1 |
Electromagnetic wave propagation in anisotropic uniaxial slab waveguideIskandarani, Saad S. January 1989 (has links)
No description available.
|
2 |
Application of continuous radiation modes to the study of offset slab waveguidesLu, Shih-Min 30 August 2011 (has links)
In this thesis, we study the scattering problem of a vertically offset dielectric slab waveguide, using continuous radiation modes. The calculation of radiation modes of an arbitrarily layered waveguide has been thoroughly investigated in the literature. Most approaches were based on launching two incident waves: one from above and one from below, resulting in two transmitted waves and two reflected waves. Radiation modes were obtained by algebraic adjustments of each incident wave¡¦s amplitude and phase. These radiation modes formed standing waves in both the substrates and superstrates. This implies that walls are located an infinite distance far from the first and the last interfaces. In addition to physical conflicts of simultaneous existence of the incident wave and the walls, the derivation details are complicated and non-intuitive. In our thesis, with a given propagation constant for an arbitrarily layered dielectric waveguide, we propose an intuitive method to obtain two independent radiation mode solutions. We also construct a specific procedure to orthogonalize and normalize these two radiation modes.
The second part of this thesis is focused on applying these radiation modes into a customized coupled transverse mode integral equation formulation (CTMIE), to the study of vertically offset slab waveguides. CTMIE requires two artificial boundaries placed in the substrate and superstrate. We choose to compute discretized radiation modes with the periodic boundary conditions. Under these circumstances, modes correspond to different spatial frequencies and thereby do not inter-couple. This means the matrix of the overlap integral between these two groups of modes (slightly vertically shifted) are block-diagonally dominated. The off-diagonal elements are two orders of magnitude smaller than the diagonal ones. As a result, when the two artificial boundaries are pushed towards infinity in the CTMIE formulation, we may obtain an exact inverse of the Greene¡¦s matrix without relying on numerical inversion.
|
3 |
Solutions et matériaux nouveaux pour guide d'onde Térahertz / Novel solutions and materials for Terahertz wave guidingMalek Abadi, Seyed Ali January 2014 (has links)
Dans cette thèse, une étude approfondie sur des matériaux et des solutions pratiques est réalisée afin de répondre aux difficultés rencontrées dans la propagation des ondes à des fréquences térahertz (THz). Deux matériaux ont été identifiés comme étant prometteur: le graphène et le silicium à haute résistivité (HR-Si). Une première solution, basée sur des guides d’ondes à plaques parallèles (parallel plate waveguide-PPWG) avec des conditions de fermetures conducteur parfait (perfect electric conductor-PEC) -- graphène et graphène -- graphène a été analysée dans un premier temps. En considérant l'excitation du graphène par un champ électrique seulement, puis par un champ électromagnétique statique, les équations de Maxwell ont été résolues sous ces deux conditions et les constantes de propagations des différents modes ont été extraites. La démonstration de l'existence d'un mode propagatif hybride à l'intérieur du guide est faite dès que le graphène est excité par un champ magnétique. De plus, il est montré que l'intensité de chaque type de modes, transverse électrique (TE) ou transverse magnétique (TM), peut être ajustée suivant les champs d'excitation du graphène. Bien que le guide à plaques parallèles utilisant du graphène permette d'avoir des propriétés agiles, soit le contrôle des modes selon l'excitation du graphène, il n'en reste pas moins vrai que la faible conductivité intrinsèque au graphène conduit à un problème d'atténuation importante de l'onde. De plus, la difficulté d'obtenir des couches de graphène de taille adéquate entrave le développement de composants et de circuits fonctionnels, utilisables et à un coût raisonnable. La thèse porte ensuite sur l’étude du silicium haute résistivité pour guider des ondes aux fréquences térahertz. Tout d’abord, un guide composé d'une couche de HR-Si, de section rectangulaire dont la largeur est très grande par rapport à la hauteur, est caractérisé en utilisant un système de spectroscopie dans le domaine du temps, système permettant d'obtenir un large spectre de fréquences dans le domaine THz. Par cette caractérisation, les faibles pertes et la faible dispersion du HR-Si est démontrée. Cependant, il est aussi démontré que la géométrie du guide n'est pas optimale, conduisant à des pertes par dispersion de l'onde à l'intérieur du guide au fur et à mesure de sa propagation. Aussi, pour éviter cette dispersion, un confinement de l'onde est proposé en réduisant la largeur de la couche HR-Si pour la rendre de l'ordre de la hauteur (confinement en x et y, propagation en z) conduisant ainsi à la réalisation d'un guide d’ondes diélectrique en ruban (dielectric ribbon waveguide-DRW). Une analyse approfondie de la propagation d'une telle structure a conduit à concevoir un guide à faibles pertes d'une part, mais également à propagation monomode sur une large bande de fréquence. Une méthode de fabrication simple a été développée pour réaliser ce type de guide et un banc de mesure spécifique a été mis en place pour caractériser ce nouveau guide. Les mesures réalisées utilisent un analyseur de réseaux vectoriel (un PNA-X d'Agilent) auquel est branché deux têtes de mesure de la compagnie Virginia Diode Inc's (VDI) pour obtenir les bandes de fréquences désirées. Les sorties sont alors en guide rectangulaire standard, soit WR-8, soit WR-5 selon la plage de fréquence visée. Les résultats des mesures se comparent très bien avec les simulations réalisées avec un logiciel utilisant la méthode des éléments finis en trois dimensions (HFSS de la compagnie ANSYS) permettant d'obtenir les paramètres de la matrice de diffraction (S) mesurée par l'analyseur de réseau vectoriel. Finalement, dans le chapitre 6, un filtre passe-bande est développé comme preuve de concept pour l'utilisation du guide DRW utilisant le matériau HR-Si. Outre les faibles pertes et la propagation monomode d'un tel guide DRW, il est aussi montré dans cette thèse la facilité du processus de fabrication, le faible coût de ce procédé ainsi que la possibilité d'intégration avec d'autres composants passifs et actifs. Avec toutes ces caractéristiques très intéressantes sur différents plans, le guide DRW en HR-Si apparaît comme une solution très compétitive pour devenir un standard dans la bande de fréquence des THz.
|
4 |
Theory, Design, and Fabrication of Diffractive Grating Coupler for Slab WaveguideHarper, Kevin Randolph 18 September 2003 (has links) (PDF)
This thesis presents the theory design and fabrication of a diffractive grating coupler. The first part of the design process is to choose the period of the grating coupler based on the desired coupling angle. The second part of the design process is to choose the geometry of the grating that gives maximum coupling efficiency based on rigorous analyses.
The diffraction gratings are fabricated by recording the interference between two waves in photoresist. The waveguide is fabricated from silicon nitride that is deposited by chemical vapor deposition. The diffraction grating recording assembly is described along with the grating coupler fabrication process. A grating coupler is fabricated with an input coupling efficiency of 15% at a coupling angle of 22.9°. The results also show that the light is being coupled into the nitride waveguide indirectly. The light is coupled first into a photoresist slab and then into the nitride waveguide through modal coupling and scattering. An analysis of the structure explains the coupling, and rigorous analyses are given to show that the measured results are in accordance with theory.
|
5 |
Polymer integrated Young interferometers for label-free biosensing applicationsWang, M. (Meng) 13 November 2012 (has links)
Abstract
Integrated optical (IO) sensor allowing sensitive, label-free, real-time and multi-parameter monitoring of bio-molecular interactions are conventionally fabricated with inorganic dielectrics inherited from CMOS manufacturing technology. Polymers as complement materials to inorganic dielectrics are becoming to have an increasing market share for IO circuits in optical communications networks owing to its good optical properties, versatile processibility and low cost. This work aims at developing disposable low-cost biosensors based mainly on polymeric materials, with a performance comparable to inorganic-dielectric based IO biosensors.
This thesis describes the development of polymer IO biosensors based on the Young interferometer (YI) transducer platform for ambient noise compensation and a complete periodic intensity fringe pattern. Three different waveguide configurations were utilized, taking into consideration operational simplicity, fabrication simplicity and enhanced sensitivity. Among the developed polymer biosensors, an unconventional interferometer structure: a vertically placed dual-slab waveguide interferometer and an inverted rib waveguide configuration were employed. To enhance the sensitivity of the waveguides, deposition of Ta2O5 high index coating was performed on the rib waveguide configuration. Along with the development of polymer biosensors based on the inverted-rib waveguide configuration, a fabrication process was also developed featuring UV-imprinting and spin coating. The simple two-step fabrication process demonstrated using a polymer mold is potentially transferable to the roll-to-roll manufacture process.
Calibration of the developed sensors was performed by homogeneous refractive index (RI) sensing with glucose de-ionized water solutions. By investigating an antibody – antigen binding interaction involving C-reactive protein and its conjugates, this thesis confirmed the applicability of the developed sensors to specific molecule detection. Moreover, to establish the influence of water molecular absorption on measurement stability, an evaluation was carried out on the polymeric waveguide. Finally, the thesis presented a comparison between the developed sensors, exploring their sensitivities, stabilities, limits of detection (LODs) and other aspects related to operation and fabrication. The results indicated that the Ta2O5-coated polymer waveguide sensor had a high sensing capability. In homogeneous RI sensing, the achieved detection limits were 9×10-7 RIU (refractive index unit), i.e., three times the noise level, and 270 fg/mm2 for surface mass density. / Tiivistelmä
Integroidulla optiikalla toteutetut anturit mahdollistavat biomolekulaarisen vuorovaikutuksen tutkimisen käyttäen herkkiä moniparametrisia ja merkkiaineettomia menetelmiä. Näiden bioantureiden valmistukseen käytetään tavallisesti CMOS-teknologian piiristä tuttuja epäorgaanisia puolijohteita ja eristemateriaaleja. Viime aikoina on kuitenkin polymeeristen materiaalien käyttöä integroidussa optiikassa tutkittu merkittävästi johtuen polymeerien hyvistä optisista ominaisuuksista, monipuolisesta työstettävyydestä ja edullisista kustannuksista. Tämän työn tarkoituksena on kehittää edullisia, kertakäyttöisiä, pääasiallisesti polymeerisistä materiaaleista valmistettuja bioantureita, jotka vastaavat suorituskyvyltään epäorgaanisista materiaaleista valmistettuja integroidun optiikan antureita.
Tässä työssä kehitetyt polymeeriset integroidun optiikan bioanturit perustuvat Youngin interferometriin mahdollistaen ympäristökohinan kompensoinnin ja ne tuottavat pintavuorovaikutusten tutkimiseen jaksoittaisen interferenssikuvion. Työssä hyödynnettiin kolmea erilaista valokanavarakennetta huomioiden niiden käytön helppous, valmistuksen yksinkertaisuus ja mittausherkkyys. Yksi kehitetyistä polymeerisistä bioantureista koostui päällekkäisistä kerrostetuista polymeerikerroksista. Toisen tutkitun rakenteen toiminta puolestaan perustui käänteiseen harjannevalokanavaan. Mittausherkkyyttä parannettiin pinnoittamalla polymeerirakenne Ta2O5-pinnoitteella. Näin muodostui kerrostettu komposiittivalokanava, joka oli tässä työssä tutkittu kolmas sensorirakenne. Itse bioanturien lisäksi kehitettiin myös valmistusprosessi, jossa hyödynnettiin UV-painatusta ja nestefaasipinnoitusta. Tässä työssä havaittiin lisäksi, että kehitetty yksinkertainen valmistusmenetelmä on paitsi toimiva, myös mahdollisesti siirrettävissä rullalta rullalle valmistus- ja tuotantoteknologiaan.
Kehitettyjen anturien kalibrointi suoritettiin homogeenisella taitekerroinmittauksella käyttäen liuoksia, jotka valmistettiin glukoosista ja deionisoidusta vedestä. Kehitettyjen anturien soveltuvuus spesifien molekyylien tunnistamista varten todennettiin tutkimalla vasta-aineiden ja antigeenien sitoutumisreaktioita ja vuorovaikutusta C-reaktiivisella proteiinilla ja sen konjugaateilla. Lisäksi työssä tutkittiin veden absorption vaikutusta mittauksen stabiilisuuteen. Tutkimuksessa suoritettiin vertailu kehitettyjen anturien ja niiden ominaisuuksien välillä kiinnittäen huomiota mittausherkkyyteen, stabiilisuuteen, määritys- ja toteamisrajoihin ja muihin anturien valmistukseen sekä käyttöön liittyviin keskeisiin piirteisiin. Tulokset osoittavat, että Ta2O5-pinnoitetun polymeerivalokanavan mittausherkkyys oli suurin vertailluista rakenteista. Homogeenisessä taitekerroinmittauksessa saavutettu määritys- ja toteamisraja oli 9×10-7 taitekerroinyksikköä (RIU). Pintamassatiheysmittauksessa saavuttu tulos oli 270 fg/mm2.
|
Page generated in 0.0868 seconds