• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 304
  • 10
  • 6
  • 6
  • 6
  • 5
  • 4
  • 3
  • 3
  • 2
  • Tagged with
  • 323
  • 178
  • 161
  • 105
  • 89
  • 58
  • 58
  • 53
  • 49
  • 41
  • 31
  • 28
  • 28
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação do desempenho de gotejadores com uso de água residual na suinocultura /

Franco, Daniel, 1982. January 2015 (has links)
Orientador: Helio Grassi Filho / Banca: Antonio de Padua Sousa / Banca: Thomaz Figueiredo Lobo / Resumo: O objetivo do presente trabalho foi de avaliar a uniformidade de aplicação de água utilizando o coeficiente de uniformidade de distribuição (CUD), coeficiente de uniformidade de Christiansen (CUC) e o coeficiente de uniformidade estatístico (CUE), além de determinar o coeficiente de variação de vazão (CVQ) utilizando o tubo gotejador da marca Netafim modelo Streamline 16060, após seu uso com água residuária oriunda da suinocultura. O experimento foi conduzido no Laboratório de Irrigação da UNESP-FCA, Campus de Botucatu-SP. Foi executado em uma bancada de ensaio de gotejadores, utilizando quatro segmentos do tubo gotejador com 6 metros, e escolhidos 32 emissores, onde se verificou a vazão destes emissores com as seguintes pressões: 45, 55, 65, 78 kPa, com quatro repetições para cada gotejador. Após os ensaios, o tubo gotejador foi submetido a 600 horas de trabalho com água residuária oriunda da suinocultura. Foram realizados os mesmos ensaios com o tubo gotejador novo com, 100, 200, 300, 400 e 500 horas de trabalho com água residuária. Os valores obtidos com o tubo novo e após seu uso durante 400 horas com água residuária da suinocultura para o CVQ foram classificados como bons, pela tabela da ABNT (1987). Já quando se atingiu 500 horas de trabalho as pressões 45 e 65 kPa apresentaram um CVQ de 0,5 considerado médio pela ABNT (1987) e com 600 horas de trabalho as avaliações em todas pressões foram classificadas como médio. O CUD, CUC, e o CUE, desde o ensaio inicial e até 600 horas de trabalho na bancada, foram considerados como excelentes, de acordo com Merriam & Keller (1978), apesar de alguns gotejadores ao longo do tempo apresentarem obstruções parciais. Porem com o passar do tempo o CUD e o CUE apesar de serem classificados como excelentes apresentaram um leve declínio em seus valores. Com base nos resultados obtidos, foi possível concluir que, após 600 horas... / Abstract: The aim of the present work was to evaluate the application uniformity of water using the distribution uniformity coefficient (DU), Christiansen uniformity coefficient (UC) and statistical uniformity coefficient (SUC), besides determine the flow variation coefficient (FVC) using a Netafim brand 16060 Streamline model dripper tube, after its use with swine wastewater. The The experiment was done in Irrigation Laboratory of UNESP-FCA, Botucatu-SP campus. It have done in a dripper test bench using four sections of 6 meters dripper tubes, 32 emitters chosen, where the flow verified in the emitters was the following pressure: 45, 55, 65, 78kPa, with four repetitions for each dripper. After the test, the dripper tube was subordinated to 600 hours work with swine wastewater. It have done the same tests with the new dripper tube with 100, 200, 300, 400 and 500 hours of work with residual water. The obtained values with the new tube and after its use through 400 hours with swine wastewater for FVC were classified as good by ABNT chart (1987). Nevertheless, when reached 500 hours of work, the pressures 45 and 65 kPa show a FVC of 0.5 considerate medium by ABNT (1987) and with 600 hours of work, the evaluation in all pressures were classified as medium. The DU, UC and SUC, since initial test to 600 hours of work in bench were classified as excellent, according to Merriam & Keller (1978), despite of some drippers show partial obstruction through time. However, through the time, the DU and UC besides classified as excellent show a small decline in their values. Based in the obtained results, it is possible to conclude that after 600 dripper tube hours of use, the dripper keep satisfactory water application uniformity, the test showed the possibility of swine wastewater for dripper irrigation, without dripper obstruction problems in periods until 600 hours of use. For swine wastewater use in irrigation projects ... / Mestre
92

Estimativa da correção do coeficiente de retorno de esgoto sanitário em habitações com sistemas de aproveitamento de água pluvial : estudo de caso da cidade de Bauru (SP) /

Leão, Cintia Loturco Pinheiro. January 2015 (has links)
Orientador: Rodrigo Braga Moruzzi / Banca: Fabiano Tomazini da Conceição / Banca: Marcelo de Julio / Resumo: Vário estudos têm sido realizados propondo técnicas de conservação de água, visando minimizar o consumo de água tratada. Dentre eles destaca-se o aproveitamento de água pluvial em atividades que possam prescindir da potabilidade. No Brasil, a cobrança dos serviços de coleta e tratamento de esgoto sanitário, em geral, é realizada com base no volume de água tratada medida do hidrômetro da unidade consumidora. Portanto, esse descarte de esgoto gerado pelo sistema de aproveitamento de água pluvial não é contabilizado pelo sistema de tarifação de esgoto no custo de destinação e tratamento. A utilização dessa água pluvial subestima o volume de esgoto gerado. Este trabalho propõe a aplicação da metodologia para o ajuste desse coeficiente de retorno visando estimar o volume de água pluvial lançado na rede coletora de esgoto indexado ao volume de água tratada medido no hidrômetro de cada unidade consumidora. A bacia sanitária com caixa acoplada foi adotada como objeto de estudo. A partir da coleta de amostragens de áreas de telhado do município de Bauru (SP), determinou-se a área média de telhado. Diferentes simulações de determinação de áreas de telhado, volumes de reservatórios e demandas de consumo de água foram realizadas, com o intuito de analisar o comportamento do ajuste do coeficiente de retorno para a área média de telhado per capita (m2.hab-1). Os resultados apontaram que o município de Bauru (SP) apresent uma área de telhado da ordem de 139,91 = 3,12m2 para residências, de 5,58 m2.hab-1 para apartamentos e uma área média ponderada de 132,18 m2 por domicílio. Apresentando uma área média per capita de 49,21 m2. Verificou-se que em todas as faixas de consumo per capita, para o volume de reservatório de 0,5 m3.hab-1, o lançamento de água pluvial na rede coletora de esgoto apresentou eficiência com valores menores que 30% para as áreas específicas de cobertura de 4 a 17 m2.hab-1, portanto... / Abstract: Several studies have been conducted proposing water conservation techniques to minimize the treated water consumption. Among them stands out the rainwater utilization in activities that may dispense the potability. In Brazil, the pricing on the collection and treatment services of sewage, is generally performed based on the volume of treated water measured at the meter of the consumer unit. Therefore, this sewage disposal generated by rainwater utilization system is not accounted for sewage charging system on the cost of disposal and treatment. The use of this rainwater underestimates the volume of sewage generated. This paper proposes the application of the methodology for setting this return coefficient to estimate the volume of rainwater released in the sewage disposal system linked to the volume of treated water measured at the meter of each consumer unit. The sanitary bowl with box attached was adopted as an object of study. From the collection of roof areas sampling the city of Bauru (SP) determined the average area of the roof. Different simulations of determining roof areas, reservoir volumes and water consumption demands were made, in order to analyze the return coefficient setting behavior for the average area of roof per capita (m2.hab-1). The results showed that the city of Bauru (SP) features a roof area of approximately 139.91 = 3.12 m2 for homes, 5.58 m2.hab-1 for apartments and wa weighted average area of 132.18 m2 per household. With an average are per capita of 49,21 m2. It was found that in all per capita consumpetion ranges, for volume of 0.5 m3 reservoir/in habitant, the release of rainwater in the sewage disposal system was efficient with values less than 30% specific coverage areas 4-17 m2.hab-1 therefore concluded that discharges into sanitary bowl were not met fully by rainwater utilization system. In this way it was stated that not all use of water for unloading in sanitary bowl is transferred to the collection... / Mestre
93

Eficiência de um sistema de desinfecção solar de águas residuárias domésticas com adição de diferentes doses de peróxido de hidrogênio /

Alves, Thaís Regina, 1987. January 2015 (has links)
Orientador: Rodrigo Máximo Sánchez Román / Banca: Claudinei Fonseca Souza / Banca: Hélio Grassi Filho / Resumo: O presente trabalho teve como objetivo avaliar a eficiência de um sistema de desinfecção solar com adição de diferentes doses de peróxido de hidrogênio (H2O2) na desinfecção de águas residuárias domésticas para fins de reúso na agricultura irrigada, usando como parâmetro de qualidade as recomendações da Organização Mundial da Saúde (WHO). Além disso, foi analisada a ocorrência de reativação bacteriana 24 e 48 horas após o fim do processo de desinfecção solar. Foram testadas cinco doses de H2O2 (25, 50, 75, 100 e 125 mg L-1) além do grupo controle (0 mg L-1), com seis repetições de cada, em duas lâminas de efluente (10 e 20 cm). Em quatro repetições, as coletas foram feitas em intervalos de cinco horas (8:00, 13:00 e 18:00 h). Nas duas repetições restantes, as coletas foram feitas em intervalos de duas horas (8:00, 10:00, 12:00, 14:00, 16:00 e 18:00 h). Foi desenvolvido um modelo matemático para cada dose avaliada e um modelo geral para todas as doses de H2O2. Os resultados mostram um aumento considerável da eficiência da desinfecção solar com adição de doses de H2O2 maiores de 25 mg L-1, com consequente redução no período de exposição necessário para a obtenção de efluente com qualidade para reúso irrestrito na agricultura irrigada. Na maior dose avaliada e nos meses mais quentes do ano, o período de desinfecção chega a ser inferior a um dia, dependendo das demais condições ambientais e do afluente. No grupo controle, esse período chega a ser maior do que três dias. A reativação bacteriana ocorreu em todos os grupos avaliados, exceto para ... / Abstract: The aim of this study was to evaluate the efficiency of a solar disinfection system with addition of different doses of hydrogen peroxide to disinfect domestic wastewater for reuse purposes in irrigated agriculture, using as quality parameter the World Health Organization (WHO) recommendations. Furthermore, the occurrence of bacterial reactivation was analyzed 24 and 48 hours after the disinfection process. Five doses of hydrogen peroxide (25, 50, 75, 100 and 125 mg L-1) were tested plus the control group (0 mg L-1), with six replicates of each in two effluent depths (10 and 20 cm). In four replicates, the samples were taken at intervals of five hours (8:00, 13:00 and 18:00 h). The remaining two replicates, samples were taken at intervals of two hours (8:00, 10:00, 12:00, 14:00, 16:00 and 18:00 h). A mathematical model for each dose evaluated and a general model for all doses were developed. The results showed a considerable increase in the efficiency of solar disinfection with the addition of hydrogen peroxide greater than 25 mg L-1, with consequent reduction in the exposure time required to obtaining effluent with quality for unrestricted use in irrigated agriculture. For the highest dose evaluated and in the warmer months of the year, the disinfection period remained below one day, depending on environmental conditions and the affluent's characteristic. In the control group, the period was longer than three days. Bacterial reactivation occurred in all groups except for the 125 mg L-1 dose and 10 cm wastewater depth. It may be concluded than, that the use of controlled doses of hydrogen peroxide is capable of considerably increase the efficiency of the disinfection process, especially in the higher dose evaluated. In addition, the effluent of such treatment can be allocated to irrigated agriculture for products that can be eaten uncooked, according to WHO (2006). / Mestre
94

Agua de reuso e seu efeito sobre parâmetros fisiológicos em manjericão (Ocimum basilicum L.) /

Bressan, Dayanne Fabrício, 1980. January 2015 (has links)
Orientador: Fernando Broetto / Banca: Roberto Lyra Villas Bôas / Banca: Rodrigo Máximo Sanches Roman / Banca: Marcelo Leonardo / Banca: Marcia Ortiz Mayo Marques / Resumo: A água destinada para irrigação torna-se cada vez mais limitada, sendo necessário a busca de fontes alternativas de água para a situação de escassez na agricultura. Uma das alternativas eficazes é o reaproveitamento da água de reuso tratada, principalmente em regiões onde a escassez e a má distribuição de água tornam-se fatores limitantes ao seu uso. No setor agrícola mundial, o aproveitamento da água de reuso na irrigação das plantas, tem demonstrado importância econômica, agronômica e ambiental. A água de reuso é conhecida como de baixa qualidade, devido as altas concentrações salinas, entretanto, a maioria dessas águas é rica em elementos minerais que são essenciais para o desenvolvimento do vegetal e outros potencialmente fitotóxicos. Quando utilizada para fins agrícolas pode trazer benefícios econômicos, todavia, o efeito que estes elementos presentes na água podem causar no desenvolvimento das plantas vai depender do tratamento da água, da sua origem e da tolerância da espécie a ser estudada. Diante disso, o presente estudo verificou os efeitos nutricionais, osmóticos e ou salinos, derivados da água de reuso, sobre a resposta bioquímica e fisiológica na planta de Ocimum basilicum L. Para o plantio, foram utilizadas sementes da cv. Genovese conhecida como manjericão da folha larga que apresenta grande interesse comercial e medicinal na produção do óleo essencial. Os tratamentos aplicados foram: T1- Água deionizada; T2- Água deionizada com NaCl (15 mM); T3- Água de reuso tratada captada da ETE - SABESP e Ozonizada e T4- Água deionizada com NaCl (30 mM) via gotejamento em diferentes épocas de amostragem. Os parâmetros de relações hídricas, biometria, trocas gasosas e IRC não foram afetados pela irrigação com água de reuso, diferentemente dos tratamentos salinos que reduziram o potencial hídrico, MSF e MST. A análises bioquímicas indicaram ... / Abstract: The water used for irrigation becomes increasingly restricted, making it necessary to try alternative sources of water in case of shortage in agriculture. One effective alternative is the reuse of treated wastewater, especially in regions where the shortage and misdistribution of water make limiting factors to its use. In the global agricultural sector, the use of wastewater for irrigation of plants has been important economically, agronomically and environmentally. The reuse of water is known as low quality, due to high and potentially phytotoxic elements, and concentrations of salt, however, most of this water is rich in mineral elements, which are essential for the development of the vegetable. When used for agricultural purposes, it can bring economic benefits, nevertheless, the effect that these elements can cause in the growth of plants will depend on the water treatment, its origin and the tolerance of species to be studied. Thus, the nutritional, osmotic or saline effects, derived from wastewater on the biochemical and physiological response in Ocimum basilicum L. were analyzed in this current study. For planting, cv. Genovese seeds were used. This cultivar is known as broad leaf basil, which has great commercial and medicinal interests for its essential oil production. The applied treatments were: T1 deionized water; T2 deionized water with NaCl (15 mM); T3 wastewater drawn from the ETE - SABESP, afterwards ozonized, and T4 deionized water with NaCl (30 mM), the treatments were applied via dripping at different sampling times. The parameters of water relations, biometric, gas exchange and IRC relations were not affected by irrigation with wastewater, unlike the saline treatments that reduced water potential, MSF and MST. The biochemical analysis indicated that only the saline treatments activated enzymes related to antioxidant response system. Plants irrigated with wastewater and ... / Doutor
95

Eficiência de alagados construídos para o tratamento de águas residuárias com baixas cargas orgânicas /

Queluz, João Gabriel Thomaz, 1985- January 2016 (has links)
Orientador: Rodrigo Máximo Sánchez-Román / Coorientador: Macelo Loureiro Garcia / Banca: Eduardo Luiz de Oliveira / Banca: Marcos Vinicius Folegatti / Banca: Hélio Grassi Filho / Banca: Tarlei Arriel Botrel / Resumo: A maioria dos sistemas de tratamento de águas residuárias é complexa, têm construção e manutenção dispendiosas e necessitam de recursos humanos qualificados para operação, características que praticamente inviabilizam sua adoção na zona rural do país. Áreas rurais demandam sistemas de custo reduzido, simples e de fácil operacionalidade, características encontradas em sistemas de alagados construídos.Os objetivos do presente trabalho foram: desenvolver um sistema alagado construído para o tratamento de águas residuárias; avaliar a eficiência do alagado construído utilizando diferentes densidades de macrófitas; verificar a resposta do sistema a diferentes taxas de aplicação de matéria orgânica; e ajustar e modificar modelos hidráulicos que representem a cinética de remoção de matéria orgânica e de coliformes fecais.Foi desenvolvido um sistema de tratamento com três leitos de alagados construídos, compostos por quatro caixas d'água retangulares ligadas em série. As caixas d'água foram preenchidas com o material suporte (brita #0) até a altura de 30 cm e ficaram saturadas com efluente até a altura de 25 cm. Os alagados construídos foram cultivados com diferentes densidades (0, 11,5 e 23 plantas m-2) de taboa (Typha latifólia). Cada leito recebeu 50 litros diários de água residuária doméstica, resultando em 3,2 dias de tempo de detenção hidráulica nominal. A eficiência do sistema foi avaliada pela análise de coliformes fecais, coliformes totais, condutividade elétrica, demanda... / Abstract: Most wastewater treatment systems are complex, have expensive cost for both construction and maintenance, and require skilled manpower for operation, features that practically precludes its adoption in rural areas of the country. Rural areas require simple and low-cost systems, characteristics found in constructed wetlands. This study aimed 1) to develop a constructed wetland system for wastewater treatment; 2) to assess the constructed wetlands efficiency using different densities of macrophytes; 3) to check the system response to different organic matter application rates; 4) to adjust and modify hydraulic models which represent the kinetics of organic matter and fecal coliforms removal. It was developed a treatment system with three constructed wetlands beds, composed by four rectangular water storage tanks connected in series. The water tanks were filled with gravel (Ø = 2.4 - 9.5 mm) to a height of 30 cm and were saturated with effluent to a height of 25 cm. The constructed wetlands were cultivated with different cattail (Typha latifolia) densities: 0, 11.5 and 23 plants m-2. Each bed received 50 liters of domestic wastewater per day, resulting in 3.2 days of nominal hydraulic retention time. The system efficiency was evaluated by the analysis of fecal coliforms, total coliforms, electrical conductivity, biochemical oxygen demand, chemical oxygen demand, total phosphorus, total nitrogen, pH, potassium, redox potential, total suspended solids, temperature, and turbidity. Linear regression analysis was performed to compare the efficiency of the three constructed wetlands in the removal of organic matter and pathogens. Furthermore, chemical oxygen demand and fecal coliforms data were compared with conventional hydraulic models using the coefficient of determination. The constructed wetlands were efficient for removing fecal coliforms (99%), biochemical oxygen demand (72%), chemical oxygen demand ... / Doutor
96

Análise da viabilidade de implantação de um sistema de captação de água de chuva para lavagem de aeronaves e reuso de efluentes /

Silva, Janaina Andréa. January 2018 (has links)
Orientador: Teófilo Miguel de Souza / Banca: Osiris Canciglieri Júnior / Banca: Eliana Vieira Canettieri / Resumo: O objetivo deste trabalho foi analisar a viabilidade de implantação de um sistema de captação de água de chuva para abastecer o processo de lavagem de aeronaves na EMBRAER, e este estudo pode ser estendido para aplicação aos centros de manutenção de companhias aéreas nacionais e aeroportos. O trabalho consiste em um estudo de caso. Em sua realização foram analisadas as condições locais para implantar o sistema de coleta de água de chuva, a quantidade de recurso pluvial disponível na região de São José dos Campos, a necessidade de armazenagem de água para suprir períodos de estiagem, a qualidade necessária da água para atender a esta finalidade, e as aplicações para o reuso do efluente da lavagem de aeronaves. Os resultados mostraram que o volume de água de chuva disponível na região é suficiente para abastecer o processo de lavagem das aeronaves e que a água tem qualidade suficiente para esta aplicação. O trabalho mostra ainda que com a reutilização do efluente gerado na lavagem de aeronaves torna a implantação do projeto viável e que além do retorno financeiro, a proposta traz benefício ambiental, preservando o recurso hídrico de boa qualidade / Abstract: The aim of this work was to verify the feasibility of introduce a rainwater harvesting system to supply the aircraft washing process at EMBRAER and this study may be extended to the airlines maintenance centers and airports. This work consists in a case study. To perform this work were studied the local conditions to introduce the rainwater harvesting system, the amount of rainfall available in São José dos Campos, the need to storage water to supply drought periods, the quality of the water to supply the process with security and the applications for reuse the effluent from aircraft washing process. The results showed that the amount of rainwater avaiable in the region is enough to supply the aircrafts washing process and the water is sufficient in quality for this application. The work also showed that the reuse of the effluent generated by the aircraft washing process makes feasible the project implementation. In addition to the financial return, the purpose brings environmental benefits preserving the good quality water resources / Mestre
97

Irrigação de hortaliças utilizando efluente secundário desinfectado por radiação solar /

Sales, Mariana Alexandre de Lima, 1988- January 2018 (has links)
Orientador: Rodrigo Máximo Sánchez-Román / Banca: João Carlos Cury Saad / Banca: Hélio Grassi Filho / Banca: Gabriel Thomaz Queluz / Banca: Waleska Martins Eloi / Resumo: Associar o tratamento de água residuária doméstica (ARD) ao o uso pela agricultura familiar pode ser uma alternativa viável para a sustentabilidade ambiental no meio agrícola. No entanto, ainda são necessários diversos estudos sobre a reutilização desta água. O experimento foi realizado no Departamento de Engenharia Rural, Faculdade de Ciências Agronômicas (FCA) - Universidade Estadual Paulista (UNESP), Fazenda Experimental Lageado, no município de Botucatu, São Paulo, o qual consistiu em verificar diferentes porcentagens (0, 25, 50, 75 e 100%) de água residuária doméstica tratada, na lâmina total de irrigação e qual a relação desta com a produção, considerando a qualidade microbiológica dos produtos. Os objetivos deste trabalho foram avaliar a influência dos tratamentos estudados no entupimento da fita gotejadora, no solo e nas culturas da cebolinha 'todo ano', salsa 'graúda portuguesa' e abobrinha 'italiana' tanto na produção agrícola, quanto na presença de E. coli. O delineamento estatístico adotado foi em DIC (delineamento inteiramente casualizado), cada tratamento consistiu de cinco linhas laterais de irrigação, com espaçamento de 0,8 m entre linhas e de 0,3 m entre gotejadores, onde havia um emissor por planta para as culturas de cebolinha 'todo ano' e salsa 'graúda portuguesa', porém para a cultura da abobrinha 'italiana' o espaçamento foi de 1,2 m entre plantas. Os resultados obtidos na pesquisa foram: no solo observou-se algumas mudanças nas características químicas,... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Linking domestic wastewater treatment (RDA) to the use of family farming can be a viable alternative to environmental sustainability in agriculture. However, several studies are still needed on the reuse of this water. The experiment was carried out the Department of Rural Engineering, São Paulo State University (UNESP), School of Agriculture, Experimental Farm Lageado, in the city of Botucatu, São Paulo, and consisted in verifying different percentages (0, 25, 50, 75 and 100%) of treated domestic wastewater, in the total irrigation depth, and the relation between this and the production, considering the microbiological quality of the products. The objectives of this work were to evaluate the influence of the treatments studied on the drip tape clogging in the soil and on the 'all year' chives, 'Portuguese' parsley and 'Italian' zucchini, both in agricultural production and in the presence of E. coli. The statistical design adopted was CRD (completely randomized design), each treatment consisted of five lateral irrigation lines, spaced 0.8 m between rows and 0.3 m between drippers, with one emitter per plant for the crops of chives 'all year' and 'graúda portuguese' parsley, but for the 'Italian' zucchini culture the spacing was 1.2 m between plants. The results obtained in the research were: in the soil some changes in the chemical characteristics were observed, noting both increase and decrease in the levels of certain nutrients. The irrigation system presented a reduction in the coefficients of uniformity, however they were still close to 90%. In relation to the studied crops, there was a linear increase in the values observed in relation to domestic wastewater treated by solar radiation - ARD-TRS in the parameters of mean plant height, mean stalk number, mean stalk diameter, mean diameter of the clump and mass of the fresh and dry matter, for chives 'all year' and 'graúda portuguese'... / Doutor
98

Irrigação com esgoto doméstico tratado em área cultivada com laranja /

Silva, Andreia Aparecida Ferreira da, 1976. January 2018 (has links)
Orientador: Hélio Grassi Filho / Coorientador: Antonio Evaldo Klar / Coorientador: Reginaldo Ferreira Santos / Banca: Maria Helena Moraes Spinelli / Banca: Camila Pires Cremasco Gabriel / Banca: Aline Azevedo Nazario / Banca: Alysson Jalles da Silva / Resumo: Dentre as alternativas propostas para conter a crise hídrica, está à utilização de esgoto doméstico tratado (EDT) na agricultura, sendo esta uma proposta eficiente na preservação dos recursos naturais disponíveis tanto qualitativa quanto quantitativamente. O presente trabalho objetivou avaliar os parâmetros químicos do solo cultivado com laranjeiras e irrigado com esgoto doméstico tratado via gotejamento superficial e subsuperficial. As avaliações foram conduzidas na Fazenda Lagoa Bonita/UNASP em Engenheiro Coelho, SP. O delineamento experimental utilizado foi em faixas de cultivo no esquema de parcelas subdivididas, o experimento constituído por 5 tratamentos com 5 repetições, totalizando 25 unidades experimentais. Nas parcelas foram avaliadas as duas qualidades de água (esgoto doméstico tratado - EDT, e água de reservatório - AR) e nas subparcelas o sistema de gotejamento superficial, o sistema de gotejamento subsuperficial; e a testemunha sem irrigação. Foram realizadas análises de solo, água de reservatório e EDT e também dos frutos para verificação das características químicas e de produtividade. O tratamento irrigação subsuperficial com aplicação de água foi o que apresentou as maiores médias para o pH, Ca na profundidade de 0,20 m, Mg nas profundidades de 0,20 e 0,40m também MO. O tratamento irrigação subsuperficial com aplicação de efluente apresentou as menores médias para o pH, Ca e Mg nas profundiades de 0,20 e 0,60m. O tratamento sem irrigação apresentou as maiore... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Among the alternatives proposed to contain the water crisis, is the use of treated domestic sewage (EDT) in agriculture, which is an efficient proposal to preserve the natural resources available both qualitatively and quantitatively. The present work aimed to evaluate the chemical parameters of soil cultivated with orange trees and irrigated with domestic sewage treated via surface and subsurface drip irrigation. The evaluations were conducted at Fazenda Lagoa Bonita / UNASP in Engenheiro Coelho, SP. The experiment was carried out in 5 subplots, with 5 replicates, totaling 25 experimental units. In the plots were evaluated the two qualities of water (domestic sewage treated - EDT, and reservoir water - AR) and in the subplots the surface drip system, the subsurface drip system; and the control without irrigation. Soil, reservoir and EDT analyzes were carried out, as well as the fruits to verify chemical and productivity characteristics. The subsurface irrigation treatment with water application was the one that presented the highest averages for the pH, Ca in the depth of 0.20 m, Mg in the depths of 0.20 and 0,40 m also MO. The subsurface irrigation treatment with effluent application showed the lowest averages for pH, Ca and Mg at the depths of 0.20 and 0.60 m. The treatment without irrigation presented the highest averages for NO₃⁻, S, Zn and B and the subsurface treatment showed the highest averages for NH₄⁺ and Mn. It should be considered that during the crop cycle there was a large volume of precipitation that may have directly interfered with the movement of nutrients in the soil and consequently affected the productivity of the plant. The application of effluent when compared to water presented the highest averages for the variables NH₄⁺, Cu, Zn, Fe and Mn. The present work presented promising results regarding the irrigation of the orange crop with EDT via surface ... / Doutor
99

Ozonizaçãoe peroxização de efluente sanitário proveniente de alagados construídos e reator compartimentado anaeróbio/aeróbio visando reuso /

Miranda, Nathalie Dyane. January 2014 (has links)
Orientador: Gustavo Henrique Ribeiro da Silva / Banca: Jorge Hamada / Banca: Luiz Antônio Daniel / Resumo: Esta pesquisa teve por objetivo principal estudar a desinfecção de esgoto sanitário proveniente do tratamento de uma nova configuração de um reator compartilhamentado aneróbio/aeróbio e de alagados construídos, utilizando o ozônio e peroxônio. Avaliaram-se como estes atuam no processo de oxidação e inativação de coliformes totais e Escherichia coli, comparando suas eficiências e a formação do formaldeído, que é principal aldeído formado durante a aplicação de ozônio e peroxônio para desinfecção. A formação de formaldeído foi fortemente da dose de ozônio, porém um tempo de contato maior também favoreceu uma maior formação de formaldeído, mesmo que não significativa segundo os testes estatísticos aplicados. Os ensaios de peroxização com uma dose de 5 mg O3 L-1 promoveram uma média de formação de formaldeído maior que quando apenas aplicando somente a mesma dose de ozônio. Com uma dose de 8 e 10 mg O3 L-1, a formação de formaldeído foi em geral menor que quando aplicada durante somente a mesma dose de ozônio. Ou seja, doses maiores de ozônio durante a peroxização favoreceram uma menor concentração de formaldeído no efluente final. Todos os ensaios de ozonização e peroxização promoveram concentrações de formaldeído que estavam dentro do limite imposto pela OMS (água potável). Tanto para o efluente proveniente dos A.C. quanto do reator compartimentado, doses maiores de ozônio ou um tempo de contato maior não favoreceu uma inativação significativamente maior. A inativação de E. coli, no efluente proveniente do reator compartilhamentado, não foi superior ao se adicionar peróxido de hidrogênio. Já a inativação de coliformes totais foi na maioria dos testes superior aos resultados encontrado quando aplicado somente ozônio, sendo que o consumo de ozônio durante a peroxização foi menor que na ozonização. Pode assim concluir que a adição de peróxido de hidrogênio foi à... / Abstract: This research was aimed to study the disinfection of wastewater from treatment by a new configuration of an anaerobic/aerobic baffled reactor and by constructed wetlands, using ozone and peroxone. Were avaluated how these processes acted in the oxidation and inactivation of total coliforms and Eschechia coli, comparing their efficiency and formation of formaldehyde, which is the main aldehyde formed during the application of ozone and peroxone for disinfection. The formation of frmaldehyde was strongly depend on the dose of ozone, by a longer contact time also favored an increased in the formation of formaldehyde, even not significant according to the statistical tests applied. Peroxidation tests with a dose of 5 mg O3L-1 promoted a higher average formation of formaldehyde than when applying only just the same dose of ozone. For doses of 8 and 10 mg O3L-1, the formation of formaldehyde was generally smaller than when applied just the same dose of ozone. I.e., higher ozone doses during peroxidation favored a lower formaldehyde concentration in the final effluent. All tests ozonation and peroxidation promoted formaldehyde concentrations that were within the limit imposed by WHO (drinking water). For both the effluent from the C.W. as the anaerobic/aerobic baffled reactor, higher ozone doses or a longer contact time did not favor a significantly higher inactivation. Inactivation of Escherichia coli in effluent from the anaerobic/aerobic baffled reactor was no better when added hydrogen peroxide. The inactivation of total coliforms was higher in most of the tests when applied just ozone, and the consumption of ozone during peroxidation was lower than in ozonation tests. This way, is possible to conclude that the addition of hydrogen peroxide was favorable to the inactivation of total coliforms. For the effluent from the anerobic/aerobic baffled reactor only with the application of ozone was required a dose of 8 mg O3 L-1 for the effluent... / Mestre
100

Metodologia para desenvolvimento de software reconfigurável apoiada por ferramentas de implementação: uma aplicação em ambiente de execução distribuído e reconfigurável / Methodology to reconfigurable software development supported by implementation tools: an application in distributed and reconfigurable execution environment

Frank José Affonso 26 May 2009 (has links)
O desenvolvimento de software reconfigurável é uma abordagem que requer padrões nas atividades e nos artefatos produzidos ao longo da elaboração de um projeto de software. Além disso, também prevê uma conduta sistemática do pessoal envolvido, para que as diretrizes de uma metodologia sejam executadas e os benefícios por ela previstos sejam alcançados. Neste trabalho, uma metodologia para o desenvolvimento de software reconfigurável foi elaborada para apoiar essa abordagem de desenvolvimento. Como forma de auxiliar as atividades existentes nesta metodologia e padronizar as atividades por ela previstas, minimizando a participação de seres humanos (desenvolvedores), foi confeccionada uma ferramenta composta por um conjunto de subsistemas capazes de gerar, de maneira automática, informações necessárias, para que a padronização dos procedimentos possa ser realizada e, consequentemente, que a reconfiguração e reutilização dos artefatos ocorram de maneira natural. Essa ferramenta atua em um ambiente distribuído e organizado pelos domínios de atuação e a reutilização/reconfiguração pode ocorrer em artefatos confeccionados para atuar em domínio específico, mas que podem ser adaptados/reutilizados em outros. / The reconfigurable software development is an approach that requires patterns in the activities and in the artifacts produced during the development of a software project. It also requires a systematic conduct of the staff involved in the methodology guidelines, so that the benefits provided can be achieved. In this work, a methodology for the reconfigurable software development was proposed to support this approach. As a way to assist the activities in this methodology and standardize the required activities, minimizing the involvement of humans (developers), a tool was proposed that consists in a set of subsystems capable of generating, in an automatic manner, information needed so that the standardization of information can be performed, therefore, that the reconfiguration and reuse of artifacts could be occur in a natural way. This tool operates in a distributed environment organized by areas of expertise, and reuse/reconfiguration can occur in artifacts constructed to operate in specific domains, but it can be adapted/reused in others.

Page generated in 0.0269 seconds