• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 258
  • 82
  • 39
  • 13
  • 9
  • 6
  • 5
  • 5
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 504
  • 232
  • 102
  • 56
  • 52
  • 51
  • 49
  • 49
  • 47
  • 44
  • 41
  • 41
  • 39
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
501

Fabrication and analysis of CIGS nanoparticle-based thin film solar cells

Ghane, Parvin 20 November 2013 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Fabrication and analysis of Copper Indium Gallium di-Selenide (CIGS) nanoparticles-based thin film solar cells are presented and discussed. This work explores non-traditional fabrication processes, such as spray-coating for the low-cost and highly-scalable production of CIGS-based solar cells. CIGS nanoparticles were synthesized and analyzed, thin CIGS films were spray-deposited using nanoparticle inks, and resulting films were used in low-cost fabrication of a set of CIGS solar cell devices. This synthesis method utilizes a chemical colloidal process resulting in the formation of nanoparticles with tunable band gap and size. Based on theoretical and experimental studies, 100 nm nanoparticles with an associated band gap of 1.33 eV were selected to achieve the desired film characteristics and device performances. Scanning electron microcopy (SEM) and size measurement instruments (Zetasizer) were used to study the size and shape of the nanoparticles. Electron dispersive spectroscopy (EDS) results confirmed the presence of the four elements, Copper (Cu), Indium (In), Gallium (Ga), and Selenium (Se) in the synthesized nanoparticles, while X-ray diffraction (XRD) results confirmed the tetragonal chalcopyrite crystal structure. The ultraviolet-visible-near infra-red (UV-Vis-NIR) spectrophotometry results of the nanoparticles depicted light absorbance characteristics with good overlap against the solar irradiance spectrum. The depositions of the nanoparticles were performed using spray-coating techniques. Nanoparticle ink dispersed in ethanol was sprayed using a simple airbrush tool. The thicknesses of the deposited films were controlled through variations in the deposition steps, substrate to spray-nozzle distance, size of the nozzle, and air pressure. Surface features and topology of the spray-deposited films were analyzed using atomic force microscopy (AFM). The deposited films were observed to be relatively uniform with a minimum thickness of 400 nm. Post-annealing of the films at various temperatures was studied for the photoelectric performance of the deposited films. Current density and voltage (J/V) characteristics were measured under light illumination after annealing at different temperatures. It was observed that the highest photoelectric effect resulted in annealing temperatures of 150-250 degree centigrade under air atmosphere. The developed CIGS films were implemented in solar cell devices that included Cadmium Sulfide (CdS) and Zinc Oxide (ZnO) layers. The CdS film served as the n-type layer to form a pn junction with the p-type CIGS layer. In a typical device, a 300 nm CdS layer was deposited through chemical bath deposition on a 1 $mu$m thick CIGS film. A thin layer of intrinsic ZnO was spray coated on the CdS film to prevent shorting with the top conductor layer, 1.5 μm spray-deposited aluminum doped ZnO layer. A set of fabricated devices were tested using a Keithley semiconductor characterization instrument and micromanipulator probe station. The highest measured device efficiency was 1.49%. The considered solar cell devices were simulated in ADEPT 2.0 solar cell simulator based on the given fabrication and experimental parameters. The simulation module developed was successfully calibrated with the experimental results. This module can be used for future development of the given work.
502

Fraktionierung des Chemischen Sauerstoffbedarfs mithilfe von Extinktionsmessungen im UV/Vis-Spektralbereich

Weber, Steffen 21 April 2023 (has links)
Das Messverfahren der optischen Spektrophotometrie wird zur kontinuierlichen Messung der Abwasserqualität auf ihre Einsatztauglichkeit überprüft. Der chemische Sauerstoffbedarf (CSB) wird als zentraler Kennwert für die stoffliche Verschmutzung von Abwasser und für dessen Nachweis in Oberflächengewässern eingesetzt, welche es zu bestimmen galt. Dabei wird der Informationsgehalt über eine organische, summarische Kohlenstoffbelastung mittels einer zusätzlichen Fraktionierung erhöht. In einer Labormesskampagne werden auf der Grundlage von Respirationsversuchen Daten aus Extinktionswerten des UV/Vis-Spektrums und Referenzwerten (Standardanalyseparameter und simulierte Stoffkonzentrationen mithilfe des Activated Sludge Modell No. 1) generiert. Darauf aufbauend werden Kalibrationsmodelle für den CSB und einzelne Fraktionen entwickelt. Die Modelle werden mithilfe des Regressionsansatzes der Partial-Least-Squares entwickelt und im Rahmen eines Anwendungsbeispiels auf ihre Praxistauglichkeit überprüft. Als Ergebnis dieser Arbeit stehen Kalibrationsmodelle für den Einsatz im kommunalem Abwasser unter Trockenwetterbedingungen zur Verfügung. Die Vorhersagequalität nimmt mit zunehmender Differenzierung ab. Von einer Weiterverwendung der berechneten Äquivalentkonzentrationen für die CSB-Fraktionen (SS, XS, SI und XI), z. B. als Kalibriergröße für Stofftransportmodelle oder als Steuer- und Regelgröße, wird allerdings abgeraten. Als Ursache für die hohen Messungenauigkeiten wurde eine unzureichende Anpassung an die Veränderungen in der Abwasserzusammensetzung während eines Trockenwettertagesganges identifiziert. Mit einer erweiterten Datengrundlage, unter der Verwendung von Standardanalyseparametern (CSB, CSBmf und BSB) in einer Abwasserprobe, welche für den Ausschluss von Stoffverbindungen vor und nach einer respirativen Vorbehandlung bestimmt werden, wird eine höhere Modellgüte in Aussicht gestellt. Darüber hinaus wird ein Umdenken hinsichtlich statischer - hin zu dynamischen - Kalibrationsfunktionen für UV/Vis-Sensoren vorgeschlagen. Eine Generalisierbarkeit der entwickelten Kalibrationsmodelle auf weitere Wetterbedingungen, Messstandorte oder Sensoren wird nicht empfohlen.:Abbildungen VI Tabellen XIII Abkürzungen XV 1 Einleitung 1 1.1 Motivation 1 1.2 Zielstellung 2 2 Stand der Forschung 5 2.1 Kohlenstoffe 6 2.1.1 Zusammensetzung und Herkunft im häuslichen Abwasser 7 2.1.1.1 Fette 8 2.1.1.2 Proteine 8 2.1.1.3 Tenside 9 2.1.1.4 Phenole 10 2.1.1.5 Kohlenwasserstoffe 10 2.1.2 Fraktionierung von Kohlenstoffverbindungen 11 2.1.2.1 Chemischer Sauerstoffbedarf 12 2.1.2.2 Ansätze zur CSB-Fraktionierung 12 2.1.2.3 Stoffzusammensetzung einzelner CSB-Fraktionen 15 2.1.2.4 Messmethoden zur Bestimmung des CSB 18 2.2 Optische Spektroskopie 20 2.2.1 Grundlagen 20 2.2.1.1 Elektromagnetische Strahlung 20 2.2.1.2 Einordnung der optischen Spektroskopie 21 2.2.1.3 Lichtabsorption 21 2.2.1.4 Chemisch-physikalische Grundlagen 22 2.2.1.5 Mathematische Grundlagen 24 2.2.1.6 Extinktionsmessung 25 2.2.2 Online-Messtechnik 26 2.2.2.1 Sensoren /-hersteller 26 2.2.2.2 Kalibrierung 26 2.2.2.2.1 Kalibrierung der S::CAN MESSTECHNIK GmbH 27 2.2.2.2.2 Unabhängige Analyseverfahren zur Auswertung spektrophotometrischer Messreihen 28 2.2.2.3 Messung 29 2.2.2.3.1 Einstellungen und Voraussetzungen 29 2.2.2.3.2 Qualitative Einflussnahme von Störgrößen auf die spektroskopische Datenerfassung 30 2.2.3 Einsatz in der Siedlungswasserwirtschaft und Hydrologie 31 3 Versuchsdurchführung und Analytik 33 3.1 Messkampagnen 33 3.1.1 Labormessversuche 33 3.1.1.1 Respirationsversuch 34 3.1.1.1.1 Versuchsaufbau zum Respirationsversuch 35 3.1.1.1.2 Betriebshinweise Respirationsversuch 38 3.1.1.2 Verdünnungsversuch 41 3.1.1.2.1 Versuchsaufbau zum Verdünnungsversuch 42 3.1.1.2.2 Betriebshinweise Verdünnungsversuch 43 3.1.2 Feldmessversuch 43 3.1.2.1 Versuchsaufbau zum Feldmessversuch 44 3.1.2.2 Betriebshinweise Feldmessversuch 46 3.2 Abwasserproben: Aufbewahrung und Analytik 47 3.2.1 Konservierung und Probenvorbehandlung 48 3.2.2 Standardisierte Laboranalyseverfahren 49 3.2.2.1 CSB 49 3.2.2.2 Biologischer Sauerstoffbedarf BSBn 50 3.3 Mess- und Regelinstrumente 51 3.3.1 Optischer Multiparameter-Sensor 51 3.3.2 Luminescent Dissolved Oxygen-Sensor (LDO) 53 3.3.3 Peristaltik-Pumpe 54 3.3.4 Dispergierer 54 4 Untersuchungen zur Entwicklung und Anwendung von UV/Vis-Kalibrierungen 55 4.1 Statistische Verfahren zur Kalibrierung 55 4.1.1 Datengrundlage und Methoden 56 4.1.1.1 Datengrundlage 56 4.1.1.2 Multivariate Datenanalyse 57 4.1.1.2.1 Regressionsanalyse 58 4.1.1.2.1.1 Schätzung der Regressionsfunktion 59 4.1.1.2.2 Qualitätsprüfung 61 4.1.1.2.3 Prüfung der Modellprämissen 63 4.1.1.2.4 Multivariate Regressionsanalyse 66 4.1.1.3 Vergleich der Kalibrierverfahren 70 4.1.2 Ergebnisse 70 4.1.2.1 Regressionsansätze für UV/Vis-Kalibrierung 70 4.1.2.1.1 Partial-Least-Squares Regression (PLS-R) 70 4.1.2.1.2 Lasso-Regression 73 4.1.2.1.3 Herstellerkalibrierung (SCAN GmbH) 73 4.1.2.1.3.1 Anwendung der globalen Herstellerkalibrierung 73 4.1.2.1.3.2 Lokal angepasste Herstellerkalibrierung 74 4.1.3 Auswertungen 75 4.1.3.1 Tauglichkeit angewandter Regressionsansätze zur Entwicklung von UV/Vis-Kalibrierfunktionen 75 4.1.3.1.1 Vergleich der Vorhersagequalitäten zwischen Regressionsansätzen und Herstellerkali¬- brierung 75 4.1.3.1.2 Aussagekraft angewandter Regressionsmodelle 77 4.1.3.1.2.1 Regressionsfunktion und -koeffizienten 77 4.1.3.1.2.2 Modellprämissen 78 4.1.3.2 Identifizierung signifikanter WL oder -Bereiche 80 4.2 Fraktionierung von CSB-Verbindungen 81 4.2.1 Datengrundlage und Methoden 82 4.2.1.1 Laborwertmethode 83 4.2.1.2 Modellwertmethode 85 4.2.1.2.1 Respirometrische Messung 86 4.2.1.2.2 Sauerstoffverbrauchsrate 87 4.2.1.2.3 Modellberechnung 89 4.2.1.2.4 Simulationsmethode mit modifiziertem Activated Sludge Modell No. 1 92 4.2.1.2.5 Modellkalibrierung 95 4.2.1.2.6 Datenauswahl 96 4.2.1.3 Lichtabsorptionsmethode 96 4.2.2 Ergebnisse 97 4.2.2.1 Modellwertmethode mit ASM No. 1 97 4.2.2.2 Auswahl von Modelldaten 100 4.2.2.3 UV/Vis-Kalibrierfunktionen 101 4.2.2.3.1 CSB-Fraktionen 101 4.2.2.3.2 Vergleich MW- und LW-Modell 103 4.2.3 Auswertungen 104 4.2.3.1 Tauglichkeit von Simulationsergebnissen aus Modellwertmethode zur Entwicklung von Kalibrierfunktionen 104 4.2.3.2 Abweichende Vorhersagequalitäten zwischen den UV/Vis-Kalibrierfunktionen 106 4.2.3.3 Messunsicherheiten und Modellqualität 107 4.2.3.4 Signifikante Wellenlängen oder -bereiche für einzelne CSB-Fraktionen 109 4.3 Anwendungsbeispiel: Kohlenstoffumsatz entlang einer Fließstrecke 111 4.3.1 Datengrundlage und Methoden 112 4.3.1.1 Einsatz von UV/Vis-Messtechnik 115 4.3.1.1.1 Vergleichbarkeit bei Parallelbetrieb baugleicher Sensoren 115 4.3.1.1.1.1 Versuchsdurchführung 116 4.3.1.1.1.2 Berechnungsansätze 116 4.3.1.1.2 Lokale Kalibrierung 117 4.3.1.1.2.1 Univariat 118 4.3.1.1.2.2 Multivariat 118 4.3.1.2 Kohlenstoffumwandlung und -umsatz innerhalb des Durchflussreaktors 118 4.3.1.2.1 Vorverarbeitung von UV/Vis-Daten 120 4.3.1.2.2 Zeitsynchronisation mithilfe der Fließzeit 120 4.3.1.2.3 Bestimmung von stofflichen Veränderungen in einem Wasserpaket 121 4.3.2 Ergebnisse 122 4.3.2.1 Praxiseinsatz von UV/Vis-Messtechnik 122 4.3.2.1.1 Stabilität und Vergleichbarkeit von Messsignalen bei unterschiedlichen Sensoren 122 4.3.2.1.1.1 Messgüte 122 4.3.2.1.1.2 Sensoranpassung 124 4.3.2.1.2 UV/Vis-Kalibrationsfunktionen 125 4.3.2.1.2.1 Validierung LK-PLS-R 126 4.3.2.1.2.2 Lokale Nachkalibrierung LK-PLS-R 128 4.3.2.1.3 Anwendung entwickelter Kalibrationsmodelle auf Zeitreihen 130 4.3.2.2 Kohlenstoffumsatz 131 4.3.3 Auswertungen 135 4.3.3.1 Tauglichkeit von UV/Vis-Messtechnik für den Einsatz in der Kanalisation 135 4.3.3.1.1 Vorhersagegenauigkeit von Kalibrationsfunktionen 135 4.3.3.1.2 Abweichende Messergebnisse der Extinktion von einzelnen Sensoren 135 4.3.3.2 Veränderungen in den Konzentrationen einzelner Kohlenstofffraktionen entlang der Fließstrecke 136 5 Diskussion 139 6 Ausblick 151 7 Zusammenfassung 153 8 Literaturverzeichnis 157 A Anhang 171 A.1 Respirationsversuche CSB-Fraktionen 171 A.1.1 Quellcode - CSB-Fraktionierung 171 A.1.2 Respirationsversuche CSB-Fraktionen 175 A.1.3 Quellcode - PLS-Regression 178 A.1.4 UV/Vis-Kalibrierung - CSB-Fraktionen 180 A.1.5 Modellgüte 183 A.1.6 Modellprämissen 184 A.2 Feldmesskampagne 188 A.2.1 Sensorkompensation 188 A.2.2 Korrelationsplots 189 A.2.2.1 Validierung der Kalibrationsmodelle 189 A.2.2.2 Nachkalibrierung der Kalibrationsmodelle 192 A.2.2.2.1 univariat 192 A.2.3 Stoffliche Veränderungen in Wasserpaketen 198 A.2.4 Laboranalysen Stoffliche Veränderungen in Wasserpaketen 201 / Optical spectrophotometry is checked as measuring method for continuous monitoring of waste water quality. The chemical oxygen demand (COD) is used as a central parame-ter for the material assessment of waste water and for its detection in surface waters. The information value about an organic load is increased using an additional fractiona-tion. In a laboratory measurement campaign, data from extinction values of the UV/Vis spectrum and reference values are created (standard analysis parameters and simulated concentrations by using the Activated Sludge Model No. 1). Based on this calibration models for the COD and individual fractions are developed using the regression ap-proach of the partial least squares and their practical suitability is checked in the context of an application example. As a result of this work, calibration models for use in munici-pal wastewater under dry weather conditions, are available. The prediction quality de-creases with increasing differentiation. We advise against further use of the calculated equivalent concentrations for the COD fractions (SS, XS, SI und XI), e.g. as a calibration var-iable for mass transfer models or as a control and regulation variable. The reason for higher measurement uncertainties is identified as insufficient adaptation to the changing wastewater composition during a dry weather day. With an extended data basis, a higher model quality is promised: Standard analysis parameters (COD, CODmf and BOD) are de-termined in wastewater samples before and after respiratory pretreatment in order to be able to rule out substances. In addition, rethinking of static calibration functions for UV/Vis sensors is proposed towards dynamic methods. A generalization of calibration models to other weather conditions, measurement locations or sensors is not recom-mended.:Abbildungen VI Tabellen XIII Abkürzungen XV 1 Einleitung 1 1.1 Motivation 1 1.2 Zielstellung 2 2 Stand der Forschung 5 2.1 Kohlenstoffe 6 2.1.1 Zusammensetzung und Herkunft im häuslichen Abwasser 7 2.1.1.1 Fette 8 2.1.1.2 Proteine 8 2.1.1.3 Tenside 9 2.1.1.4 Phenole 10 2.1.1.5 Kohlenwasserstoffe 10 2.1.2 Fraktionierung von Kohlenstoffverbindungen 11 2.1.2.1 Chemischer Sauerstoffbedarf 12 2.1.2.2 Ansätze zur CSB-Fraktionierung 12 2.1.2.3 Stoffzusammensetzung einzelner CSB-Fraktionen 15 2.1.2.4 Messmethoden zur Bestimmung des CSB 18 2.2 Optische Spektroskopie 20 2.2.1 Grundlagen 20 2.2.1.1 Elektromagnetische Strahlung 20 2.2.1.2 Einordnung der optischen Spektroskopie 21 2.2.1.3 Lichtabsorption 21 2.2.1.4 Chemisch-physikalische Grundlagen 22 2.2.1.5 Mathematische Grundlagen 24 2.2.1.6 Extinktionsmessung 25 2.2.2 Online-Messtechnik 26 2.2.2.1 Sensoren /-hersteller 26 2.2.2.2 Kalibrierung 26 2.2.2.2.1 Kalibrierung der S::CAN MESSTECHNIK GmbH 27 2.2.2.2.2 Unabhängige Analyseverfahren zur Auswertung spektrophotometrischer Messreihen 28 2.2.2.3 Messung 29 2.2.2.3.1 Einstellungen und Voraussetzungen 29 2.2.2.3.2 Qualitative Einflussnahme von Störgrößen auf die spektroskopische Datenerfassung 30 2.2.3 Einsatz in der Siedlungswasserwirtschaft und Hydrologie 31 3 Versuchsdurchführung und Analytik 33 3.1 Messkampagnen 33 3.1.1 Labormessversuche 33 3.1.1.1 Respirationsversuch 34 3.1.1.1.1 Versuchsaufbau zum Respirationsversuch 35 3.1.1.1.2 Betriebshinweise Respirationsversuch 38 3.1.1.2 Verdünnungsversuch 41 3.1.1.2.1 Versuchsaufbau zum Verdünnungsversuch 42 3.1.1.2.2 Betriebshinweise Verdünnungsversuch 43 3.1.2 Feldmessversuch 43 3.1.2.1 Versuchsaufbau zum Feldmessversuch 44 3.1.2.2 Betriebshinweise Feldmessversuch 46 3.2 Abwasserproben: Aufbewahrung und Analytik 47 3.2.1 Konservierung und Probenvorbehandlung 48 3.2.2 Standardisierte Laboranalyseverfahren 49 3.2.2.1 CSB 49 3.2.2.2 Biologischer Sauerstoffbedarf BSBn 50 3.3 Mess- und Regelinstrumente 51 3.3.1 Optischer Multiparameter-Sensor 51 3.3.2 Luminescent Dissolved Oxygen-Sensor (LDO) 53 3.3.3 Peristaltik-Pumpe 54 3.3.4 Dispergierer 54 4 Untersuchungen zur Entwicklung und Anwendung von UV/Vis-Kalibrierungen 55 4.1 Statistische Verfahren zur Kalibrierung 55 4.1.1 Datengrundlage und Methoden 56 4.1.1.1 Datengrundlage 56 4.1.1.2 Multivariate Datenanalyse 57 4.1.1.2.1 Regressionsanalyse 58 4.1.1.2.1.1 Schätzung der Regressionsfunktion 59 4.1.1.2.2 Qualitätsprüfung 61 4.1.1.2.3 Prüfung der Modellprämissen 63 4.1.1.2.4 Multivariate Regressionsanalyse 66 4.1.1.3 Vergleich der Kalibrierverfahren 70 4.1.2 Ergebnisse 70 4.1.2.1 Regressionsansätze für UV/Vis-Kalibrierung 70 4.1.2.1.1 Partial-Least-Squares Regression (PLS-R) 70 4.1.2.1.2 Lasso-Regression 73 4.1.2.1.3 Herstellerkalibrierung (SCAN GmbH) 73 4.1.2.1.3.1 Anwendung der globalen Herstellerkalibrierung 73 4.1.2.1.3.2 Lokal angepasste Herstellerkalibrierung 74 4.1.3 Auswertungen 75 4.1.3.1 Tauglichkeit angewandter Regressionsansätze zur Entwicklung von UV/Vis-Kalibrierfunktionen 75 4.1.3.1.1 Vergleich der Vorhersagequalitäten zwischen Regressionsansätzen und Herstellerkali¬- brierung 75 4.1.3.1.2 Aussagekraft angewandter Regressionsmodelle 77 4.1.3.1.2.1 Regressionsfunktion und -koeffizienten 77 4.1.3.1.2.2 Modellprämissen 78 4.1.3.2 Identifizierung signifikanter WL oder -Bereiche 80 4.2 Fraktionierung von CSB-Verbindungen 81 4.2.1 Datengrundlage und Methoden 82 4.2.1.1 Laborwertmethode 83 4.2.1.2 Modellwertmethode 85 4.2.1.2.1 Respirometrische Messung 86 4.2.1.2.2 Sauerstoffverbrauchsrate 87 4.2.1.2.3 Modellberechnung 89 4.2.1.2.4 Simulationsmethode mit modifiziertem Activated Sludge Modell No. 1 92 4.2.1.2.5 Modellkalibrierung 95 4.2.1.2.6 Datenauswahl 96 4.2.1.3 Lichtabsorptionsmethode 96 4.2.2 Ergebnisse 97 4.2.2.1 Modellwertmethode mit ASM No. 1 97 4.2.2.2 Auswahl von Modelldaten 100 4.2.2.3 UV/Vis-Kalibrierfunktionen 101 4.2.2.3.1 CSB-Fraktionen 101 4.2.2.3.2 Vergleich MW- und LW-Modell 103 4.2.3 Auswertungen 104 4.2.3.1 Tauglichkeit von Simulationsergebnissen aus Modellwertmethode zur Entwicklung von Kalibrierfunktionen 104 4.2.3.2 Abweichende Vorhersagequalitäten zwischen den UV/Vis-Kalibrierfunktionen 106 4.2.3.3 Messunsicherheiten und Modellqualität 107 4.2.3.4 Signifikante Wellenlängen oder -bereiche für einzelne CSB-Fraktionen 109 4.3 Anwendungsbeispiel: Kohlenstoffumsatz entlang einer Fließstrecke 111 4.3.1 Datengrundlage und Methoden 112 4.3.1.1 Einsatz von UV/Vis-Messtechnik 115 4.3.1.1.1 Vergleichbarkeit bei Parallelbetrieb baugleicher Sensoren 115 4.3.1.1.1.1 Versuchsdurchführung 116 4.3.1.1.1.2 Berechnungsansätze 116 4.3.1.1.2 Lokale Kalibrierung 117 4.3.1.1.2.1 Univariat 118 4.3.1.1.2.2 Multivariat 118 4.3.1.2 Kohlenstoffumwandlung und -umsatz innerhalb des Durchflussreaktors 118 4.3.1.2.1 Vorverarbeitung von UV/Vis-Daten 120 4.3.1.2.2 Zeitsynchronisation mithilfe der Fließzeit 120 4.3.1.2.3 Bestimmung von stofflichen Veränderungen in einem Wasserpaket 121 4.3.2 Ergebnisse 122 4.3.2.1 Praxiseinsatz von UV/Vis-Messtechnik 122 4.3.2.1.1 Stabilität und Vergleichbarkeit von Messsignalen bei unterschiedlichen Sensoren 122 4.3.2.1.1.1 Messgüte 122 4.3.2.1.1.2 Sensoranpassung 124 4.3.2.1.2 UV/Vis-Kalibrationsfunktionen 125 4.3.2.1.2.1 Validierung LK-PLS-R 126 4.3.2.1.2.2 Lokale Nachkalibrierung LK-PLS-R 128 4.3.2.1.3 Anwendung entwickelter Kalibrationsmodelle auf Zeitreihen 130 4.3.2.2 Kohlenstoffumsatz 131 4.3.3 Auswertungen 135 4.3.3.1 Tauglichkeit von UV/Vis-Messtechnik für den Einsatz in der Kanalisation 135 4.3.3.1.1 Vorhersagegenauigkeit von Kalibrationsfunktionen 135 4.3.3.1.2 Abweichende Messergebnisse der Extinktion von einzelnen Sensoren 135 4.3.3.2 Veränderungen in den Konzentrationen einzelner Kohlenstofffraktionen entlang der Fließstrecke 136 5 Diskussion 139 6 Ausblick 151 7 Zusammenfassung 153 8 Literaturverzeichnis 157 A Anhang 171 A.1 Respirationsversuche CSB-Fraktionen 171 A.1.1 Quellcode - CSB-Fraktionierung 171 A.1.2 Respirationsversuche CSB-Fraktionen 175 A.1.3 Quellcode - PLS-Regression 178 A.1.4 UV/Vis-Kalibrierung - CSB-Fraktionen 180 A.1.5 Modellgüte 183 A.1.6 Modellprämissen 184 A.2 Feldmesskampagne 188 A.2.1 Sensorkompensation 188 A.2.2 Korrelationsplots 189 A.2.2.1 Validierung der Kalibrationsmodelle 189 A.2.2.2 Nachkalibrierung der Kalibrationsmodelle 192 A.2.2.2.1 univariat 192 A.2.3 Stoffliche Veränderungen in Wasserpaketen 198 A.2.4 Laboranalysen Stoffliche Veränderungen in Wasserpaketen 201
503

<b>Development of a Variable Dilution Olfaction Chamber Coupled with a Proton Transfer Reaction Mass Spectrometer for Evaluation of Human Response to Indoor Emissions from Scented Volatile Chemical Products</b>

Jordan N Cross (16700061) 02 August 2023 (has links)
<p>This study is focused on the design, production, and operation of a controlled environmental olfaction chamber to evaluate human physiological and emotional response to volatile chemical emissions (VCPs) from scented household products in addition to careful characterization of the volatile organic compounds (VOCs) present in these product emissions. Utilizing proton transfer reaction time-of-flight mass spectrometry, the chamber can collect VCP emissions and identify VOCs present to complete an accurate chemical profile of household and common product emissions not previously known. This instrument is one of the first of its kind and will serve as a key element in understanding the relationship between human physical and cognitive health and the built environment.</p>
504

Temporalité des transferts de nutriments dans les bassins versants à algues vertes / Temporality of nutrient transfers in coastal watersheds subjected to green tides

Causse, Jean 30 June 2015 (has links)
En Bretagne, les « marées vertes » sont récurrentes depuis le début des années 70 et occupent une place importante dans le débat public en terme sanitaire, politique et économique. Lors de cette thèse, une large revue bibliographique a été réalisée sur l’export d’azote et une méthodologie innovante a été mise en place afin d’étudier la variabilité spatio-temporelle de l’export de nutriments dans 2 bassins versants à algues vertes à une échelle intra-annuelle et pendant des évènements extrêmes (évènements pluvieux, période touristique de basses eaux,…). Les bassins versants sélectionnés pour les expérimentations de terrain sont l’Ic et le Frémur (Côtes d’Armor). 3 types d’expérimentations ont été réalisées sur ces bassins versants : 1) Des campagnes de prélèvements ponctuels par temps sec et par temps de pluie (32 stations, 27 campagnes) ; 2) des prélèvements automatiques en crue (3 stations, 8 crues) ; et 3) la mesure haute fréquence (2 stations, en continu). Les paramètres hydrologiques et physico-chimiques classiques, les matières en suspension, les spectres UV et toutes les formes de macronutriments (carbone, azote, phosphore) ont été analysés lors de ces expérimentations. Les résultats obtenus confirment pour une part un certain nombre de résultats de la littérature. D’autre part, il met en lumière la relation carbone/nitrates, jusqu’à présent peu étudiée à différentes échelles spatio-temporelles et pendant des évènements pluvieux, qui semble pourtant primordiale dans la compréhension des phénomènes d’export de nitrates à l’échelle de l’année. Enfin, l’analyse de toutes les formes de nutriments révèle l’importance des formes particulaires issues de l’érosion des sols. Ces résultats soulèvent de nombreuses questions de recherche qui mériteraient un approfondissement afin d’améliorer la connaissance des transferts de nutriments dans les bassins versants et prioriser les actions de remédiations. Les perspectives de ce travail sont à la fois scientifiques et pratiques. Au niveau scientifique, les efforts de recherche sur la relation carbone/nitrate et l’identification de la fraction de carbone organique assimilable par les organismes dénitrifiants doivent être poursuivis. De même, l’amélioration des connaissances sur l’export de nutriments en crue passe par l’identification précise des sources de nutriments particulaires pendant les crues printanières. Au niveau pratique, il doit contribuer à l’amélioration des pratiques agricoles, à la reconnaissance de l’intérêt des zones humides naturelles et à l’amélioration des types de traitement utilisés par les stations d’épuration. Les résultats obtenus lors de cette étude devraient notamment être mis en relation avec la dynamique des nutriments observée dans l’estran pendant la période de développement des algues vertes. Enfin, un effort d’amélioration de l’accès à certains type de données sur les bassins versants est nécessaire afin d’améliorer la compréhension des transferts de nutriments. / In Brittany (Western France), "green tides" are recurrent since the early 70s and have an important place in public debate in health, political and economic terms. In this thesis, a wide bibliographic review was performed on the export of nitrogen, and an innovative methodology has been set up to study the spatial and temporal variability of nutrient export in two coastal watersheds on an intra-annual basis and during extreme events (rainfall events, tourist periods of low water, ...). Watersheds selected for the field experiments are Ic and Frémur (Côtes d'Armor). 3 types of experiments were performed on these watersheds: 1) Campaigns of grab samples by dry and wet weather (32 stations, 27 campaigns); 2) automatic sampling during floods (3 stations, 8 floods); and 3) high frequency measurement (2 stations, continuous). Conventional hydrological and physicochemical parameters, suspended solids, UV spectra and all forms of macronutrients (carbon, nitrogen, phosphorus) were analyzed during these experiments. The results confirm in part a number of results of the literature. Furthermore, it highlights the relationship carbon / nitrates far little studied at different spatial and temporal scales and during rainfall events, which however seems to be crucial in understanding of nitrate export. Finally, the analysis of all forms of nutrients reveals the importance of particulate forms from soil erosion. These results raise many research questions that merit further development in order to improve knowledge on nutrient transfers in watersheds and prioritize remediation actions. The prospects of this work are both scientific and practical. At the scientific level, research efforts on the relationship carbon / nitrate and identification of the assimilable fraction of organic carbon by denitrifying organisms must be continued. Similarly, the knowledge on nutrient export must be improved through the precise identification of particulate nutrient sources during the spring floods. On a practical level, it should contribute to the improvement of agricultural practices, the recognition of the interest of natural wetlands and improvement of the types of treatment used by treatment plants. The results obtained in this study should in particular be linked to the dynamics of nutrients in the foreshore observed during the development of green algae. Finally, an effort to improve access to certain types of data on watersheds is needed to improve understanding of nutrient transfers.

Page generated in 0.0929 seconds