• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação in vitro da rugosidade superficial e manutenção dos selantes de superfícies para resinas compostas submetidos à escovação

Bonatto, Fernanda January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-05-28T11:37:27Z No. of bitstreams: 1 448373.pdf: 984719 bytes, checksum: e51e892e5e4e07ff9dd9d9321a1c3b79 (MD5) / Made available in DSpace on 2013-05-28T11:37:27Z (GMT). No. of bitstreams: 1 448373.pdf: 984719 bytes, checksum: e51e892e5e4e07ff9dd9d9321a1c3b79 (MD5) / Objetivos : 1) avaliar a rugosidade de três selantes de superfície aplicados sobre uma resina composta quando submetidos à escovação simulada por diferentes períodos; 2) avaliar, com auxílio da microscopia eletrônica de varredura, a presença dos selantes de superfície após escovação simulada; 3) avaliar se o tipo de dentifrício pode diminuir o tempo de vida útil dos selantes de superfície. Materiais e Métodos : Cento e oito corpos-de-prova foram confeccionados com resina Amelogen Plus, divididos em 6 grupos (n=18) conforme o tipo de selante de superfície (Fortify (F), BisCover LV (B) e Permaseal (P)) e dentifrícios (Colgate total 12 Clean Mint (CT) e Colgate total 12 Professional Whitening (PW)). As amostras foram submetidas a ciclos de escovação, simulando períodos de 6 meses, 12 meses, 18 meses e 24 meses. Após cada período, as amostras tiveram a rugosidade de superfície mensurada. Um grupo adicional de 48 amostras foi realizado para análise em M.E.V. Os resultados foram submetidos ao teste de ANOVA com três fatores fixos (selantes, tempo e dentifrício) e de Tukey (α = 5%). Resultados : BisCover apresentou a menor média de rugosidade de superfície (0,06 μm) quando comparado com os selantes Fortify (0,09 μm) e Permaseal (0,08 μm), os quais não foram estatisticamente diferentes entre si. O Fortify, em 12 meses de escovação, apresentou a maior média de rugosidade (0,13 μm). A média de rugosidade para o dentifrício CT foi menor (0,07 μm) se comparado com o PW (0,08 μm), sendo estatisticamente distintos. A rugosidade de superfície aumentou até os 12 meses de escovação simulada (0,04 μm, 0,08 μm e 0,11 μm), diminuindo no 18° mês (0,08 μm) até os 24 meses de escovação (0,07 μm). Conclusões : o selante Fortify apresentou a maior média de rugosidade em 12 meses de escovação simulada, e os menores valores de rugosidade foram obtidos pelo BisCover. Através da M.E.V, observou-se que nenhum dos selantes utilizados no estudo foi removido completamente da resina até os 24 meses de escovação. / Objectives : 1) to evaluate the roughness of three surface sealants applied on a composite resin when subjected to simulated toothbrushing for different periods, 2) to evaluate, with the aid of scanning electron microscopy, the presence of surface sealants after simulated toothbrushing; 3) evaluating whether the type of dentifrice may shorten the life of the sealing surface. Materials and Methods : One hundred and eight bodies of the specimens were fabricated with resin Amelogen Plus, divided into 6 groups (n = 18) according to the type of surface sealant (Fortify (F), BisCover LV (B) and Permaseal (P)) and toothpaste (Colgate Total 12 Clean Mint (CT) and Colgate Total Professional Whitening 12 (PW)). The samples were subjected to brushing cycles, simulating periods of 6 months, 12 months, 18 months and 24 months. After each period, the samples had a surface roughness measured. An additional group of 48 samples was conducted for SEM analysis. The results were analyzed by ANOVA with three fixed factors (sealants, time and toothpaste) and Tukey's test (α = 5%). Results : BisCover had the lowest average surface roughness (0.06 μm) compared with sealants Fortify (0.09 μm) and Permaseal (0.08 μm), which were not statistically different. The Fortify on 12 months of brushing, had the highest average roughness (0.13 μm). The average roughness for the dentifrice CT was lower (0.07 μm), compared to the PW (0.08 μm) and was statistically different. The roughness increased up to 12 months of simulated brushing (0.04 μm, 0.08 μm and 0.11 μm), decreasing at the 18th month (0.08 μm) up to 24 months of brushing (0.07 μm). Conclusions : The sealant Fortify had the highest average roughness in 12 months of simulated toothbrushing, and the lowest roughness values were obtained by BisCover. Through SEM, it was observed that none of the seals used in the study was completely removed from the resin by 24 months of brushing.
2

Capacidade seladora e adaptação marginal proporcionadas por alguns materiais quando utilizados em perfurações na região de furca de molares humanos / SEALING CAPACITY AND MARGINAL ADAPTATION BY SOME MATERIALS WHEN UTILIZED UNDER FURCATION PERFORATIONS OF HUMAN MOLARS

Silva Neto, Ulisses Xavier da 26 April 2002 (has links)
Foram analisadas a capacidade seladora e a adaptação marginal in vitro, de alguns materiais quando utilizados em perfurações na região de furca. Utilizou-se cento e quatro dentes molares humanos extraídos superiores e/ou inferiores, dos quais oitenta e oito foram usados para analisar o selamento e dezesseis para a adaptação marginal dos materiais seladores utilizados sob M.E.V. Os dentes tiveram suas coroas eliminadas em um nível logo acima do assoalho da câmara pulpar, e as raízes, logo abaixo da região de furca. Em seguida, realizou-se a impermeabilização de toda a superfície externa dos espécimes, e a sua inclusão em uma base de silicona pesada. Ao centro do assoalho de cada espécime, foi realizada uma perfuração com 1,4 mm de diâmetro. Frontalmente às perfurações, na base de silicona, foram realizadas depressões onde foram posicionadas, imediatamente antes da obturação, bolinhas de algodão padronizadas umedecidas com água destilada. Em cada grupo, formou-se 2 subgrupos, um recebendo uma matriz de gesso Paris e o outro não. As obturações das perfurações foram, então, realizadas com os seguintes materiais: Grupo I (MTA – Angelus), Grupo II (ProRoot – MTA), Grupo III (Super-EBA), Grupo IV (MBP-c). Posteriormente, os espécimes foram imersos em solução corante rhodamine B 0,2% a 37°C, por 48 horas. Após lavagem dos espécimes e remoção da impermeabilização, os mesmos foram seccionados longitudinalmente, expondo-se as perfurações e as possíveis marcas de infiltração. A leitura da infiltração marginal, foi realizada por meio de um microscópio óptico, utilizando-se de escores numéricos – 0, 1, 2 e 3, para sua quantificação. Para visualização da adaptação marginal dos materiais obturadores às paredes dentinárias, os espécimes foram submetidos à mesma metodologia descrita anteriormente, exceto quanto à impermeabilização da superfície externa e a imersão na solução corante. Após a presa dos cimento os espécimes, foram submetidos ao M.E.V., obtendo-se fotomicrografias com aumento de 50 e 200X. Os resultados referentes à infiltração marginal, foram submetidos aos testes estatísticos, permitindo as seguintes conclusões: Quando utilizado isoladamente (sem a matriz), o cimento MBP-c apresentou os menores índices de infiltração marginal, seguido pelo Super-EBA, havendo diferença estatística entre esses e os cimentos ProRoot – MTA e MTA – Angelus (p<0,001). Na presença da matriz de gesso Paris, o cimento MBP-c apresentou os menores índices de infiltração marginal, havendo diferença estatística entre esse e os cimentos ProRoot – MTA e MTA – Angelus (p<0,05); A matriz de gesso Paris influenciou negativamente, com diferenciação estatística (p<0,05), o selamento produzido pelos cimentos Super-EBA e o MBP-c (p<0,05); A utilização da matriz de gesso Paris evitou o extravasamento dos materiais seladores; Foi observada uma relação direta entre a adaptação marginal e a capacidade de selamento do material. / This paper analyses the sealing capacity and the marginal adaptation in vitro of a few materials when utilized under furcal perforations. The experiment utilized a hundred and forty four extracted human mandibular and maxillary molars. From the total amount, eighty-eight were utilized for checking the sealing and sixteen for checking the marginal adaptation under M.E.V. The teeth had its crowns seccionated and removed in an upper level close to the top of the floor of the pulp chamber, and the roots close to the bottom of the furcal area. Following that , there was an impermeabilization of the whole external surface of the specimens, and the inclusion in a heavy silicon base. There was a 1.4mm perforation to the center of the floor of each specimen. Up front to the perforation, in the silicon base, depressions were made and little cotton pellets moisturized with distilled water were positioned before the obturation. In each group, subgroups were created. One receiving a Plaster of Paris matrix and the other no. The obturation of perforations were then, made with the following materials: Group I (MTA – Angelus), Group II (ProRoot – MTA), Group III (Super-EBA), Group IV (MBP-c). After that, the specimens were submerged in a rhodamine B 0,2% solution at 37°C, for 48 hours. After cleaning the roots and removing the impermeabilization, they were seccionated in the axis direction, thus revealing the perforations and possible leakage marks. The reading of the marginal adaptation was performed by an optical microscope utilizing numerical scores 0, 1, 2 e 3. In order to visualize the marginal adaptation of the obturation materials in regards to the dentinal walls, the specimens were introduced to the same methodology as described before, except for the steps of impermeabilization of the external surface and the submerging in dye. After cement placement, the M.E.V was applied and photos with 50X e 200X were obtained. The results regarding the marginal infiltration were statistically tested. Thus allowing the following conclusions: when isolated and tested (without the matrix), the cement MBP-c presented the smallest coefficient of marginal leakage, followed by the Super-EBA. There was a statistical significance between those and the cements ProRoot – MTA e MTA – Angelus (p<0,001). In the presence of the Plaster of Paris matrix, the cement MBP-c presented the smallest levels of marginal leakage, having statistical significance between those and the cements ProRoot – MTA e MTA – Angelus (p<0,05); There was a significant statistical variation, in the marginal leakage of the cements due to the presence of the Plaster of Paris matrix to the Super-EBA and to MBP-c (p<0,05). The utilization of the Plaster of Paris matrix avoided the leakage of the sealing materials. A direct relationship could be found between the marginal adaptation and the material sealing capacity
3

Influência do selamento dentinário imediato na polimerização de materiais de moldagem e na resistência à fratura de coroa em cerâmica

Ghiggi, Paula Cristine January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-05-27T11:49:48Z No. of bitstreams: 1 448385.pdf: 890714 bytes, checksum: 62d158637f85cd4da3fefcd711a75370 (MD5) / Made available in DSpace on 2013-05-27T11:49:48Z (GMT). No. of bitstreams: 1 448385.pdf: 890714 bytes, checksum: 62d158637f85cd4da3fefcd711a75370 (MD5) / A primeira etapa deste estudo avaliou, in vitro, a interação entre materiais resinosos utilizados na técnica do selamento dentinário imediato (SDI) e materiais de moldagens associado a duas técnicas para reduzir/eliminar a camada inibida de oxigênio. A dentina oclusal de 35 terceiros molares humanos foi exposta, seguido de acabamento com lixa de carbeto de silício de granulação 400. Os dentes foram divididos aleatoriamente em 2 grupos: grupo 1- moldagem com silicone por adição Express XT; grupo 2 – moldagem com o poliéter Impregum. Os grupos 1 e 2 foram divididos em 14 subgrupos: grupo 1a e 2a: controle; grupos 1b e 2b: SDI com Clearfil SE Bond (CSE); grupos 1c e 2c: SDI with CSE + polimerização adicional com gel a base de glicerina; grupos 1d e 2d: SDI com CSE + álcool; grupos 1e e 2e: SDI com CSE e Protect Liner F (PLF); grupos 1f e 2f: SDI com CSE e PLF + polimerização adicional com gel a base de glicerina; grupos 1g e 2g: SDI com CSE e PLF + álcool. Cada superfície dentária foi fotografada com uma câmera digital. As imagens foram salvas e utilizadas para avaliar a presença de material de moldagem sobre a estrutura dentária. Por meio de uma análise qualitativa, observou-se que o SDI realizado com o CSE ou com PLF interagiram com o Express XT e com o Impregum. A aplicação do gel a base de glicerina e do álcool impediram a interação do CSE com o Express XT e do PLF com o Impregum; no entanto, estes mesmos tratamentos não foram totalmente efetivos para o CSE com o Impregum e para o PLF com o Express XT. A segunda etapa deste estudo avaliou a espessura do sistema adesivo, resina de baixa viscosidade e cimento resinoso em preparos para coroas totais, e a influência na resistência à fratura de coroa total em cerâmica. Sessenta pré-molares superiores receberam prepares para coroa total e foram divididos em 3 grupos de acordo com o material aplicado na técnica do SDI: grupo 1 – controle; grupo 2 - CSE; G3 – CSE + PLF. Após moldagem com silicone por adição, os preparos receberam provisórios confeccionados com resina acrílica. As restaurações cerâmicas com IPS Empress 2 foram confeccionadas e cimentadas sobre os preparos com Panavia F. Dez amostras de cada grupo foram submetidos ao teste de resistência à fratura e 10 espécimes foram seccionados no sentido vestíbulo-lingual para avaliar a espessura do Panavia F, CSE e PLF em 10 posições diferentes com o auxílio de um microscópio. De acordo com ANOVA e teste de Tukey, a carga de fratura do grupo 3 (1300 N) foi estatisticamente superior ao grupo 1 (1001 N) (p<0.01) e o grupo 2 (1189 N) não apresentou diferença estatística com os grupos 1 e 3. A maior espessura de película do CSE Bond foi obtida na parte côncava dos prepares. O PLF apresentou a espessura mais uniforme em diferentes posições. A espessura do Panavia F foi maior na face oclusal dos preparos. A espessura da película formada pelo CSE e PLF aumentou a resistência à fratura de coroas cerâmicas confeccionadas com IPS Empress 2. / The first section of this study evaluated the interaction between resin materials used in the immediate dentin sealing (IDS) techniques and impression materials under two different techniques to reduce/eliminate the oxygen-inhibition layer. The occlusal dentin of 35 human molars was exposed and finished with 400 grit silicon carbide sandpaper. Teeth were randomly divided into 2 groups: group 1 – impression with vinyl polysiloxane Express XT, group 2 – impression with polyether Impregum. Groups 1 and 2 were divided into 14 subgroups: groups 1a e 2a: control groups; groups 1b e 2b: IDS with Clearfil SE Bond (CSE); groups 1c e 2c: IDS with CSE + additional polymerization with glycerine jelly; groups 1d e 2d: IDS with CSE + alcohol; groups 1e e 2e: IDS with CSE and Protect Liner F (PLF); groups 1f e 2f: IDS with CSE and PLF + additional polymerization with glycerin jelly; groups 1g e 2g: IDS with CSE and PLF + alcohol. Each tooth surface was photographed using a digital camera. The images saved were used to examine the presence of impression material left on the treated tooth surface. It was observed that IDS performed with CSE or with the PLF interacted with the Express XT and with the Impregum. The application of glycerine jelly and alcohol avoided the interaction of CSE with the Express XT and of the PLF with the Impregum; however, these treatments were not totally effective to avoid the interaction of CSE with the Impregum and of PLF with the Express XT. The second section of this study evaluate, in vitro, the thickness of the adhesive, low-viscosity microfilled resin, and resin cement on full crown preparations, and its effect on the fracture load of a reinforced all-ceramic crown. Sixty maxillary premolars received full crown preparation and were divided in 3 groups according to the material applied for the immediate dentin sealing: G1 – control; G2 – CSE Bond; G3 – CSE Bond + PLF. After taking the impression with polyvinyl siloxane, the preparations were temporized with acrylic resin crowns. IPS Empress 2 restorations were fabricated, and cemented to the preparations with Panavia F. Ten specimens of each group were submitted to fracture load testing, and the other 10 specimens were sectioned buccolingually, and the thicknesses of Panavia F, CSE Bond and PLF were measured in 10 different positions using a microscope. According to ANOVA and Tukey’s test, the fracture load of group 3 (1300 N) was statistically higher than group 1 (1001 N) (p<0.01). Group 2 (1189 N) was not statistically different from groups 1 and 3. The higher thickness of the CSE Bond was obtained in the concave part of the preparation. The PLF presented a more uniform range of values at different positions. The thickness of Panavia F was higher in the occlusal portion of the preparation. The film thickness formed by CSE Bond and PLF increased the fracture load of the IPS Empress 2 ceramic crown.
4

Capacidade seladora e adaptação marginal proporcionadas por alguns materiais quando utilizados em perfurações na região de furca de molares humanos / SEALING CAPACITY AND MARGINAL ADAPTATION BY SOME MATERIALS WHEN UTILIZED UNDER FURCATION PERFORATIONS OF HUMAN MOLARS

Ulisses Xavier da Silva Neto 26 April 2002 (has links)
Foram analisadas a capacidade seladora e a adaptação marginal in vitro, de alguns materiais quando utilizados em perfurações na região de furca. Utilizou-se cento e quatro dentes molares humanos extraídos superiores e/ou inferiores, dos quais oitenta e oito foram usados para analisar o selamento e dezesseis para a adaptação marginal dos materiais seladores utilizados sob M.E.V. Os dentes tiveram suas coroas eliminadas em um nível logo acima do assoalho da câmara pulpar, e as raízes, logo abaixo da região de furca. Em seguida, realizou-se a impermeabilização de toda a superfície externa dos espécimes, e a sua inclusão em uma base de silicona pesada. Ao centro do assoalho de cada espécime, foi realizada uma perfuração com 1,4 mm de diâmetro. Frontalmente às perfurações, na base de silicona, foram realizadas depressões onde foram posicionadas, imediatamente antes da obturação, bolinhas de algodão padronizadas umedecidas com água destilada. Em cada grupo, formou-se 2 subgrupos, um recebendo uma matriz de gesso Paris e o outro não. As obturações das perfurações foram, então, realizadas com os seguintes materiais: Grupo I (MTA – Angelus), Grupo II (ProRoot – MTA), Grupo III (Super-EBA), Grupo IV (MBP-c). Posteriormente, os espécimes foram imersos em solução corante rhodamine B 0,2% a 37°C, por 48 horas. Após lavagem dos espécimes e remoção da impermeabilização, os mesmos foram seccionados longitudinalmente, expondo-se as perfurações e as possíveis marcas de infiltração. A leitura da infiltração marginal, foi realizada por meio de um microscópio óptico, utilizando-se de escores numéricos – 0, 1, 2 e 3, para sua quantificação. Para visualização da adaptação marginal dos materiais obturadores às paredes dentinárias, os espécimes foram submetidos à mesma metodologia descrita anteriormente, exceto quanto à impermeabilização da superfície externa e a imersão na solução corante. Após a presa dos cimento os espécimes, foram submetidos ao M.E.V., obtendo-se fotomicrografias com aumento de 50 e 200X. Os resultados referentes à infiltração marginal, foram submetidos aos testes estatísticos, permitindo as seguintes conclusões: Quando utilizado isoladamente (sem a matriz), o cimento MBP-c apresentou os menores índices de infiltração marginal, seguido pelo Super-EBA, havendo diferença estatística entre esses e os cimentos ProRoot – MTA e MTA – Angelus (p<0,001). Na presença da matriz de gesso Paris, o cimento MBP-c apresentou os menores índices de infiltração marginal, havendo diferença estatística entre esse e os cimentos ProRoot – MTA e MTA – Angelus (p<0,05); A matriz de gesso Paris influenciou negativamente, com diferenciação estatística (p<0,05), o selamento produzido pelos cimentos Super-EBA e o MBP-c (p<0,05); A utilização da matriz de gesso Paris evitou o extravasamento dos materiais seladores; Foi observada uma relação direta entre a adaptação marginal e a capacidade de selamento do material. / This paper analyses the sealing capacity and the marginal adaptation in vitro of a few materials when utilized under furcal perforations. The experiment utilized a hundred and forty four extracted human mandibular and maxillary molars. From the total amount, eighty-eight were utilized for checking the sealing and sixteen for checking the marginal adaptation under M.E.V. The teeth had its crowns seccionated and removed in an upper level close to the top of the floor of the pulp chamber, and the roots close to the bottom of the furcal area. Following that , there was an impermeabilization of the whole external surface of the specimens, and the inclusion in a heavy silicon base. There was a 1.4mm perforation to the center of the floor of each specimen. Up front to the perforation, in the silicon base, depressions were made and little cotton pellets moisturized with distilled water were positioned before the obturation. In each group, subgroups were created. One receiving a Plaster of Paris matrix and the other no. The obturation of perforations were then, made with the following materials: Group I (MTA – Angelus), Group II (ProRoot – MTA), Group III (Super-EBA), Group IV (MBP-c). After that, the specimens were submerged in a rhodamine B 0,2% solution at 37°C, for 48 hours. After cleaning the roots and removing the impermeabilization, they were seccionated in the axis direction, thus revealing the perforations and possible leakage marks. The reading of the marginal adaptation was performed by an optical microscope utilizing numerical scores 0, 1, 2 e 3. In order to visualize the marginal adaptation of the obturation materials in regards to the dentinal walls, the specimens were introduced to the same methodology as described before, except for the steps of impermeabilization of the external surface and the submerging in dye. After cement placement, the M.E.V was applied and photos with 50X e 200X were obtained. The results regarding the marginal infiltration were statistically tested. Thus allowing the following conclusions: when isolated and tested (without the matrix), the cement MBP-c presented the smallest coefficient of marginal leakage, followed by the Super-EBA. There was a statistical significance between those and the cements ProRoot – MTA e MTA – Angelus (p<0,001). In the presence of the Plaster of Paris matrix, the cement MBP-c presented the smallest levels of marginal leakage, having statistical significance between those and the cements ProRoot – MTA e MTA – Angelus (p<0,05); There was a significant statistical variation, in the marginal leakage of the cements due to the presence of the Plaster of Paris matrix to the Super-EBA and to MBP-c (p<0,05). The utilization of the Plaster of Paris matrix avoided the leakage of the sealing materials. A direct relationship could be found between the marginal adaptation and the material sealing capacity
5

Influ?ncia do selamento dentin?rio imediato na polimeriza??o de materiais de moldagem e na resist?ncia ? fratura de coroa em cer?mica

Ghiggi, Paula Cristine 14 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:22Z (GMT). No. of bitstreams: 1 448385.pdf: 890714 bytes, checksum: 62d158637f85cd4da3fefcd711a75370 (MD5) Previous issue date: 2013-03-14 / The first section of this study evaluated the interaction between resin materials used in the immediate dentin sealing (IDS) techniques and impression materials under two different techniques to reduce/eliminate the oxygen-inhibition layer. The occlusal dentin of 35 human molars was exposed and finished with 400 grit silicon carbide sandpaper. Teeth were randomly divided into 2 groups: group 1 impression with vinyl polysiloxane Express XT, group 2 impression with polyether Impregum. Groups 1 and 2 were divided into 14 subgroups: groups 1a e 2a: control groups; groups 1b e 2b: IDS with Clearfil SE Bond (CSE); groups 1c e 2c: IDS with CSE + additional polymerization with glycerine jelly; groups 1d e 2d: IDS with CSE + alcohol; groups 1e e 2e: IDS with CSE and Protect Liner F (PLF); groups 1f e 2f: IDS with CSE and PLF + additional polymerization with glycerin jelly; groups 1g e 2g: IDS with CSE and PLF + alcohol. Each tooth surface was photographed using a digital camera. The images saved were used to examine the presence of impression material left on the treated tooth surface. It was observed that IDS performed with CSE or with the PLF interacted with the Express XT and with the Impregum. The application of glycerine jelly and alcohol avoided the interaction of CSE with the Express XT and of the PLF with the Impregum; however, these treatments were not totally effective to avoid the interaction of CSE with the Impregum and of PLF with the Express XT. The second section of this study evaluate, in vitro, the thickness of the adhesive, low-viscosity microfilled resin, and resin cement on full crown preparations, and its effect on the fracture load of a reinforced all-ceramic crown. Sixty maxillary premolars received full crown preparation and were divided in 3 groups according to the material applied for the immediate dentin sealing: G1 control; G2 CSE Bond; G3 CSE Bond + PLF. After taking the impression with polyvinyl siloxane, the preparations were temporized with acrylic resin crowns. IPS Empress 2 restorations were fabricated, and cemented to the preparations with Panavia F. Ten specimens of each group were submitted to fracture load testing, and the other 10 specimens were sectioned buccolingually, and the thicknesses of Panavia F, CSE Bond and PLF were measured in 10 different positions using a microscope. According to ANOVA and Tukey s test, the fracture load of group 3 (1300 N) was statistically higher than group 1 (1001 N) (p<0.01). Group 2 (1189 N) was not statistically different from groups 1 and 3. The higher thickness of the CSE Bond was obtained in the concave part of the preparation. The PLF presented a more uniform range of values at different positions. The thickness of Panavia F was higher in the occlusal portion of the preparation. The film thickness formed by CSE Bond and PLF increased the fracture load of the IPS Empress 2 ceramic crown. / A primeira etapa deste estudo avaliou, in vitro, a intera??o entre materiais resinosos utilizados na t?cnica do selamento dentin?rio imediato (SDI) e materiais de moldagens associado a duas t?cnicas para reduzir/eliminar a camada inibida de oxig?nio. A dentina oclusal de 35 terceiros molares humanos foi exposta, seguido de acabamento com lixa de carbeto de sil?cio de granula??o 400. Os dentes foram divididos aleatoriamente em 2 grupos: grupo 1- moldagem com silicone por adi??o Express XT; grupo 2 moldagem com o poli?ter Impregum. Os grupos 1 e 2 foram divididos em 14 subgrupos: grupo 1a e 2a: controle; grupos 1b e 2b: SDI com Clearfil SE Bond (CSE); grupos 1c e 2c: SDI with CSE + polimeriza??o adicional com gel a base de glicerina; grupos 1d e 2d: SDI com CSE + ?lcool; grupos 1e e 2e: SDI com CSE e Protect Liner F (PLF); grupos 1f e 2f: SDI com CSE e PLF + polimeriza??o adicional com gel a base de glicerina; grupos 1g e 2g: SDI com CSE e PLF + ?lcool. Cada superf?cie dent?ria foi fotografada com uma c?mera digital. As imagens foram salvas e utilizadas para avaliar a presen?a de material de moldagem sobre a estrutura dent?ria. Por meio de uma an?lise qualitativa, observou-se que o SDI realizado com o CSE ou com PLF interagiram com o Express XT e com o Impregum. A aplica??o do gel a base de glicerina e do ?lcool impediram a intera??o do CSE com o Express XT e do PLF com o Impregum; no entanto, estes mesmos tratamentos n?o foram totalmente efetivos para o CSE com o Impregum e para o PLF com o Express XT. A segunda etapa deste estudo avaliou a espessura do sistema adesivo, resina de baixa viscosidade e cimento resinoso em preparos para coroas totais, e a influ?ncia na resist?ncia ? fratura de coroa total em cer?mica. Sessenta pr?-molares superiores receberam prepares para coroa total e foram divididos em 3 grupos de acordo com o material aplicado na t?cnica do SDI: grupo 1 controle; grupo 2 - CSE; G3 CSE + PLF. Ap?s moldagem com silicone por adi??o, os preparos receberam provis?rios confeccionados com resina acr?lica. As restaura??es cer?micas com IPS Empress 2 foram confeccionadas e cimentadas sobre os preparos com Panavia F. Dez amostras de cada grupo foram submetidos ao teste de resist?ncia ? fratura e 10 esp?cimes foram seccionados no sentido vest?bulo-lingual para avaliar a espessura do Panavia F, CSE e PLF em 10 posi??es diferentes com o aux?lio de um microsc?pio. De acordo com ANOVA e teste de Tukey, a carga de fratura do grupo 3 (1300 N) foi estatisticamente superior ao grupo 1 (1001 N) (p<0.01) e o grupo 2 (1189 N) n?o apresentou diferen?a estat?stica com os grupos 1 e 3. A maior espessura de pel?cula do CSE Bond foi obtida na parte c?ncava dos prepares. O PLF apresentou a espessura mais uniforme em diferentes posi??es. A espessura do Panavia F foi maior na face oclusal dos preparos. A espessura da pel?cula formada pelo CSE e PLF aumentou a resist?ncia ? fratura de coroas cer?micas confeccionadas com IPS Empress 2.
6

Avalia??o in vitro da rugosidade superficial e manuten??o dos selantes de superf?cies para resinas compostas submetidos ? escova??o

Bonatto, Fernanda 01 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:24Z (GMT). No. of bitstreams: 1 448373.pdf: 984719 bytes, checksum: e51e892e5e4e07ff9dd9d9321a1c3b79 (MD5) Previous issue date: 2013-03-01 / Objectives : 1) to evaluate the roughness of three surface sealants applied on a composite resin when subjected to simulated toothbrushing for different periods, 2) to evaluate, with the aid of scanning electron microscopy, the presence of surface sealants after simulated toothbrushing; 3) evaluating whether the type of dentifrice may shorten the life of the sealing surface. Materials and Methods : One hundred and eight bodies of the specimens were fabricated with resin Amelogen Plus, divided into 6 groups (n = 18) according to the type of surface sealant (Fortify (F), BisCover LV (B) and Permaseal (P)) and toothpaste (Colgate Total 12 Clean Mint (CT) and Colgate Total Professional Whitening 12 (PW)). The samples were subjected to brushing cycles, simulating periods of 6 months, 12 months, 18 months and 24 months. After each period, the samples had a surface roughness measured. An additional group of 48 samples was conducted for SEM analysis. The results were analyzed by ANOVA with three fixed factors (sealants, time and toothpaste) and Tukey's test (&#945; = 5%). Results : BisCover had the lowest average surface roughness (0.06 &#956;m) compared with sealants Fortify (0.09 &#956;m) and Permaseal (0.08 &#956;m), which were not statistically different. The Fortify on 12 months of brushing, had the highest average roughness (0.13 &#956;m). The average roughness for the dentifrice CT was lower (0.07 &#956;m), compared to the PW (0.08 &#956;m) and was statistically different. The roughness increased up to 12 months of simulated brushing (0.04 &#956;m, 0.08 &#956;m and 0.11 &#956;m), decreasing at the 18th month (0.08 &#956;m) up to 24 months of brushing (0.07 &#956;m). Conclusions : The sealant Fortify had the highest average roughness in 12 months of simulated toothbrushing, and the lowest roughness values were obtained by BisCover. Through SEM, it was observed that none of the seals used in the study was completely removed from the resin by 24 months of brushing. / Objetivos : 1) avaliar a rugosidade de tr?s selantes de superf?cie aplicados sobre uma resina composta quando submetidos ? escova??o simulada por diferentes per?odos; 2) avaliar, com aux?lio da microscopia eletr?nica de varredura, a presen?a dos selantes de superf?cie ap?s escova??o simulada; 3) avaliar se o tipo de dentifr?cio pode diminuir o tempo de vida ?til dos selantes de superf?cie. Materiais e M?todos : Cento e oito corpos-de-prova foram confeccionados com resina Amelogen Plus, divididos em 6 grupos (n=18) conforme o tipo de selante de superf?cie (Fortify (F), BisCover LV (B) e Permaseal (P)) e dentifr?cios (Colgate total 12 Clean Mint (CT) e Colgate total 12 Professional Whitening (PW)). As amostras foram submetidas a ciclos de escova??o, simulando per?odos de 6 meses, 12 meses, 18 meses e 24 meses. Ap?s cada per?odo, as amostras tiveram a rugosidade de superf?cie mensurada. Um grupo adicional de 48 amostras foi realizado para an?lise em M.E.V. Os resultados foram submetidos ao teste de ANOVA com tr?s fatores fixos (selantes, tempo e dentifr?cio) e de Tukey (&#945; = 5%). Resultados : BisCover apresentou a menor m?dia de rugosidade de superf?cie (0,06 &#956;m) quando comparado com os selantes Fortify (0,09 &#956;m) e Permaseal (0,08 &#956;m), os quais n?o foram estatisticamente diferentes entre si. O Fortify, em 12 meses de escova??o, apresentou a maior m?dia de rugosidade (0,13 &#956;m). A m?dia de rugosidade para o dentifr?cio CT foi menor (0,07 &#956;m) se comparado com o PW (0,08 &#956;m), sendo estatisticamente distintos. A rugosidade de superf?cie aumentou at? os 12 meses de escova??o simulada (0,04 &#956;m, 0,08 &#956;m e 0,11 &#956;m), diminuindo no 18? m?s (0,08 &#956;m) at? os 24 meses de escova??o (0,07 &#956;m). Conclus?es : o selante Fortify apresentou a maior m?dia de rugosidade em 12 meses de escova??o simulada, e os menores valores de rugosidade foram obtidos pelo BisCover. Atrav?s da M.E.V, observou-se que nenhum dos selantes utilizados no estudo foi removido completamente da resina at? os 24 meses de escova??o.

Page generated in 0.157 seconds