• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Resistência à tração de retentores intra-radiculares fundidos sumetidos ao acabamento após cimentação com fosfato de zinco

Iglésias, Michele Andréa Lopes 11 July 2007 (has links)
The refinement of the coronary portion of the intraradicular post cemented constitutes in routine in the clinic. However, the effects of the action of the diamond burn in high rotation on the cement agent are little argued. This study is tested the hypothesis of that the refinement with high rotation an the passed time between the cementation and the accomplishment of the refinement have negative effect in the tensile strength of the intraradicular post cemented in bovine roots. Forty eight bovine roots have been parted with 15mm of length, endodontically treated, confectioned in Cu-Al league, cemented with cement zinc phosphate and divided in 4 experimental groups (n=12). Group A: Without refinement; Group B, C e D submitted the refinement 15, 60 minutes and 24 hours respectively, after the cementation. The assay was carried through in universal machine (EMIC) with speed of 0,5mm/min for all the groups 24 hours after the cementation. The data of tensile strength had been analyzed by the analysis of the variance and test of Bartlet (α=1%). Verified that it did not have significant difference between the groups. Inside of the limitation of this study it can be concluded that the refinement with high rotation and the factor passed time between the cementation and assay did not produce effect of the resistance of the intraradicular posts. / O acabamento da porção coronária do retentor intra-radicular fundido após cimentação constitui-se rotina na clínica odontológica. Entretanto, os efeitos da ação da ponta diamantada em alta rotação sobre o agente cimentante são pouco avaliados. Este estudo testou a hipótese de que o tempo decorrido entre a cimentação e a realização do acabamento com alta rotação tenha efeito negativo na resistência à tração dos retentores intra-radiculares fundidos. Quarenta e oito raízes bovinas foram seccionadas com 15 mm de comprimento, tratadas endodonticamente e divididas aleatoriamente em quatro grupos (n=12): n=A: não submetidos ao acabamento; n=B, C e D submetidos ao acabamento com os tempos de 15, 60 minutos e 24 horas respectivamente, após a cimentação. Os condutos foram moldados pela técnica direta para a obtenção de retentores com 11 mm de comprimento intra-radicular, fundidos em cobre-alumínio, jateados com óxido de alumínio e cimentados com fosfato de zinco. O ensaio de tração foi realizado em máquina universal (EMIC) com velocidade de 0,5mm/min para todos os grupos 24 horas após a cimentação. Os resultados foram submetidos à análise de variância e teste de Bartlet (α=1%). Não houve diferenças estatisticamente significantes na resistência à tração nos grupos controle e os grupos com acabamento após a cimentação, independente do período de espera. Dentro das limitações deste estudo concluiu-se que o acabamento com alta rotação e o tempo decorrido entre a cimentação e o ensaio não produziu efeito sobre a resistência dos retentores intra-radiculares fundidos em cobre-alumínio. / Mestre em Odontologia
12

Estudo das tensões em dente restaurado com coroa metalocerâmica e dois formatos de retentores intra-radiculares - método dos elementos finitos. / Finite element analysis of a endodontically treated teeth restored with two different types of post and core systems.

Isaac José Peixoto Batinga da Rocha 06 November 2000 (has links)
O estudo comparativo da distribuição de tensões de von Mises em dente endodonticamente tratado, com dois formatos de retentores intra-radiculares, pré-fabricado cilíndrico/escalonado e fundido cônico, foi realizado pelo método dos elementos finitos em modelos tridimensionais de caninos superiores com geometria axi-simétrica e restaurados com coroas metalocerâmicas, aplicando-se uma carga oblíqua de 100N com 45 º de inclinação em relação ao seu longo eixo. Os resultados indicaram uma discreta diferença nos dois modelos (formatos) de retentores. O pino escalonado neutralizou mais as cargas no sentido corono-apical e no pino cônico ficou evidenciado o efeito de cunha. / The aim of this study was to compare the von Mises stress distribution on a human canine teeth endodontically treated and restored with two types of post and core. The analysis was made using the three dimensional Finite Element Analysis method. For the analysis was created and axy-simetric structure of the teeth, including a porcelain fused to metal crown, a cement layer, and the periodontal structures. The model was analyzed when a 100N load was applied on the surface of the crown with 45º angulation with the long axis of the teeth. The results showed that both models exhibit little difference, the “stair shape” post system neutralized the axial loads, and the conical shape post showed a wedge effect on the apical third of the root.
13

Distribuição de tensões em próteses parciais fixas posteriores livres de metal com retentores intracoronários: análise em elementos finitos / Stress distribution on metal-free posterior inlay-retained fixed partial dentures: finite element analysis

Marcelo Gomes da Silva 23 February 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Para reabilitar a ausência de um elemento dentário posterior, as próteses parciais fixas (PPF) com retentores intracoronários são uma alternativa aos implantes osseointegrados. O objetivo deste estudo foi avaliar a distribuição de tensões nessas próteses com três combinações de materiais: cerâmica de zircônia parcialmente estabilizada por ítria (ZPEI) revestida por cerâmica de fluorapatita (α), cerâmica de dissilicato de lítio (β) ou compósito fibrorreforçado (γ). Na composição α, foram analisadas a presença ou ausência da cerâmica de revestimento na parede cervical das caixas proximais e três variações na área total da seção transversal dos conectores (4 mm de largura x 3,2, 4,2 ou 5,2 mm de altura). Em 8 modelos bidimensionais de elementos finitos, uma carga vertical de 500 N foi aplicada na fossa central do pôntico e as tensões principais máximas (tração) e mínimas (compressão) foram apontadas em MPa. Inicialmente foram avaliados os 6 modelos com PPF de ZPEI e suas variações. Os maiores valores das tensões de tração foram encontrados no terço cervical dos conectores. Quando presente nestas regiões, a cerâmica de revestimento recebeu tensões acima do limite de sua resistência à flexão. Na comparação entre os modelos sem cerâmica de revestimento na parede cervical das caixas proximais, mesmo aquele com conectores de 3,2 x 4 mm, cuja infraestrutura apresentava 2,5 x 3 mm, poderia ser recomendado para uso clínico. Altos valores de tensões de compressão foram registrados entre o terço oclusal e médio dos conectores, correspondente à união entre as cerâmicas, o que poderia ocasionar, devido à flexão, falhas adesivas. Posteriormente, o modelo de ZPEI com a cerâmica de fluorapatita ausente da parede cervical das caixas proximais e área total dos conectores de 4,2 x 4 mm foi comparado aos dois outros materiais com conectores de mesma área. Na PPF de dissilicato de lítio, os valores representaram uma provável violação do limite de sua resistência à flexão. A PPF de compósito fibrorreforçado apresentou tensões bem abaixo do limite de resistência à flexão de sua infraestrutura, mas, como no modelo de ZPEI, tensões compressivas se concentraram com alto valor entre o terço oclusal e médio dos conectores, local de união entre a resina composta e a infraestrutura de fibras. Os resultados mostraram que a cerâmica de dissilicato de lítio e a presença da cerâmica de fluorapatita na parede cervical das caixas proximais deveriam ser contraindicadas para a condição proposta. Parece viável uma área de conectores na infraestrutura de ZPEI com no mínimo 2,5 x 3 mm. A PPF de compósito fibrorreforçado apresenta resistência estrutural para a situação estudada, mas, como também aquelas compostas de ZPEI, aparenta ter como pontos fracos a adesão entre a infraestrutura e o material de cobertura e a própria resistência deste último. / Inlay-retained fixed partial dentures (IRFPD) are an alternative to osseointegrated implants to replace a single missing posterior tooth. The aim of this study was to evaluate the stress distribution within these prostheses with three material combinations: yttria-tetragonal zirconia polycrystal (Y-TZP) ceramic veneered with fluorapatite ceramic (α), lithium-disilicate ceramic (β) or fiber-reinforced composite (γ). In composition α, an analysis was conducted on the presence or absence of the veneering ceramic on the cervical wall of the proximal boxes and three variations in the total area of the connectors cross-section (4 mm in width x 3.2, 4.2 or 5.2 mm in height). In 8 two-dimensional finite element models, a vertical load of 500 N was applied on the central fossa of the pontic. Maximum (tension) and minimum (compression) principal stresses were then shown in MPa. First, the 6 models with Y-TZP fixed partial dentures (FPD) and their variations were evaluated. The highest values of tensile stresses were found at the cervical third of the connectors. When present in these regions, the veneering ceramic received stresses beyond its flexural strength limit. In the comparison among models without veneering ceramic on the cervical wall of the proximal boxes, even the model with connectors of 3.2 x 4 mm, whose framework presented 2.5 x 3 mm, could be recommended for clinical use. High values of compressive stresses were recorded between the middle and occlusal thirds of the connectors, corresponding to the juncture of the ceramics. Owing to flexure, these stresses might lead to adhesive failures. Then, the Y-TZP model without fluorapatite ceramic on the cervical wall of the proximal boxes and total connector area of 4.2 x 4 mm was compared to the other two materials with connectors of the same area. For the lithium-disilicate FPD, the observed values would probably exceed its flexural strength limit. The fiber-reinforced composite FPD presented stresses far below the flexural strength limit of its framework, but, as observed in the Y-TZP model, high values of compressive stresses were concentrated between the middle and occlusal thirds of the connectors, where the juncture of the composite and the fiber framework is located. The results showed that the use of lithium-disilicate ceramics and the presence of fluorapatite ceramics on the cervical wall of the proximal boxes should be contraindicated for the condition proposed. A minimum of 2.5 x 3 mm for the connector area of the Y-TZP framework seems viable. The fiber-reinforced composite FPD presented structural resistance for the situation studied but, as was also the case of the Y-TZP fixed partial dentures, its weak points seem to be the adhesion between the framework and the veneering material, as well as the resistance of the veneering material itself.
14

Distribuição de tensões em próteses parciais fixas posteriores livres de metal com retentores intracoronários: análise em elementos finitos / Stress distribution on metal-free posterior inlay-retained fixed partial dentures: finite element analysis

Marcelo Gomes da Silva 23 February 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Para reabilitar a ausência de um elemento dentário posterior, as próteses parciais fixas (PPF) com retentores intracoronários são uma alternativa aos implantes osseointegrados. O objetivo deste estudo foi avaliar a distribuição de tensões nessas próteses com três combinações de materiais: cerâmica de zircônia parcialmente estabilizada por ítria (ZPEI) revestida por cerâmica de fluorapatita (α), cerâmica de dissilicato de lítio (β) ou compósito fibrorreforçado (γ). Na composição α, foram analisadas a presença ou ausência da cerâmica de revestimento na parede cervical das caixas proximais e três variações na área total da seção transversal dos conectores (4 mm de largura x 3,2, 4,2 ou 5,2 mm de altura). Em 8 modelos bidimensionais de elementos finitos, uma carga vertical de 500 N foi aplicada na fossa central do pôntico e as tensões principais máximas (tração) e mínimas (compressão) foram apontadas em MPa. Inicialmente foram avaliados os 6 modelos com PPF de ZPEI e suas variações. Os maiores valores das tensões de tração foram encontrados no terço cervical dos conectores. Quando presente nestas regiões, a cerâmica de revestimento recebeu tensões acima do limite de sua resistência à flexão. Na comparação entre os modelos sem cerâmica de revestimento na parede cervical das caixas proximais, mesmo aquele com conectores de 3,2 x 4 mm, cuja infraestrutura apresentava 2,5 x 3 mm, poderia ser recomendado para uso clínico. Altos valores de tensões de compressão foram registrados entre o terço oclusal e médio dos conectores, correspondente à união entre as cerâmicas, o que poderia ocasionar, devido à flexão, falhas adesivas. Posteriormente, o modelo de ZPEI com a cerâmica de fluorapatita ausente da parede cervical das caixas proximais e área total dos conectores de 4,2 x 4 mm foi comparado aos dois outros materiais com conectores de mesma área. Na PPF de dissilicato de lítio, os valores representaram uma provável violação do limite de sua resistência à flexão. A PPF de compósito fibrorreforçado apresentou tensões bem abaixo do limite de resistência à flexão de sua infraestrutura, mas, como no modelo de ZPEI, tensões compressivas se concentraram com alto valor entre o terço oclusal e médio dos conectores, local de união entre a resina composta e a infraestrutura de fibras. Os resultados mostraram que a cerâmica de dissilicato de lítio e a presença da cerâmica de fluorapatita na parede cervical das caixas proximais deveriam ser contraindicadas para a condição proposta. Parece viável uma área de conectores na infraestrutura de ZPEI com no mínimo 2,5 x 3 mm. A PPF de compósito fibrorreforçado apresenta resistência estrutural para a situação estudada, mas, como também aquelas compostas de ZPEI, aparenta ter como pontos fracos a adesão entre a infraestrutura e o material de cobertura e a própria resistência deste último. / Inlay-retained fixed partial dentures (IRFPD) are an alternative to osseointegrated implants to replace a single missing posterior tooth. The aim of this study was to evaluate the stress distribution within these prostheses with three material combinations: yttria-tetragonal zirconia polycrystal (Y-TZP) ceramic veneered with fluorapatite ceramic (α), lithium-disilicate ceramic (β) or fiber-reinforced composite (γ). In composition α, an analysis was conducted on the presence or absence of the veneering ceramic on the cervical wall of the proximal boxes and three variations in the total area of the connectors cross-section (4 mm in width x 3.2, 4.2 or 5.2 mm in height). In 8 two-dimensional finite element models, a vertical load of 500 N was applied on the central fossa of the pontic. Maximum (tension) and minimum (compression) principal stresses were then shown in MPa. First, the 6 models with Y-TZP fixed partial dentures (FPD) and their variations were evaluated. The highest values of tensile stresses were found at the cervical third of the connectors. When present in these regions, the veneering ceramic received stresses beyond its flexural strength limit. In the comparison among models without veneering ceramic on the cervical wall of the proximal boxes, even the model with connectors of 3.2 x 4 mm, whose framework presented 2.5 x 3 mm, could be recommended for clinical use. High values of compressive stresses were recorded between the middle and occlusal thirds of the connectors, corresponding to the juncture of the ceramics. Owing to flexure, these stresses might lead to adhesive failures. Then, the Y-TZP model without fluorapatite ceramic on the cervical wall of the proximal boxes and total connector area of 4.2 x 4 mm was compared to the other two materials with connectors of the same area. For the lithium-disilicate FPD, the observed values would probably exceed its flexural strength limit. The fiber-reinforced composite FPD presented stresses far below the flexural strength limit of its framework, but, as observed in the Y-TZP model, high values of compressive stresses were concentrated between the middle and occlusal thirds of the connectors, where the juncture of the composite and the fiber framework is located. The results showed that the use of lithium-disilicate ceramics and the presence of fluorapatite ceramics on the cervical wall of the proximal boxes should be contraindicated for the condition proposed. A minimum of 2.5 x 3 mm for the connector area of the Y-TZP framework seems viable. The fiber-reinforced composite FPD presented structural resistance for the situation studied but, as was also the case of the Y-TZP fixed partial dentures, its weak points seem to be the adhesion between the framework and the veneering material, as well as the resistance of the veneering material itself.

Page generated in 0.0664 seconds