• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 1
  • 1
  • 1
  • Tagged with
  • 19
  • 19
  • 11
  • 11
  • 8
  • 8
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência da contaminação do campo operatório na resistência de união à dentina / Influence of the contamination of the operatory Field at dentin bonding strength

Mendonça, Ellen Cristina de Carvalho 03 August 2010 (has links)
Os estudos sobre contaminação apresentam difícil comparação devido a variedade dos delineamentos experimentais como o tipo de substrato testado, o momento na sequência do procedimento adesivo em que a contaminação acontece e a forma como essa contaminação é tratada de maneira a limpar este campo operatório. Assim, novos estudos fazem-se necessários para investigar com maior profundidade as condições já descritas na literatura e assim, obter um protocolo de conduta mais seguro para lidar com a contaminação. Esse estudo objetivou analisar,através de Microscopia Eletronica de Varredura (MEV), a interface adesiva de restaurações realizadas com sistema adesivo autocondicionante de dois passos (Clearfill SE Bond Kuraray), contaminadas por sangue em dois momentos diferentes, recebendo essa contaminaçao dois tratamento distintos. Para tanto foram selecionados 15 molares humanos que foram divididos em 5 grupos experimentais (n=3): G1 controle (sem contaminaçao); G2 contaminação antes do primer, com tratamento de lavagem e secagem; G3 contaminação antes do primer com tratamento de secagem; G4 contaminação após bond fotopolimerizado com tratamento de lavagem e secagem; G5 contaminação após bond fotopolimerizado com tratamento de secagem. Os dentes foram submetidos ao corte do terço oclusal da coroa para obtenção de superfície dentinária plana. Essa superfície foi regularizada com lixas SiC e a camada de esfregaço padronizada foi obtida com lixa SiC #600 por 1 min. Os espécimes foram contaminados, de acordo com os grupos experimentais, com sangue obtido de um único doador o próprio autor armazenado em tubos Vacuette® com heparina sódica e utilizado em até 7 dias. Então foram restaurados com uma camada de resina flow (Filtek Z-350 Flow 3M-ESPE) e duas camadas de resina microhibrida (Filtek Z-350 3MESPE). Após a construção dos espécimes, estes foram seccionados ao meio e passaram por preparo para análise em MEV. Os resultados obtidos foram descritos de duas formas: Análise Morfológica: onde foram observadas alterações na formação da camada híbrida (CH) em grupos com a presença do contaminante, e Análise Morfométrica, que foi analisada estatisticamente, e pode-se constatar uma relação entre a presença do contaminante e a diminuição do tamanho de tags em m, quando comparados ao grupo controle (p 0,05). Adicionalmente, foi observado que o tratamento de lavagem com água não foi suficiente para reestabelecer a formação de camada híbrida semelhante a observada no grupo controle. / Studies on contamination are difficult to compare due to the variety of experimental designs as the type of substrate, the time when contamination takes place during the adhesive procedure and how this contamination is treated in order to clean the operatory field. Thus, further studies are needed to investigate more thoroughly the conditions described in the literature and obtain a protocol to deal with contamination. This study aimed to observe, by scanning electron microscopy (SEM), the interface of adhesive restorations performed with a two-stepself-etching adhesive system (Clearfill SE Bond - Kuraray), contaminated with blood at two different times, receiving two different treatment to the contamination . Therefore, 15 selected human molars were divided into five experimental groups (n = 3): G1 - control (no contamination), G2 - contamination before primer, and rinsing and drying treatment, G3 - contamination before priming treatment, thendrying; G4 - contamination after light curing bond, rinsing and drying treatment; G5 - after light curing bond and drying. The teeth were then seccioned in order to obtain a flat dentin surface. This surface was regularized with SiC sandpaper and a standardized smear layer was obtained with SiC sandpaper # 600 for 1 min. The specimens were subsequently contaminated, according to the experimental groups, with blood obtained from a single donor - the author stored inVacuette ® tubes with sodicheparin and used within 7 days. They were restored with a layer of flowable composite (Filtek Z-350 Flow - 3M-ESPE) and two layers of microhybridresin (Filtek Z-350 - 3M-ESPE). After construction, the specimenswere divided in two, exposing the center of restorationand passed through preparation for SEM analysis. The results were described in two ways: Morphological Analysis where changes were observed in hybrid layer (HL) formation of groups in the presence of the contaminant, and Morphometric Analysis, which was analyzed statistically andaassociation between presence of the contaminant and a decreasing size of tags was found when compared to the control group (p 0.05). Additionally, it was observed that treatment of washing with water was not sufficient to restore the formation of hybrid layer similar to that observed in the control group.
12

EFEITO DE DIFERENTES PROTOCOLOS DE APLICAÇÃO DE ADESIVOS UNIVERSAIS NAS PROPRIEDADES E LONGEVIDADE DA UNIÃO À DENTINA / Effect of different universal adhesive application protocols on the properties and longevity of bond to dentin

Pérez, Miguel Angel Muñoz 07 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1 Tese Miguel Munoz Doutorado Odontologia 2014.pdf: 3888005 bytes, checksum: 9a25e76295a44d9cdb11d6afb38c9041 (MD5) Previous issue date: 2014-02-07 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The aim of the present study was to make an in vitro evaluation of the properties and stability of the bond to dentin of new universal adhesive systems applied according to the etch-and-rinse (ER) and self-etching (SE) adhesive strategies. The specific objectives for each of the three studies were: To evaluate the microtensile bond strength (RU), nanoleakage (NI) and degree of conversion (DC) in the time intervals of 24 h (Experiment 1) and six months (Experiment 2) of the universal adhesive systems applied in accordance with the manufacturers’ recommendations for strategies ER and SE; and the effect of an additional hydrophobic layer (Experiment 3, in the immediate time interval) on these same properties. The occlusal surfaces of 140 third molars were flattened until dentin was obtained, and then the teeth were randomly allocated to 28 groups (n=5). In Experiments 1 and 2, 40 teeth were divided into eight groups according to the adhesive used (Peak Universal [Pk], Scotchbond Universal [Sc], Allbond Universal [Al]) and adhesive strategy (ER and SE), with the ER adhesive system Adper Single Bond 2 (SB) and self-etching Clearfil SE Bond (CSE) used as controls. For Experiment 3, 60 teeth were divided into 12 groups according to the adhesive (Sc, Al, G-Bond Plus [Gbp]), adhesive strategy (ER and SE) and with or without hydrophobic layer (Heliobond, HE). After application of the variables adhesives and restorative procedure, the teeth were stored in distilled water (37oC/24 h) and cut to obtain dentin-resin sticks (0.8 mm2 cross-section) which were submitted to the RU and NI tests in the following time intervals: immediate (Experiments 1 and 3) and six months (Experiment 2); and analysis of DC in the immediate time interval. The data of Experiment 1 were submitted to one-way analysis of variance (Adhesive Strategy) and those of Experiments 2 and 3, to twoway analysis of variance (Adhesive strategy vs. Time intervals; and Adhesive strategy vs. Hydrophobic layer) respectively. The analyses were complemented by the Tukey Test (α=0.05). The RU results obtained in Experiment 1 demonstrated that only PkEr and PkSe were similar to the respective control groups (p>0.05); that the other universal materials resulted in lower RU means than those of their controls ER and SE (p<0.05) and that AlSe presented the lowest mean RU values (p<0.05). For NI, the Groups ScEr, ScSe, AlSe, and AlEr presented low levels of NI similar to those of the control groups (p<0.05). For DC, only Group ScSe demonstrated low DC when compared with the other materials (p<0.05). According to the results of Experiment 2, the systems Pk and AlEr presented a reduction in RU (p<0.05) and only Pk underwent significant degradation (NI) after six months (p<0.05). According to Experiment 3, Al and Gbp obtained higher RU results with the ER strategy (p<0.05); the use of HE increased the RU only in strategy SE (p<0.05); a low level of NI was observed only in Groups Sc and Al with the CON+HE strategy and in Group Gbp with SE+HE; Groups Sc and Gbp presented a high DC when used with the ER strategy, which was increased with the application of HE (p<0.05). The DC if Al was similar under all the conditions. From the three experiments of which this study was composed, it could be concluded that: 1) the universal adhesives presented a 13 material-dependent behavior in both strategies (ER and SE) and were inferior, in at least one of the properties evaluated (RU, Nl or DC), when compared with the control adhesives (CSE and SB); 2) In general, after six months the adhesives SE maintained the most stable RU and NI values, which appears to be related mainly to their capacity to form a chemical bond to dental substrate; 3) The use of a hydrophobic layer in strategy SE was able to increase the RU and DC of universal adhesives and the reduction in NI was more dependent on the composition of the adhesive than on the adhesive strategy. / O objetivo do presente trabalho foi avaliar in vitro as propriedades e longevidade da união à dentina dos novos sistemas adesivos universais aplicados segundo as estratégias adesivas convencional (CON) e autocondicionante (AC). Os objetivos específicos para cada um dos três estudos foram: avaliar a resistência de união à microtração (RU), a nanoinfiltração (NI) e o grau de conversão (GC) no tempo imediato - 24 h - experimento 1) e seis meses (Experimento 2) dos sistemas adesivos universais para as estratégias CON e AC; e o efeito de uma camada hidrofóbica adicional (Experimento 3, no tempo imediato) sobre essas mesmas propriedades. Cento e quarenta terceiros molares foram planificados na face oclusal até se obter dentina e alocados aleatoriamente em 28 grupos (n=5). Nos Experimentos 1 e 2, 40 dentes foram divididos em oito grupos de acordo com o adesivo (Peak Universal [Pk], Scotchbond Universal [Sc], Allbond Universal [Al]) e estratégia adesiva (CON e AC) tendo como controle, o sistema adesivo convencional Adper Single Bond 2 (SB) e o autocondicionante Clearfil SE Bond (CSE). Para o Experimento 3, 60 dentes foram divididos em 12 grupos de acordo com o adesivo (Sc, Al, G-Bond Plus [Gbp]), estratégia adesiva (CON e AC) e com a presença ou não de camada hidrofóbica (Heliobond, HE). Após aplicação das variáveis adesivas e do procedimento restaurador, os dentes foram armazenados em água destilada (37oC/24 h) e cortados para obter palitos de dentina-resina (0,8 mm2 de secção transversal) sendo submetidos aos teste de RU e NI nos tempos imediato (Experimentos 1 e 3) e também seis meses (Experimento 2); e análise de GC no tempo imediato. Os dados do Experimento 1 foram submetidos à análise de variância de um fator (Estratégia Adesiva) e os dos Experimentos 2 e 3, à de dois fatores (Estratégia adesiva versus Tempos de análise; e Estratégia adesiva versus Camada hidrofóbica), respectivamente. As análises foram complementadas pelo teste de Tukey (α=0,05). Os resultados de RU obtidos no Experimento 1 demonstraram que apenas PkCon e PkAc foram similares aos respectivos grupos controle (p>0,05), que os outros materiais universais resultaram em médias de RU inferiores aos seus controles CON e AC (p<0,05) e que AlAc apresentou as médias mais baixas de RU (p<0,05). Para NI, ScCon, ScAc, AlAc, e AlCon apresentaram baixos níveis de NI similares aos grupos controle (p<0,05). Para GC, unicamente ScAc demostrou baixo GC, quando comparado com os outros materiais (p<0.05). Segundo os resultados do Experimento 2, os sistemas Pk e AlCon apresentaram diminuição da RU (p<0,05) e apenas Pk teve degradação significativa (NI) após seis meses (p<0,05). De acordo com o Experimento 3, Al e Gbp obtiveram maiores resultados de RU na estratégia CON (p<0,05); o uso de HE aumentou a RU unicamente na estratégia AC (p<0,05); baixa NI foi observada somente em Sc e Al na estratégia CON+HE e em Gbp em AC+HE; Sc e Gbp apresentaram alto GC quando usados em estratégia CON, que foi aumentado com a aplicação de HE (p<0,05). O GC de Al foi similar em todas as condições. A partir dos três experimentos que compõem o presente trabalho, pôdese concluir que: 1) os adesivos universais apresentaram um comportamento 11 dependente do material em ambas estratégias (CON e AC) e foram inferiores, pelo menos em uma das propriedades avaliadas (RU, Nl ou GC), quando comparados aos adesivos controle (CSE e SB); 2) Em geral, após seis meses os adesivos AC mantém mais estáveis os valores de RU e NI, o que parece estar relacionado principalmente à sua capacidade de união química ao substrato dental; 3) A utilização de uma camada hidrofóbica na estratégia AC pôde aumentar a RU e o GC de adesivos universais e a redução da NI foi mais dependente da composição do adesivo do que da estratégia adesiva.
13

Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentin

Menegatti, Giovanna Emann Tavares 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
14

Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentin

Giovanna Emann Tavares Menegatti 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
15

Influência da contaminação do campo operatório na resistência de união à dentina / Influence of the contamination of the operatory Field at dentin bonding strength

Ellen Cristina de Carvalho Mendonça 03 August 2010 (has links)
Os estudos sobre contaminação apresentam difícil comparação devido a variedade dos delineamentos experimentais como o tipo de substrato testado, o momento na sequência do procedimento adesivo em que a contaminação acontece e a forma como essa contaminação é tratada de maneira a limpar este campo operatório. Assim, novos estudos fazem-se necessários para investigar com maior profundidade as condições já descritas na literatura e assim, obter um protocolo de conduta mais seguro para lidar com a contaminação. Esse estudo objetivou analisar,através de Microscopia Eletronica de Varredura (MEV), a interface adesiva de restaurações realizadas com sistema adesivo autocondicionante de dois passos (Clearfill SE Bond Kuraray), contaminadas por sangue em dois momentos diferentes, recebendo essa contaminaçao dois tratamento distintos. Para tanto foram selecionados 15 molares humanos que foram divididos em 5 grupos experimentais (n=3): G1 controle (sem contaminaçao); G2 contaminação antes do primer, com tratamento de lavagem e secagem; G3 contaminação antes do primer com tratamento de secagem; G4 contaminação após bond fotopolimerizado com tratamento de lavagem e secagem; G5 contaminação após bond fotopolimerizado com tratamento de secagem. Os dentes foram submetidos ao corte do terço oclusal da coroa para obtenção de superfície dentinária plana. Essa superfície foi regularizada com lixas SiC e a camada de esfregaço padronizada foi obtida com lixa SiC #600 por 1 min. Os espécimes foram contaminados, de acordo com os grupos experimentais, com sangue obtido de um único doador o próprio autor armazenado em tubos Vacuette® com heparina sódica e utilizado em até 7 dias. Então foram restaurados com uma camada de resina flow (Filtek Z-350 Flow 3M-ESPE) e duas camadas de resina microhibrida (Filtek Z-350 3MESPE). Após a construção dos espécimes, estes foram seccionados ao meio e passaram por preparo para análise em MEV. Os resultados obtidos foram descritos de duas formas: Análise Morfológica: onde foram observadas alterações na formação da camada híbrida (CH) em grupos com a presença do contaminante, e Análise Morfométrica, que foi analisada estatisticamente, e pode-se constatar uma relação entre a presença do contaminante e a diminuição do tamanho de tags em m, quando comparados ao grupo controle (p 0,05). Adicionalmente, foi observado que o tratamento de lavagem com água não foi suficiente para reestabelecer a formação de camada híbrida semelhante a observada no grupo controle. / Studies on contamination are difficult to compare due to the variety of experimental designs as the type of substrate, the time when contamination takes place during the adhesive procedure and how this contamination is treated in order to clean the operatory field. Thus, further studies are needed to investigate more thoroughly the conditions described in the literature and obtain a protocol to deal with contamination. This study aimed to observe, by scanning electron microscopy (SEM), the interface of adhesive restorations performed with a two-stepself-etching adhesive system (Clearfill SE Bond - Kuraray), contaminated with blood at two different times, receiving two different treatment to the contamination . Therefore, 15 selected human molars were divided into five experimental groups (n = 3): G1 - control (no contamination), G2 - contamination before primer, and rinsing and drying treatment, G3 - contamination before priming treatment, thendrying; G4 - contamination after light curing bond, rinsing and drying treatment; G5 - after light curing bond and drying. The teeth were then seccioned in order to obtain a flat dentin surface. This surface was regularized with SiC sandpaper and a standardized smear layer was obtained with SiC sandpaper # 600 for 1 min. The specimens were subsequently contaminated, according to the experimental groups, with blood obtained from a single donor - the author stored inVacuette ® tubes with sodicheparin and used within 7 days. They were restored with a layer of flowable composite (Filtek Z-350 Flow - 3M-ESPE) and two layers of microhybridresin (Filtek Z-350 - 3M-ESPE). After construction, the specimenswere divided in two, exposing the center of restorationand passed through preparation for SEM analysis. The results were described in two ways: Morphological Analysis where changes were observed in hybrid layer (HL) formation of groups in the presence of the contaminant, and Morphometric Analysis, which was analyzed statistically andaassociation between presence of the contaminant and a decreasing size of tags was found when compared to the control group (p 0.05). Additionally, it was observed that treatment of washing with water was not sufficient to restore the formation of hybrid layer similar to that observed in the control group.
16

A influência da água na composição de primers autocondicionantes experimentais / Influence of the water concentration in an experimental self-etching primer on the bond strength to dentin

Lima, Giana da Silveira 21 December 2007 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 1 Dissertacao_giana_da_silveira_lima.pdf: 1493174 bytes, checksum: 68e4c67538ad95eba022c0a0e790d4b8 (MD5) Previous issue date: 2007-12-21 / To investigate the influence of different water concentrations in self-etching primers solvents on microtensile bond strength (μTBS) of an experimental adhesive system. Five experimental self-etching primers with 0, 5, 10, 20 and 40 water concentration (wt %) in solvent, were synthesized. Clearfil SE Bond (CSEB) was used as commercial adhesive. Sixty bovine incisive were randomize separated in six groups (n=20). Vestibular enamel was removed to expose the superficial coronal dentin, this surface was polished wet to create a standardized smear layer. After rinsing, water was removed, leaving the surface visibly dried. The dentin surfaces were etched with primer and air-dried, after coating adhesive resin was applied and photo-activated, following the composite resin restoration was accomplished. After storage for 24 hours, the specimens were sectioned with a refrigerated diamond saw at low-speed. Microtensile bond strength were measured and data were analyzed by one-way ANOVA/Tukey s test (α=0.05). Analysis of variance showed that primer composition was a significant factor for bond strength. There was not difference on bond strength of the primers with water concentration: 40% (53.9 ± 12.7 MPa), 20% (51.1 ± 11.5 MPa) and 10% (47.5 ± 11.4 MPa) and CSEB (52.44 ± 13.27 MPa). The group with 5% (38.6 ± 12.9 MPa) and 0% (31.5 ± 7.5 MPa), present similar bond strength amongst themselves but statistically smaller that the other groups. The water concentration, present in the primer solvent, exercise significant influence on the bond strength of this experimental self-etching adhesive system / Este estudo avaliou a influência de diferentes concentrações de água no solvente de um primer autocondicionante de um sistema adesivo dentinário experimental. Foram formulados cinco primers experimentais com diferentes concentrações, 0; 5; 10; 20; 40%, de água em massa e Clearfil SE Bond (CSEB) foi utilizado como referência comercial. Foram utilizados 60 incisivos bovinos, distribuídos aleatoriamente entre 6 grupos (n= 20). Na face vestibular dos dentes foi realizado desgaste com lixas até a exposição de dentina com lixa d água 600. O primer foi aplicado sobre a dentina previamente seca com papel absorvente, sendo aplicado jato de ar e em seguida o adesivo foi aplicado e foto-ativado com aparelho fotopolimerizador LED SDI Radii®. A restauração foi confeccionada utilizando 2 incrementos, fotoativados de acordo com as recomendações do fabricante. Após armazenagem por 24 horas em água destilada à 37°C, os dentes foram seccionados em cortadeira de precisão e a resistência de união mensurada, através de ensaio de microtração em uma máquina de ensaios mecânicos. Análise de Variância segundo um critério e teste complementar de Tukey foram utilizados na análise estatística (α=5%). Não houve diferença na resistência de união de P40 (53,9 ±12,7 MPa) P20 (51,1 ±11,5 MPa) e P10 (47,5 ±11,4 MPa) e CB (52,44 ±13,27 MPa). Os grupos P5 (38,6 ±12,9 MPa) e P0 (31.5 ±7.5 MPa) não apresentaram diferença estatística entre si, mas seus valores de adesão dentinária foram menores que os demais grupos (p<0,05). A resistência de união dentinária do sistema adesivo experimental testado sofre influência da concentração de água presente no solvente do primer autocondicionante
17

Enamel conditioning effect on penetration and microleakage of glass ionemer-based sealants

Ahmed, Senan Raad January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / While most sealants available are resin-based, glass ionomer-based cements can be used as sealants, with the advantage of being more tolerant to moisture during placement and of releasing fluoride. The objective of this study was to evaluate the influence of different fissure conditioning techniques on penetration and microleakage of glass ionomer (GI) and resin-modified glass ionomer cements (RMGI) used as sealants. Clinically sound extracted human molars were distributed into nine experimental groups (n = 15 each). Group 1 (control) was sealed with resin-based sealant (Delton) following clinically accepted techniques. Groups 2 through 6 were sealed with RMGI (Vitremer) after having the fissure conditioned with either polyacrylic acid (RMGI-control), 35-percent H3PO4, low viscosity 35-percent H3PO4 with a surfactant, self-etch conditioner, or 35-percent H3PO4 followed by self-etch conditioner. Groups 7 through 9 were sealed with GI sealant (Fuji Triage) after having the fissures conditioned with either polyacrylic acid (GI-control), 35- percent H3PO4 or low viscosity 35-percent H3PO4 with a surfactant. After aging through thermocycling (2500 cycles), specimens were incubated in methylene blue for four hours and sectioned at multiple locations. Digital images were obtained using a digital stereomicroscope, and microleakage was determined by scoring the dye penetration along the enamel-sealant interface. The penetration of the material was determined by calculating the percentage of the total length of the fissure penetrated by the material. Results: The use of self etch-conditioner significantly increased RMGI penetration, while surface conditioning with 35-percent phosphoric acid with surfactant significantly decreased microleakage of GI. The resin-based sealant placed after 35-percent phosphoric acid surface conditioning showed the best penetration and the least level of microleakage. In conclusion, results from this study suggest that the placement of glass ionomer-based sealants can be enhanced by modifying current conditioning methods.
18

Analyse d'une interface adhérente dentine/titane en fonction de différents matériaux d'assemblage / Study of a dentin adhesive / titanium interface mediated by different resin luting cement

Schittly, Estelle 18 April 2016 (has links)
Le fil directeur durant cette période de recherche a été l’étude d’une interface dentine/titane assemblée par collage. L’objectif était d’optimiser et de simplifier des étapes du protocole d’assemblage, d’améliorer et d’étudier les performances de l’interface adhérente. Dans ce travail, les interfaces ont été testées in vitro par cisaillement.Cette étude a comporté trois volets :Le but de la première étude a été d’évaluer un assemblage par ciment verre ionomère (CVI), le Fuji Plus®, appliqué en association avec des adhésifs auto-mordançants sur la dentine. Trois des combinaisons « système auto-mordançant/Fuji Plus® » ont été appliquées et les résultats obtenus montrent des améliorations significatives entre 9% et 44% par rapport aux valeurs obtenues sur des éprouvettes de témoin.Le second volet expérimental a eu pour objectif de tester la compatibilité entre cinq systèmes adhésifs auto-mordançants (SAM) et deux composites d’assemblage (CA). Les SAM1 se sont révélés totalement incompatibles avec les CA chémopolymérisés ou duals. Inversement, les SAM2 étaient compatibles avec des CA chémopolymérisants ou duals. Une corrélation positive a été trouvée entre le pH des SAM ou les résines testées et les données de cisaillement.La dernière étude a été dédiée à l’évaluation de l'effet du stockage dans l’eau sur la résistance à la flexion (σf) et sur la résistance au cisaillement (RC) d’une interface dentine/titane assemblée par quatre résines adhésives auto-mordançantes (MRAM). Cette étude a montré que le stockage dans l'eau durant 60 jours a affecté négativement la résistance à la flexion de certains matériaux. L'adhésion dentine/titane offerte par Rely X® et G-Cem® était significativement plus élevée que celle de Maxcem® et SmartCem2®. / The aim of this work was to study a bonding dentin/titanium interface. The objective was to optimize and simplify the steps of the bonding protocol, improve and know well the performance of the adhesive interface. In this work, all interfaces have been tested in vitro by shearing.This study included three parts :The purpose of the first study was to evaluate an assemblage by glass ionomer cement (GIC), the Fuji plus®, applied in combination with self-etch bonding system on dentin. Three combinations "system self-etching / Fuji Plus®" were applied and the results obtained by test showed significant improvements from 9% to 44% higher than the values obtained on control specimens.The second experimental part was designed to test the compatibility between five self-etch bonding systems (SEBS) and two resin luting cements (RLC). Significant differences of bond strength in shear were observed according to both the curing mode of the RLC and the adhesive. The SEBS1 proved totally incompatible with chemical or dual cured RLC. Conversely, two-steps SEBS were compatible with RLC chemical/dual cured RLC. A positive correlation was found between the pH of the SEBS or the tested resins and the shear data.The latest study was devoted to evaluate the effect of the storage condition on flexural strength (σf) and shear bond strength (SBS) of a dentin/titanium interface assembled by four self-etch adhesive resin (SEARC). This study showed that the storage in water for 60 days has negatively affected the bending resistance of certain materials. The dentin/titanium adherence offered by Rely X® and G-Cem® was significantly higher than that of Maxcem® and SmartCem2®.
19

Caracterização da cinética de polimerização e reatividade de promotores de polimerização para aplicação em resinas fotoativadas à base de metracrilatos / Initiators of polymerization on self-etching primers: effect on microtensile bond strength and on morphological pattern of hybrid layer

Ely, Caroline 01 January 2011 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 1 Dissertacao_Caroline_Ely.pdf: 855676 bytes, checksum: 3b493898d992f4952a9932fd00c16707 (MD5) Previous issue date: 2011-01-01 / The aim of this project will be to investigate the influence of the addition of light and co-initiators in self-etching primers, in relation to microtensile bond strength (μTBS) and on morphological pattern of hybrid layer of an experimental adhesive system. An experimental self-etching primer will be formulated and on which will be added the initiators of polymerization, resulting in a total of 6 experimental groups: PCONTROL, PCQ, PQTX, PDPI, PBAR and PSUL. A coating adhesive resin compound by Bis-GMA, TEGDMA and HEMA will be formulated. For μTBS test, forty-eight bovine incisors will be randomized and allocate in the six groups. Vestibular enamel will be grounded to expose the superficial coronal dentin, which that will be polished wet to create a standardized smear layer with 600 grit silicon paper. After rinsing, water will be removed with a piece of absorbent paper, leaving the surface visibly dried. The prepared dentin surfaces will be etched with primer and air-dried, after coating adhesive resin will be applied and light activated. The composite resin will be inserted in two increments and will be light activated according to the manufacturer s recommendations. After storage for 24 hours, the specimens will be sectioned with a refrigerated diamond saw at lowspeed. After check normal distribuition and equal variances as assumptions to carry out parametric statistics data obtained on μTBS, will be submitted to two-way ANOVA (factor time and factor initiator of (polymerization) test to verify differences between means (p<0.05). Fractographic analysis will be performed using optical microscopy to describe failure patterns. The morphological pattern of hybrid layer will be examined by scanning electron microscopy (Shimadzu SSX550), after 24 hours and 2 years of storage, using 3 teeth for each experimental group. Teeth will be sectioned with a refrigerated diamond saw, in order to obtain 2 or 3 slices per tooth, with 2mm thickness. Restorative procedure will take place, following the same steps of sample preparation 9 for μTBS test. Then, samples will pass through a sequence of polishing with grit silicon paper and diamond pastes of different granulations. Between each stage of polishing, samples will be placed in one ultrasonic tank to complete removal of waste. After, will undertake the procedures of decalcification with solution of phosphoric acid 50%, deproteinization with sodium hypochlorite solution 2.5%, dehydration with silica at room temperature for 2 hours and coating with gold/palladium. Finally, images of hybrid layer will be observed in SEM, on 3000 and 5000 fold increas / O objetivo deste projeto será avaliar a influência da adição de iniciadores de polimerização em primer autocondicionante experimental, na resistência de união e no padrão morfológico da camada híbrida de sistemas adesivos. Será formulado um primer experimental modelo, ao qual serão adicionados fotoiniciadores e co-iniciadores, obtendo-se um total de 6 grupos experimentais: PCONTROLE, PCQ, PQTX, PDPI, PBAR e PSUL. Como adesivo de cobertura, será formulado um co-monômero constituído de Bis-GMA, TEGDMA e HEMA. Para o ensaio de resistência de união à microtração (RU) serão utilizados 48 incisivos bovinos, distribuídos aleatoriamente entre os grupos . Na face vestibular dos dentes será realizado desgaste até a exposição de dentina e, posteriormente, polimento com lixa de SiC granulação 600 para padronização da smear layer. O primer será aplicado vigorosamente sobre a dentina previamente seca com papel absorvente e após será realizada a volatilização do solvente com jato de ar. Em seguida o adesivo de cobertura será aplicado e fotoativado com um aparelho fotopolimerizador de lâmpada halógena. A restauração será confeccionada em incrementos de compósito restaurador, fotoativados de acordo com as recomendações do fabricante. Após armazenagem por 24h em água destilada a 37°C, os dentes serão seccionados em cortadeira de precisão a fim de obterem-se palitos de aproximadamente 0,5mm2 de área de secção transversal. A RU em dentina será avaliada após 24h, 1 e 2 anos de armazenagem em água destilada. Os dados obtidos serão avaliados quanto à normalidade e igualdade de variâncias como condição para utilização de análise estatística paramétrica Preenchendo os requisitos anteriores será aplicada Análise de variância segundo dois critérios (fator tempo e fator iniciador de polimerização), e teste complementar de Tukey para detectar diferenças entre médias (α=5%). Os corpos de prova fraturados a partir do ensaio de microtração serão avaliados por microscopia óptica e classificados quanto ao modo de fratura em adesiva, 7 coesiva ou mista. A análise do padrão morfológico da camada híbrida será realizada por microscopia eletrônica de varredura MEV (SSX-550, Shimadzu), após 24 horas e 2 anos de armazenagem, utilizando-se 3 dentes para cada grupo experimental. Os dentes serão seccionados em cortadeira de precisão a fim de obter-se 2 ou 3 fatias por dente, com 2,0 mm de espessura cada uma. Será realizado então o procedimento restaurador, seguindo os mesmos passos utilizados para avaliar a RU. A seguir, as amostras passarão pelo protocolo de polimento com a seqüência de lixas de SiC e, em seguida, com discos de feltro e suspensões diamantadas, em granulações decrescentes.. Após, serão realizados os procedimentos de descalcificação com solução de ácido fosfórico 50% por 5 segundos, desproteinização com solução de hipoclorito de sódio 2,5% por 10 minutos, desidratação com sílica em temperatura ambiente e metalização. Por fim, serão obtidas fotomicrografias da camada híbrida em aumento de 3000 e 5000 vezes, através de Microscopia Eletrônica de Varrredura

Page generated in 0.0338 seconds