• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência da aplicação de selantes de superfície na perda de massa e alteração da rugosidade superficial de um compósito após aplicação tópica de flúor fosfato acidulado e ensaio de escovação / Influence of the application of surface sealants on weight loss and change of surface roughness of a composite after topical application of acidulated phosphate fluoride and toothbrushing assay

Bianca Mataveli Vimercati 17 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo teve por objetivo avaliar a degradação de um compósito após ciclos de escovação simulada, com ou sem a aplicação de selantes de superfície e com ou sem a aplicação tópica de flúor fosfato acidulado (FFA). A avaliação foi feita através da análise alteração da massa e da rugosidade superficial. Foram confeccionados 80 corpos-de-prova (CP) com o compósito Z250 (3M) (8mm x 3mm) e divididos em 4 grupos. Todos os grupos tiveram as superfícies regularizadas com lixa dágua 1.200. O grupo A (controle) não recebeu selamento, o grupo B recebeu aplicação do selante de superfície Fortify (Bisco), o grupo C, BisCover (Bisco) e o grupo D, Fill Glaze (Vigodent). Após isso, os CP foram armazenados em água destilada por 7 dias, em temperatura ambiente e, posteriormente, pesados em balança analítica para obtenção da massa inicial e submetidos à análise da rugosidade superficial inicial, utilizando rugosímetro Surftest SJ 201 P Mitutoyo. Os grupos A, B, C e D foram subdivididos em 2 grupos cada (n:10) e um subgrupo da cada grupo inicial (A2, B2, C2 e D2) foi submetido à aplicação de FFA (4 min), antes da escovação. Os grupos A1, B1, C1 e D1 permaneceram em água destilada. Após a remoção do FFA, todos os grupos foram armazenados em saliva artificial por 1 hora, em temperatura ambiente. Posteriormente foram submetidos a 30.000 ciclos de escovação, representando 6 meses de escovação diária. Foi utilizada escova dental macia (Ultra) e uma solução de creme dental (Colgate Máxima Proteção Anticáries) e água destilada na proporção de 1:2. Ao fim do ensaio, os CP foram lavados em água corrente por 5 minutos, secos com papel absorvente, pesados novamente para obtenção da massa final e submetidos à análise da rugosidade superficial final. O desgaste de cada CP foi avaliado através da perda de massa, que foi calculada pela diferença das pesagens antes e após a escovação e a alteração da rugosidade superficial foi calculada pela diferença entre os valores das médias de rugosidade superficial inicial e final. Algumas amostras foram analisadas em microscópio de força atômica com finalidade ilustrativa. Os dados obtidos foram tratados estatisticamente. Na análise da alteração de massa, quando comparado os grupos isoladamente, somente o grupo D1(FIL) não sofreu alteração de massa significativa. As comparações entre as médias de alteração de massa dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa somente nas comparações: A1(CONT)xB1(FFY) e B1(FFY)xD1(FIL). Para os grupos que receberam FFA, não houve diferença significativa entre as médias de alteração de massa. Na análise da alteração de rugosidade superficial, quando comparado os grupos isoladamente, houve aumento significativo de rugosidade superficial nos grupos A2(FFA), B2(FFY+FFA), C1(BIS) e C2(BIS+FFA). As comparações entre as médias de alteração de rugosidade superficial dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa apenas na comparação: C1(BIS)xD1(FIL). Para os grupos que receberam FFA, as comparações A2(FFA)xD2(FIL+FFA); B2(FFY+FFA)xD2(FIL+FFA); C2(BIS+FFA)xD2(FIL+FFA) mostraram diferenças significativas. Não foi observada correlação estatisticamente significante entre a alteração de massa e rugosidade superficial entre os grupos analisados. Com base nos resultados obtidos e na análise estatística realizada, pôde-se concluir que a aplicação de FFA e a aplicação de selantes de superfície não tiveram influência na alteração de massa e na rugosidade superficial dos materiais testados. O selante de superfície Fortify não protegeu o compósito após escovação, apresentando uma maior perda de massa no grupo B1 (Fortify) em comparação com o grupo A1 (controle). Os demais selantes testados protegeram o compósito. Não existiu correlação significativa entre perda de massa e alteração da rugosidade. / The aim of this study was to assess the degradation of a composite after simulated toothbrushing cycles, with or no applying surface sealants and with or no topical application of acidulated phosphate fluoride (APF). The assessment was made by analysis of change of weight and of surface roughness. Eighty specimens were made with the Z250 composite (3M) (8 mm x 3 mm) and divided in 4 groups. All the groups have their surfaces regularized with sandpapers 1.200 under water. The group A (control) have not seal, in the group B was applied the surface sealant Fortify (Bisco), in the group C the BisCover (Bisco), and in the group D the Fill Glaze (Vigodent). Following, the specimens were stored in distilled water for 7 days at room temperature and, subsequently, they were weighted in analytical scales for obtaining initial weight and subjected to analysis of initial surface roughness using the Surftest SJ 2001 P Mitutoyo profilometer of surface roughness. The groups A, B, C and D were subdivided in 2 groups each (n = 10) and a subgroup of every initial group (A2, B2, C2, D2) was subjected to application of APF (for 4 minutes) before the toothbrushing. The groups A1, B1, C1 and D1 remained in distillated water. After the removal of the APF, all the groups were stored in artificial saliva for 1 hour at room temperature. Subsequently they were subjected to 30000 cycles toothbrushing, representing 6 months of daily toothbrushing. The soft toothbrush (Ultra) and a toothpaste (ColgateCavity Protection) and distillated water in ratio 1:2 were used. At final of assay, the specimens were washed in running water for 5 minutes, dried with absorbent paper, measured again in order to obtain the final weight, and they were subjected to analysis of final surface roughness. The wear of each specimen was assessed by weight loss, which was calculated by difference of measuring before and after toothbrushing, and the change of surface roughness was calculated by difference between the values of initial and final surface roughness. Some samples were analysed in atomic force microscope with illustrative purpose. The data were treated statistically. In the analysis of weight change, when compared to groups separately, only the group D1 (FIL) have no significant weight change. The comparisons between the means of weight change of groups with or no APF showed there are no significant differences between all the comparisons: A1 (CONT) X B1 (FFY) and B1 (FFY) x D1 (FIL). For the groups with APF, there are no significant differences between the means of weight change. In the analysis of surface roughness change, when compared to groups separately, there was a significant increase of surface roughness in groups A2 (APF), B2 (FFY + APF), C1 (BIS) and C2 (BIS + APF). The comparisons between the means of surface roughness change of the groups with and no APF revealed there no differences significant between all of comparisons. For the groups with no APF, there was significant difference only in comparison C1 (BIS) x D1 (FIL). For the groups with APF, the comparisons A2 (APF) x D2 (FIL + APF), B2 (FFY + APF) x D2 (FIL + APF), C2 (BIS + APF) x D2 (FIL + APF) showed significant differences. It wasnt noted correlation significant statistically between weight change and surface roughness between the groups analyzed. With basis on findings obtained and in the statistical analysis accomplished, it could to conclude that the application of APF and the use of surface sealants have not influence on the weight change and surface roughness of composite tested. The surface sealant Fortfy have not protected the composite after toothbrushing, showing the higher weight loss in the group B1 (Fortfy) when compared to group A1 (control). The remainder sealants tested has protected the composite. There wasnt significant correlation between weight loss and roughness change.
2

Influência da aplicação de selantes de superfície na perda de massa e alteração da rugosidade superficial de um compósito após aplicação tópica de flúor fosfato acidulado e ensaio de escovação / Influence of the application of surface sealants on weight loss and change of surface roughness of a composite after topical application of acidulated phosphate fluoride and toothbrushing assay

Bianca Mataveli Vimercati 17 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo teve por objetivo avaliar a degradação de um compósito após ciclos de escovação simulada, com ou sem a aplicação de selantes de superfície e com ou sem a aplicação tópica de flúor fosfato acidulado (FFA). A avaliação foi feita através da análise alteração da massa e da rugosidade superficial. Foram confeccionados 80 corpos-de-prova (CP) com o compósito Z250 (3M) (8mm x 3mm) e divididos em 4 grupos. Todos os grupos tiveram as superfícies regularizadas com lixa dágua 1.200. O grupo A (controle) não recebeu selamento, o grupo B recebeu aplicação do selante de superfície Fortify (Bisco), o grupo C, BisCover (Bisco) e o grupo D, Fill Glaze (Vigodent). Após isso, os CP foram armazenados em água destilada por 7 dias, em temperatura ambiente e, posteriormente, pesados em balança analítica para obtenção da massa inicial e submetidos à análise da rugosidade superficial inicial, utilizando rugosímetro Surftest SJ 201 P Mitutoyo. Os grupos A, B, C e D foram subdivididos em 2 grupos cada (n:10) e um subgrupo da cada grupo inicial (A2, B2, C2 e D2) foi submetido à aplicação de FFA (4 min), antes da escovação. Os grupos A1, B1, C1 e D1 permaneceram em água destilada. Após a remoção do FFA, todos os grupos foram armazenados em saliva artificial por 1 hora, em temperatura ambiente. Posteriormente foram submetidos a 30.000 ciclos de escovação, representando 6 meses de escovação diária. Foi utilizada escova dental macia (Ultra) e uma solução de creme dental (Colgate Máxima Proteção Anticáries) e água destilada na proporção de 1:2. Ao fim do ensaio, os CP foram lavados em água corrente por 5 minutos, secos com papel absorvente, pesados novamente para obtenção da massa final e submetidos à análise da rugosidade superficial final. O desgaste de cada CP foi avaliado através da perda de massa, que foi calculada pela diferença das pesagens antes e após a escovação e a alteração da rugosidade superficial foi calculada pela diferença entre os valores das médias de rugosidade superficial inicial e final. Algumas amostras foram analisadas em microscópio de força atômica com finalidade ilustrativa. Os dados obtidos foram tratados estatisticamente. Na análise da alteração de massa, quando comparado os grupos isoladamente, somente o grupo D1(FIL) não sofreu alteração de massa significativa. As comparações entre as médias de alteração de massa dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa somente nas comparações: A1(CONT)xB1(FFY) e B1(FFY)xD1(FIL). Para os grupos que receberam FFA, não houve diferença significativa entre as médias de alteração de massa. Na análise da alteração de rugosidade superficial, quando comparado os grupos isoladamente, houve aumento significativo de rugosidade superficial nos grupos A2(FFA), B2(FFY+FFA), C1(BIS) e C2(BIS+FFA). As comparações entre as médias de alteração de rugosidade superficial dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa apenas na comparação: C1(BIS)xD1(FIL). Para os grupos que receberam FFA, as comparações A2(FFA)xD2(FIL+FFA); B2(FFY+FFA)xD2(FIL+FFA); C2(BIS+FFA)xD2(FIL+FFA) mostraram diferenças significativas. Não foi observada correlação estatisticamente significante entre a alteração de massa e rugosidade superficial entre os grupos analisados. Com base nos resultados obtidos e na análise estatística realizada, pôde-se concluir que a aplicação de FFA e a aplicação de selantes de superfície não tiveram influência na alteração de massa e na rugosidade superficial dos materiais testados. O selante de superfície Fortify não protegeu o compósito após escovação, apresentando uma maior perda de massa no grupo B1 (Fortify) em comparação com o grupo A1 (controle). Os demais selantes testados protegeram o compósito. Não existiu correlação significativa entre perda de massa e alteração da rugosidade. / The aim of this study was to assess the degradation of a composite after simulated toothbrushing cycles, with or no applying surface sealants and with or no topical application of acidulated phosphate fluoride (APF). The assessment was made by analysis of change of weight and of surface roughness. Eighty specimens were made with the Z250 composite (3M) (8 mm x 3 mm) and divided in 4 groups. All the groups have their surfaces regularized with sandpapers 1.200 under water. The group A (control) have not seal, in the group B was applied the surface sealant Fortify (Bisco), in the group C the BisCover (Bisco), and in the group D the Fill Glaze (Vigodent). Following, the specimens were stored in distilled water for 7 days at room temperature and, subsequently, they were weighted in analytical scales for obtaining initial weight and subjected to analysis of initial surface roughness using the Surftest SJ 2001 P Mitutoyo profilometer of surface roughness. The groups A, B, C and D were subdivided in 2 groups each (n = 10) and a subgroup of every initial group (A2, B2, C2, D2) was subjected to application of APF (for 4 minutes) before the toothbrushing. The groups A1, B1, C1 and D1 remained in distillated water. After the removal of the APF, all the groups were stored in artificial saliva for 1 hour at room temperature. Subsequently they were subjected to 30000 cycles toothbrushing, representing 6 months of daily toothbrushing. The soft toothbrush (Ultra) and a toothpaste (ColgateCavity Protection) and distillated water in ratio 1:2 were used. At final of assay, the specimens were washed in running water for 5 minutes, dried with absorbent paper, measured again in order to obtain the final weight, and they were subjected to analysis of final surface roughness. The wear of each specimen was assessed by weight loss, which was calculated by difference of measuring before and after toothbrushing, and the change of surface roughness was calculated by difference between the values of initial and final surface roughness. Some samples were analysed in atomic force microscope with illustrative purpose. The data were treated statistically. In the analysis of weight change, when compared to groups separately, only the group D1 (FIL) have no significant weight change. The comparisons between the means of weight change of groups with or no APF showed there are no significant differences between all the comparisons: A1 (CONT) X B1 (FFY) and B1 (FFY) x D1 (FIL). For the groups with APF, there are no significant differences between the means of weight change. In the analysis of surface roughness change, when compared to groups separately, there was a significant increase of surface roughness in groups A2 (APF), B2 (FFY + APF), C1 (BIS) and C2 (BIS + APF). The comparisons between the means of surface roughness change of the groups with and no APF revealed there no differences significant between all of comparisons. For the groups with no APF, there was significant difference only in comparison C1 (BIS) x D1 (FIL). For the groups with APF, the comparisons A2 (APF) x D2 (FIL + APF), B2 (FFY + APF) x D2 (FIL + APF), C2 (BIS + APF) x D2 (FIL + APF) showed significant differences. It wasnt noted correlation significant statistically between weight change and surface roughness between the groups analyzed. With basis on findings obtained and in the statistical analysis accomplished, it could to conclude that the application of APF and the use of surface sealants have not influence on the weight change and surface roughness of composite tested. The surface sealant Fortfy have not protected the composite after toothbrushing, showing the higher weight loss in the group B1 (Fortfy) when compared to group A1 (control). The remainder sealants tested has protected the composite. There wasnt significant correlation between weight loss and roughness change.
3

Efeito in situ do clareamento caseiro e subseqüentes tratamentos de superfície na cor e rugosidade superficial de resinas compostas / In situ effect of home bleaching and subsequent surface treatment on color and surface roughness of composite resins

Garcia, Lourdes Maria González 13 April 2012 (has links)
Este estudo avaliou in situ a susceptibilidade ao manchamento de duas resinas compostas Z350 XT® (M1) e Z250® (M2), ambas da 3M/ESPE por meio da alteração de cor e rugosidade superficial após o uso do agente clareador peróxido de carbamida 16% e subseqüentes tratamentos de superfície. Foram confeccionados 156 corpos-de-prova, n=13 para cada condição experimental. O estudo crossover teve duas fases de 14 dias cada, com um período de washout de 9 dias. Os corpos de prova de cada material foram montados em placas de acetato, distribuídos em 13 voluntários, na região dos segundos pré-molares, primeiros e segundos molares superiores e instalados nos participantes para a realização do tratamento proposto em cada fase. De acordo com aleatorização, 6 voluntários utilizaram na primeira fase do experimento o gel a base de peróxido de carbamida 16% (Home Peroxide, DMC) (CCL) e 7 voluntários o gel placebo (DMC) (SCL) da mesma composição do gel original, porém sem adição do peróxido. Os voluntários aplicaram os géis nos corpos-deprova por 8h/dia, durante 14 dias nas duas fases do experimento. Após o clareamento os corpos de prova foram submetidos aos seguintes tratamentos de superfícies: polimento com discos Sof Lex (3M/ESPE) (TR1), sem tratamento de superfície (TR2) e a aplicação do selante de superfície Biscover (BISCO) (TR3) e subseqüentemente foram imersos em vinho tinto. As leituras de cor foram realizadas 24 horas após o clareamento (L0) e 24 horas após tratamento de superfície e manchamento (L1), já para a rugosidade superficial foram realizadas 3 leituras: 24 horas após a confecção dos corpos-de-prova (L0), 24 horas após o clareamento (L1) e 24 horas após tratamento de superfície e manchamento (L2). Os dados foram submetidos ao teste ANOVA e Tukey. Os resultados mostraram que: a) O Clareamento não determinou diferença estatisticamente de ΔE*, no entanto, foi significante para ΔL*, Δa* e Δb*; b) A resina M1 apresentou maior média de ΔE* que a M2; c) Os tratamentos de superfície com Sof Lex e Biscover apresentaram valores de ΔE* estaticamente semelhantes, enquanto que o sem tratamento apresentou diferença estatisticamente significante entre os materiais; d) O clareamento não teve efeito significante na rugosidade superficial de resinas estudadas; e) M1 e M2 apresentaram maior rugosidade superficial em L2 que em L0 e L1; f) TR3 apresentou maior média de rugosidade superficial que TR1 e TR2. Conclui-se que: a resina Z350 XT apresentou maior alteração de cor que a Z250; o clareamento aplicado no tempo estabelecido neste estudo não promoveu alteração de cor e não influenciou na rugosidade superficial nas resinas compostas estudadas; e as resinas compostas estudadas apresentaram maior rugosidade após o Tratamento de superfície associado ao manchamento com vinho tinto; o selante de superfície Biscover apresentou maior rugosidade superficial para a resina Z250. / This study evaluated in situ the staining susceptibility of different composite resins (Z350 XT ® (M1) and Z250 ® (M2), both of 3M/ESPE) by color change and surface roughness after the aplication of 16% carbamide peroxide bleaching gel and subsequent surface treatments and staining with red wine. One hundred fifty-six specimens were fabricated where n=13 were per experimental condition. The study had two phases of 14 days each, with a washout period of 9 days between them. The specimens of each material fixed into custom fabricated trays in 13 volunteers in the region of the second premolars, first and second molars and installed in the participants to carry out for the proposed treatment at each stage. According randomly 6 volunteers used in the first stage of the experiment the 16% peroxide carbamide gel (Home Peroxide, DMC) (CCL) and 7 volunteers used placebo gel (DMC) (SCL) that it was the same composition original gel, but without addition of peroxide. The volunteers applied the gel on the top of the specimens for 8h/day for 14 days during the two phases of the experiment. After bleaching treatment the specimens were subjected to the following surface treatments: polishing with Sof Lex (3M/ESPE) (TR1), without surface treatment (TR2) and the application of the sealant surface Biscover (BISCO) (TR3) and subsequently were immersed in red wine. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the gel, so that all used both gels. Finishing the second phase, the specimens were subjected to surface treatment and subsequent staining. The color change were measured 24 hours after bleaching in situ (L0) and 24 hours after surface treatment and red wine stains (L1) and the surface roughness were measured immediately after 24 hours of preparation of the specimens (L0) 24 hours after the in situ bleaching treatment (L1) and 24 hours after surface treatment and staining with red wine (L2). Data were submitted to ANOVA and Tukey. The results showed that: a) The bleaching showed no statistically significant difference for ΔE *, however, was significant for all parameters ΔL*, Δa* and Δb*; b) The composite 350 XT presented higher average of color change (ΔE * ) than Z250; c) The surface treatments with Sof Lex and Biscover had values of ΔE* statistically similar, while no treatment surface showed a statistically significant difference between the materials; d) Bleaching had no significant effect on surface roughness of composite resins; e) The composites showed higher values of surface roughness in L2 than in L1 and L0. f) TR3 demonstrated higher average of surface roughness than TR1 and TR2. It was concluded that bleaching did not affect the color change and surface roughness in the composites studied, the surface treatment had no effect clinically significant for the susceptibility to staining, and the composites studied had higher surface roughness when subjected to treatment surface staining associated with red wine and the surface sealant Biscover showed higher surface roughness for resin Z250.
4

Efeito in situ do clareamento caseiro e subseqüentes tratamentos de superfície na cor e rugosidade superficial de resinas compostas / In situ effect of home bleaching and subsequent surface treatment on color and surface roughness of composite resins

Lourdes Maria González Garcia 13 April 2012 (has links)
Este estudo avaliou in situ a susceptibilidade ao manchamento de duas resinas compostas Z350 XT® (M1) e Z250® (M2), ambas da 3M/ESPE por meio da alteração de cor e rugosidade superficial após o uso do agente clareador peróxido de carbamida 16% e subseqüentes tratamentos de superfície. Foram confeccionados 156 corpos-de-prova, n=13 para cada condição experimental. O estudo crossover teve duas fases de 14 dias cada, com um período de washout de 9 dias. Os corpos de prova de cada material foram montados em placas de acetato, distribuídos em 13 voluntários, na região dos segundos pré-molares, primeiros e segundos molares superiores e instalados nos participantes para a realização do tratamento proposto em cada fase. De acordo com aleatorização, 6 voluntários utilizaram na primeira fase do experimento o gel a base de peróxido de carbamida 16% (Home Peroxide, DMC) (CCL) e 7 voluntários o gel placebo (DMC) (SCL) da mesma composição do gel original, porém sem adição do peróxido. Os voluntários aplicaram os géis nos corpos-deprova por 8h/dia, durante 14 dias nas duas fases do experimento. Após o clareamento os corpos de prova foram submetidos aos seguintes tratamentos de superfícies: polimento com discos Sof Lex (3M/ESPE) (TR1), sem tratamento de superfície (TR2) e a aplicação do selante de superfície Biscover (BISCO) (TR3) e subseqüentemente foram imersos em vinho tinto. As leituras de cor foram realizadas 24 horas após o clareamento (L0) e 24 horas após tratamento de superfície e manchamento (L1), já para a rugosidade superficial foram realizadas 3 leituras: 24 horas após a confecção dos corpos-de-prova (L0), 24 horas após o clareamento (L1) e 24 horas após tratamento de superfície e manchamento (L2). Os dados foram submetidos ao teste ANOVA e Tukey. Os resultados mostraram que: a) O Clareamento não determinou diferença estatisticamente de ΔE*, no entanto, foi significante para ΔL*, Δa* e Δb*; b) A resina M1 apresentou maior média de ΔE* que a M2; c) Os tratamentos de superfície com Sof Lex e Biscover apresentaram valores de ΔE* estaticamente semelhantes, enquanto que o sem tratamento apresentou diferença estatisticamente significante entre os materiais; d) O clareamento não teve efeito significante na rugosidade superficial de resinas estudadas; e) M1 e M2 apresentaram maior rugosidade superficial em L2 que em L0 e L1; f) TR3 apresentou maior média de rugosidade superficial que TR1 e TR2. Conclui-se que: a resina Z350 XT apresentou maior alteração de cor que a Z250; o clareamento aplicado no tempo estabelecido neste estudo não promoveu alteração de cor e não influenciou na rugosidade superficial nas resinas compostas estudadas; e as resinas compostas estudadas apresentaram maior rugosidade após o Tratamento de superfície associado ao manchamento com vinho tinto; o selante de superfície Biscover apresentou maior rugosidade superficial para a resina Z250. / This study evaluated in situ the staining susceptibility of different composite resins (Z350 XT ® (M1) and Z250 ® (M2), both of 3M/ESPE) by color change and surface roughness after the aplication of 16% carbamide peroxide bleaching gel and subsequent surface treatments and staining with red wine. One hundred fifty-six specimens were fabricated where n=13 were per experimental condition. The study had two phases of 14 days each, with a washout period of 9 days between them. The specimens of each material fixed into custom fabricated trays in 13 volunteers in the region of the second premolars, first and second molars and installed in the participants to carry out for the proposed treatment at each stage. According randomly 6 volunteers used in the first stage of the experiment the 16% peroxide carbamide gel (Home Peroxide, DMC) (CCL) and 7 volunteers used placebo gel (DMC) (SCL) that it was the same composition original gel, but without addition of peroxide. The volunteers applied the gel on the top of the specimens for 8h/day for 14 days during the two phases of the experiment. After bleaching treatment the specimens were subjected to the following surface treatments: polishing with Sof Lex (3M/ESPE) (TR1), without surface treatment (TR2) and the application of the sealant surface Biscover (BISCO) (TR3) and subsequently were immersed in red wine. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the gel, so that all used both gels. Finishing the second phase, the specimens were subjected to surface treatment and subsequent staining. The color change were measured 24 hours after bleaching in situ (L0) and 24 hours after surface treatment and red wine stains (L1) and the surface roughness were measured immediately after 24 hours of preparation of the specimens (L0) 24 hours after the in situ bleaching treatment (L1) and 24 hours after surface treatment and staining with red wine (L2). Data were submitted to ANOVA and Tukey. The results showed that: a) The bleaching showed no statistically significant difference for ΔE *, however, was significant for all parameters ΔL*, Δa* and Δb*; b) The composite 350 XT presented higher average of color change (ΔE * ) than Z250; c) The surface treatments with Sof Lex and Biscover had values of ΔE* statistically similar, while no treatment surface showed a statistically significant difference between the materials; d) Bleaching had no significant effect on surface roughness of composite resins; e) The composites showed higher values of surface roughness in L2 than in L1 and L0. f) TR3 demonstrated higher average of surface roughness than TR1 and TR2. It was concluded that bleaching did not affect the color change and surface roughness in the composites studied, the surface treatment had no effect clinically significant for the susceptibility to staining, and the composites studied had higher surface roughness when subjected to treatment surface staining associated with red wine and the surface sealant Biscover showed higher surface roughness for resin Z250.

Page generated in 0.0953 seconds