• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1810
  • 563
  • 156
  • 7
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 2544
  • 1138
  • 541
  • 434
  • 366
  • 355
  • 302
  • 264
  • 238
  • 214
  • 205
  • 185
  • 182
  • 179
  • 178
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Détection par spectrométrie en réflectance diffuse de colonies microbiennes endolithiques

Dumas, Stéphane 13 April 2018 (has links)
Sur Terre, ce sont dans les vallées sèches de l'Antarctique où l'on retrouve des conditions s 'approchant le plus de la planète Mars. Protégées du gel de la séch eresse et des rayons ultraviolets, les colonies bactériennes endolithiques constituent près de la moitié de la biomas"se de ces régions arides. Cette situation laisse présager qu'il pourrait en être de même sur la planète Mars. Le défi consiste à détecter ces colonies, car souvent aucun signe visible ne laisse présager leur présence. De plus, le forage des pierres risque de contaminer, ou pire encore, de détruire de précieux spécimens. L'approche proposée utilise la spectroscopie infrarouge afin de repérer la signature spectrale des colonies microbiennes. Le but de ce projet est d 'une part de vérifier la possibilité de détecter des microorganismes dans des échantillons de roches. La deuxième partie du projet est de développer une technique d'analyse des spectres afin d'isoler les marqueurs biologiques dans lesdits spectres de roches. La première partie fut accomplie avec l'aide d'échantillons de roches provenant de deux sites différents (Nunavut et Guelph). La méthode est décrite dans le chapitre 2. "La deuxième partie fut réalisée avec différents outils mathématiques tels que la méthode de corrélation et l'analyse en composantes principales (ACP, chapitre 3). Les résultats . montrent que la technique ACP fonctionne tant pour identifier le contenu minéral des . roches que pour isoler les spectres susceptibles de contenir des matières organiques. Toutefois, il n'est pas possible d 'identifier le type de molécule organique contenue dans les échantillons. La technique ACP fut également testée sur des échantillons d'Antarctique (chapitre 4) et le résultat s'avère positif. Alors que pour les spectres de roches martiennes provenant des sondes MER, les résultats sont non concluants voir négatif.
342

Étude spectroscopique de l'isométrie de rotation dans les éthanols, 2. substitués

Schneider, Michel 30 January 2019 (has links)
Montréal Trigonix inc. 2018
343

Dual Comb Spectrometry of Solid Samples

Skehan, Joseph 19 September 2019 (has links)
L’objectif de ce mémoire est de partager les connaissances obtenues lors de mon travail sur la spectroscopie à deux peignes et ses applications sur les matériaux solides. Pour y parvenir, certain sujets connexes sont élaborés. Dans l’ordre, on y aborde la physique des lasers, le verrouillage et la stabilisation des modes, l’interférométrie générale et celle des peignes, ainsi que la modification des impulsions des peignes de fréquence en utilisant l’ptique non-linéaires. On présente ensuite deux études expérimentales. La première porte sur la combinaison de la spectroscopie à deux peignes avec la technique pompe-sonde et la seconde sur l’analyse de la variance baseline en contexte de la spectroscopie à deux peignes. / The goal of this memoire is to communicate my work regarding the application of dual comb spectroscopy to materials beyond traditional gas phase spectroscopy. A variety of topics required to understand my work are presented, such as general laser physics, mode-locking, stabilization of the repetition rate and carrier envelope offset, interferometry, dual comb spectroscopy, and the modification of said combs via non-linear optics. Two experimental studies are presented as well. These include the combination of dual comb spectroscopy with the pump-probe technique, as well as an analysis of baseline variance incontext of dual comb spectroscopy.
344

Using surface spectroscopy to help Interpret STM images of chemisorbed molecules : application to the study of the hydrogenation of ketones and a-ketoesters on Pt

Zeng, Yang 24 April 2018 (has links)
Depuis que la haute énantiopureté est nécessaire dans l'industrie pharmaceutique, les études visant à découvrir les mécanismes pour l'hydrogénation énantiosélective de cétones ou céto-esters sur les surfaces, et à rechercher de nouveaux et plus performants catalyseurs asymétriques, sont d'une grande importance. La microscopie à effet tunnel (STM), la spectroscopie infrarouge de réflexion-absorption, la spectroscopie de désorption à température programmée et la spectrométrie de photoélectrons induits par rayons X sont des méthodes performantes facilitant la compréhension des mécanismes de réaction. En plus de nous permettre de comprendre les mécanismes réactionnels, les études peuvent fournir des informations sur la dynamique des réactions en catalyse hétérogène ainsi que sur le développement de la théorie de la fonctionnelle de la densité (DFT) afin de calculer des interactions faibles dans les processus de surface. D’autres parts, les calculs DFT fournissent une aide essentielle à l'interprétation des données de STM et spectroscopie de surface. Dans cette thèse, certains cétones et céto-esters sur la surface de platine sont étudiées par les techniques sophistiquées mentionnées ci-dessus. Mes études démontrent que la combinaison de l'utilisation de la spectroscopie de routine, des nanotechnologies et de nombreux calculs élaborés, est une méthode efficace pour étudier les réactions à la surface car ces techniques explorent les différents aspects de la surface ainsi que s’entraident mutuellement lors de certaines interprétations. / Since high enantiopurity is required in the pharmaceutical industry, studies aimed at discovering the mechanisms for the enantioselective hydrogenation of ketones or keto-esters on surfaces and at successfully seeking out new or better performing asymmetric catalysts are of great significance. Scanning tunneling microscopy (STM), reflection absorption infrared spectroscopy (RAIRS), temperature-programmed desorption spectroscopy (TPD) and X-ray photoelectron spectroscopy (XPS) are powerful methods to facilitate an understanding of the reaction mechanisms. In addition to insight on reaction mechanisms, the studies can contribute information on reaction dynamics in heterogeneous catalysis and on the development of density functional theory (DFT) methods to compute weak interactions in surface processes. In turn, DFT calculations provide critical help in the interpretation of STM and surface spectroscopy data. In this thesis, some ketones and keto-esters on platinum surface are studied by the above mentioned sophisticated techniques. My studies demonstrate that the combination of using routine spectroscopy, nanotechnology, and state of the art calculations is an effective method to study reactions on surface as they explore different aspect of surface, and mutually help each other for some interpretations.
345

Nouvelle technique d'optimisation de la détection moléculaire à base d'un spectromètre microscope-FTIR

Landari, Hamza 02 February 2024 (has links)
L'identification et la quantification des espèces transmise aux cellules nerveuses lors des échanges moléculaires entre les neurones sous la forme de neurotransmetteurs nous permettent de mieux comprendre certains fonctionnements du cerveau et certaines maladies neurodégénératives. À son tour, cette compréhension nous permettrait à long terme d'améliorer la qualité de vie des patients souffrants de ces maladies. D'un autre côté, la composition des aliments sous la forme de valeurs nutritionnelles nous permet de mieux connaître l'effet de la consommation de ces aliments sur la santé afin d'éviter de graves complications. De plus, la connaissance de cette composition nous permet d'améliorer la qualité de ces produits. Pour extraire la composition et la concentration des neurotransmetteurs dans le cerveau ou les valeurs nutritionnelles des aliments, il faut développer des outils d'analyse chimique et moléculaire très précise et sélective. L'analyse chimique d'un échantillon biologique nécessite deux étapes : (1) l'échantillonnage du liquide biologique et (2) l'étude de la composition de l'échantillon. Cette dernière étape consiste à identifier/quantifier la composition moléculaire des échantillons et à caractériser les propriétés chimiques de ces derniers. Cette étape nécessite donc le développement des instruments et des algorithmes de détection moléculaire avancés qui permettent de déterminer les concentrations physiologiques des neurotransmetteurs et d'autres molécules biologiques. Dans cette étude, nous nous sommes intéressés aux neurotransmetteurs suivants : dopamine hydrochloride, acide L-ascorbique, acétylcholine chloride, y-aminobutyrique, glycine et acide L-glutamique et aux molécules de sucre, incluant le glucose, le fructose et le saccharose. Le choix de l'instrument à utiliser dépend de plusieurs critères, dont les caractéristiques de l'échantillon (viscosité, volume parmi d'autres). Dans le cadre de cette thèse de doctorat, nous examinons les performances de plusieurs méthodes et instruments de détection, soit l'électrochimie, la spectroscopie d'impédance et la spectroscopie UV/Visible et infrarouge (IR), pour la détection de différents types de molécules dans des échantillons aqueux. Par la suite, nous proposons une nouvelle approche d'analyse des échantillons aqueux basée sur la spectroscopie IR. Nous nous intéressons plus particulièrement au spectromètre microscope-FTIR qui nous permet d'effectuer des analyses spectroscopiques IR et de visualiser la distribution spatiale et moléculaire dans l'échantillon. Cependant, le spectromètre microscope-FTIR, dans sa configuration standard, ne permet pas l'analyse des échantillons aqueux à cause de la forte absorption des rayonnements IR par les molécules d'eau. Pour résoudre ce problème, nous avons proposé un nouveau système microfluidique de contrôle et de manipulation des liquides qui a été intégré au spectromètre microscope-FTIR pour analyser des échantillons aqueux. Le nouveau système proposé consiste en un module de réflexion, une couche hydrophobe et un module microfluidique. Le module de réflexion est maintenu à une température élevée pour l'évaporation rapide du solvant. La couche hydrophobe permet à son tour de confiner l'échantillon en un espace restreint pour avoir une distribution plus uniforme des molécules sur la surface du substrat. Ce nouveau système nous a permis d'identifier et de quantifier différents types de molécules tels que les neurotransmetteurs et les molécules de sucres, dont le glucose, le fructose et le saccharose. La limite de détection que nous avons pu atteindre avec notre système est de 10 µMolaire pour les neurotransmetteurs, de 3 mMolaire pour le glucose et le fructose et de 1 mMolaire pour le saccharose. En plus, nous avons proposé un nouvel algorithme pour une identification automatique des neurotransmetteurs par le microscope FTIR. À travers cet algorithme, nous avons pu identifier, dans des solutions synthétiques (homogènes et hétérogènes), les six neurotransmetteurs suivants : la dopamine hydrochloride, l'acide L-ascorbique, l'acétylcholine chloride, l'y-aminobutyrique, la glycine et l'acide L-glutamique. La précision de la détection du nouvel algorithme est de 75% à 100% pour les six neurotransmetteurs que nous avons étudiés dans 36 échantillons homogènes et 45 échantillons hétérogènes. / The identification and quantification of species transmitted/received by nerve during molecular exchanges between neurons in the form of neurotransmitters allow us to better understand certain brain functions and certain neurodegenerative diseases. This understanding helps us in the long term to improve the quality of life of patients suffering from these diseases. Also, the composition of foods and their nutritional values, allows us to better understand the effect of foods consumption on human health to avoid severe complications and to improve food quality. To extract the composition and concentration of neurotransmitters in the brain and concentration of sugar for example in foods, it is necessary to develop very precise and selective chemical and molecular analysis tools. Indeed, chemical analysis of a biological sample requires two steps: (1) sampling the biological fluid and (2) studying the composition of the sample. The second step consists of identifying / quantifying the molecular composition of the samples and characterizing the its chemical properties. Therefore, this step requires the development of advanced molecular detection instruments and algorithms that make it possible to determine the physiological concentrations of neurotransmitters and other biological molecules. In this study, we were interested in the following neurotransmitters: dopamine hydrochloride, L-ascorbic acid, acetylcholine chloride, y-aminobutyric, glycine and L-glutamic acid and in sugar molecules including glucose, fructose, and sucrose. The selection of the detection methods/instruments depends on several criteria such as the characteristics of the sample (viscosity, volume among others). In the context of this PhD thesis, we are investigating the performance of several detection methods/instruments such as electrochemistry, impedance spectroscopy and UV / Visible and infrared (IR) spectrometry, for the detection of different types of molecules in aqueous samples. Then, we propose a new chemical analysis approach of aqueous samples based on IR spectrometry. We are particularly interested to microscope-FTIR spectrometer which allows us to perform IR spectroscopic analysis and to visualize the spatial molecular distribution in the analyzed sample. However, the microscope-FTIR spectrometer, in its standard configuration, does not allow the analysis of aqueous samples due to the high absorption of IR radiation by water molecules. To address this problem, we proposed a new microfluidic system for liquid control and handling, which has been integrated with the microscope-FTIR spectrometer to analyze aqueous samples. The new proposed system consists of a reflection module, a hydrophobic layer, and a microfluidic system. The reflection module is heated in order to ensure rapid evaporation of the solvent. The hydrophobic layer allows the sample to be confined in a small area to ensure more uniform distribution of molecules on the surface of the substrate. This new system allowed us to identify and quantify different types of molecules such as neurotransmitters and sugar molecules. The reached detection limit with our system is 10 µM for neurotransmitters, 3 mM for glucose and fructose and 1 mM for sucrose. In addition, we proposed a new algorithm for automatic molecular identification by the FTIR microscope spectrometer. Using this algorithm, we were able to identify the following six neurotransmitters: dopamine hydrochloride, L-ascorbic acid, acetylcholine chloride, y-aminobutyric, glycine and L-glutamic acid, in synthetic solutions (homogeneous and heterogeneous). Finally, the detection accuracy of the new algorithm is 75% to 100% for the six neurotransmitters we studied, in 36 homogeneous and 45 heterogeneous samples.
346

Caractérisation et validation d'un découpeur d'images

Bayard, Caleb 10 February 2024 (has links)
Les découpeurs d'images sont devenus des équipements essentiels dans le domaine de l'astronomie, particulièrement pour la spectroscopie intégrale de champ. La conception et l'usinage des découpeurs d'images, principalement du miroir découpeur qui en est la pièce centrale, est complexe et présente de nombreux défis techniques. Suivant sa fabrication, la caractérisation des découpeurs d'images est donc capitale afin de s'assurer que le dispositif rencontre les spécifications établies. Dans le cadre du développement de GIRMOS¹ (un spectrographe infrarouge multi-objets destiné aux télescopes jumeaux de 8,1 m de l'Observatoire Gemini), qui emploie la technologie des découpeurs d'images, il devient ainsi primordial de mettre en place une procédure pour en assurer la caractérisation. Dans ce contexte, l'objectif de ce projet de maîtrise est d'élaborer une méthodologie permettant de caractériser et de valider des découpeurs d'images. Les travaux présentés dans ce mémoire détaillent les concepts entourant les découpeurs d'images avancés et mettent de l'avant l'ensemble des tests nécessaire à la caractérisation du miroir découpeur. De plus, le développement d'un outil de caractérisation pour les pupilles intermédiaires, soit un banc de tests, y est décrit. Afin de valider la méthodologie établie, la série de tests métrologiques est menée sur un prototype de miroir découpeur. En comparant les résultats expérimentaux avec les résultats des simulations et la théorie, il a été possible de conclure que la méthodologie établie permet de caractériser partiellement le découpeur d'images. En effet, des améliorations restent à faire sur le banc de tests afin d'augmenter la précision de ce dernier. De surcroît, certains tests identifiés dans la méthodologie n'ont pu être mis en œuvre notamment dû au fait que les miroirs pupille et les miroirs fente n'avaient pas encore été fabriqués. Ces tests n'ayant pu être menés, il n'est pas possible de conclure que la méthodologie permet de valider le découpeur d'images menant à une l'atteinte partielle de l'objectif. / Image slicers have become essential equipment in the field of astronomy, particularly for Integral Field Spectroscopy. The design and manufacture of an image slicer, mainly the slicer mirror, which is the central part, is complex and presents many technical challenges. Following its fabrication, the characterization of an image slicer is therefore essential to ensure that the device meets the established specifications. As part of the development of GIRMOS² (a multi-object infrared spectrograph for twin 8.1 m telescopes of the Gemini Observatory), which uses image slicer technology, it becomes essential to set up a procedure to ensure its characterization. In this context, the objective of this master's project is to develop a methodology to characterize and validate image slicers. The work presented in this master's thesis details the concepts surrounding advanced image slicers and highlights all the tests necessary for the characterization of slicer mirrors. In addition, the development of a characterization tool for intermediate pupils, namely a test bench, is described therein. To validate the established methodology, a series of metrological tests are carried out on a slicer mirror prototype. By comparing the experimental results with the results of the simulations and the theory, it was possible to conclude that the established methodology allows to partially characterize the image slicer. Indeed, improvements remain to be made on the test bench to increase the accuracy of the latter. In addition, certain tests identified in the methodology could not be implemented, in particular since the pupil mirrors and the slit mirrors had not yet been manufactured. As these tests could not be carried out, it is impossible to conclude that the methodology allows to validate the image slicer leading to a partial achievement of the objective.
347

Une plate-forme sans fil pour electrochimique spectroscopie d'impédance

Ghaffari, Seyed Alireza 23 April 2018 (has links)
Avec l’émergence soutenue de capteurs et de dispositifs électrochimiques innovants, la spectroscopie d'impédance électrochimique est devenue l'un des outils les plus importants pour la caractérisation et la modélisation de la matière ionique et de l'interfaçage des capteurs. La capacité de détecter automatiquement, à l’aide de dispositifs électrochimiques peu couteux, les caractéristiques physiques et chimiques de la matière ionique ouvre une gamme d’application très variée pour la compréhension et l’optimisation des procédés ou interviennent les processus électrochimiques. Cette thèse décrit le développement d’une plate-forme microélectronique miniaturisée, connectée, multiplexée, et à faible coût pour la spectroscopie d'impédance diélectrique (SID) conçue pour les mesures électrochimiques in-situ et adaptée aux architectures de réseau sans fil. La plate-forme développée durant ce travail de maitrise a été testée et validée au sein d’une maille ZigBee et a été en mesure d'interfacer jusqu'à trois capteurs SID en même temps et de relayer l'information à travers le net Zigbee pour l'analyse de données et le stockage. Le système a été construit à partir de composants microélectroniques disponibles commercialement et bénéficie des avantages d'une calibration système on-the-fly qui effectue la calibration du capteur de manière aisée. Dans ce mémoire de maitrise, nous rapportons la modélisation et la caractérisation de senseurs électrochimiques de nitrate; notamment nous décrivons la conception microélectronique, la réponse d'impédance de Nyquist, la sensibilité et la précision de la mesure électrochimique, et les résultats de tests de la plate-forme pour les applications de spectroscopie d'impédance relatives à la détection du nitrate, de la détection de la qualité de l'eau, et des senseurs tactiles. / The emergence of the various applications of electrochemical sensors and devices, electrochemical impedance spectroscopy became one of the most important tools for characterizing and modeling of the material and interfacing the sensors. The ability to sense in an automatic manner enables a wide variety of processes to be better understood and optimized cost-effectively. This thesis describes the development of a low-cost, miniaturized, multiplexed, and connected platform for dielectric impedance spectroscopy (DIS) designed for in-situ measurements and adapted to wireless network architectures. The platform has been tested and used as a DIS sensor node on a ZigBee mesh and was able to interface up to three DIS sensors at the same time and relay the information through the Zigbee net for data analysis and storage. The system was built from commercial microelectronics components and benefits from an on-the-fly calibration system that makes sensor calibration easy. The thesis reports characterizing and modeling of two electro-chemical devices (i.e. nitrate sensor and optically-transparent electrically-conductive glasses) and also describes the microelectronics design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the testing of the platform for in-situ dielectric impedance spectroscopy applications pertaining to fertilizer sensing, water quality sensing, and touch sensing.
348

Dual Comb Spectrometry of Solid Samples

Skehan, Joseph 18 October 2019 (has links)
L’objectif de ce mémoire est de partager les connaissances obtenues lors de mon travail sur la spectroscopie à deux peignes et ses applications sur les matériaux solides. Pour y parvenir, certain sujets connexes sont élaborés. Dans l’ordre, on y aborde la physique des lasers, le verrouillage et la stabilisation des modes, l’interférométrie générale et celle des peignes, ainsi que la modification des impulsions des peignes de fréquence en utilisant l’ptique non-linéaires. On présente ensuite deux études expérimentales. La première porte sur la combinaison de la spectroscopie à deux peignes avec la technique pompe-sonde et la seconde sur l’analyse de la variance baseline en contexte de la spectroscopie à deux peignes. / The goal of this memoire is to communicate my work regarding the application of dual comb spectroscopy to materials beyond traditional gas phase spectroscopy. A variety of topics required to understand my work are presented, such as general laser physics, mode-locking, stabilization of the repetition rate and carrier envelope offset, interferometry, dual comb spectroscopy, and the modification of said combs via non-linear optics. Two experimental studies are presented as well. These include the combination of dual comb spectroscopy with the pump-probe technique, as well as an analysis of baseline variance incontext of dual comb spectroscopy.
349

Étude de la soie par spectroscopie infrarouge à réflexion totale atténuée

Boulet-Audet, Maxime 17 April 2018 (has links)
Tableau d’honneur de la Faculté des études supérieures et postdoctorales, 2009-2010 / Les propriétés mécaniques de la soie sont supérieures à toute autre protéine fibreuse et n'ont jamais été surpassées par aucun matériau synthétique. Une meilleure compréhension de la structure moléculaire de la soie et des changements qui s'opèrent pendant, avant et après le filage est requise pour maîtriser sa conception. La spectroscopic infrarouge fut utilisée pour étudier la structure moléculaire des fibres microscopiques de soie. Afin d'éviter les problèmes liés à l'acquisition de spectres par transmission, la réflexion totale atténuée (ATR) a été utilisée. Avec un nouveau montage permetant la rotation de l'échantillon, l'orientation et la conformation d'une seule fibre de soie furent quantifiées pour la première fois par spectroscopic infrarouge. Des simulations spectrales ont été effectuées pour trouver les conditions expérimentales minimisant ces effets optiques nuisibles à l'interprétation des spectres. Les constantes optiques de la soie native du ver à soie ont été déterminées pour la première fois afin d'exécuter des simulations spectrales avec des paramètres variables. Ses simulations ont également permis d'estimer l'amplitude des effets optiques observés pour tout autre système.
350

Conception d'un accessoire pour l'automatisation du balayage de mesures par spectrométrie

Joly, Maxime 02 February 2024 (has links)
La spectrométrie est utilisée pour étudier la composition chimique de la matière. Elle aide les chercheurs à étudier et comprendre tout ce qui nous entoure. Plusieurs technologies de spectrométrie sont offertes sur le marché, mais elles ne permettent d’effectuer des mesures que sur un échantillon à la fois. Si un chercheur souhaite comparer l’évolution de plusieurs échantillons sur un temps donné dans un environnement précis, aucune technologie offerte présentement sur le marché ne le permet. L’accessoire développé dans le cadre de ce projet de maîtrise a comme objectif d’ajouter un paramètre dimensionnel à la spectrométrie infrarouge à transformée de Fourier (FTIR). Une fente déplacée linéairement sous un cristal à réflectance totale atténuée (ATR) permet de sélectionner précisément la région de l’échantillon à mesurer. L’accessoire complètement automatisé offre une solution compacte, rapide et abordable pour faire des mesures complexes en spectrométrie. Le prototype de l’accessoire a été développé durant ce projet de maîtrise. Ses performances, notamment en ce qui concerne la précision du positionnement de la fente, sont analysées et optimisées. Une simulation du parcours de la lumière dans le cristal ATR permet de reproduire et de comprendre les premières mesures effectuées avec l’accessoire. Elle permet également de définir la précision requise pour soutirer les performances optimales du cristal ATR utilisé. Des recommandations découlant de l’analyse des premières mesures et de la simulation seront prises en compte pour l’optimisation future de l’accessoire. / Spectrometry is used to study the chemical composition of matter. It helps researchers study and understand everything around us. Several spectrometry technologies are available on the market, but they only allow measurements to be taken on one sample at a time. If a researcher wishes to compare the evolution of several samples over a given time in a specific environment, no technology currently available on the market allows it.The accessory developed as part of this master’s project aims to add a dimensional parameter to Fourier transform infrared spectrometry (FTIR). A linearly displaced rectangular aperture placed under an attenuated total reflectance (ATR) crystal allows precise selection of the region of the sample to be measured. The fully automated accessory offers a compact, fast and affordable solution for making complex spectrometry measurements. The accessory prototype was developed during this master’s project. Its performances, in particular regarding the precision of the positioning of the aperture, is analyzed and optimized. A simulation of the path of light in theATR crystal makes it possible to reproduce and understand the first measurements made with the accessory. Italso makes it possible to define the precision required to extract optimum use of the ATR crystal used. Recommendations from the analysis of the first measurements and the simulation will be taken into account forfuture optimization of the accessory

Page generated in 0.0523 seconds