trabalho. Algumas sugestões foram feitas visando minimizar a ocorrência de rupturas. / Abstract: The main goal of this work is to study workability of u1trafine gold wires in wiredrawing. Putting together the fundamentals of Irechanical plasticity, material properties and ductile fracture criteria , it may be established the workability criteria. The first part of this work involved the development of drawing machines. The second part was the study of the ductile fracture mechanisms of the wires and the establishement of workability criteria , which were applied to the process conditions of this work. Some suggestions were done in order to avoid wire breaks. / Doutorado / Doutor em Engenharia Mecânica
73

Analise de retardo na propagação de trincas de fadiga em uma chapa de aluminio 2024-T3 submetida a carregamentos de amplitude variavel

Pinto Junior, Carlos Carvalho Engler, 1965- 24 May 1989 (has links)
Orientador: Ana Maria Martinez Nazar / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-16T21:35:15Z (GMT). No. of bitstreams: 1 PintoJunior_CarlosCarvalhoEngler_M.pdf: 4199608 bytes, checksum: 9f6c06ae97977693a2ecec513035fb2d (MD5) Previous issue date: 1989 / Resumo: A maior parte das falhas de estruturas metálicas particularmente na indústria aeronáutica, é devido à ação de cargas cíclicas (fadiga), que podem provocar o surgimento e a propagação de trincas no material. Quando o espectro de cargas apresenta amplitudes variáveis, ocorrem efeitos de interação entre a "história dq carregamento" (sequência de aplicação das cargas) e a taxa de propagação da trinca. Dentre estes efeitos de interação, o mais importante é o retardo na propagação da trinca, que pode aumentar consideravelmente a vida útil da estrutura trincada. O objetivo principal deste trabalho é analisar e quantificar o retardo na propagação de trincas em uma chapa fina da liga de alumínio de alta resistência 2024- T3, comparando os modelos matemáticos existentes para representar este fenômeno. Foram realizados ensaios do tipo sequencial alto-baixo, para diferentes tamanhos dê trinca e relação de sobrecarga (Rsc = Kmaxa/ Kmaxb). Verificou-se experimentalmente que o retardo é proporcional à Rsc, e que o efeito do retardo permanece pelo menos até que a ponta da trinca atinja o fim da zona plástica induzi da pela carga alta. Uma comparação dos resultados experimentais com os modelos de Willemborg e Wheeler mostrou que estes não representam de maneira correta o comportamento da trinca. Foi desenvolvida uma expressão para corrigir o tamanho da zona plástica para condições intermediárias entre tensão plana e deformação plana. Com esta expressão corrigida, foi possível desenvolver um modelo simplificado, baseado na teoria das tensões de fechamento da trinca, que conseguiu representar muito bem o comportamento da trinca durante o retardo, principalmente para condições de tensão plana. Finalmente, foi constatado que a teoria das tensões de fechamento também é capaz de prever as condições de parada total no crescimento da trinca. / Abstract: The majority of failures in metallic structures, especially in the aeronautic industry, are due to cyclic loads (fatigue), which can nucleate and propagate cracks through the material. In variable amplitude loading, there are interaction effects between the loading history and the crack propagation rate. The most important of those effects is the retardation in the crack propagation, that may raise considerably the life of the cracked structure. The main objective or this research is to analyse and quantify the retardation of crack propagation in a thin plate of the high-resistance aluminum alloy 2024- T3, comparing the results obtained from the mathematical models proposed to account for the retardation effect. The specimens were tested under a high-Iow loading sequence, for different crack sizes and overload ratios (RoI = Kmaxh / Kmax,). It was verified that the retardation is proportional to Rol, and that the models of Willemborg and Wheller couldn't represent correctly the crack behaviour after the transition to the low level loads, because the retardation was observed at least until the crack tip reached the end of the plastic zone due to the high loads. It was proposed an expression to correct the plastic zone size for conditions between plane stress and plane strain. With that corrected expression, and based on crack closure theory, it was proposed a simplified model, that represent with good precision the crack behaviour during retardation, particularly for plane stress conditions. Finally, it was also verified that the crack closure theory allows the prediction of crack arrest conditions. / Mestrado / Mestre em Engenharia Mecânica
74

Relaxação de tensões em metais

Penna, Thereza Christina Robalinho, 1945- 23 July 1981 (has links)
Orientador: Ricardo Enrique Medrano / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-16T22:08:15Z (GMT). No. of bitstreams: 1 Penna_TherezaChristinaRobalinho_D.pdf: 2374112 bytes, checksum: 5f7dff8cc0ab6a3a6c1dcd7aa655b9e9 (MD5) Previous issue date: 1981 / Resumo: Qualquer metal ou liga metálica que tenha sido mecanicamente solicitado a um certo nível de tensão, correspondente a uma dada deformação, experimentará um decréscimo gradual com o tempo se a deformação for mantida constante. Este fenômeno denominado Relaxação de Tensão, de interesse tanto prático quando fundamental, oferece um meio para estudar a deformação dinâmica dos metais. Neste trabalho estudou-se a importância do efeito da relaxação do sistema deformante bem como o significado das experiências realizadas em máquinas servohidráulicas com o uso do controle de deformação ou de deslocamento. Várias equações relacionando tensão aplicada e taxa de deformação foram utilizadas, na análise das experiências, realizadas a temperatura ambiente, em zinco e cobre. Através dessas equações fez-se um estudo do parâmetro b que relaciona tensão e taxa de deformação para se verificar se a subestrutura de deslocações permanecia constante durante a relaxação de tensão. Com base nesses cálculos discutiu-se a validade de vários testes de relaxação que aparecem na literatura cientifica. Fez-se também um estudo dos parâmetros obtidos pelo método de Li na relaxação. O cálculo da tensão interna através de uma lei de potência é questionado apesar da boa concordância dos resultados experimentais com a aplicação do método de Li . Analisou-se também o conceito de equação plástica de estado por meio de experiências de relaxação discutindo-se o seu uso quando ocorre recuperação ou envelhecimento / Abstract: Any metal or alloy which is submitted to a stress level, corresponding to a given strain, will gradually relax if this strain is maintained constant. This effect which is named Stress Relaxation offers means to investigate the dislocation dynamics of metals. One objective of the present investigation was to study the machine's contribution on the stress relaxation tests by using a servohydraulic system with either strain or stroke control mode. Several equations relating stress rate and stress are applied to the experimental analysis, which were conducted at room temperature, on Cu and zinc specimens. By means of these equations we have studied the parameter b relating stress and strain rate, in order to verify if the dislocation structure remains constant in the relaxation tests. The parameters obtained by Li¿s analysis were also studied. We have questioned the internal stress obtained in this way, even if we have an apparent good agreement of the experimental results with the application of Li¿s method. Stress relaxation experiments were used to obtain experimental data to study the concept of plastic equation of state and to show that the conclusions made by some authors may be questioned when recovery occurs / Doutorado / Física / Doutor em Ciências
75

Comparação da resistência de união à microtração de sistemas cerâmicos odontológicos bilaminares

Fracasso, Lisiane Martins January 2014 (has links)
Made available in DSpace on 2014-03-15T02:01:32Z (GMT). No. of bitstreams: 1 000454706-Texto+Completo-0.pdf: 713974 bytes, checksum: b4c4d030b32ac428abd2ac68d41fed1c (MD5) Previous issue date: 2014 / The introduction of ceramics in dentistry occurred since the eighteenth century through the use in complete denture. Bilayered systems composed by metal and ceramic emerged from the 60s and the interest in ceramic systems composed by a ceramic infrastructure that provides resistance associated with an aesthetic cover ceramic becomes evident in the last decades of the past century. Thus, different types of ceramics were inserted in the dental commerce. The aim of this study was to evaluate the microtensile bond strength of three systems of all-ceramics: E- max Press, In-Ceram Zirconia and Mark II with its respectively veneering porcelain. Samples were prepared by using a conformer of ceramic samples and included in the center of a ring of polyvinyl chloride (PVC). Three samples of each system were cut into microbars of a square millimeter in cross section. Five specimens of each sample were randomly selected for the microtensile bon strength test (n = 14). An Universal Testing Machine with 0,5mm/min was used for the microtensile bond strength test. Data were statistically analyzed using the G * Power 3. 1. 7 software. The distribution of normality was analyzed using the Shapiro-Wilk test (E- max Press, p = 0,96; In-Ceram Zirconia, p = 0,25, Mark II, p = 0,56). There were no homogeneity between samples when was used Levene test (p = 0,01). For this reason, the data were submitted to analysis of variance test followed by multiple comparison Games-Howell test. There was statistically significant difference between groups (p = 0,01), and E-max Press (17,88a ± 5,92 MPa) showed higher resistance to the other groups, followed by Mark II (12,98b ± 4,21 MPa) and In-Ceram Zirconia (9. 44c ± 2. 25 MPa). Therefore, there is a significant difference between the union of infrastructure and coverage in the different systems, which may influence longevity of these restorations. / A introdução das cerâmicas na odontologia ocorreu a partir do século XVIII através da utilização das mesmas em prótese total. Sistemas bilaminares compostos por metal e cerâmica surgiram a partir da década de 60 e o interesse por sistemas cerâmicos bilaminares compostos por uma cerâmica de infra-estrutura que proporciona resistência associada a uma cerâmica de cobertura que oferece estética torna-se evidente nas últimas décadas do século passado. Assim, diversos tipos de cerâmicas foram introduzidas no mercado odontológico.O objetivo deste estudo foi avaliar a resistência à microtração de três sistemas de cerâmicas puras: E-max Press, In-Ceram Zircônia e Mark II com as respectivas cerâmicas de cobertura de cada sistema. As amostras foram confeccionadas através da utilização de um conformador de amostras de cerâmicas e incluídas no centro de um anel de policloreto de vinila (PVC). Três amostras de cada sistema foram cortadas em palitos de um milímetro quadrado em sua secção transversal. Cinco corpos-de-prova de cada amostra foram selecionados aleatoriamente para o teste de microtração (n = 14). Para o ensaio de microtração foi utilizada uma Máquina de Ensaio Universal com velocidade de 0,5mm/min. Os dados obtidos foram analisados estatisticamente através do software G* Power 3. 1. 7. A distribuição de normalidade foi verificada com o teste Shapiro-Wilk (E-max Press, p = 0,96; In-Ceram Zircônia, p = 0,25; Mark II, p = 0,56). Não foi verificada homogeneidade entre as amostras através do teste de Levene (p = 0,01). Portanto, os dados foram submetidos ao teste de Análise de Variância seguido de teste de Comparações Múltiplas Games-Howell. Foi registrada diferença estatisticamente significativa entre os grupos (p = 0,01), sendo que E-max Press (17,88a ± 5,92 MPa) apresentou resistência a microtração superior aos demais grupos, seguido de Mark II (12,98b ± 4,21 MPa) e In-Ceram Zircônia (9,44c ± 2,25 MPa). Portanto, verifica-se uma diferença significativa entre a união das cerâmicas de infra-estrutura e cobertura nos diferentes sistemas, o que poderá influenciar na longevidade clínica destas restaurações.
76

Influência do tratamento superficial e da ciclagem mecânica na resistência de união ao cisalhamento entre cerâmica feldspática e resina composta fotopolimerizavel

Dondoni, Marilson January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:24Z (GMT). No. of bitstreams: 2 000430600-0.pdf: 1425866 bytes, checksum: a6284b0edf71e30994f389b10f22f4b4 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Ceramic is the best restorative material properties used in cosmetic dentistry. Associated with a esthetics, numerous other properties make this material embodied in restorative dentistry. However, the ceramic has a high potential as a limitation of fracture. Total replacement of a fractured restoration is often impossible, especially when the prosthesis is well adapted and the fracture is not extensive. Thus, one can resort to repair the fractured ceramic surface intra-orally with composite resin. This study aimed to evaluate the influence of surface treatment and mechanical cycling on shear bond strength between feldspathic porcelain and composite resin. The surface treatments used were tipped Damant roughening, etching, blasting with aluminum oxide or the combination of sandblasting etching. It was concluded that for an index of 95%, both surface treatments used and mechanical cycling did not influence the bond strength between feldspathic porcelain and composite resin. / A cerâmica é o material restaurador com melhores propriedades estéticas utilizado na odontologia. Associada a estética, outras inúmeras propriedades tornam esse material consagrado na odontologia restauradora. Porém, a cerâmica possui como limitação um alto potencial de fratura. A substituição total de uma restauração fraturada muitas vezes é inviável, principalmente quando a prótese está bem adaptada e a fratura não é extensa. Com isso, pode-se lançar mão de reparar a superfície da cerâmica fraturada intra-oralmente com resina composta fotopolimerizável. Este estudo teve o objetivo de avaliar a influência do tratamento superficial e da cilcagem mecânica na resistência de união ao cisalhamento entre cerâmica feldspática e resina composta fotopolimerizável. Os tratamentos superficiais utilizados foram: asperização com ponta damantada, condicionamento ácido, jateamento com óxido de alumínio e associação de jateamento com condicionamento ácido. Concluiu-se que para um índice de confiança de 95%, tanto os tratamentos superficiais utilizados, assim como a ciclagem mecânica, não exerceram influência na resistência de união entre cerâmica feldspática e resina composta fotopolimerizável.
77

Análise da resistência ao cisalhamento de reparos em cerâmicas após diferentes tratamentos de superfície

Bettinelli, Juliana Doncatto January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-03-27T11:14:53Z No. of bitstreams: 1 446575.pdf: 1714245 bytes, checksum: 92b3a7a5b5c9c607087a2af823b53843 (MD5) / Made available in DSpace on 2013-03-27T11:14:53Z (GMT). No. of bitstreams: 1 446575.pdf: 1714245 bytes, checksum: 92b3a7a5b5c9c607087a2af823b53843 (MD5) / Com a crescente preocupação na Odontologia com a estética, têm-se desenvolvido vários tipos de sistemas cerâmicos. Contudo, convém lembrar que, apesar das excelentes características estéticas e de biocompatibilidade, a cerâmica é um material friável incapaz de suportar deformação plástica sob tensão. Reparos em resina composta podem evitar a substituição de uma prótese com fratura. O objetivo deste trabalho foi verificar a resistência ao cisalhamento de reparos em cerâmica após diferentes tratamentos. O ácido hidrofluorídrico e o jateamento com óxido de alumínio são comumente usados nos tratamentos de superfície na clínica diária. O laser de baixa potência tem sido utilizado em tratamentos odontológicos visando melhorar o reparo cicatricial nos tecidos, porém este estudo avaliou resultados na irradiação de um laser de baixa intensidade utilizado como tratamento de superfície em cerâmicas. Quarenta discos de cerâmica, divididos em quatro grupos e com ( n=10) foram confeccionados com a cerâmica Noritake EX-3 (Grupos E) e outros quarenta discos, foram confeccionados com o sistema Noritake Cerabien (Grupos C). Os discos de cerâmica foram confeccionados a partir de uma matriz bipartida de politetrafluoretileno (PTFE) e incluídos individualmente no centro de um anel de policloreto de vinila (PVC), utilizando-se resina acrílica autopolimerizável. Os grupos foram divididos aleatoriamente de acordo com o grupo: Grupo E1 e C1: aplicação do laser, Grupo E2 e C2: condicionamento com ácido hidrofluorídrico 10%, Grupo E3 e C3: jateamento com óxido de alumínio, Grupo E4 e C4: asperização com carbeto de silício granulação # 400 (controle). Todos os discos de cerâmica foram padronizados com asperização com carbeto de silício granulação # 400, receberam aplicação de uma camada de agente união para cerâmica (Silano, Dentsply, Petrópolis, RJ, Brasil) e uma camada de adesivo (Single Bond 2 – Adhesive, 3M ESPE, St. Paul, MN, EUA). No centro do disco de cerâmica, foi confeccionado um bloco em resina composta microhíbrida (Charisma, Heraeus kulzer, Hanau, Alemanha). Cada grupo foi mantido a 100% de umidade a 37ºC por uma e quatro semanas na estufa para cultura. Para os ensaios de resistência ao cisalhamento foi utilizada a Máquina de Ensaio Universal modelo DL 2000 (EMIC, São José dos Pinhais, PR, Brasil). Os dados obtidos foram analisados estatisticamente com auxilio do SPSS 17.0 e análise de variância com medidas repetidas seguida do teste de Bonferroni. O jateamento com óxido de alumínio apresentou os maiores valores à resistência ao cisalhamento na interface entre a resina composta e a cerâmica EX3; e o mesmo ocorreu na cerâmica Cerabien; porém a cerâmica EX3 com o tempo de armazenagem de 1 semana e a cerâmica Cerabien com o tempo de armazenagem de 4 semanas. O jateamento com óxido de alumínio foi o tratamento superficial que apresentou melhores resultados nos dois tipos de cerâmicas de cobertura pesquisadas. O tempo de armazenagem de 4 semanas não teve influência significativa neste estudo. / With growing concern with aesthetics in dentistry, have developed various types of ceramic systems. However, remember that, despite the excellent aesthetic characteristics and biocompatibility of the ceramic material is friable unable to withstand plastic deformation under stress. Repairs composite resin can prevent the replacement of a prosthetic fracture. The aim of this study was to determine the shear strength of ceramic repairs after different treatments. The low level laser has been used in dental treatments aiming at improving the cicatricial repair tissue, however this study evaluated results in irradiation of a low intensity laser surface treatment as used in ceramics. The hydrofluoric acid and blasting with aluminum oxide are commonly used in surface treatments in clinical daily. Forty ceramic discs were divided into four groups and with (n = 10) were prepared with the ceramic Noritake EX-3 (Groups E) and another forty discs, were made with the system Noritake Cerabien (Group C). The ceramic discs were fabricated from a metallic mold polytetrafluoroethylene (PTFE) and included individually at the center of a ring of polyvinyl chloride (PVC), using acrylic resin. The groups were divided according to the group: Group E1 and C1: laser application, Grupo E2 and C2: etching with hydrofluoric acid 10%, Group E3 and C3: blasting with aluminum oxide, Group E4 and C4: roughened with carbide silicon grit # 400 (control). All ceramic discs were standardized with roughened with silicon carbide grit # 400, received application of a layer of union agent for ceramics (Silano, Dentsply, Petrópolis, RJ, Brazil) and a layer of adhesive (Single Bond 2 - Adhesive, 3M ESPE, St. Paul, MN, USA). In the center of the disk ceramic block was manufactured in composite microhybrid (Charisma, Heraeus Kulzer, Hanau, Germany). Each group was maintained at 100% humidity at 37 ° C for one to four weeks in an oven to culture. For tests on shear was used Universal Testing Machine Model DL 2000 (EMIC, São José dos Pinhais, PR, Brazil). Data were statistically analyzed with the aid of SPSS 17.0 and analysis of variance with repeated measures followed by the Bonferroni test. The blasting with aluminum oxide showed the highest resistance to shear at the interface between the composite and ceramic EX3, and the same occurred in Cerabien pottery, but pottery EX3 with the storage time of 1 week and ceramic Cerabien with time storage of 4 weeks. The blasting with aluminum oxide surface treatment that was presented better results in both types of ceramics coverage surveyed. The storage time of 4weeks had no significant influence in this study.
78

Características de resistência ao cisalhamento de rochas fraturadas. / Sem título em inglês

Fujimura, Fernando 17 November 1981 (has links)
A presente dissertação enfoca as características de resistência ao cisalhamento e os mecanismos básicos que governam o fenômeno de atrito em rochas fraturadas. Especial atenção é dedicada à identificação de fatores geométricos e geotécnicos importantes e a sua relação com o comportamento e esforços resistentes de rochas fraturadas. A caracterização de fraturas por meio de parâmetros geomecânicos adequados permitirá incluí-los nos modelos de cálculo e simular mais realisticamente o comportamento geomecânico do maciço rochoso fraturado. / This thesis focuses on the shear strenght and mechanisms that change the shear characteristics of jointed rocks. Special attention was devoted to the identification of geometric and geotechnical factors and its relationship with the behavior and strenght of jointed rocks. The characterization of the fractures by apropriated geomechanical parameters Will permite to include them in the models and to simulate more realistically the behavior of fractured rock mass.
79

Durabilidade de união e carga cíclica para falha do silicato de litío reforçado por zircônia após cimentação adesiva /

Diniz, Vandeberg. January 2018 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Tarcísio José Arruda Paes Júnior / Banca: Laís Regiane da Silva Concílio / Resumo: No presente trabalho, avaliou-se o efeito de diferentes concentrações de ácido fluorídrico (5% e 10%), na resistência de união entre uma cerâmica de silicato de lítio reforçado por zircônia (sem cristalização adicional, com queima de glaze e com queima adicional de cristalização) e um cimento resinoso, com e sem envelhecimento. Avaliou-se também o comportamento em fadiga de uma cerâmica à base de silicato de lítio reforçado por zircônia (sem cristalização adicional, com de queima de glaze e com queima adicional de cristalização) cimentada adesivamente a um material análogo a dentina (NEMA G10), na ausência ou presença de envelhecimento. Para o teste de microtração os blocos cerâmicos de silicato de lítio reforçado por zircônia foram cortados em blocos menores e divididos aleatoriamente em 12 grupos (N = 72; n = 6). No teste de fadiga os espécimes foram em formato de discos (diâmetro de 12 mm e espessura de 1,2 mm) cimentados a discos de resina epoxi Nema G10 (diâmetro de 12mm e espessura de 2,3mm), divididos em 6 grupos (N = 120; n = 20) e submetidos a ensaio de fadiga pelo método da escada (100.000 ciclos, 20 Hertz de frequência). Os dados resistência de união (MPa) e fadiga (N) foram submetidos à ANOVA 2-fatores, e respectivamente submetidos aos testes de Tukey e Bonferroni (p<0,05). Os resultados mostraram diferença estatisticamente significante para o fator "termociclagem" (ANOVA 2 fatores, p<0,05) sendo os grupos sem termociclagem superiores aos grupos com envelhecimento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : This study evaluated the effect of different hydrofluoric acid concentrations (5% and 10%) on the bond strength between a zirconium-reinforced lithium silicate ceramic (without additional crystallization, glaze firing and additional crystallization firing) and a resinous cement, with and without aging. The fatigue behavior of a zirconium-reinforced lithium silicate-based ceramic (without additional crystallization, glaze firing and additional crystallization firing) adhesively cemented to a material like dentin (NEMA G10) was also evaluated with or without thermal aging. For the microtensile test, the zirconia reinforced lithium silicate ceramic blocks were cut into smaller blocks and randomly divided into 12 groups (N=72; n=6). In the fatigue test, discs (diameter 12 mm and thickness 1.2 mm) were cut, cemented to NEMA G10 epoxy resin discs (diameter 12 mm and thickness 2.3 mm), assigned into 6 groups (N=120, n=20) and subjected to the fatigue test by the ladder method (100,000 cycles, 20 Hertz frequency). The bond strength (MPa) and fatigue (N) data were submitted to 2-Way ANOVA, and respectively submitted to Tukey and Bonferroni tests (p <0.05). The results showed a statistically significant difference for the "thermocycling" factor (2-Way ANOVA, p <0.05), with the groups without thermocycling been superior to the aged groups (Tukey). The Bonferroni test indicated that within the same condition (with or without thermocycling), the groups with additional crystallization or glaze firing showed higher results than the groups without additional firing. Thus, the bond between ZLS and the resin cement was negatively affected by thermal aging in water. On the other hand, the fatigue behavior of ZLS discs cemented on NEMA G10 was higher in the groups that received glaze or crystallization firing and lower in the aged groups...(Complete abstract click electronic access below) / Mestre
80

Influência do volume do preparo oclusal para inlays e do material restaurador na distribuição de tensão e resistência à fratura de pré-molares /

Costa, Anna Karina Figueiredo. January 2012 (has links)
Orientador: Alexandre Luiz Souto Borges / Coorientador: Pedro Yoshito Noritomi / Banca: Eduardo Shigueyuki Uemura / Banca: Rander Pereira Avelar / Resumo: O estudo avaliou a influência da dimensão do istmo oclusal do preparo em inlays na distribuição de tensões e resistência à fratura de pré-molares superiores humanos restaurados com diferentes tipos de materiais. Foram selecionados 49 dentes hígidos e separados em 7 grupos (n=7) de acordo com o volume do preparo: conservador ou extenso e material restaurador: cerâmica ou resina, tendo como controle os grupos I (Integro - controle positivo), PC (Preparo Conservador) e PE (Preparo Extenso), ambos controles negativos. Os demais grupos foram separados de acordo com o tipo de mateiral da Restauração: RCR- inlay Conservador + Resina indireta Signum Ceramis (Heraeus); RCC-inlay Conservador + Cerâmica e.max Press; RER-inlay Extensa + Resina composta Signum Ceramis e REC -inlay Extensa + Cerâmica e.max Press. Os dentes preparados foram moldados e os modelos confeccionados e enviados ao laboratório para a confecção das inlays. Todas as restaurações foram cimentadas com cimento resinoso, e armazenadas em ambiente úmido por 24 h. Os corpos de prova foram submetidos ao ensaio de resistência à fratura em máquina de ensaio universal a uma velocidade de 0,5 mm/min, por meio de uma ponta aplicadora de 10 mm de diâmetro que possuia contatos exclusivamente nas vertentes triturantes das cúspides vestibular e lingual. Todos os fraguimentos foram analisados com estereomicroscópio para o mapeamento das fraturas. Os dados obtidos foram submetidos ao teste ANOVA e Tukey em um nível de significância de 5% . Para a análise da distribuição de tensão e deslocamento um pré-molar birradicular foi modelado com dimensões médias da literatura e analisados por elementos finitos. No ensaio in vitro, o grupo I (161,73±22.94) apresentou valores médios de resistência à compressão, seguido... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The porpose of this study was to evaluate the influence of the size of the occlusal isthmus preparation of inlays, stress and displatimant distribution on fracture toughness of upper human premolars restored by two different materials. They were selected 49 intact teeth and separated into seven groups (n = 7). In accordance to the volume of Preparation: Extensive and Conservative, or Restorative material: Ceramic or Resin, with the control groups I (positive control), PC and PE (negative control). The other groups were divided into: RCR-conservative inlay + indirect resin Signum Ceramis (Heraeus), RCC- conservative inlay + e.max Press ceramic; RER-extensive inlay + indirect resin Signum Ceramis and REC- extensive inlay + e.max Press ceramic. The teeth were prepared by special controled device and the model cast was sent to the laboratory for the preparation of inlays. The restorations were cemented with resin cement. All groups were subjected to a resistance to fracture test in a universal testing machine at a cross speed of 0.5 mm / min, by the tip of 10 mm in diameter, only contact teeth . The slices was evaluated by stereomicroscopy and made the mapping of fractures. It was used the statistical analysis of variance and Tukey's test. For the analysis of stress distribuition and displacment of cuspal teeth, one upper premolar was modeled with average dimensions of the literature and analyzed by finite emement method. In the in vitro assay, the group I (161.73±22.94) showed mean values of compressive strength, followed by REC (103.55±15.84), RCC (94.38±12.35), RCR (90.31±6.10), RER (65.42±10.15), PC (65.46±5.37), PE (58.08±9.62). The stress distribution was different in all groups studied, and the tooth with extensive preparation showed higher concentration of tensile stress on the cervical region of the proximal... (Complete abstract click electronic access below) / Mestre

Page generated in 0.1471 seconds