• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • Tagged with
  • 28
  • 28
  • 17
  • 14
  • 9
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da influência dos parâmetros do processo de soldagem TIG sobre a qualidade de uma peça fabricada em aço elétrico silicioso / Influence of TIG welding process parameters on the quality of a piece fabricated with silicon electrical steel

Schlickmann, Marcelo Niehues 05 July 2010 (has links)
Made available in DSpace on 2016-12-08T17:19:35Z (GMT). No. of bitstreams: 1 0 - Capa.pdf: 49375 bytes, checksum: a82e2fca3ff3a4c1780c4fe39da86057 (MD5) Previous issue date: 2010-07-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The TIG welding process (Tungsten Inert Gas), also known as GTAW (Gas Tungsten ArcWelding), is the most commonly used process for welding of thin plates where there is a need for an excellent control of the temperature applied on the piece. This paper presents a study carried out in partnership between the Department of Graduate Studies in Scienceand Materials Engineering and the Department of Industrial Engineering and Stamping of WEG Equipamentos Elétricos S.A Motors Division. It elaborates on the use of the experimental methodology DOE to investigate the influence of TIG welding process parameters, electrical current, welding speed and flow of the shielding gas on the quality of a piece fabricated with silicon electrical steel - ABNT 50F 466M, best known for its 50A 400 specification on the JIS standard. The first step of the study was the designing of the experiment to obtain welded pieces with different combinations of the parameters above mentioned and enable the evaluation of mechanical strength, fillet weld size, hardness and metallographic analysis of the test specimens. The information obtained with analysis of variance techniques (ANOVA) showed that the change in the levels of electrical current and welding speed promotes significant changes in final results. Furthermore, the different rates of gas flow tested caused no differences in response variables of the study. As a result, it was also possible to determine the combinations of these parameters that ensure the required quality and provide increased productivity, energy saving and reduced consumption of the shielding gas. / O processo de soldagem TIG (Tungsten Inert Gas), também conhecido como GTAW (Gas Tungsten Arc Welding), é o processo mais utilizado para a soldagem de chapas finas onde um excelente controle do aporte térmico à peça é necessário. Nesta dissertação é presentado um estudo realizado em parceria entre o Departamento de Pós-Graduação em Ciência e engenharia dos Materiais e os Departamentos de Engenharia Industrial e Estamparia da WEG Equipamentos Elétricos S.A. - Motores. Esse estudo envolveu a utilização da metodologia de delineamento experimental DOE para investigar a influência dos parâmetros do processo de soldagem TIG, corrente elétrica, velocidade de deslocamento da tocha e vazão do gás de proteção, na qualidade de uma peça fabricada com aço elétrico silicioso ABNT 50F 466M, mais conhecido pela classificação 50A 400 da norma JIS. Inicialmente foi elaborado o planejamento do experimento a fim de obter peças soldadas com diferentes combinações dos parâmetros acima mencionados e possibilitar a avaliação da resistência mecânica, dimensão dos cordões de solda, dureza e análise metalográfica dos corpos de prova. Os resultados obtidos, com o auxílio da técnica de análise de variância (ANOVA), mostraram que mudanças nos níveis de corrente e na velocidade de soldagem promoveram alterações significativas nos resultados. Por outro lado, as diferentes taxas de vazão de gás testadas não provocaram diferenças nas variáveis de resposta do estudo. Também foi possível determinar as combinações desses parâmetros que garantem a qualidade requerida e proporcionam aumento de produtividade, economia de energia elétrica e redução no consumo de gás de proteção.
22

Influência do ângulo de preparação da junta no aço tubular AISI 4130 soldado pelo processo TIG / Weld joint's angle preparation influence on steel tube AISI 4130 welded by tig process

Coelho, Fernando 28 February 2018 (has links)
Submitted by Fernando Coelho (coelho-fernet@ig.com.br) on 2018-04-17T15:09:25Z No. of bitstreams: 1 DM17ABR201811h.pdf: 2603442 bytes, checksum: c2422dffe1f0841b0b22aec6f8143ac3 (MD5) / Approved for entry into archive by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br) on 2018-04-18T14:23:57Z (GMT) No. of bitstreams: 1 coelho_f_me_bauru.pdf: 2533903 bytes, checksum: 74e09316ffac9baa3e8d0973642fff7b (MD5) / Made available in DSpace on 2018-04-18T14:23:57Z (GMT). No. of bitstreams: 1 coelho_f_me_bauru.pdf: 2533903 bytes, checksum: 74e09316ffac9baa3e8d0973642fff7b (MD5) Previous issue date: 2018-02-28 / As indústrias metalúrgicas de diversos segmentos buscam continuamente aperfeiçoar seus processos e reduzir custos de produção de estruturas metálicas. Variações em um processo térmico padronizado ou na configuração do produto podem causar alterações na microestrutura e nas propriedades mecânicas do, bem como, no comportamento mecânico do material. Assim, o presente estudo avaliou os efeitos das variações do ângulo de chanfro da junta em tubos de aço redondos AISI 4130 sem costura, quando soldados no processo TIG (Tungsten Inert Gas). Os tubos foram cortados com arco de plasma e preparados com ângulos, 30°, 45° e 60°, e 1 milímetro de altura da raiz. A soldagem foi realizada em dois passes, sendo o primeiro passe na raiz pelo método autógeno e o segundo de preenchimento com metal de adição arame-eletrodo AWSER80S-B2. As juntas soldadas foram submetidas a análises metalográficas de macrografia e microscopia óptica, para avaliação metalúrgica das zonas fundida e afetada pelo calor. Também foi realizado ensaio mecânico de tração e microdureza Vickers para verificar o desempenho mecânico e a dureza do material. A variável de interesse do estudo foi evidenciada por meio da estabilização do processo de corte e soldagem com uso de uma máquina rotativa digital desenvolvida no presente estudo. Os resultados obtidos evidenciaram uniformidade entre os cordões produzidos, variações nas geometrias dos cordões, no tamanho de grão e nas fases de transformação da microestrutura, com impacto na dureza da ZF (Zona Fundida), assim como no desempenho mecânico verificado com ensaios de tração. Conclui-se que, variações no ângulo da junta alteram a área de contato do arco com a poça de fusão, assim como, da poça de fusão com a ZAC. Com isso têm-se diferentes eficiências de transferência de energia térmica por condução, com diferentes ciclos térmicos que resultam em fases e transformações metalúrgicas distintas. / The metallurgical industries at several segments are continuously looking for improving their process and decrease metallic structures production costs. Modifications in a standardized thermal process or in the product configuration can leads to microstructure changes and in the mechanical properties,as well, in the mechanical behavior from the material. Thus, the current study made an assessment of the angle variation effect in steel round tubes joint AISI 4130 without seam, when welded by mechanized TIG process (Tungsten Inert Gas). The steel tubes were cross cut with plasma and prepared in three different angles 30°, 45° and 60°, with 1 millimeter height of root. The welding was made in two passes, the first one in the root by autogenous methode and the second one for filling using eletrode wire AWS ER80S-B2. The welded joints were submitted to metallographic test of macrograph and optical micrographics for metalurgical assessment in the melted zone and the heat affected zone. In addiction was made traction tests and micro hardness Vickers for verify the mechanical behavior and hardness from the material. The interest variable in this study, was evidenced by cut and welding process stabilization using a digital rotative machine developed in this study. The obtained results showed uniformity between weld beads produced with variation in the geometry, as well, in the grain size and in the fases transformations from the microstructure, with impact in the melted zone hardness profile, and in the mechanical properties verified by traction test. It´s pissible conclude that joint chanfer angle variations cause changes in the contact area size between the arc and the molten puddle, and between the molten puddle with the base metal. With this, diferent energy transfer efficency by conduction are obtained producing diferent thermal cicle, that can result in diferent metallurgical fases and microstructure transformations.
23

Caracterização metalúrgica de juntas de aço inoxidável superduplex soldadas por processo TIG autógeno / Characterization of metallurgical stell joints welded stainles superduplex autogenous TIG process

Samuel Amora Alves Neto 28 March 2011 (has links)
Os aços inoxidáveis do tipo duplex possuem grande importância na indústria, principalmente na do petróleo e gás natural, por apresentarem elevada resistência mecânica e excelente resistência à corrosão. Caracterizam-se por apresentar estrutura bifásica, constituída de proporções praticamente iguais de ferrita e austenita. O presente trabalho caracterizou juntas soldadas por TIG autógeno de aço inoxidável duplex UNS S32760. Foram confeccionados quatro grupos de amostras, provenientes da variação da corrente de soldagem e consequentemente do aporte térmico (corrente de pico: 25A e 40A - aporte térmico: 0,12KJ/mm e 0,19KJ/mm) e da composição do gás de proteção (argônio puro ou argônio contendo 2,5% nitrogênio). Foram utilizadas técnicas de caracterização por metalografia colorida, análise e processamento digital de imagens, ensaios de microdureza Vickers. Para avaliar a resistência à corrosão foram realizados ensaios de potencial em circuito aberto com solução de cloreto férrico (FeCl3) e eletrodo de referência de calomelano saturado. A análise quantitativa das fases ferrita e austenita presentes nas juntas soldadas mostrou que a adição de nitrogênio no gás de proteção favoreceu a formação da fase austenita, variando de 11% (sem nitrogênio) para 26% (com nitrogênio) a quantidade desta fase. Em uma análise qualitativa a variação do aporte térmico: 0,12KJ/mm para 0,19KJ/mm resultou no aumento do tamanho de grãos da fase ferrita. / The duplex stainless steels are of great importance in industry, mainly in oil and natural gas due to their high mechanical strength and excellent corrosion resistance. They are characterized by having biphasic structure, consisting of nearly equal proportions of ferrite and austenite. The present work characterized welded joints by autogenous TIG process of duplex stainless UNS S32760. Four groups of samples were prepared, from the variation of welding current and consequently of heat input (20A and 40A - heat input: 0.12KJ/mm and 0.19KJ/mm) and the composition of shielding gas (pure argon or argon containing 2.5% nitrogen). Techniques of characterization by colored metallography, analysis and digital image processing and Vickers microhardness tests techniques were used. To evaluate the corrosion resistance, tests were performed at open circuit potential with a solution of ferric chloride (FeCl3) and reference electrode of saturated calomel. The quantitative analysis of ferrite and austenite phases present in the welded joints showed that the addition of nitrogen in shielding gas favored the formation of austenite phase, ranging from 11% (without nitrogen) to 26% (with nitrogen) the amount of this phase In a qualitative analysis the variation of heat input (0.12KJ/mm and 0.19KJ/mm) resulted in an increase of the ferrite phases grain size.
24

Resistência mecânica e desajuste marginal do titânio comercialmente puro submetido a dois métodos de soldagem: TIG e Laser / Mechanic resistance and marginal misfit of pure Ti submitted to two welding methods TIG and Laser

Atoui, Juliana Abdallah 05 December 2008 (has links)
O objetivo deste trabalho foi avaliar o efeito da soldagem TIG (\"tungsten inert gas\") e compará-la com soldagem a laser, em hastes cilíndricas e supra-estruturas implantosuportadas, confeccionadas em titânio comercialmente puro (Ti cp) por meio dos ensaios de resistência mecânica (tração e flexão) e desajuste marginal, respectivamente. Foram confeccionados noventa corpos-de-prova em titânio cp, sendo sessenta, na forma de hastes cilíndricas, obtidas por fundição de hastes de latão, e trinta na forma de supra-estruturas implanto-suportadas, obtidas por modelo de gesso com quatro análogos de implantes Microunit (Conexão), com dez repetições para cada grupo (controle, solda TIG, solda a Laser). Para a obtenção dos corpos-de-prova, foi realizada inclusão em revestimento Rematitan Plus, de acordo com as instruções fabricante. Os anéis foram submetidos aos ciclos térmicos e posicionados na máquina de fundição (Rematitan), sob arco voltaico, vácuo e atmosfera de argônio, com injeção de titânio sob vácuo-pressão. Após resfriamento, as fundições foram desincluídas e jateadas com óxido de alumínio. Os corpos-de-prova obtidos em forma de hastes cilíndricas foram distribuídos aleatoriamente, em três grupos, para ambos os ensaios, resistência à tração e flexão: grupo controle (sem solda), solda TIG e solda a Laser. As trinta supra-estruturas foram divididas aleatoriamente em três grupos: I- controle - monobloco; II-B- pós-soldagem TIG e III-B- pós-soldagem a Laser; os grupos II-A e III-A, foram constituídos dos espécimes antes do processo de soldagem: II-A- pré-soldagem TIG e III-A- pré-soldagem a Laser. Os dados obtidos para o Ensaio de Tração (MPa) foram analisados estatisticamente pelos testes ANOVA e Tukey (&alpha;= 0,05). O teste complementar de Tukey (p = 0,05) evidenciou que houve diferença entre o grupo controle (605,84 ± 19,83) e os métodos de soldagem TIG (514,90 ± 37,76) e Laser (515,85 ± 62,07). Para o Ensaio de Flexão (MPa), o teste não-paramétrico de Kruskal-Wallis mostrou que não houve diferença estatisticamente significante entre os processos de soldagem TIG (1559,66) e Laser (1621,64), contudo a diferença foi significante entre estes grupos e o controle (1908,75). Para análise dos resultados do desajuste marginal (&mu;m) das supra-estruturas implanto-suportadas, o teste nãoparamétrico de Kruskal-Wallis revelou que não houve diferença estatisticamente significante entre os grupos pós-soldagem TIG (250) e pós-soldagem Laser (241), entretanto, o grupo controle (770) apresentou o maior desajuste. Pelos resultados obtidos e dentro das limitações deste estudo, pode-se afirmar que a soldagem a TIG propicia a obtenção de resultados similares à soldagem a Laser. / The aim of this study was to evaluate the effect of TIG welding (tungsten inert gas) and compare it with Laser welding, of the cylindrical rods and implant-supported frameworks, obtained by in commercially pure titanium (cp) through the mechanical resistance (tensile and flexural strength) and misfit marginal, respectively. Ninety specimens have been fabricated titanium cp, and sixty, cylindrical rods, obtained by casting of the brass rods, and thirty implant-supported frameworks, obtained by plaster die with four similar - Microunit implants (Connection), with ten repetitions for each group (control, TIG welding, laser welding). The specimens were invested in Rematitan Plus, according to the manufacturer instructions. The rings were subjected to thermal cycling and positioned in the machine of casting (Rematitan) under voltaic arc, vacuum and atmosphere of argon, with injection of titanium vacuumpressure. After cooling, were manually and airbone-particle abraded with aluminum oxide. The specimes cylindrical rods were randomly distributed in three groups, for tests, tensile and flexural strength: the control group (without welding), TIG welding and soldering laser. The above thirty-structures were randomly divided into three groups: I- one-piece-cast (control)-, II-B-after-TIG welding and III-B-after-Laser welding, the Group II-A, III-A, consisted of specimens before the process of welding: II-A-before-TIG welding and III-A before-Laser welding. The results for the test Traction were submitted to variance analysis ANOVA (p < 0.05) being observed difference between groups. The supplementary Tukey test (p = 0.05) showed that there was a difference between the control group (605.84 ± 19.83) and the methods of welding TIG (514.90 ± 37.76) and laser (515.85 ± 62.07). To test the Flexion nonparametric test Kruskal-Wallis showed that there was no statistically significant difference between the processes of TIG welding (1559.66) and Laser (1621.64), but the difference was significant between these groups and control (1908.75). For analysis of the results of marginal misfit implant-supported frameworks, the non-parametric Kruskal-Wallis test revealed that there was no statistically significant difference between groups after-TIG welding (250) and after- Laser welding (241), however, the control group (770) showed the largest misfit. With these and the limitations of this study TIG welding in may be to Laser welding.
25

Análise da adaptação marginal de barras Ni-Cr tipo protocolo de Branemark pelo microscópio óptico e pelo microscópico confocal a laser / Marginal adaptation analysis of Ni-Cr bars Branemark protocol type from optical microscope and laser Confocal microscope

Jaccoud, Régis Eduardo Oliveira 28 September 2016 (has links)
A ausência de adaptação passiva em prótese sobre implantes pode sobrecarregar implantes, componentes protéticos e tecido ósseo, levando à perda óssea marginal e até da osseointegração. A soldagem é utilizada com frequência para melhorar o assentamento de estruturas metálicas de próteses em geral e de próteses sobre implantes. Além disso, a precisão no assentamento da peça protética pode estar relacionada com os cuidados na técnica de confecção da mesma. Assim, o objetivo deste trabalho foi avaliar, por meio de microscopia óptica e confocal a laser, a adaptação marginal de barras metálicas tipo protocolo de Branemark, de ligas de niquel-cromo (NiCr) em monobloco e soldadas, confeccionadas a partir de enceramento convencional. Para isso, foi confeccionado um modelo mestre, simulando quatro implantes sobre o qual foram adaptados transferentes e análogos que serviram para transferir a posição dos implantes para o modelo de gesso. Os enceramentos obtidos pelo método convencional foram fundidos em monobloco e em partes separadas (seccionados), sendo os últimos, posteriormente soldados utilizando as técnicas convencional a maçarico e TIG (Tungsten Inert Gas). As leituras da adaptação da barra em cada implante foram feitas nas peças em monobloco (n=5) e nas peças seccionadas (n=10), antes e após as diferentes técnicas de soldagem. Pelo método de medição de microscopia óptica, foram realizadas as medições em duas regiões pré-determinadas ( Vestibular e Lingual ), com três repetições, totalizando 6 leituras por implante. Já no método de microscopia Confocal a laser, foi realizada somente na Vestibular. Para comparar os dados obtidos quanto ao desajuste marginal entre componente protético/implante, considerando-se as peças em monobloco, as peças soldadas, as técnicas de soldagem (maçarico e TIG), os métodos de medição e a posição dos implantes, foram realizados testes estatísticos, onde para cada uma das análises realizadas foi determinada a aplicação do Teste de Normalidade (Shapiro-Wilk ou Kolmogorov-Smirnov (alfa = 5%)) para determinação da distribuição da amostra. Para a amostra com distribuição normal foi determinada a utilização do teste paramétrico, Análise de Variância, enquanto que a amostra com distribuição não normal, determinou-se a utilização do teste não paramétrico de Kruskal Wallis. Os resultados encontrados foram estatisticamente significantes para comparação método e técnica, sugerindo que as peças em monobloco apresentaram maior desadaptação que as peças soldadas, e que as peças soldadas pela técnica convencional não apresentaram diferença estatística, em relação as soldadas pela técnica TIG. Em relação a comparação dos métodos de medição, houve diferença estaticamente significante, onde a microscopia Confocal a laser obteve os maiores valores de desadaptação. A interação técnica e método não houve diferenças estatísticas. Na comparação de diferentes secções e soldada, para os 2 métodos de medição, em relação ao fator Secção, não houve diferença significante onde 3 secções apresentam os menores resultados e as soldadas tiveram igualdade em relação a 1 secção. Pelo fator Técnica houve diferença estatisticamente significante, onde a técnica convencional obteve as maiores médias. A interação Secção e Técnica, não teve efeito significante. A adaptação marginal da peça em relação a posição do implante na arcada, não houve diferença estatística, para ambos os métodos. Houve diferença apenas no fator Técnica, pela microscopia óptica, onde a Monobloco teve os maiores resultados e a Solda Convencional e TIG, tiveram igualdade nos resultados. A investigação de sistemas de confecção de estruturas da prótese e de técnicas de soldagem é importante na busca pela produção de próteses sobre dente ou sobre implante com precisão no ajuste marginal que possa ser comprovado visual e numericamente utilizando-se recursos tecnológicos que assegurem a utilização clínica das peças protéticas. / The lack of passive adaptation in prosthesis over implant can overload implants, prosthetics components and bone tissue, leading to marginal bone loss and even osseointegration. Weldering is used frequently to improve the settlement of metal structures of prosthetic in general and prosthesis over implants. In addition, the settlement precision of the workpiece may be related to the care in the technique of manufacturing the same. The objective of this study was to evaluate, through optical and confocal Laser microscopy, the marginal adaptation of metal bars Branemark protocol type alloy nickel-chromium (NiCr) monoblock and welded, made from conventional waxing .For this, a master model was made to simulate four implants were adapted over which transferents and analogs that served to transfer the position of the implants for the cast model. Waxing obtained by the conventional method were cast in one-piece and separate parts (sectioned), the latter being subsequently welded using the conventional techniques blowtorch and TIG (Tungsten Inert Gas).The bar adjustment of readings in each implant were made in monoblock pieces (n = 5) and the severed pieces (n = 10) before and after different weldering techniques. By optical microscopy measurement method, measurements were performed in two predetermined regions (Vestibular and lingual), with three replications, totaling 6 readings per implant. However in the methodology of Confocal laser microscope, was done only on Vestibular. To compare the data obtained on the misfit between prosthetic/implant component, considering the pieces monoblock, the welded parts, the weldering techniques (torch and TIG), measurement methods and the position of the implants, tests were performed statistical where for each of the analyzes determined the application of Normality Test (Shapiro-Wilk test and Kolmogorov-Smirnov test (alpha = 5%)) to determine the distribution of the sample. For the sample of normal distribution was determined using the parametric test, analysis of variance, while the sample with non-normal distribution was determined using the nonparametric Kruskal-Wallis test. The results found were statistically significant for method and technique comparison, suggesting that the monoblock parts showed higher misfit than welded parts, and the parts welded by conventional technique showed no statistical difference in relation welded by TIG technique. Regarding the comparison of measurement methods, there was no statistically significant difference, where the Laser Confocal microscopy obtained the greatest misfit. The technical interaction and method there were no statistical differences. When comparing different sections and welded to the two measurement methods, in relation to Section factor, there was no significant difference where 3 sections have the lowest results and welded had equality with 1 section. The technical factor was no statistically significant difference, the conventional technique had the highest averages. The interaction and Technical Section had no significant effect. The marginal adaptation of the play in relation to the implant in the arch position, there was no statistical difference for both methods. There was a difference only in the technical factor, by optical microscopy, where Monoblock had the greatest results and Conventional Welding and TIG, had equality in results. The research of making the prosthesis structures systems and weldering techniques is important in the search for production of prosthetic tooth or on precisely implant the marginal adjustment that can be verified visually and numerically using technological resources to ensure clinical use of prosthetic pieces.
26

Resistência mecânica e desajuste marginal do titânio comercialmente puro submetido a dois métodos de soldagem: TIG e Laser / Mechanic resistance and marginal misfit of pure Ti submitted to two welding methods TIG and Laser

Juliana Abdallah Atoui 05 December 2008 (has links)
O objetivo deste trabalho foi avaliar o efeito da soldagem TIG (\"tungsten inert gas\") e compará-la com soldagem a laser, em hastes cilíndricas e supra-estruturas implantosuportadas, confeccionadas em titânio comercialmente puro (Ti cp) por meio dos ensaios de resistência mecânica (tração e flexão) e desajuste marginal, respectivamente. Foram confeccionados noventa corpos-de-prova em titânio cp, sendo sessenta, na forma de hastes cilíndricas, obtidas por fundição de hastes de latão, e trinta na forma de supra-estruturas implanto-suportadas, obtidas por modelo de gesso com quatro análogos de implantes Microunit (Conexão), com dez repetições para cada grupo (controle, solda TIG, solda a Laser). Para a obtenção dos corpos-de-prova, foi realizada inclusão em revestimento Rematitan Plus, de acordo com as instruções fabricante. Os anéis foram submetidos aos ciclos térmicos e posicionados na máquina de fundição (Rematitan), sob arco voltaico, vácuo e atmosfera de argônio, com injeção de titânio sob vácuo-pressão. Após resfriamento, as fundições foram desincluídas e jateadas com óxido de alumínio. Os corpos-de-prova obtidos em forma de hastes cilíndricas foram distribuídos aleatoriamente, em três grupos, para ambos os ensaios, resistência à tração e flexão: grupo controle (sem solda), solda TIG e solda a Laser. As trinta supra-estruturas foram divididas aleatoriamente em três grupos: I- controle - monobloco; II-B- pós-soldagem TIG e III-B- pós-soldagem a Laser; os grupos II-A e III-A, foram constituídos dos espécimes antes do processo de soldagem: II-A- pré-soldagem TIG e III-A- pré-soldagem a Laser. Os dados obtidos para o Ensaio de Tração (MPa) foram analisados estatisticamente pelos testes ANOVA e Tukey (&alpha;= 0,05). O teste complementar de Tukey (p = 0,05) evidenciou que houve diferença entre o grupo controle (605,84 ± 19,83) e os métodos de soldagem TIG (514,90 ± 37,76) e Laser (515,85 ± 62,07). Para o Ensaio de Flexão (MPa), o teste não-paramétrico de Kruskal-Wallis mostrou que não houve diferença estatisticamente significante entre os processos de soldagem TIG (1559,66) e Laser (1621,64), contudo a diferença foi significante entre estes grupos e o controle (1908,75). Para análise dos resultados do desajuste marginal (&mu;m) das supra-estruturas implanto-suportadas, o teste nãoparamétrico de Kruskal-Wallis revelou que não houve diferença estatisticamente significante entre os grupos pós-soldagem TIG (250) e pós-soldagem Laser (241), entretanto, o grupo controle (770) apresentou o maior desajuste. Pelos resultados obtidos e dentro das limitações deste estudo, pode-se afirmar que a soldagem a TIG propicia a obtenção de resultados similares à soldagem a Laser. / The aim of this study was to evaluate the effect of TIG welding (tungsten inert gas) and compare it with Laser welding, of the cylindrical rods and implant-supported frameworks, obtained by in commercially pure titanium (cp) through the mechanical resistance (tensile and flexural strength) and misfit marginal, respectively. Ninety specimens have been fabricated titanium cp, and sixty, cylindrical rods, obtained by casting of the brass rods, and thirty implant-supported frameworks, obtained by plaster die with four similar - Microunit implants (Connection), with ten repetitions for each group (control, TIG welding, laser welding). The specimens were invested in Rematitan Plus, according to the manufacturer instructions. The rings were subjected to thermal cycling and positioned in the machine of casting (Rematitan) under voltaic arc, vacuum and atmosphere of argon, with injection of titanium vacuumpressure. After cooling, were manually and airbone-particle abraded with aluminum oxide. The specimes cylindrical rods were randomly distributed in three groups, for tests, tensile and flexural strength: the control group (without welding), TIG welding and soldering laser. The above thirty-structures were randomly divided into three groups: I- one-piece-cast (control)-, II-B-after-TIG welding and III-B-after-Laser welding, the Group II-A, III-A, consisted of specimens before the process of welding: II-A-before-TIG welding and III-A before-Laser welding. The results for the test Traction were submitted to variance analysis ANOVA (p < 0.05) being observed difference between groups. The supplementary Tukey test (p = 0.05) showed that there was a difference between the control group (605.84 ± 19.83) and the methods of welding TIG (514.90 ± 37.76) and laser (515.85 ± 62.07). To test the Flexion nonparametric test Kruskal-Wallis showed that there was no statistically significant difference between the processes of TIG welding (1559.66) and Laser (1621.64), but the difference was significant between these groups and control (1908.75). For analysis of the results of marginal misfit implant-supported frameworks, the non-parametric Kruskal-Wallis test revealed that there was no statistically significant difference between groups after-TIG welding (250) and after- Laser welding (241), however, the control group (770) showed the largest misfit. With these and the limitations of this study TIG welding in may be to Laser welding.
27

Análise da adaptação marginal de barras Ni-Cr tipo protocolo de Branemark pelo microscópio óptico e pelo microscópico confocal a laser / Marginal adaptation analysis of Ni-Cr bars Branemark protocol type from optical microscope and laser Confocal microscope

Régis Eduardo Oliveira Jaccoud 28 September 2016 (has links)
A ausência de adaptação passiva em prótese sobre implantes pode sobrecarregar implantes, componentes protéticos e tecido ósseo, levando à perda óssea marginal e até da osseointegração. A soldagem é utilizada com frequência para melhorar o assentamento de estruturas metálicas de próteses em geral e de próteses sobre implantes. Além disso, a precisão no assentamento da peça protética pode estar relacionada com os cuidados na técnica de confecção da mesma. Assim, o objetivo deste trabalho foi avaliar, por meio de microscopia óptica e confocal a laser, a adaptação marginal de barras metálicas tipo protocolo de Branemark, de ligas de niquel-cromo (NiCr) em monobloco e soldadas, confeccionadas a partir de enceramento convencional. Para isso, foi confeccionado um modelo mestre, simulando quatro implantes sobre o qual foram adaptados transferentes e análogos que serviram para transferir a posição dos implantes para o modelo de gesso. Os enceramentos obtidos pelo método convencional foram fundidos em monobloco e em partes separadas (seccionados), sendo os últimos, posteriormente soldados utilizando as técnicas convencional a maçarico e TIG (Tungsten Inert Gas). As leituras da adaptação da barra em cada implante foram feitas nas peças em monobloco (n=5) e nas peças seccionadas (n=10), antes e após as diferentes técnicas de soldagem. Pelo método de medição de microscopia óptica, foram realizadas as medições em duas regiões pré-determinadas ( Vestibular e Lingual ), com três repetições, totalizando 6 leituras por implante. Já no método de microscopia Confocal a laser, foi realizada somente na Vestibular. Para comparar os dados obtidos quanto ao desajuste marginal entre componente protético/implante, considerando-se as peças em monobloco, as peças soldadas, as técnicas de soldagem (maçarico e TIG), os métodos de medição e a posição dos implantes, foram realizados testes estatísticos, onde para cada uma das análises realizadas foi determinada a aplicação do Teste de Normalidade (Shapiro-Wilk ou Kolmogorov-Smirnov (alfa = 5%)) para determinação da distribuição da amostra. Para a amostra com distribuição normal foi determinada a utilização do teste paramétrico, Análise de Variância, enquanto que a amostra com distribuição não normal, determinou-se a utilização do teste não paramétrico de Kruskal Wallis. Os resultados encontrados foram estatisticamente significantes para comparação método e técnica, sugerindo que as peças em monobloco apresentaram maior desadaptação que as peças soldadas, e que as peças soldadas pela técnica convencional não apresentaram diferença estatística, em relação as soldadas pela técnica TIG. Em relação a comparação dos métodos de medição, houve diferença estaticamente significante, onde a microscopia Confocal a laser obteve os maiores valores de desadaptação. A interação técnica e método não houve diferenças estatísticas. Na comparação de diferentes secções e soldada, para os 2 métodos de medição, em relação ao fator Secção, não houve diferença significante onde 3 secções apresentam os menores resultados e as soldadas tiveram igualdade em relação a 1 secção. Pelo fator Técnica houve diferença estatisticamente significante, onde a técnica convencional obteve as maiores médias. A interação Secção e Técnica, não teve efeito significante. A adaptação marginal da peça em relação a posição do implante na arcada, não houve diferença estatística, para ambos os métodos. Houve diferença apenas no fator Técnica, pela microscopia óptica, onde a Monobloco teve os maiores resultados e a Solda Convencional e TIG, tiveram igualdade nos resultados. A investigação de sistemas de confecção de estruturas da prótese e de técnicas de soldagem é importante na busca pela produção de próteses sobre dente ou sobre implante com precisão no ajuste marginal que possa ser comprovado visual e numericamente utilizando-se recursos tecnológicos que assegurem a utilização clínica das peças protéticas. / The lack of passive adaptation in prosthesis over implant can overload implants, prosthetics components and bone tissue, leading to marginal bone loss and even osseointegration. Weldering is used frequently to improve the settlement of metal structures of prosthetic in general and prosthesis over implants. In addition, the settlement precision of the workpiece may be related to the care in the technique of manufacturing the same. The objective of this study was to evaluate, through optical and confocal Laser microscopy, the marginal adaptation of metal bars Branemark protocol type alloy nickel-chromium (NiCr) monoblock and welded, made from conventional waxing .For this, a master model was made to simulate four implants were adapted over which transferents and analogs that served to transfer the position of the implants for the cast model. Waxing obtained by the conventional method were cast in one-piece and separate parts (sectioned), the latter being subsequently welded using the conventional techniques blowtorch and TIG (Tungsten Inert Gas).The bar adjustment of readings in each implant were made in monoblock pieces (n = 5) and the severed pieces (n = 10) before and after different weldering techniques. By optical microscopy measurement method, measurements were performed in two predetermined regions (Vestibular and lingual), with three replications, totaling 6 readings per implant. However in the methodology of Confocal laser microscope, was done only on Vestibular. To compare the data obtained on the misfit between prosthetic/implant component, considering the pieces monoblock, the welded parts, the weldering techniques (torch and TIG), measurement methods and the position of the implants, tests were performed statistical where for each of the analyzes determined the application of Normality Test (Shapiro-Wilk test and Kolmogorov-Smirnov test (alpha = 5%)) to determine the distribution of the sample. For the sample of normal distribution was determined using the parametric test, analysis of variance, while the sample with non-normal distribution was determined using the nonparametric Kruskal-Wallis test. The results found were statistically significant for method and technique comparison, suggesting that the monoblock parts showed higher misfit than welded parts, and the parts welded by conventional technique showed no statistical difference in relation welded by TIG technique. Regarding the comparison of measurement methods, there was no statistically significant difference, where the Laser Confocal microscopy obtained the greatest misfit. The technical interaction and method there were no statistical differences. When comparing different sections and welded to the two measurement methods, in relation to Section factor, there was no significant difference where 3 sections have the lowest results and welded had equality with 1 section. The technical factor was no statistically significant difference, the conventional technique had the highest averages. The interaction and Technical Section had no significant effect. The marginal adaptation of the play in relation to the implant in the arch position, there was no statistical difference for both methods. There was a difference only in the technical factor, by optical microscopy, where Monoblock had the greatest results and Conventional Welding and TIG, had equality in results. The research of making the prosthesis structures systems and weldering techniques is important in the search for production of prosthetic tooth or on precisely implant the marginal adjustment that can be verified visually and numerically using technological resources to ensure clinical use of prosthetic pieces.
28

Avaliação da corrosão em juntas soldadas de fios dissimilares Ni-Ti/Ti-Mo obtidas pelo processo de TIG. / Evaluation of corrosion in weld joints of dissimilar Ni-Ti / Ti-Mo wires obtained by the TIG process.

COSTA, Josiane Dantas. 16 March 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-03-16T19:08:32Z No. of bitstreams: 1 JOSIANE DANTAS COSTA - DISSERTAÇÃO PPGEQ 2015..pdf: 2694660 bytes, checksum: b1f464f2e8b29d82a5339c5bd52471b3 (MD5) / Made available in DSpace on 2018-03-16T19:08:32Z (GMT). No. of bitstreams: 1 JOSIANE DANTAS COSTA - DISSERTAÇÃO PPGEQ 2015..pdf: 2694660 bytes, checksum: b1f464f2e8b29d82a5339c5bd52471b3 (MD5) Previous issue date: 2015-09-29 / A liga de Ni-Ti, conhecida por Nitinol, é constituída dos elementos níquel e titânio e vem sendo bastante aplicada nas mais diversas áreas: aeroespacial, automotiva, construção civil, dispositivos médicos e ortodônticos. Esse potencial de aplicação decorre das propriedades particulares de efeito de memória de forma e superelasticidade, associada a uma boa resistência à corrosão e excelente biocompatibilidade. Com intuito de aumentar as aplicações desse material em dispositivos médicos, o desenvolvimento de tecnologias de união torna-se necessário para possibilitar a fabricação das mais diferentes formas geométricas e combinações entre materiais similares e dissimilares. Nesse contexto, é fundamental que se realize estudos sobre a resistência a corrosão da região em que foi feita a união (junta), principalmente quando utilizados processos de soldagem, já que podem deixar falhas induzindo a uma maior suscetibilidade a corrosão. Diante disto, neste trabalho foi realizada a união de fios ortodônticos de Ni-Ti com fios ortodônticos de Ti-Mo através do processo de soldagem TIG (“Tungsten Inert Gas”) autógeno. Como se trata de biomateriais, este estudo teve como objetivo geral avaliar a resistência à corrosão dos fios comerciais íntegros e da junta soldada Ni-Ti/Ti-Mo em solução salina tamponada SBF (“Saline Buffered Phosphate”) que simula o sangue humano, para verificar se a soldagem afetaria a resistência a corrosão das juntas. Os resultados obtidos revelaram que o processo da soldagem TIG utilizado neste trabalho gerou juntas soldadas de excelente qualidade, apresentando uma resistência à corrosão superior à dos fios íntegros. O planejamento experimental utilizado para verificar a influência da temperatura e do tempo do tratamento térmico nos resultados de corrosão, gerou um experimento ótimo com temperatura de 350°C e um tempo de 40 minutos. Este resultado foi confirmado através dos ensaios de espectroscopia de impedância eletroquímica. / The Ni-Ti alloy, known as Nitinol, is made of nickel and titanium elements and has been widely applied in several areas: aerospace, automotive, construction, medical and orthodontic appliances. Nitinol's application potential is due to its particular superelasticity properties and shape memory effect associated with a good corrosion resistance and excellent biocompatibility. In order to increase the applications of this material in medical devices, the development of joining technologies is necessary to enable manufacture of the most different geometric shapes and combinations of similar and dissimilar materials. In this context, it is essential to conduct studies on the corrosion resistance of the region where the union (joint) was done, especially when welding processes are used, as they can leave gaps leading to greater susceptibility to corrosion. With this in mind, this work carried out the union of Ni-Ti orthodontic wire with Ti-Mo orthodontic wire through the autogenous TIG (Tungsten Inert Gas) welding process. As biomaterials are involved, this study aimed to evaluate the corrosion resistance of the upright commercial wire and welded joint Ni-Ti/Ti-Mo in buffered saline solution SBP (Saline Buffered Phosphate) which simulates human blood, to check if the welding would affect the corrosion resistance of the joint. The results revealed that the TIG welding process used in this work generated welds of excellent quality, having a corrosion resistance higher than that of intact wires. The experimental design used to determine the influence of temperature and time of heat treatment on the results of corrosion generated a great experiment with temperature of 350 ° C and a time of 40 minutes. This result was confirmed by means of electrochemical impedance spectroscopy test.

Page generated in 0.0682 seconds