• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Teste de pressão negativa expiratória como proposta de screening para a apneia obstrutiva do sono em pacientes com miastenia gravis / Negative expiratory test as a screening for obstructive sleep apnea in patients with myasthenia gravis

Nacif, Sergio Roberto 16 December 2014 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2016-05-25T18:25:43Z No. of bitstreams: 1 Sergio Roberto Nacif.pdf: 1795162 bytes, checksum: 7b6d72682614593467c7e6265c34a637 (MD5) / Made available in DSpace on 2016-05-25T18:25:43Z (GMT). No. of bitstreams: 1 Sergio Roberto Nacif.pdf: 1795162 bytes, checksum: 7b6d72682614593467c7e6265c34a637 (MD5) Previous issue date: 2014-12-16 / Introduction: Obstructive sleep apnea (OSA) is a breathing disorder characterized by the collapse of the upper airway and has significant prevalence in the general population and specifically in neuromuscular diseases. Objective: To determine the effectiveness of the negative expiratory pressure (NEP) test as a screening to the OSA in myasthenia gravis patients. Method: The study included 15 patients (12 women) from the Setor de Investigação de Doenças Neuromusculares and Associação Brasileira de Miastenia Grave (ABRAMI), which underwent overnight standard polysomnography (PSG), spirometry, manovacuometer and NEP test. Results: The mean age was 41.46 ± 11.32 years, mean weight of 78.4 ± 15.28 kg and the mean body mass index was 29.34 ± 5,3kg / m2. The physiological variables of sleep observed in PSG draw attention to the oxygen saturation nadir, for the sleep latency and total sleep rapid eyes movement (REM) time, apnea-hypopnea index (AHI) and snoring time. The mean AHI was 17.5 ± 21.7, being most obstructive origin events. Regarding the Berlin Questionnaire, only one of the fifteen patients evaluated presented low risk for OSA. Regarding the Epworth Sleepiness Scale, we observed that six patients (40%) did not presented excessive daytime sleepiness, three (20%) had mild drowsiness, five individuos presented moderate (33.4%) and only one patient (6.6%) was classified with severe excessive daytime sleepiness with a score of 22 to a maximum of 24 points. The statistics analyses verify the existence of correlation between anthropometric variables, physiological PSG variables, Epworth Sleepiness Scale and Berlin questionnaire show higher values for body mass index (BMI), waist circumference and AHI. Conclusion: We can conclude that patients with MG have lower values of ventilatory maximum pressures associated with normal lung function. They also feature a considerable number of sleep disordered breathing associated with fall oxyhemoglobin saturation and reduced REM sleep, with consequent presence of excessive daytime sleepiness and high risk for OSA. Although we did not observe a correlation between the PNE test with AHI, our data show that patients with moderate-severe OSA have greatly reduced V0,2% (<20%). / Introdução: A apneia obstrutiva do sono (AOS) é um distúrbio respiratório caracterizado pelo colapso da via aérea superior com importante prevalência na população em geral e especificamente nas doenças neuromusculares. Objetivo: Verificar a eficácia do teste da pressão negativa expiratória (PNE) como proposta de screening para AOS em pacientes com Miastenia gravis. Método: Participaram deste estudo 15 pacientes (12 mulheres) provenientes do Setor de Investigação de Doenças Neuromusculares e Associação Brasileira de Miastenia Grave, os quais foram submetidos à polissonografia basal noturna (PSG), espirometria, manovacuometria e teste da PNE. Resultados: A média de idade foi de 41,46 ± 11,32 anos, peso médio de 78,4 ± 15,28 kg e o índice de massa corpórea médio foi de 29,34 ± 5,3kg/m2. As variáveis fisiológicas do sono observadas na PSG chamam a atenção para a saturação periférica mínima de oxigênio, para a latência e tempo total de sono REM, IAH e tempo de ronco. O IAH médio foi de 17,5 ± 21,7 sendo a maioria eventos obstrutivos. A análise estatística para verificação da existência de correlação entre as variáveis PNE e IAH mostrou um R de -0,5 com um valor de p= 0,06 e, para PNE/IDO/h um R -0,45 com um valor de p= 0,08. Quando correlacionamos os valores obtidos no teste de PNE com pressões de -6 e -10cm/H2O observamos uma excelente correlação de R = 0,825 com um p = 0,0000. Em relação ao questionário clínico de Berlim, dos quinze pacientes avaliados apenas um apresentou baixo risco para AOS. As análises estatísticas para verificação da existência de correlação entre as variáveis antropométricas, fisiológicas da PSG, escala de Epworth e questionário de Berlim mostram valores significativos apenas para o IMC, circunferência abdominal e IAH. Conclusão: Pacientes com MG apresentam redução das pressões máximas ventilatórias associado a função pulmonar normal. Também apresentam um considerável IAH associado a queda da saturação da oxihemoglobina e redução do sono REM, com consequente presença de sonolência excessiva diurna e alto risco para AOS. Embora não tenha sido observado uma correlação entre o teste do PNE com o IAH, nossos dados mostram que pacientes com Myasthenia gravis com AOS moderada-grave apresentam grande redução do V0,2%.

Page generated in 0.0864 seconds