21 |
Physiology of SittingAndrew Claus Unknown Date (has links)
Background: Clinical ergonomic advice for sitting posture has been inferred from anthropometry theory and physiology studies. Qualitative observation of posture has been used to argue that postures are too flexed, too extended, too static, too mobile, require insufficient muscle activity or require too much. In other fields of healthcare, evidence is progressed from basic science to clinical trials before an intervention is prescribed, but postural advice has been prescribed from basic science without quantitative studies of postural behaviour. Spinal neuromuscular control can predict development of low back pain, it is affected by spinal pain, and can be trained, but studies examining these variables rarely measure the spinal position of their test subjects. There is a need for more detail of how spinal positions affect regional muscle activity. Study Objectives: The overall aims of this thesis were to quantify sagittal spinal postures in sitting for comparison within and between subjects and tasks, and to detail paraspinal and abdominal muscle activity associated with sitting postures. The studies quantified regional spinal curves in - Study I: typical posture behaviour during a computer task in comparison with standing, - Study II: postures that are achievable in sitting, - Study III: the regional muscle activity associated with sitting postures that have been clinically advocated as ‘ideal’, - Study IV: cohorts with and without a history of low back pain for comparison of regional muscle activity. Results and Conclusions: For clinical trials quantifying postural behaviour, the postural variation within subjects and task conditions in Study I demonstrated the importance of measurement over a prolonged period and subjects performing relevant tasks (as opposed to brief measures such as radiography that have been the standard for posture assessment). The use of surface tracking to quantify regional spinal curves and sagittal balance establish a foundation to investigate the effect of interventions on posture behaviour (eg. chair geometry, posture training, task variables and subject cohorts). Study I also showed that typical sitting posture for a computer task was more flexed at the thoracolumbar spinal region than when subjects deliberately ‘corrected’ their sitting posture, and both sitting postures were flexed at the lumbar region relative to standing. Study II showed that most subjects were unable to sit with spinal curves like those adopted in standing unless facilitation and feedback were provided, although these curves have been clinically advocated as ‘ideal’ posture. If clinical theories about ‘ideal’ sitting posture are correct, then teaching individuals the awareness of spinal position or skill to adopt these postures could be as important for workplace health and safety as other variables such as design and adjustment of office furniture. Study III showed three upright sitting postures that have been clinically advocated as ‘ideal’ were distinguished by incremental changes in activity of the lumbar multifidus muscles. In Study IV, individuals with a history of low back pain showed more incremental activity at the longissimus thoracis muscle to achieve the same sitting postures. If particular postures are shown to be ‘ideal’ in clinical trials, then training for these postures may need to focus on muscular strategies as well as spinal position. The distinct differences in regional muscle activity observed with spinal curves and subject cohorts (Studies III and IV) imply that studies of spinal neuromuscular control should measure or control spinal curves during testing. If spinal posture were controlled, the flat posture (flat surface from ~T5 to sacrum) would have the advantages of being achievable, commonly used in sitting and easily assessed. The flat posture also demonstrated the lowest muscle activity of the upright sitting postures examined, which may improve accuracy of determining muscle activity onset/offset used as an outcome measure for interventions, distinguishing cohorts or as a predictor for low back pain occurrence.
|
22 |
Modélisation des évolutions à long terme du trait de côte et de l'érosion côtière / Modeling long term shoreline evolution and coastal erosionTran, Hai Yen 20 September 2018 (has links)
Cette recherche porte sur des modélisation des évolutions à long terme du trait de côtes, dans laquelle on propose un modèle qui combine à la fois une contribution des processus cross-shore et celle de processus longshore pour améliorer les capacités prédictives. Le modèle cross-shore de Splinter et al. (2014) est ré-implémenté dans un but de comparaison avec le modèle combiné. Nous présentons un modèle longshore simple basé sur une approche "one-line" moyenne dans le temps. L’analyse de ce modèle longshore donne l’orientation de la plage d’équilibre par rapport à l’orientation de l’onde incidente. Il révèle également qu’une partie de la variabilité saisonnière des positions du trait de côte est due au transport par la dérive littorale. Par conséquent, la contribution longshore du modèle combiné améliore les capacités prédictives. Les prédictions du modèle sont confrontées à des mesures des positions du trait de côte de différents types de plages, comme celles de Truc Vert, en France et des plages en baie avec courbure de Narrabeen, en Australie et de Nha Trang, au Vietnam.Cette thèse offre deux nouvelles contributions précieuses. Le premier est un modèle longshore simple et l’orientation de la plage d’équilibre. Le second est un modèle combiné de long-shore et cross-shore. / This research focuses on the long-term shoreline evolution modeling, in which a combined model comprising the shoreline change due to longshore drift in a cross-shore shoreline model is proposed to improve the predictive skills of the long-term shoreline response. The cross-shore shoreline model of cite{splinter2014} is re-implemented for a purpose of comprehensive comparison with the combined model. A simplified longshore shoreline model is developed on the basis of the one-line type approach. The analysis of this longshore model yields the equilibrium beach orientation in relation to the incident wave orientation. It also reveals that part of seasonal shoreline position variability is due to the longshore transport. Therefore, the presence of the longshore model in the combined model clearly improves the model skills. The shoreline evolution models are calibrated with data from different beach types, such as a straight open beach shoreline of Truc Vert, France and embayed beach shoreline of Narrabeen, Australia and Nha Trang, Vietnam.This thesis gives two valuable contributions. The first one is a simplified longshore model and the equilibrium beach orientation. The second one is a combined longshore cross-shore phenomenological model.
|
23 |
Mapeamento da normalidade de parâmetros biomecânicos da articulação do joelho durante a sua extensão em cadeia cinética aberta sem cargaBernardes, Caroline January 2007 (has links)
A análise da cinemática articular do joelho apresenta-se como fator fundamental na compreensão da função musculoesquelética e mecânica articular. No âmbito clínico, a avaliação do padrão normal de parâmetros biomecânicos, permite a obtenção de valores de referência para comparações com diferentes grupos de indivíduos lesados ou submetidos à cirurgia. Dessa forma, o presente estudo tem como objetivo mapear a normalidade de parâmetros biomecânicos da articulação do joelho, obtidos no plano sagital, durante a extensão do joelho em cadeia cinética aberta, sem carga, utilizando videofluoroscopia. Especificamente, pretende estimar o comportamento do centro de rotação tibiofemoral e patelofemoral, distância perpendicular do ligamento patelar e efetiva dos extensores de joelho, torque de resistência do segmento perna-pé, força do ligamento patelar, força do músculo quadríceps e força de contato patelofemoral, razão entre a força do ligamento patelar e a força do músculo quadríceps, razão entre a força de contato patelofemoral e a força do músculo quadríceps, pressão patelofemoral e tilt patelar ântero-posterior. Para a determinação dos parâmetros biomecânicos foram obtidas imagens radiográficas dinâmicas, por meio de videofluoroscopia, a partir da análise da articulação do joelho no plano sagital, de vinte e cinco indivíduos, executando três repetições do exercício de extensão de joelho em cadeia cinética aberta, sem carga externa aplicada à tíbia. As imagens obtidas foram reproduzidas e digitalizadas utilizando uma placa de captura da marca Silicon Graphics 320. Foram desenvolvidas rotinas computacionais utilizando o software Matlab para processamento e análise dos dados. Os dados obtidos foram analisados estatisticamente utilizando-se o pacote estatístico SPSS, versão 13.0. Foram plotados os valores obtidos para cada parâmetro em função do ângulo de flexão do joelho, para todos os indivíduos da amostra, e realizada uma análise de regressão entre as variáveis interpoladas, obtendo-se respectivo intervalo de confiança e coeficiente de determinação (r2). A partir dos resultados obtidos, foram verificadas correlações muito forte, forte e regular entre os parâmetros do estudo e o ângulo de flexão do joelho, indicando a possibilidade de mapear a normalidade dos parâmetros cinemáticos e cinéticos da articulação do joelho. / The kinetic and kinematics analysis of the knee joint is considered to be of prime importance in the understanding of the musculoskeletal function and joint mechanics. In the clinical scope, the biomechanics evaluation of the normal standard of biomechanics parameters, allow the attainment of indexes of reference for compare different groups of injured individuals or submitted to surgery. On this way, the present study has as the main goal estimate the normality of biomechanics parameters of the knee joint, gotten in the sagittal plane, during the knee extension in open kinetic chain, without load, by means of videofluoroscopy. Specifically, it intends to estimate how the tibiofemoral and patellofemoral rotation center behave, the patellar ligament moment arm and the effective moment arm of the knee extensors muscle group, the resistance torque of the segment leg-foot, patellar ligament force, quadriceps muscle force and patellofemoral joint contact force, the ratio between the patellar ligament force and quadriceps muscle force, the ratio between patellofemoral joint contact force and quadriceps muscle force, patellofemoral pressure and the anteroposterior patellar tilt. For the determination of these biomechanics parameters, dynamic radiographic images had been gotten, by means of videofluoroscopy. From the analysis of the knee joint in the sagittal plane, from twenty-five individuals, performing three repetitions of the knee extension exercise in open kinetic chain, without applied external load to the tibia. The gotten images had been reproduced and digitalized using a capture plate - Silicon Graphics 320. There been developed specific computational routines using Matlab software for processing and analysis of the data. The gotten data had been analyzed statistically using the statistical package SPSS, version 13.0. The gotten values for each parameter related to the knee angle of flexion had been plotted, for all the individuals of the sample, and carried through an regression analysis between the interpolated variables, getting respective reliable interval and coefficient of determination (r2). In the light of these findings, correlations had been verified to be strong, very strong and also very regular among the parameters of the present study and the angle of knee flexion, indicating the possibility of estimate the normality of the kinematic and kinetic parameters of the knee joint.
|
24 |
Mapeamento da normalidade de parâmetros biomecânicos da articulação do joelho durante a sua extensão em cadeia cinética aberta sem cargaBernardes, Caroline January 2007 (has links)
A análise da cinemática articular do joelho apresenta-se como fator fundamental na compreensão da função musculoesquelética e mecânica articular. No âmbito clínico, a avaliação do padrão normal de parâmetros biomecânicos, permite a obtenção de valores de referência para comparações com diferentes grupos de indivíduos lesados ou submetidos à cirurgia. Dessa forma, o presente estudo tem como objetivo mapear a normalidade de parâmetros biomecânicos da articulação do joelho, obtidos no plano sagital, durante a extensão do joelho em cadeia cinética aberta, sem carga, utilizando videofluoroscopia. Especificamente, pretende estimar o comportamento do centro de rotação tibiofemoral e patelofemoral, distância perpendicular do ligamento patelar e efetiva dos extensores de joelho, torque de resistência do segmento perna-pé, força do ligamento patelar, força do músculo quadríceps e força de contato patelofemoral, razão entre a força do ligamento patelar e a força do músculo quadríceps, razão entre a força de contato patelofemoral e a força do músculo quadríceps, pressão patelofemoral e tilt patelar ântero-posterior. Para a determinação dos parâmetros biomecânicos foram obtidas imagens radiográficas dinâmicas, por meio de videofluoroscopia, a partir da análise da articulação do joelho no plano sagital, de vinte e cinco indivíduos, executando três repetições do exercício de extensão de joelho em cadeia cinética aberta, sem carga externa aplicada à tíbia. As imagens obtidas foram reproduzidas e digitalizadas utilizando uma placa de captura da marca Silicon Graphics 320. Foram desenvolvidas rotinas computacionais utilizando o software Matlab para processamento e análise dos dados. Os dados obtidos foram analisados estatisticamente utilizando-se o pacote estatístico SPSS, versão 13.0. Foram plotados os valores obtidos para cada parâmetro em função do ângulo de flexão do joelho, para todos os indivíduos da amostra, e realizada uma análise de regressão entre as variáveis interpoladas, obtendo-se respectivo intervalo de confiança e coeficiente de determinação (r2). A partir dos resultados obtidos, foram verificadas correlações muito forte, forte e regular entre os parâmetros do estudo e o ângulo de flexão do joelho, indicando a possibilidade de mapear a normalidade dos parâmetros cinemáticos e cinéticos da articulação do joelho. / The kinetic and kinematics analysis of the knee joint is considered to be of prime importance in the understanding of the musculoskeletal function and joint mechanics. In the clinical scope, the biomechanics evaluation of the normal standard of biomechanics parameters, allow the attainment of indexes of reference for compare different groups of injured individuals or submitted to surgery. On this way, the present study has as the main goal estimate the normality of biomechanics parameters of the knee joint, gotten in the sagittal plane, during the knee extension in open kinetic chain, without load, by means of videofluoroscopy. Specifically, it intends to estimate how the tibiofemoral and patellofemoral rotation center behave, the patellar ligament moment arm and the effective moment arm of the knee extensors muscle group, the resistance torque of the segment leg-foot, patellar ligament force, quadriceps muscle force and patellofemoral joint contact force, the ratio between the patellar ligament force and quadriceps muscle force, the ratio between patellofemoral joint contact force and quadriceps muscle force, patellofemoral pressure and the anteroposterior patellar tilt. For the determination of these biomechanics parameters, dynamic radiographic images had been gotten, by means of videofluoroscopy. From the analysis of the knee joint in the sagittal plane, from twenty-five individuals, performing three repetitions of the knee extension exercise in open kinetic chain, without applied external load to the tibia. The gotten images had been reproduced and digitalized using a capture plate - Silicon Graphics 320. There been developed specific computational routines using Matlab software for processing and analysis of the data. The gotten data had been analyzed statistically using the statistical package SPSS, version 13.0. The gotten values for each parameter related to the knee angle of flexion had been plotted, for all the individuals of the sample, and carried through an regression analysis between the interpolated variables, getting respective reliable interval and coefficient of determination (r2). In the light of these findings, correlations had been verified to be strong, very strong and also very regular among the parameters of the present study and the angle of knee flexion, indicating the possibility of estimate the normality of the kinematic and kinetic parameters of the knee joint.
|
25 |
Avaliação mecânica de seis formas de fixação interna da osteotomia sagital do ramo mandibular, em movimento de avanço com rotação anti-horária / Mechanical evaluation of six techniques for stable fixation ofthe sagittal split osteotomy after counterclockwise mandibular advancementOliveira, Leandro Benetti de [UNESP] 29 July 2016 (has links)
Submitted by LEANDRO BENETTI DE OLIVEIRA null (le_benetti@yahoo.com.br) on 2016-08-30T13:45:31Z
No. of bitstreams: 1
TESE - Leandro Benetti de Oliveira.pdf: 2195790 bytes, checksum: 21bf2ac77d2bdf1976aedf77850b0e7f (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-31T13:10:40Z (GMT) No. of bitstreams: 1
oliveira_lb_dr_arafo.pdf: 2195790 bytes, checksum: 21bf2ac77d2bdf1976aedf77850b0e7f (MD5) / Made available in DSpace on 2016-08-31T13:10:40Z (GMT). No. of bitstreams: 1
oliveira_lb_dr_arafo.pdf: 2195790 bytes, checksum: 21bf2ac77d2bdf1976aedf77850b0e7f (MD5)
Previous issue date: 2016-07-29 / Este estudo avaliou a resistência ao deslocamento vertical de seis métodos de fixação interna estáveis utilizados na osteotomia sagital do ramo mandibular (OSRM) no movimento de avanço mandibular com rotação anti-horária. Foram utilizadas sessenta hemimandíbulas sintéticas, divididas em seis grupos de 10 hemimandíbulas, todas fixadas com sistema de fixação 2,0 mm da seguinte forma: Grupo I - 1 miniplaca reta de quatro furos e quatro parafusos monocorticais de 6,0 mm; Grupo II – 1 miniplaca reta de seis furos e seis parafusos monocorticais de 6,0 mm; Grupo III - 2 miniplacas retas de quatro furos e oito parafusos monocorticais de 6,0 mm; Grupo IV - 1 placa grade de oito furos e oito parafusos monocorticais de 6,0 mm; Grupo V - 1 miniplaca reta de quatro furos com quatro parafusos monocorticais de 6,0 mm e um parafuso bicortical 2,0 x 12 mm; Grupo VI – 1 miniplaca reta de quatro furos, locking e quatro parafusos monocorticais de 6,0 mm locking. O teste mecânico foi realizado por meio da aplicação de uma força linear na região entre o primeiro pré-molar e canino, em uma máquina de ensaios mecânicos (EMIC- DL2000) com célula de carga de 10 kilogramas Newton (kN). As cargas para o deslocamento de 1, 3 e 5 mm foram registados em Newton (N) e os dados foram transmitidos para um computador. Os resultados foram avaliados utilizando a análise de variância ANOVA (p <0,001) e teste de Tukey para comparação entre os grupos. O sistema de fixação testado nas três condições de deslocamento mostrou que os grupos com duas miniplacas retas de 2,0 mm e placa grade apresentaram valores de carga mais elevados. / This study evaluated the resistance to vertical displacement of six stable fixation methods for the sagittal split ramus osteotomy (SSRO) in the mandibular advancement with counterclockwise rotation. Sixty synthetic hemimandibles were used. They were divided into six groups of 10 hemimandibles, all hemimandibles were fixed with 2.0 mm system as follows: Group I – fixation with a straight four-hole miniplate and four monocortical screws 6.0 mm; Group II – a straight six-hole miniplate and six monocortical screws 6.0 mm; Group III – two straight four-hole miniplates and eight monocortical screws 6.0 mm; Group IV – an eight-hole (grid plate) and eight monocortical screws 6.0 mm; Group V – a four-hole straight miniplate with four monocortical screws 6.0 mm and 2.0 x 12 mm bicortical screw; Group VI – a straight four-hole locking miniplate and four monocortical screws locking 6.0 mm. Biomechanical evaluation was performed by applying a linear force in the region between the canine and first premolar, using a mechanical testing machine (EMIC- DL2000) with loading cell of 10 kN. The loads at 1, 3 and 5 mm of displacement were recorded in N and the data were transmitted from the load cell to a computer. Results were analyzed using the variance analysis ANOVA (p < 0.001) and Tukey post-test for comparison between the groups. For the three displacement conditions fixation with two straight 2.0 mm plates and with the grid plate presented higher load values.
|
26 |
Análise mecânica e fotoelástica de parafusos canulados e parafusos convencionais para fixação de osteotomias sagitais : estudo comparativo / Mechanical and photoelastic analysis of conventional screws and cannulated screws for sagittal split osteotomy fixation : a comparative studyLima, Cristina Jardelino de, 1985- 25 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T11:23:33Z (GMT). No. of bitstreams: 1
Lima_CristinaJardelinode_D.pdf: 804320 bytes, checksum: f36d67c8b410aafe2f3664c02eb674ca (MD5)
Previous issue date: 2014 / Resumo: O objetivo do presente estudo foi comparar, por meio de testes mecânicos e fotoelásticos, o desempenho de parafusos canulados em relação a parafusos convencionais, ambos do sistema 2,3 mm, utilizados na fixação de osteotomia sagital do ramo mandibular. Dez réplicas de mandíbulas humanas fabricadas em poliuretano e uma em resina fotoelástica (Nacional, Jaú, SP, Brazil) foram utilizadas em cada grupo e fixadas em L invertido. Foram realizados testes de carregamento linear vertical em uma máquina de ensaio universal (Instron Corporation, Norwood, MA). O teste Shapiro-Wilk foi realizado para verificar a presença de normalidade entre os resultados (p<0,05), em seguida o teste T foi utilizado para verificar a diferença entre as médias. O teste fotoelástico foi realizado, com o auxílio de um polariscópio plano. A avaliação dos dados do teste fotoelástico foi qualitativa e descritiva. Os resultados mecânicos obtidos demonstraram diferença entre os grupos apenas no deslocamento de 1mm, no qual o parafuso canulado provou ser mais estável. Os resultados da análise fotoelástica revelaram maior tensão entre os parafusos superior anterior e inferior, sendo o parafuso posterior superior o que sofreu menor carga de estresse, o teste revelou ainda franjas de tensão na região de ramo mandibular no grupo convencional. De acordo com os resultados do presente estudo foi possível concluir que os parafusos canulados cônicos apresentaram melhor desempenho nos testes mecânicos em 1 mm de deslocamento e nos testes fotoelásticos, sendo uma opção viável para a fixação da osteotomia sagital do ramo mandibular / Abstract: The aim of the present study was to use mechanical and photoelastic tests to compare the performance of cannulated-screws with that of solid-core screws in sagittal split osteotomy fixation. Ten polyurethane mandibles, with a prefabricated sagittal split ramus osteotomy, were fixed with the inverted L technique and allocated to the following groups: CSG Group, fixed with three 2.3-canullated-screws and SCSG Group, fixed with three 2.3-solid-core-screws. Vertical linear loading tests were performed. The differences between mean values were analysed using the T test for independent samples. The photoelastic test was carried out using a polariscope. The results revealed that there were only differences between the two groups at 1 mm of displacement, at which point the cannulated-screw exhibited more resistance. The photoelastic test confirmed higher stress concentration close to the mandibular branch in the solid-core group. Cannulated-screws performed better than solid-core screws in photoelastic tests and in a mechanical test at 1 mm displacement / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
|
27 |
Análise mecânica da influência de dois desenhos de osteotomia sagital do ramo mandibular fixados com mini-placas e parafusos de titânio para diferentes posições mandibulares / Mechanical analysis of the influence of two mandibular sagittal split osteotomy designs using titanium mini plates and screws for different mandibular positionsPozzer, Leandro Souza, 1986- 23 August 2018 (has links)
Orientador: José Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:12:16Z (GMT). No. of bitstreams: 1
Pozzer_LeandroSouza_M.pdf: 2724015 bytes, checksum: 92ed84ee2d65fa61c35646c90bce649e (MD5)
Previous issue date: 2013 / Resumo: O objetivo nesta pesquisa foi analisar a resistência mecânica de duas diferentes osteotomias sagitais do ramo mandibular (OSRM) em mandíbulas de resina de poliuretano. O grupo I - osteotomia angulada proposta por Epker (1977) e o grupo II - osteotomia linear sem ângulos proposta por Farrel & Tucker (2011) fixadas com uma mini-placa de titânio com 4 furos do sistema de 2,0 mm com quatro parafusos de 5 mm variando a posição mandibular, sendo com 0 milímetros e com avanço de 3mm e 7 milímetros. O grupo I e II foram subdivididos em três subgrupos: IA/IIA (sem avanço); IB/IIB (com 3 milímetros de avanço) e IC/IIC (com 7 milímetros de avanço). As réplicas de hemi mandíbulas de poliuretano foram testadas em uma máquina de ensaio universal para carregamento linear (Instron, modelo 4411) para obter a carga de pico e o deslocamento de pico obtidos pelo Software Bluehill. Foi realizado o teste t para amostras não pareadas, considerando distribuição normal com desvio padrão semelhante entre os grupos de estudo (p <0,05). Os deslocamentos dos segmentos foram maiores em todos os subgrupos II antes da falha do sistema (p <0,05). Os deslocamentos do grupo IIA, IIB e IIC foram mais elevados do que o grupo IA, IB e IC (p<0,05). Finalmente, pode-se concluir que a OSRM mais linear (grupo II) tem comportamento mecânico melhor do que a OSRM angulada (grupo I) / Abstract: The aim of this research was to analyze the strength of two different sagittal ramus osteotomies (OSRM) in polyurethane resin mandibles. Group I - angled osteotomy proposed by Epker (1977) and group II - linear osteotomy without angles proposed by Farrel & Tucker (2011) with a fixed titanium plates with 4-hole system with four 2.0mm screws 5mm varying the mandibular position, from 0mm and 3mm and 7mm advancement. Group I and II were divided into three subgroups: IA / IIA (without advance); IB / IIB (with 3mm of advance) and IC / IIC (with 7 mm of advance). Replicas of polyurethane hemi mandibles were tested in a universal testing machine for linear loading (Instron Model 4411) for peak load and peak displacement before system failure noted by Bluehill Software. The t test for unpaired samples, considering the normal distribution with a standard deviation similar between the study groups (p <.05). The displacements of the segments were higher in all subgroups II before the system failure (p <0.05). The displacements of Group IIA, IIB and IIC were higher than Group IA, IB and IC (p <0.05). Finally, it can be concluded that the more linear OSRM (group II) has better mechanical behavior than the angled OSRM (group I) / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
|
28 |
Análise fotoelástica de influência de dois desenhos de osteotomia sagital do ramo mandibular fixados com miniplacas e parafusos de titânio para diferentes avanços mandibulares / Photoelastic analysis of two designs of sagittal splint ramus osteotomies fixed with miniplates and screws for different mandibular advanceCabral-Andrade, Valdir, 1985- 12 September 2013 (has links)
Orientador: José Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T02:13:32Z (GMT). No. of bitstreams: 1
Cabral-Andrade_Valdir_D.pdf: 2148738 bytes, checksum: d487fa80b30b5bbfc43cc5658a9ccca6 (MD5)
Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar dois desenhos diferentes de osteotomias sagitais do ramo mandibular, comparando a distribuição de tensões, utilizando como metodologia o teste fotoelástico. Para o teste de fotoelasticidade foi utilizada uma amostra composta de 06 hemimandibulas confeccionadas em resina fotoelástica, sendo o Grupo I representando a osteotomia angulada proposta por Epker (1977) e o Grupo II pela osteotomia linear sem angulos idealizada por Farrel & Tucker (2011). Os grupos I e II foram subdivididos em três subgrupos: IA/IIA (sem avanço); IB/IIB (com 3 milímetros de avanço) e IC/IIC (com 7 milímetros de avanço). Cada tipo de desenho de osteotomia sagital do ramo mandibular recebeu a mesma fixação, com uma miniplaca de titânio com 4 furos do sistema de 2,0 mm com quatro parafusos de 5 mm, sendo submetidas à incidência de carga linear a uma velocidade de deslocamento de 1mm/min. Na a análise fotoelástica, a osteotomia não angulada apresentou melhor padrão de distribuição de tensões. As tensões se concentraram ao redor do sistema de fixação na osteotomia convencional enquanto que na osteotomia não angulada as tensões não se concentraram somente ao redor do sistema de fixação, também para regiões de maior resistência do substrato, como a linha obliqua e base da mandíbula. / Abstract: The aim of this study was to evaluate two different designs of sagittal split ramus osteotomy, evaluating the stress distribution, using photoelastic test methodology. To photoelastic test used a sample of 06 hemimandibles made of photoelastic resin, with group I representing angled osteotomy proposed by Epker BN (1977) and group II by linear osteotomy without angles idealized by Farrel & Tucker (2011). Group I and II were divided into three subgroups: IA / IIA (without advance); IB / IIB (with 3mm forward) and IC / IIC (with 7 mm foward). Each type of drawing sagittal split osteotomy of the mandibular branch received the same internal fixation with a titanium plates with 4-hole system with four 2.0 mm screws of 5 mm length, with mandibular position ranging from 0 mm and an advancement of 3 mm and 7 mm in which were subjected to linear loading at a speed of 1mm/min. The results of photoelastic analysis demonstrated that not angled osteotomy showed better distribution of strain pattern. The fringes concentrated around the fixing system in the conventional osteotomy while the osteotomy is no angled strains appear not only to be concentrated around the fixation system, but to regions of higher resistance of the substrate as the base and the oblique line jaw. / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
|
29 |
Avaliação comparativa por meio de testes mecânicos, análise extensométrica e fotoelástica da influência da realização ou não da osteotomia da base nas osteotomias sagitais dos ramos mandibulares / Comparative evaluation by mechanical testing, analysis extensometric and photoelastic at the influence of basilar osteotomy in sagittal osteotomiesCabral-Andrade, Valdir, 1985- 03 September 2012 (has links)
Orientador: José Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba. / Made available in DSpace on 2018-08-20T01:39:48Z (GMT). No. of bitstreams: 1
Cabral-Andrade_Valdir_M.pdf: 2554505 bytes, checksum: 59b3398b4be124c9a3c5db0bc28f73f2 (MD5)
Previous issue date: 2012 / Resumo: O objetivo deste estudo foi avaliar a influência da osteotomia da base mandibular nas osteotomias sagitais do ramo, comparando como ela modifica a resistência mecânica dos sistemas de fixação, bem como a distribuição de tensões, utilizando como metodologia os testes mecânicos, extensiométricos e de fotoelasticidade. Para os testes mecânico e extensométrico, foi utilizada uma amostra composta de 20 hemimandíbulas confeccionadas em poliuretano, sendo 10 hemimandíbulas para cada tipo de osteotomia fixadas com parafusos bicorticais posicionais em L invertido, as quais foram submetidas à incidência de carga analisada por extensometria até a falha do sistema de fixação através de teste de carregamento linear a uma velocidade de 1mm/min. Para o teste mecânico, não existiu diferença em termos de carga e deslocamento final. Para a análise extensométrica, não existiu diferença estatisticamente significante entre os parafusos 1 e 3 entre as amostras, somente para o parafuso 2. No caso da análise fotoelástica, a osteotomia da base mostrou apresentar melhor padrão de distribuição de tensões. Apesar dessas diferenças estatísticas, clinicamente elas não devem influenciar em termos de resistência mecânica, podendo ambas ser utilizadas dependendo do caso e da preferência de cada profissional / Abstract: The aim of this study was to evaluate the osteotomy of the inferior border of the mandible, comparing the mechanical resistance of the fixation system, as the tension distribuition, using the mechanical, extensiometric and photoelastic methodology. For the mechanical and extensiometic analysis, a sample of 20 polyurethane hemimandibles were made, 10 hemimandible for each type of osteotomy, fixed with positional bicortical screws in inverted L configuration, that were submitted to linear loading with a displacement of 1 mm/min until the fixation failure, with extensiometric analysis. The mechanical tests found no difference for final loading and displacement. For the extensiometric analysis, there was no statistical difference between the screws 1 and 3, just for the screw 2. In the photoelastic analysis, the osteotomy of the inferior border of the mandible presented better stress distribution pattern. Despite those differences in the in vitro tests, the inferior border osteotomy probably does not have clinical influence in the resistance and it should be done depending on the case and the preference of the professional / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
|
30 |
Análise de corpos de prova mandibulares utilizados para avaliação de sistema de fixação óssea = Analysis of mandibular test specimens used to assess a bone fixation system / Analysis of mandibular test specimens used to assess a bone fixation systemBaccarin, Leandro Stocco, 1978- 21 August 2018 (has links)
Orientador: Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T21:56:10Z (GMT). No. of bitstreams: 1
Baccarin_LeandroStocco_M.pdf: 2096681 bytes, checksum: 04979b5f15938f19353542ca48c4d46d (MD5)
Previous issue date: 2013 / Resumo: Objetivo: O objetivo deste trabalho é avaliar, por meio de testes biomecânicos, se materiais sintéticos diferentes, empregados para a confecção de corpos de prova apresentam comportamento biomecânico diferente, em comparação aos demais, ao simular in vitro a resistência ao carregamento de um método de fixação consagrado para OSRM. Material: 30 réplicas de hemimandíbulas humana, sintéticas e padronizadas, com OSRM, divididas em três grupos de 10 amostras cada: Grupo A - plástico ABS, Grupo B - Poliamida, e Grupo C - Poliuretano. Estas foram fixadas por três parafusos bicorticais posicionais (16 mm de comprimento, sistema 2.0 mm), em disposição "L" invertido, utilizando-se guias de perfuração e avanço de 5 mm. Métodos: Cada amostra foi submetida ao carregamento linear vertical e os valores de resistência ao carregamento registrado em 1, 3, 5, 7 e 10 mm de deslocamento. As médias e desvio padrão foram comparados, empregando-se análise de variância (p<0.05) e pelo teste Tukey. Resultados: Notou-se uma tendência de menores valores no grupo B em relação aos grupos A e C. Nos deslocamentos 3 e 5 mm, houve uma diferença entre os grupos A e C para o grupo B (p<0.05). Nos deslocamentos 7 e 10 mm houve diferença entre os 3 grupos sendo os maiores valores encontrados no grupo C e os menores no grupo B (p<0.05). Conclusões: Levando-se em consideração os resultados obtidos e o comportamento de cada material utilizado como substrato, podemos considerar que ocorreram diferenças significativas entre os materiais, quando comparados entre si / Abstract: Purpose: The aim of this study was to assess through biomechanical testing if different synthetic materials used to fabricate test specimens have a different biomechanical behavior in comparison with other materials when simulating in vitro load resistance of a fixation method established for SSRO. Material: Thirty synthetic and standardized human hemimandible replicas with SSRO were divided into three groups of 10 samples each. Group A - ABS plastic; Group B - Polyamide and Group C - Polyurethane. These were fixated with three bicortical position screws (16 mm in length, 2.0mm system) in an inverted L pattern using perforation guide and 5 mm advancement. Methods: Each sample was submitted to linear vertical load and load strength values were recorded at 1, 3, 5, 7 and 10 mm of displacement. The means and standard deviation were compared using the Analysis of Variance (p<0.05) and the Tukey's test. Results: A tendency for lower values was observed in Group B in comparison with Groups A and C. At 3 and 5 mm of displacement, a difference between Groups A and C was found in comparison with Group B (p<0.05). At 7 and 10 mm of displacement a difference was found among the 3 groups, in which Group C showed the highest values and Group B the lowest (p<0.05). Conclusions: Taking into consideration the results obtained and the behavior of each material used as a substrate, significant differences occurred among the materials when compared among them / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências
|
Page generated in 0.0529 seconds