• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da dureza e da resistência à compressão de resinas compostas para dentes posteriores após a imersão em água destilada. Efeito da aplicação de selante superficial /

Cruz, Carlos Alberto dos Santos. January 2001 (has links)
Resumo: Novos compósitos têm surgido no mercado especificamente destinados à confecção de restaurações estéticas posteriores. Entretanto, embora tais materiais apresentem resultados iniciais animadores, há a necessidade de comprovações adicionais para que possam ser utilizados com segurança. Resinas compostas posteriores são submetidas a estresses complexos de compressão e abrasão durante a mastigação e a aplicação de selantes superficiais tem sido relatada como forma de aumentar a resistência ao desgaste destes materiais. O presente trabalho teve como propósito avaliar a dureza e a resistência à compressão das resinas compostas Alert (Jeneric/Pentron), Ariston (Vivadent), Definite (Degussa), P60 (3M), Solitarie (Kulzer), Surefil (Dentsply) e Z100 (3M) após 90 dias de imersão em água destilada, recobertas com selante Protect It (Jeneric/Pentron) e submetidas à ciclagem mecânica (10.000 ciclos, 600N, 5Hz). Os ensaios de dureza (n=8) foram realizados em aparelho Wolpert, com diamante Vickers e peso de 50gf aplicado por 30 segundos, antes e após períodos de imersão de 30, 60 e 90 dias. Os ensaios de resistência à compressão (n=8) foram realizados somente após 90 dias, em corpos-de-prova cilíndricos medindo 8mm de altura por 4mm de diâmetro. Apenas os espécimes destinados à compressão foram ciclados mecanicamente. Os ensaios foram realizados em máquina MTS 810, equipada com célula de carga de 10kN (ciclagem) e 100kN (compressão) e velocidade de 0,5mm/min. Após análise de variância (p<0,05), os resultados mostraram, previamente à imersão, maiores valores de dureza para os materiais Z100 (74,253VHN) e Ariston (71,308VHN). A seguir, com valor semelhante à resina Ariston, mas inferior à resina Z100, apresentou-se o material Surefil (69,969VHN)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: New materials have been specifically indicated to direct posterior esthetic restoration. Although the clinical results seem to be satisfactory, at first, they haven't been enough to warrant restoration longevity. Posterior composite resins are subjected to compressive and abrasive stresses and surface penetrating sealants have been indicated in order to increase resins' wear resistance. The aim of this study was to evaluate hardness and compressive strength of posterior composite resins (Alert/Jeneric-Pentron, Ariston/Vivadent, Definite/Degussa, P60/3M, Solitarie/Kulzer, Surefil/Dentsply and Z100/3M), treated with a surface sealant (Protect It/Jeneric-Pentron), after 90 days of destiled water immersion and subjected at 10,000 stress cycles (600N, 5Hz). The hardness tests (n=8) were conducted on Wolpert equipment, using a Wickers diamond and 50gf load applied for 30 seconds before and after immersion for 30, 60 and 90 days. The compressive tests (n=8) were conducted after 90 days on MTS-810 machine with load cell of 10kN (cycling) and 100kN (compressive strength) and crosshead speed of 0.5 mm/min in samples 4mm of diameter and 8mm height. Before immersion (Anova, p<0,05), Z100 (74.253VHN) and Ariston (71.308VHN) showed the highest hardness. Surefil (69.969VHN) was similar to Ariston, but significantly lower than Z100. Alert (66.138VHN) was lower than Surefil, but higher than P60 (62.833VHN) and Definite (61.302VHN). Solitaire (46.609VHN) exhibited the lower hardness. After immersion, there was a significant decrease in hardness for almost all materials (Ariston, 97%; Definite, Solitaire and Surefil, 26%; Z100, 12% and Alert, 8%). Surface penetrating sealant had no effect on hardness values. Without cyclic loading (Anova, p<0,05), Z100 (336.275MPa), Alert (334.350MPa), P60 (331.000MPa)... (Complete abstract, click electronic access below)
2

Efeito in situ do clareamento caseiro e subseqüentes tratamentos de superfície na cor e rugosidade superficial de resinas compostas / In situ effect of home bleaching and subsequent surface treatment on color and surface roughness of composite resins

Garcia, Lourdes Maria González 13 April 2012 (has links)
Este estudo avaliou in situ a susceptibilidade ao manchamento de duas resinas compostas Z350 XT® (M1) e Z250® (M2), ambas da 3M/ESPE por meio da alteração de cor e rugosidade superficial após o uso do agente clareador peróxido de carbamida 16% e subseqüentes tratamentos de superfície. Foram confeccionados 156 corpos-de-prova, n=13 para cada condição experimental. O estudo crossover teve duas fases de 14 dias cada, com um período de washout de 9 dias. Os corpos de prova de cada material foram montados em placas de acetato, distribuídos em 13 voluntários, na região dos segundos pré-molares, primeiros e segundos molares superiores e instalados nos participantes para a realização do tratamento proposto em cada fase. De acordo com aleatorização, 6 voluntários utilizaram na primeira fase do experimento o gel a base de peróxido de carbamida 16% (Home Peroxide, DMC) (CCL) e 7 voluntários o gel placebo (DMC) (SCL) da mesma composição do gel original, porém sem adição do peróxido. Os voluntários aplicaram os géis nos corpos-deprova por 8h/dia, durante 14 dias nas duas fases do experimento. Após o clareamento os corpos de prova foram submetidos aos seguintes tratamentos de superfícies: polimento com discos Sof Lex (3M/ESPE) (TR1), sem tratamento de superfície (TR2) e a aplicação do selante de superfície Biscover (BISCO) (TR3) e subseqüentemente foram imersos em vinho tinto. As leituras de cor foram realizadas 24 horas após o clareamento (L0) e 24 horas após tratamento de superfície e manchamento (L1), já para a rugosidade superficial foram realizadas 3 leituras: 24 horas após a confecção dos corpos-de-prova (L0), 24 horas após o clareamento (L1) e 24 horas após tratamento de superfície e manchamento (L2). Os dados foram submetidos ao teste ANOVA e Tukey. Os resultados mostraram que: a) O Clareamento não determinou diferença estatisticamente de &Delta;E*, no entanto, foi significante para &Delta;L*, &Delta;a* e &Delta;b*; b) A resina M1 apresentou maior média de &Delta;E* que a M2; c) Os tratamentos de superfície com Sof Lex e Biscover apresentaram valores de &Delta;E* estaticamente semelhantes, enquanto que o sem tratamento apresentou diferença estatisticamente significante entre os materiais; d) O clareamento não teve efeito significante na rugosidade superficial de resinas estudadas; e) M1 e M2 apresentaram maior rugosidade superficial em L2 que em L0 e L1; f) TR3 apresentou maior média de rugosidade superficial que TR1 e TR2. Conclui-se que: a resina Z350 XT apresentou maior alteração de cor que a Z250; o clareamento aplicado no tempo estabelecido neste estudo não promoveu alteração de cor e não influenciou na rugosidade superficial nas resinas compostas estudadas; e as resinas compostas estudadas apresentaram maior rugosidade após o Tratamento de superfície associado ao manchamento com vinho tinto; o selante de superfície Biscover apresentou maior rugosidade superficial para a resina Z250. / This study evaluated in situ the staining susceptibility of different composite resins (Z350 XT ® (M1) and Z250 ® (M2), both of 3M/ESPE) by color change and surface roughness after the aplication of 16% carbamide peroxide bleaching gel and subsequent surface treatments and staining with red wine. One hundred fifty-six specimens were fabricated where n=13 were per experimental condition. The study had two phases of 14 days each, with a washout period of 9 days between them. The specimens of each material fixed into custom fabricated trays in 13 volunteers in the region of the second premolars, first and second molars and installed in the participants to carry out for the proposed treatment at each stage. According randomly 6 volunteers used in the first stage of the experiment the 16% peroxide carbamide gel (Home Peroxide, DMC) (CCL) and 7 volunteers used placebo gel (DMC) (SCL) that it was the same composition original gel, but without addition of peroxide. The volunteers applied the gel on the top of the specimens for 8h/day for 14 days during the two phases of the experiment. After bleaching treatment the specimens were subjected to the following surface treatments: polishing with Sof Lex (3M/ESPE) (TR1), without surface treatment (TR2) and the application of the sealant surface Biscover (BISCO) (TR3) and subsequently were immersed in red wine. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the gel, so that all used both gels. Finishing the second phase, the specimens were subjected to surface treatment and subsequent staining. The color change were measured 24 hours after bleaching in situ (L0) and 24 hours after surface treatment and red wine stains (L1) and the surface roughness were measured immediately after 24 hours of preparation of the specimens (L0) 24 hours after the in situ bleaching treatment (L1) and 24 hours after surface treatment and staining with red wine (L2). Data were submitted to ANOVA and Tukey. The results showed that: a) The bleaching showed no statistically significant difference for &Delta;E *, however, was significant for all parameters &Delta;L*, &Delta;a* and &Delta;b*; b) The composite 350 XT presented higher average of color change (&Delta;E * ) than Z250; c) The surface treatments with Sof Lex and Biscover had values of &Delta;E* statistically similar, while no treatment surface showed a statistically significant difference between the materials; d) Bleaching had no significant effect on surface roughness of composite resins; e) The composites showed higher values of surface roughness in L2 than in L1 and L0. f) TR3 demonstrated higher average of surface roughness than TR1 and TR2. It was concluded that bleaching did not affect the color change and surface roughness in the composites studied, the surface treatment had no effect clinically significant for the susceptibility to staining, and the composites studied had higher surface roughness when subjected to treatment surface staining associated with red wine and the surface sealant Biscover showed higher surface roughness for resin Z250.
3

Efeito in situ do clareamento caseiro e subseqüentes tratamentos de superfície na cor e rugosidade superficial de resinas compostas / In situ effect of home bleaching and subsequent surface treatment on color and surface roughness of composite resins

Lourdes Maria González Garcia 13 April 2012 (has links)
Este estudo avaliou in situ a susceptibilidade ao manchamento de duas resinas compostas Z350 XT® (M1) e Z250® (M2), ambas da 3M/ESPE por meio da alteração de cor e rugosidade superficial após o uso do agente clareador peróxido de carbamida 16% e subseqüentes tratamentos de superfície. Foram confeccionados 156 corpos-de-prova, n=13 para cada condição experimental. O estudo crossover teve duas fases de 14 dias cada, com um período de washout de 9 dias. Os corpos de prova de cada material foram montados em placas de acetato, distribuídos em 13 voluntários, na região dos segundos pré-molares, primeiros e segundos molares superiores e instalados nos participantes para a realização do tratamento proposto em cada fase. De acordo com aleatorização, 6 voluntários utilizaram na primeira fase do experimento o gel a base de peróxido de carbamida 16% (Home Peroxide, DMC) (CCL) e 7 voluntários o gel placebo (DMC) (SCL) da mesma composição do gel original, porém sem adição do peróxido. Os voluntários aplicaram os géis nos corpos-deprova por 8h/dia, durante 14 dias nas duas fases do experimento. Após o clareamento os corpos de prova foram submetidos aos seguintes tratamentos de superfícies: polimento com discos Sof Lex (3M/ESPE) (TR1), sem tratamento de superfície (TR2) e a aplicação do selante de superfície Biscover (BISCO) (TR3) e subseqüentemente foram imersos em vinho tinto. As leituras de cor foram realizadas 24 horas após o clareamento (L0) e 24 horas após tratamento de superfície e manchamento (L1), já para a rugosidade superficial foram realizadas 3 leituras: 24 horas após a confecção dos corpos-de-prova (L0), 24 horas após o clareamento (L1) e 24 horas após tratamento de superfície e manchamento (L2). Os dados foram submetidos ao teste ANOVA e Tukey. Os resultados mostraram que: a) O Clareamento não determinou diferença estatisticamente de &Delta;E*, no entanto, foi significante para &Delta;L*, &Delta;a* e &Delta;b*; b) A resina M1 apresentou maior média de &Delta;E* que a M2; c) Os tratamentos de superfície com Sof Lex e Biscover apresentaram valores de &Delta;E* estaticamente semelhantes, enquanto que o sem tratamento apresentou diferença estatisticamente significante entre os materiais; d) O clareamento não teve efeito significante na rugosidade superficial de resinas estudadas; e) M1 e M2 apresentaram maior rugosidade superficial em L2 que em L0 e L1; f) TR3 apresentou maior média de rugosidade superficial que TR1 e TR2. Conclui-se que: a resina Z350 XT apresentou maior alteração de cor que a Z250; o clareamento aplicado no tempo estabelecido neste estudo não promoveu alteração de cor e não influenciou na rugosidade superficial nas resinas compostas estudadas; e as resinas compostas estudadas apresentaram maior rugosidade após o Tratamento de superfície associado ao manchamento com vinho tinto; o selante de superfície Biscover apresentou maior rugosidade superficial para a resina Z250. / This study evaluated in situ the staining susceptibility of different composite resins (Z350 XT ® (M1) and Z250 ® (M2), both of 3M/ESPE) by color change and surface roughness after the aplication of 16% carbamide peroxide bleaching gel and subsequent surface treatments and staining with red wine. One hundred fifty-six specimens were fabricated where n=13 were per experimental condition. The study had two phases of 14 days each, with a washout period of 9 days between them. The specimens of each material fixed into custom fabricated trays in 13 volunteers in the region of the second premolars, first and second molars and installed in the participants to carry out for the proposed treatment at each stage. According randomly 6 volunteers used in the first stage of the experiment the 16% peroxide carbamide gel (Home Peroxide, DMC) (CCL) and 7 volunteers used placebo gel (DMC) (SCL) that it was the same composition original gel, but without addition of peroxide. The volunteers applied the gel on the top of the specimens for 8h/day for 14 days during the two phases of the experiment. After bleaching treatment the specimens were subjected to the following surface treatments: polishing with Sof Lex (3M/ESPE) (TR1), without surface treatment (TR2) and the application of the sealant surface Biscover (BISCO) (TR3) and subsequently were immersed in red wine. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the gel, so that all used both gels. Finishing the second phase, the specimens were subjected to surface treatment and subsequent staining. The color change were measured 24 hours after bleaching in situ (L0) and 24 hours after surface treatment and red wine stains (L1) and the surface roughness were measured immediately after 24 hours of preparation of the specimens (L0) 24 hours after the in situ bleaching treatment (L1) and 24 hours after surface treatment and staining with red wine (L2). Data were submitted to ANOVA and Tukey. The results showed that: a) The bleaching showed no statistically significant difference for &Delta;E *, however, was significant for all parameters &Delta;L*, &Delta;a* and &Delta;b*; b) The composite 350 XT presented higher average of color change (&Delta;E * ) than Z250; c) The surface treatments with Sof Lex and Biscover had values of &Delta;E* statistically similar, while no treatment surface showed a statistically significant difference between the materials; d) Bleaching had no significant effect on surface roughness of composite resins; e) The composites showed higher values of surface roughness in L2 than in L1 and L0. f) TR3 demonstrated higher average of surface roughness than TR1 and TR2. It was concluded that bleaching did not affect the color change and surface roughness in the composites studied, the surface treatment had no effect clinically significant for the susceptibility to staining, and the composites studied had higher surface roughness when subjected to treatment surface staining associated with red wine and the surface sealant Biscover showed higher surface roughness for resin Z250.

Page generated in 0.0843 seconds