• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 7
  • 5
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 59
  • 28
  • 25
  • 24
  • 19
  • 17
  • 15
  • 12
  • 11
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Softening Efficacy of Various Solvents on Gutta-percha and Root Canal Sealer

Boman, Andreas, Selvin, Jakob January 2016 (has links)
Solvents have been used in endodontic retreatment for a long time and the dissolving effect is well proven. Latterly chloroform has come in a bad light due to its possible carcinogenicity. Despite the negative health effect it is still used in dental environment. Other more biocompatible solvents have now reached the market and tests should be performed to evaluate the softening efficacy. The purpose of this in-vitro study was to evaluate the softening efficacy of four different solvents used in endodontics; chloroform, eucalyptol, tetrachloroethylene, orange-oil and a control group. 100 simulated canals filled with gutta-percha, epoxy amine resin based sealer, zinc oxide eugenol based sealer and non eugenolcalcium hydroxide based sealer were tested with hardness measurement before and after two minutes exposure time of medicament. Non-eugenol calcium hydroxide failed to set and was excluded from the test. A Shore A durometer was used to evaluate the hardness of the materials and all data was first analyzed with Kruskal-Wallis test and then Mann-Whitney test to compare with control group. With a digital camera connected to a microscope we also took pictures to compare the impressions with the different medicaments. The result showed that chloroform and tetrachloroethylene is significant better to soften gutta-percha than control group (p < 0.05) but only chloroform significant better than control group to soften epoxy amine resin based sealer and zinc oxide eugenol based sealer (p < 0.05). Even if the result was significant, we cannot draw any conclusions due to small sample size.
22

Determinação do pH e da liberação de íons cálcio de três cimentos endodônticos quando utilizados em obturações, em conjunto com guta-percha, e da qualidade das mesmas. Avaliação realizada em longo prazo / Determination of pH, calcium ion release, and overall quality of three endodontic cements used in obturations with guta-percha. A long term evaluation

Paloma Gagliardi Minotti 11 May 2015 (has links)
O objetivo deste estudo foi avaliar o pH e a liberação de íons cálcio dos cimentos AH Plus, MTA Fillapex e Sealapex, em diferentes períodos, quando empregados em obturações de canais radiculares, bem como, a qualidade das obturações, após 1 ano de realizadas. O pH e a liberação de íons cálcio foram avaliados por meio de um peagômetro e espectrofotômetro de absorção atômica, respectivamente. A qualidade das obturações foi avaliada por meio de um estereomicroscópio. Cento e vinte e quatro pré-molares inferiores humanos extraídos, unirradiculados, foram divididos em 01 grupo controle e 02 grupos experimentais, de acordo com a padronização do diâmetro do forame apical. Em seguida, os 02 grupos experimentais foram divididos em 4 subgrupos, considerando as técnicas de instrumentação e obturação empregadas. Após o preparo dos canais radiculares cada subgrupo teve o número de dentes divididos por dois, formando novos subgrupos, de acordo com os cimentos obturadores utilizados. Imediatamente após a obturação, a raiz de cada dente foi imersa em 15 mL de água ultrapura para avaliação do pH e liberação de íons cálcio nos seguintes períodos: 1 h, 1, 3, 7, 30, 180 e 365 dias, após a obturação. Após o período de 1 ano, os dentes foram seccionados transversalmente a 2, 4, 6 mm do forame apical para análise da qualidade das obturações, analisando-se a porcentagem de cimento, guta-percha e espaços vazios na massa obturadora. Os cimentos apresentaram pH neutro, porém, aos 180 dias, os valores mostraram um ligeiro aumento quando utilizados em canais com forames de diâmetro 0,25 mm. Quando utilizados em canais com forames de diâmetro 0,45 mm, o pH mostrou-se com valores maiores para todos os períodos sem distinção do cimento. Todos os cimentos liberaram íons cálcio, com menores valores para o AH Plus. Na estereomicroscopia, observaram-se variações nas porcentagens de cimento e guta-percha, considerando-se os diâmetros foraminais e técnicas obturadoras, e porcentagem insignificante de espaços vazios. / The objective of this study was to evaluate the pH and calcium ion release of AH Plus, MTA Fillapex and Sealapex cements at different time periods when used in root canal obturations, as well as the quality of the obturations one year after being performed. The pH and calcium ion release were evaluated by means of a pH meter and an atomic absorption spectrophotometer, respectively. The quality of the obturations was evaluated using a stereomicroscope. One hundred and twenty-four extracted human uniradicular mandibular premolars were divided into 1 control and 2 experimental groups, according to the standardization of the apical foramen diameter. Next, the 2 experimental groups were divided into 4 subgroups, considering the instrumentation techniques and obturations employed. After the preparation of the root canals, each subgroup had the number of teeth divided by two, forming new subgroups, according to the sealers used. Immediately after the obturation, the root of each tooth was immersed in 15 mL of ultrapure water for the evaluation of the pH and calcium ion release in the following time periods: 1 hr, 1, 3, 7, 30, 180 and 365 days after the obturation. After the period of one year, the teeth were transversely sectioned at 2, 4 and 6 mm from the root apex to examine the quality of the obturations, analyzing the percentage of cement, gutta-percha and voids in the obturator mass. The cements presented a neutral pH, which showed slightly increase as of 180 days when used in canals with foramens of 0.25 mm diameters. When used in canals with foramens with diameters of 0.45 mm, the pH presented higher values in all periods for all cements. All cements released calcium ions, with lower values for the AH Plus. In the stereomicroscopy, there were variations in the percentages of cement and gutta-percha, considering the foraminal diameters and obturation techniques and an insignificant percentage of voids.
23

Influência do protocolo de secagem com álcool isopropílico na adesividade de diferentes cimentos obturadores de metacrilato à dentina radicular / Influence of the drying protocol with isopropyl alcohol on the adhesion of different methacrylate-based sealers to intraradicular dentin

Dias, Kleber Campioni 12 April 2012 (has links)
O presente estudo teve como objetivo avaliar a influência do protocolo de secagem com álcool isopropílico à adesividade dos cimentos AH Plus, Hybrid Root Seal e Epiphany SE à dentina radicular. Oitenta raízes de caninos foram submetidas ao preparo biomecânico e distribuídas em 2 grupos de acordo com a secagem, previamente a obturação: I- Secagem cone de papel absorvente e II- Secagem com álcool isopropílico 70%,e posteriormente distribuídas em 8 grupos (n=10): IA e IIA cimento AH Plus; IB e IIB - cimento Hybrid Root Seal; IC e IIC- cimento Epiphany SE com guta percha e ID e IID cimento Epiphany SE com Resilon. Após a obturação, 80 raízes foram seccionadas transversalmente obtendo-se 3 slices de 1,0 mm de espessura para cada terço radicular. Um slice de cada terço foi submetido ao teste de push out e tipo de falha analisado por meio de lupa estereoscópica. Os dois slices restantes foram submetidos à MEV para análise da interface adesiva e superfície do material obturador. A análise de variância evidenciou haver diferença estatisticamente significante (p<0,05) entre os materiais obturadores, o protocolo de secagem do canal radicular e a interação destes fatores. AH Plus/ guta percha obteve os maiores valores médios de resistência de união (3,83 ± 0,45 MPa), sendo estatisticamente diferente (p<0,05) dos demais. O Hybrid Root SEAL/ guta percha (3,24 ± 0,46 MPa) obteve valores intermediários, sendo estatisticamente diferente dos demais (p<0,05). O cimento obturador Epiphany SE quando associado à guta percha (0,45 ± 0,10 MPa) ou ao Resilon (0,31 ± 0,09 MPa) obteve os menores valores de adesividade, sendo estatisticamente semelhantes entre si (p>0,05) e diferentes dos demais (p<0,05). O cimento AH Plus obteve os maiores valores de adesividade independente do protocolo de secagem utilizado. Na comparação entre os protocolos, o protocolo que utilizou álcool isopropílico 70% obteve maiores valores médios de adesividade. / The purpose of the present study was to evaluate the influence of the drying protocol with isopropyl alcohol on the adhesion of the sealers AH Plus, Hybrid Root Seal and Epiphany SE to intraradicular dentin. Eighty root canals of canines were subjected to biomechanical preparation and were allocated to receive one of the following drying protocols (n=40) prior to root canal filling: I- Drying with absorbent paper point and II- Drying with 70% isopropyl alcohol. Thereafter, 8 groups (n=10) were formed according to the filling material: IA and IIA AH Plus sealer; IB and IIB - Hybrid Root Seal sealer; IC and IIC- Epiphany SE sealer with gutta-percha; and ID and IID Epiphany SE sealer with Resilon. After filling, the 80 roots were sectioned transversally to obtain three 1.0-mm-thick slices from each root third. The first slice of each third was subjected to a push-out test and the failure mode was determined with a stereoscopic lens. The other two slices were prepared for SEM to examine adhesive interface and the surface of the filling materials. Analysis of variance revealed statistically significant difference (p<0.05) among the filling materials, between the root canal drying protocols as well as for the interaction of these factors. AH Plus/gutta-percha had significantly higher (p<0.05) bond strengths (3.83 ± 0.45 MPa) than the other materials. Hybrid Root SEAL/gutta-percha (3.24 ± 0.46 MPa) had intermediate values and differed significantly from the other materials (p<0.05). Epiphany SE combined with either gutta-percha (0.45 ± 0.10 MPa) or Resilon (0.31 ± 0.09 MPa) presented the lowest bond strengths without statistically significant difference (p>0.05) from each other, but with significant difference (p<0.05) from the other materials. AH Plus present the highest bond strengths regardless of the drying protocol. Comparing the two protocols, drying of root canals with 70% isopropyl alcohol was associated with the highest bond strength values to intraradicular dentin.
24

Proliferation of Pathogenic Biofilms within Sealer-root Dentin Interfaces is Affected by Sealer Type and Aging Period

Roth, Karina Adriana 20 December 2011 (has links)
Objective: To assess biofilm proliferation within the sealer-dentin interfaces of methacrylate resin-based sealers, self-etch (SE) and total-etch (TE), and an epoxy resin-based sealer (EP). Methods: Standardized human root specimens were filled with the test materials and were aged for 1 week, 1, 3 or 6 months in saline (n=3/group). Monoclonal biofilms of Enterococcus faecalis were grown on the specimens for 7 days in continuous media reactor. The extent of biofilm proliferation of E. faecalis within the sealer-dentin interface for each material at each incubation period was assessed using fluorescence microscopy of dihydroethidium-stained specimens. Results: TE had less biofilm proliferation than EP and SE (p<0.01). Deeper biofilm proliferation was detected in SE and EP specimens aged for 1 and 3 months than those aged for 1 week or 6 months (p<0.05). Conclusion: Self-etch and epoxy resin-based sealers were more susceptible to interfacial biofilm proliferation than total-etch system at shorter incubation periods.
25

Proliferation of Pathogenic Biofilms within Sealer-root Dentin Interfaces is Affected by Sealer Type and Aging Period

Roth, Karina Adriana 20 December 2011 (has links)
Objective: To assess biofilm proliferation within the sealer-dentin interfaces of methacrylate resin-based sealers, self-etch (SE) and total-etch (TE), and an epoxy resin-based sealer (EP). Methods: Standardized human root specimens were filled with the test materials and were aged for 1 week, 1, 3 or 6 months in saline (n=3/group). Monoclonal biofilms of Enterococcus faecalis were grown on the specimens for 7 days in continuous media reactor. The extent of biofilm proliferation of E. faecalis within the sealer-dentin interface for each material at each incubation period was assessed using fluorescence microscopy of dihydroethidium-stained specimens. Results: TE had less biofilm proliferation than EP and SE (p<0.01). Deeper biofilm proliferation was detected in SE and EP specimens aged for 1 and 3 months than those aged for 1 week or 6 months (p<0.05). Conclusion: Self-etch and epoxy resin-based sealers were more susceptible to interfacial biofilm proliferation than total-etch system at shorter incubation periods.
26

Desenvolvimento e caracterização de um cimento endodôntico experimental a base de resina epóxica com adição de sais de bismuto

Schwartzer, Eduardo January 2011 (has links)
O objetivo deste trabalho foi desenvolver e caracterizar um cimento endodôntico experimental a base de resina epóxica com a adição de diferentes proporções de três sais de bismuto, seguindo os requisitos das normas ISO 6876 e ISO 4049 em busca da composição que atendesse estas normas. Para isto, foram formulados dezoito grupos com resina epóxica e adição de 20%; 40%; 60%; 80%; 100% e 120% em massa de três diferentes sais de bismuto. Foram realizados ensaios de escoamento, tempo de trabalho, tempo de presa, espessura de película, alteração dimensional, sorção e solubilidade, radiopacidade e citotoxicidade. Os resultados foram comparados com requisitos das normas ISO 6876 e 4049 e submetidos a ANOVA de duas vias (tipo de carga e concentração) e teste de Tukey com nível de significância de 5%. Os cimentos com subnitrato e subcarbonato de bismuto demonstram-se promissores, com especial destaque às formulações contendo subnitrato de bismuto por apresentarem resultados superiores. A adição de carga a partir de 80% conferiu radiopacidade satisfatória para os cimentos com subnitrato e subcarbonato de bismuto. Para os cimentos com subsalicilato de bismuto a única concentração que atendeu à norma foi de 120%. No ensaio de citotoxicidade nenhuma das formulações apresentou diferença estatística significativa quando comparado ao controle. Conclui-se que o subnitrato de bismuto e subcarbonato de bismuto apresentam características para utilização como carga e radiopacificante em cimentos endodônticos a base de resina epóxica. / The aim of this study was the development and evaluating of an experimental endodontic sealer epoxy based after addition of three different bismuth salts, according to the requirements of ISO 6876 and 4049 searching for the composition with better performance. Eighteen groups were formulated with the inclusion of 20%, 40%, 60%, 80%, 100% and 120% of three different bismuth salts, by weight, on epoxy resin. Then, flow tests, working time, setting time, film thickness, dimensional change, sorption and solubility, radiopacity and cytotoxicity were performed. Data were analyzed by two-way ANOVA (type of filler and concentration) and Tukey at a level of significance of 5%. The formulations with bismuth subsalicylate did not show suitable properties. However, cements with bismuth subnitrate and subcarbonate shown to be promising, particularly with regard to formulations containing bismuth subnitrate, wich presented superior results. The addition of 80% salt generated satisfactory radiopacity to subcarbonate and bismuth subnitrate sealers, bismuth subsalicylate had only reached satisfatory radiopacity at 120%. In the cytotoxicity assay none of the formulations showed statistical significance when compared to control. It is concluded that the formulations containing bismuth subnitrate and bismuth subcarbonate have potential use as filler in endodontic sealers.
27

Avaliação de cimentos endodônticos a base de metacrilato contendo α-fosfato tricálcico, fosfato octacálcico ou hidroxiapatita

Rostirolla, Flávia Veronezi January 2015 (has links)
Novos biomateriais para obturação do sistema de canais radiculares têm sido introduzidos no mercado ao longo dos últimos anos com o objetivo de melhorar o selamento desse sistema, bem como estimular o seu reparo, em uma tentativa de proporcionar melhores propriedades físico-químicas e bioatividade. O objetivo do presente estudo in vitro foi desenvolver e caracterizar cimentos endodônticos resinosos à base de metacrilato contendo três diferentes fosfatos de cálcio: α-fosfato tricálcio, fosfato octacálcico e hidroxiapatita nanoestruturada. Os cimentos foram formulados a partir da obtençao de uma resina base utilizando-se 70% de uretano dimetilmetacrilato (UDMA), 15% de glicerol 1,3 dimetilmetacrilato (GDMA) e 15% de etoxilado bisfenol A glicol dimetacrilato (BISEMA 6), em peso. Para produzir um cimento de cura dual, foram adicionados 0,5% mol de canforoquinona (CQ), 1% mol de di-hidroxietil p- toluidina (DHEPT), 1% mol de peróxido de benzoila (BP) e 1% mol de etil 4- dimethilaminobenzoato (EDAB). Para conferir radiopacidade aos cimentos, foram adicionados 40% de trifluoreto de itérbio (YbF3), em peso, previamente silanizado. À resina base, adicionou-se, em peso, 10% de α-fosfato tricálcico (α- TCP), fosfato octacálcico (OCP) ou hidroxiapatita (HAp), constituindo-se 3 grupos experimentais, havendo ainda um grupo ao qual não foram adicionados os fosfatos de cálcio, sendo este o grupo controle e um grupo composto pelo ccimento comercial AH Plus. Os cimentos endodônticos formados foram avaliados pelos testes de grau de conversão, radiopacidade, escoamento, espessura de filme, deposição de apatita, presença de íons cálcio em solução que simula os fluidos corporais “simulated body fluid (SBF) através de espectrometria de absorção atômica, pH, caracterização da interface cimento/dentina quanto à penetração dos cimentos nos túbulos dentinários e resistência de união. Todos grupos apresentaram radiopacidade, escoamento e espessura de filme de acordo com a ISO 6876. O grau de conversão de todos os cimentos aumentou ao longo de um período de 14 dias. Os cimentos apresentaram deposição mineral na ordem de GHAp>Gα-TCP>GOCP, com excessão dos grupos GControl e GAHPlus. Após 28 dias de imersão em SBF, todos os cimentos testados apresentaram maiores valores de resistência ao deslocamento comparados aos valores iniciais. Este estudo mostrou que cimentos endodônticos experimentais à base de metacrilato com adição de hidroxiapatita, α-fosfato tricálcico e fosfato octacálcico apresentaram deposição mineral após imersão em SBF sugerindo a bioatividade destes materiais. Os fosfatos de cálcio testados apresentaram propriedades físico-químicas adequadas. / New biomaterials for filling the root canal system have been introduced to the market over the past few years in order to improve the sealing of the system and stimulate its repair, in an attempt to provide better physicochemical properties and bioactivity. The aim of this in vitro study was to develop and characterize methacrilate-based sealers containing three different calcium phosphates: tricalcium phosphate, octacalcium phosphate and nanostructured hydroxyapatite. Cements were formulated from obtaining a base resin using 70% of dimetilmetacrilato urethane (UDMA), 15% glycerol 1.3 dimetilmetacrilato (GDMA) and 15% ethoxylated bisphenol A glycol dimethacrylate (BISEMA 6), weight. To produce a dual cure cement, were added 0.5 mol% camphorquinone (CQ), 1 mol% dihydroxyethyl p-toluidine (DHEPT), 1 mol% of benzoyl peroxide (BP) and 1 mol% ethyl 4- dimethilaminobenzoato (EDAB). To impart radiopacity to the sealers, were added 40% ytterbium trifluoride (YbF3) by weight silanized previously. In the base resin, is added by weight 10% of α-tricalcium phosphate (TCP α-), octacalcium phosphate (OCP) or hydroxyapatite (HAp), constituting 3 experimental groups, there is still a group that were not added calcium phosphate, which is the control group and a group composed of the commercial sealer AH Plus. Experimental sealers were evaluated by the degree of conversion testing, radiopacity, flow, film thickness, deposition of apatite, the presence of calcium ions in simulated body fluid solution (SBF) by atomic absorption spectrometry, pH, characterization of the interface cement/dentin and the penetration the cement in the dentinal tubules, and bond strength. All groups exhibited radiopacity, flow and film thickness in accordance with ISO 6876. The degree of conversion of all sealers increased over a period of 14 days. The sealers showed mineral deposition in order GHAp>Gα-TCP>GOCP, except for GControl and GAHPlus groups. After 28 days of immersion in SBF, all tested sealers presented greater values for resistance to dislodgement from root dentin. This study showed that experimental methacrylate-based root canal sealers with hydroxyapatite, α-tricalcium phosphate and octacalcium phosphate addition demonstrated mineral deposition after immersion in SBF, suggesting the bioactivity of these materials. All calcium phosphates tested presented suitable physicochemical properties.
28

Cimentos a base de resina metacrilato associado ao fosfato de cálcio : propriedades biológicas

Mestieri, Leticia Boldrin January 2017 (has links)
Este trabalho teve como objetivo avaliar as propriedades biológicas de cimentos experimentais a base de resina metacrilato contendo α-tricálcio fosfato (α-TCP) ou hidroxiapatita nanoparticulada (HAp) in vitro e in vivo. Para isto, os cimentos experimentais foram avaliados e comparados com AH Plus (AHP). Na etapa in vitro, os materiais foram mantidos em contato com meio de cultura por 24 horas, coletados e avaliados na concentração de 10%. Células-tronco da papila apical humana (SCAPs) foram submetidas aos ensaios de viabilidade brometo de 3-(4,5-dimetiltiazólio)-2,5-difenil tetrazólio (MTT) e sulfurodamina B (SRB) no período de 24 horas; e a bioatividade foi avaliada pela atividade da enzima fosfatase alcalina (ALP) e deposição de nódulos mineralizados pelo corante vermelho de Alizarina (AR), nos períodos de 1, 5, 10 e 15 dias. Na etapa in vivo, os materiais foram inseridos em tubos de polietileno e colocados no tecido subcutâneo de ratos para avaliação da reação inflamatória, sendo utilizado um tubo vazio como controle e avaliados os períodos de 7, 30 e 90 dias; para avaliação da deposição óssea, os cimentos α-TCP e AHP foram inseridos em cavidades confeccionadas no fêmur de ratos, sendo utilizada uma cavidade vazia como controle e avaliados os períodos de 30 e 90 dias. Para o ensaio de viabilidade e ensaios in vivo, foram utilizados os testes de Kruskal-Wallis e post hoc de Dunn; para avaliação da bioatividade in vitro foram utilizados os testes ANOVA e post hoc de Tukey (P < 0.05). HAp e AHP não apresentaram diferenças estatísticas entre si em ambos os ensaios de citotoxicidade (P> 0,05) e o α-TCP apresentou menor resultado de viabilidade no teste MTT, sendo estatisticamente diferente dos outros (P <0,05). Os ensaios de bioatividade demonstraram aumento na atividade da ALP em todos os grupos (P < 0.05). Observou-se semelhança entre os grupos no primeiro período (P > 0.05), AHP apresentou menores valores em 5 dias (P < 0.05), α-TCP apresentou os maiores valores em 10 dias (P < 0.05), e em 15 dias este cimento foi superior ao AHP (P < 0.05). AR mostrou aumento na quantidade de depósitos mineralizados após 5 dias (P < 0.05). Não houve diferença entre os grupos em 1 dia (P > 0.05), α-TCP, HAp e controle foram semelhantes aos 5 dias (P > 0.05), e em 10 e 15 dias, α-TCP apresentou os maiores valores, sendo diferente dos outros cimentos (P > 0.05). Na avaliação da resposta inflamatória in vivo, observou-se diminuição da inflamação e aumento de fibras colágenas em todos os grupos. Em 7 dias, α-TCP e HAp mostraram resultados semelhantes ao controle CT (P>0.05) e diferentes do AHP (P < 0.05), que foi o único grupo a apresentar células-gigantes neste período. Na avaliação da deposição óssea, houve aumento na deposição de 30 para 90 dias nos grupos α-TCP e controle (P < 0.05), e estes grupos apresentaram resultados semelhantes em 90 dias (P > 0.05), diferindo do AHP (P < 0.05). Conclui-se que a associação de fosfatos de cálcio à resina metacrilato apresentou bons resultados de biocompatibilidade e bioatividade in vitro e in vivo, apresentando potencial para serem utilizados como cimentos obturadores na prática clínica. / This study aimed to evaluate the biological properties of experimental sealers containing α-tricalcium phosphate (α-TCP) or nanoparticulate hydroxyapatite (HAp) in a methacrylate resin-base in vitro and in vivo. For this, the experimental sealers were evaluated and compared with AH Plus (AHP). At the in vitro assays, the materials were kept in contact with culture medium for 24 hours, collected and evaluated at concentrations of 100% and 10%. Stem cells from human apical papilla (SCAPs) were submitted to 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and sulfurodamine B (SRB) viability assays for 24 hour; and bioactivity was evaluated by alkaline phosphatase enzyme activity (ALP) and deposition of mineralized nodules by Alizarin Red staining (AR), for 1, 5, 10 and 15 days. At in vivo assays, the materials were inserted in polyethylene tubes and placed in subcutaneous tissue of rats to evaluate the inflammatory reaction, using an empty tube as control and evaluating the periods of 7, 30 and 90 days; to evaluate bone deposition, α-TCP and AHP cements were inserted into cavities made in the femur of rats, using an empty cavity as control and evaluating the periods of 30 and 90 days. For viability and in vivo assays, Kruskal-Wallis and Dunn’s post hoc tests were used; for bioactivity, ANOVA and Tukey's post hoc tests were used (P < 0.05). HAp and AHP did not presented statistical differences from each other in both citotoxicity assays (P > 0.05), and α-TCP presented a lower viability result in MTT assay, being statistically different from the other sealers (P < 0.05). The bioactivity assays showed an increase in ALP activity for all groups (P < 0.05). Similar results were found between the groups at the first period (P > 0.05), AHP had the lowest values at 5 days (P < 0.05), α-TCP presented the highest values at 10 days (P < 0.05), and at 15 days, this sealer’s values were higher than AHP (P < 0.05). AR showed an increase in the amount of mineralized deposits after 5 days for all sealers (P < 0.05). No difference between groups were found at 1 day (P > 0.05), α-TCP, HAp and control were similar at 5 days (P > 0.05), and at 10 and 15 days, α-TCP presented the highest values, being different of the other sealers (P > 0.05). Regarding the evaluation of the inflammatory response in vivo, there was a decrease in inflammation and increase of collagen fibers in all groups. At 7 days, α-TCP and HAp showed similar results to the control (P > 0.05) and different from AHP (P < 0.05), which was the only group to present giant cells in this period. In the evaluation of bone deposition, there was an increase in deposition from 30 to 90 days for α-TCP and control groups (P < 0.05), and these groups presented similar results in 90 days (P > 0.05), differing from the AHP (P < 0.05). It was concluded that the association of calcium phosphates and methacrylate resin showed good biocompatibility and bioactivity results in vitro and in vivo, presenting potential to be used as endodontic sealers in clinical practice.
29

Análise da remoção da smear layer e penetração intratubular do cimento obturador após diferentes protocolos de irrigação - estudo em microscopia eletrônica de varredura e confocal a laser / Analysis of smear layer removal and tubular dentine sealer penetration after different irrigation protocols - a study performed by scanning electron and laser confocal microscopy

Ricardo Machado 23 April 2015 (has links)
O objetivo do presente estudo foi avaliar a remoção da smear layer e a penetração intratubular do cimento obturador AH Plus utilizando diferentes protocolos de irrigação. Após aprovação do Comitê de Ética em Pesquisa da Faculdade de Odontologia de Ribeirão Preto - FORP/USP, noventa incisivos centrais superiores foram selecionados e fornecidos pelo banco de dentes da mesma instituição. Estes foram radiografados no sentido mésio - distal e vestíbulo - lingual para comprovar a presença de canais únicos, sem curvaturas abruptas, reabsorções ou tratamentos endodônticos prévios. Após a remoção da porção coronal para a obtenção de raízes com comprimentos padronizados de 15 milímetros, os diâmetros anatômicos foram determinados e as instrumentações realizadas por meio da técnica coroa ápice estabelecendo os diâmetros cirúrgicos utilizando 3 instrumentos acima dos anatômicos. Durante este processo, os espécimes foram divididos em seis grupos de acordo com os protocolos de irrigação: Grupo 1 (controle - n. 15) - 2,5ml de água destilada a cada troca de instrumentos e 2,5ml de água destilada por 3 minutos ao final da instrumentação; Grupo 2 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de hipoclorito de sódio a 2,5% por 3 minutos ao final da instrumentação; Grupo 3 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 4 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de EDTA a 17% a cada troca de instrumentos + 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 5 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação; Grupo 6 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de ácido cítrico a 10% a cada troca de instrumentos + 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação. Após esta fase, cinco espécimes de cada grupo foram clivados no sentido mésio - distal para avaliação da remoção da smear layer em microscopia eletrônica de varredura por meio da análise de 3 imagens de cada terço em aumentos de 300, 1000 e 2000 vezes. Esta variável foi determinada por um score qualitativo estabelecido pelo consenso de 3 avaliadores calibrados. Os demais espécimes foram obturados pela técnica de condensação lateral com cones principais correspondentes ao último instrumento associados ao cimento AH Plus corado com Rodamina B, cones acessórios B8 e mantidos em ambiente com 100% de umidade por 7 dias. Em seguida, os espécimes foram seccionados transversalmente para obtenção de slices de aproximadamente 2mm de espessura em cada terço (cervical, médio e apical) e as faces cervicais submetidas a um tratamento metalográfico para análise da penetração intratubular do cimento obturador em microscopia confocal a laser. Os melhores índices de remoção de smear layer e as maiores porcentagens de penetração intratubular do cimento foram obtidos pelos grupos onde as soluções quelantes foram utilizadas (G3, G4, G5 e G6) com diferenças estatisticamente significantes (p<0,05) em relação aos grupos onde utilizou - se somente a água destilada (G1) e o hipoclorito de sódio a 2,5% (G2) durante o processo de instrumentação. Não foram observadas vantagens em relação ao uso associado do EDTA a 17% e do ácido cítrico a 10% ao hipoclorito de sódio pela ausência de diferenças estatísticas significantes entre os grupos 3 e 4 e 5 e 6, respectivamente. / The aim of this study was to evaluate the smear layer removal and tubular dentine sealer penetration of AH Plus after different irrigation protocols. After approval of the study by the Ethics Committee of the Ribeirão Preto Dental School - FORP/USP, ninety maxillary central incisors were selected and supplied by the tooth bank of the same institution. The teeth were radiographed in the mesiodistal and buccolingual directions to verify the presence of single canals, without abrupt curvatures, resorption or previous endodontic treatment. The coronal portion was removed and roots lengths were standardized at 15 mm. The anatomic diameters were then determined and instrumentations were carried out by the crown-down technique, using 3 higher-diameter instruments to establish the surgical diameters. During this process, the specimens were divided into six groups, according to the following irrigation protocols: Group 1 (control - n. 15) - 2.5ml of distilled water at each change of instruments + 2.5ml of distilled water for 3 minutes at the end of the instrumentation; Group 2 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5 ml of 2.5% sodium hypochlorite for 3 minutes at the end of the instrumentation; Group 3 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 4 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5ml of 17% EDTA at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 5 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 10% citric acid for 3 minutes at the end of the instrumentation; Group 6 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5 ml of 10% citric acid at each change of instruments + 2.5 ml of 10% citric acid for 3 minutes at the end of the instrumentation. Following this phase, five specimens from each group were cleaved in the mesiodistal direction to evaluate the smear layer removal by scanning electron microscopy. Evaluation was performed by analyzing 3 images of each third at 300, 1000 and 2000X. This variable was determined by a qualitative score established by the consensus of 3 calibrated examiners. The remaining specimens were filled using lateral condensation with AH Plus sealer labeled with Rhodamine B and kept in an environment with 100% humidity for 7 days. Then, the specimens were sectioned to obtain approximately 2 mm thick slices of each third (cervical, middle and apical). The cervical surfaces were subjected to metallographic treatment for analysis of the tubular dentine sealer penetration by confocal laser microscopy. The highest smear layer removal rates and tubular dentine sealer penetration percentages were obtained by the groups that used chelating solutions (G3, G4, G5 and G6). These showed statistically significant differences (p<0.05) compared with the groups that used just distilled water (G1) and 2.5% sodium hypochlorite (G2) during instrumentation. No benefits were observed for the combined use of 17% EDTA or 10% citric acid with 2.5% sodium hypochlorite, considering that there were no statistically significant differences between groups 3 and 4, and between 5 and 6, respectively.
30

Desenvolvimento e caracterização de um cimento endodôntico experimental a base de resina epóxica com adição de sais de bismuto

Schwartzer, Eduardo January 2011 (has links)
O objetivo deste trabalho foi desenvolver e caracterizar um cimento endodôntico experimental a base de resina epóxica com a adição de diferentes proporções de três sais de bismuto, seguindo os requisitos das normas ISO 6876 e ISO 4049 em busca da composição que atendesse estas normas. Para isto, foram formulados dezoito grupos com resina epóxica e adição de 20%; 40%; 60%; 80%; 100% e 120% em massa de três diferentes sais de bismuto. Foram realizados ensaios de escoamento, tempo de trabalho, tempo de presa, espessura de película, alteração dimensional, sorção e solubilidade, radiopacidade e citotoxicidade. Os resultados foram comparados com requisitos das normas ISO 6876 e 4049 e submetidos a ANOVA de duas vias (tipo de carga e concentração) e teste de Tukey com nível de significância de 5%. Os cimentos com subnitrato e subcarbonato de bismuto demonstram-se promissores, com especial destaque às formulações contendo subnitrato de bismuto por apresentarem resultados superiores. A adição de carga a partir de 80% conferiu radiopacidade satisfatória para os cimentos com subnitrato e subcarbonato de bismuto. Para os cimentos com subsalicilato de bismuto a única concentração que atendeu à norma foi de 120%. No ensaio de citotoxicidade nenhuma das formulações apresentou diferença estatística significativa quando comparado ao controle. Conclui-se que o subnitrato de bismuto e subcarbonato de bismuto apresentam características para utilização como carga e radiopacificante em cimentos endodônticos a base de resina epóxica. / The aim of this study was the development and evaluating of an experimental endodontic sealer epoxy based after addition of three different bismuth salts, according to the requirements of ISO 6876 and 4049 searching for the composition with better performance. Eighteen groups were formulated with the inclusion of 20%, 40%, 60%, 80%, 100% and 120% of three different bismuth salts, by weight, on epoxy resin. Then, flow tests, working time, setting time, film thickness, dimensional change, sorption and solubility, radiopacity and cytotoxicity were performed. Data were analyzed by two-way ANOVA (type of filler and concentration) and Tukey at a level of significance of 5%. The formulations with bismuth subsalicylate did not show suitable properties. However, cements with bismuth subnitrate and subcarbonate shown to be promising, particularly with regard to formulations containing bismuth subnitrate, wich presented superior results. The addition of 80% salt generated satisfactory radiopacity to subcarbonate and bismuth subnitrate sealers, bismuth subsalicylate had only reached satisfatory radiopacity at 120%. In the cytotoxicity assay none of the formulations showed statistical significance when compared to control. It is concluded that the formulations containing bismuth subnitrate and bismuth subcarbonate have potential use as filler in endodontic sealers.

Page generated in 0.0425 seconds