• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determining the construct validity of the safety survey instrument

Windbacher, Maritza 20 February 2012 (has links)
Safety interventions must be approached in a holistic manner, by taking cognisance of the organisational system in which accidents present themselves. Thus, a need to understand the individual in context of the organisational system that he/she functions in exists. This study focuses on the relationship between attitudes, beliefs, intention, perception, control and the propensity of employees to engage in unsafe behaviour, with a view towards improving safety statistics. In this regard the study investigated the construct validity of a Safety Survey instrument, based on the responses (n=450) of employees in the mining industry. An Exploratory Factor Analysis showed that the Safety Survey instrument differentiated between two to three underlying factors. The result of the Confirmatory Factor Analysis tested two models by demonstrating the minimum requirements of the goodness of fit indexes. The construct validity of the Safety Survey instrument could be established for two nested models that identified an internal and external locus of control factor. The statistical evidence indicated an acceptable model fit. The statistical evidence validated the construct validity of the measurement model. Copyright 2008, University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. Please cite as follows: Windbacher, M 2008, Determining the construct validity of the safety survey instrument, MCom dissertation, University of Pretoria, Pretoria, viewed yymmdd < http://upetd.up.ac.za/thesis/available/etd-02202012-123434 / > C12/4/66/gm / Dissertation (MCom)--University of Pretoria, 2008. / Human Resource Management / unrestricted
2

The Use of Self Survey Instrument (UoS-SI): An Exploratory Factor Analysis and Reliability Analysis

Traxler, Jennifer L. 30 August 2022 (has links)
No description available.
3

The Development of an Electronic Data Collection Tool and Comparison of the Electronic and Manual Methods of Land Use Inventory

Catanzaro, Wesley M 01 June 2013 (has links) (PDF)
An important component of Planning Information Systems for municipal planning agencies is a comprehensive land use inventory that provides information on the location, distribution, and intensity of land uses throughout a community. This data is a necessary prerequisite for the informed creation of planning documents such as General Plans, Specific Plans, Housing Inventories, and Climate Action Plans. Beyond location, distribution and intensity of land uses, planners may also wish to incorporate additional information at the parcel level, such as the number of housing or commercial units, building condition, and/or access and connectivity to adjacent streets. Because some of this information is best observed in the field, agencies require methods of collecting this data that will ensure data precision, accuracy, and consistency, while minimizing data collection and processing time. Electronic data collection tools that are compatible with Geographic Information Systems provide a potential solution that can facilitate these desired data collection parameters. This research illustrates the development of an electronic data collection tool that planning agencies may utilize within various planning efforts, and compares the efficiency of the tool to traditional ‘pen-and-paper’ data collection methods in terms of time savings. It is recommended that planning agencies widely adopt and implement electronic tools for land use data collection, for the demonstrated benefits related to data consistency and reduced data collection time in the field.
4

Building & Measuring Psychological Capacity for Biodiversity Conservation

Cranston, Kayla A., Cranston 01 September 2016 (has links)
No description available.
5

Radiographic contrast-enhancement masks in digital radiography

Davidson, Robert Andrew January 2006 (has links)
Doctor of Philosophy / Radiographic film/screen (F/S) images have a narrow latitude or dynamic range. The film’s ability to record and view all the anatomy within the x-ray field is limited by this narrow dynamic range. The advent of digital radiographic means of storing and displaying radiographic images has improved the ability to record and visualise all of the anatomy. The problem still exists in digital radiography (DR) when radiographic examinations of certain anatomical regions are undertaken. In this work, the value of anatomically shaped radiographic contrast-enhancement masks (RCMs) in improving image contrast and reducing the dynamic range of images in DR was examined. Radiographic contrast-enhancement masks are digital masks that alter the radiographic contrast in DR images. The shape of these masks can be altered by the user. Anatomically shaped RCMs have been modelled on tissue compensation filters (TCFs) commonly used in F/S radiographic examinations. The prime purpose of a TCF is to reduce the dynamic range of photons reaching the image receptor and hence improve radiographic contrast in the resultant image. RCMs affect the dynamic range of the image rather than the energy source of the image, that of the x-ray photons. The research consisted of three distinct phases. The first phase was to examine physical TCFs and their effects on F/S radiographic images. Physical TCFs are used in radiographic F/S examinations to attenuate the x-ray beam to compensate for varying patient tissue thicknesses and/or densities. The effect of the TCF is to reduce resultant radiographic optical density variations in the image, allowing the viewer to observe a range of densities within the image which would otherwise not be visualised. Physical TCFs are commonly aluminium- or lead-based materials that attenuate the x-ray beam. A TCF has varying physical thickness to differentially attenuate the iii beam and is shaped for specific anatomical situations. During this project, various commonly used physical TCFs were examined. Measurements of size and thickness were made. Characteristics of linear attenuation coefficients and half-value thicknesses were delineated for various TCF materials and at various energies. The second phase of the research was to model the physical TCFs in a digital environment and apply the RCMs to DR images. The digital RCMs were created with similar characteristics to mimic the shapes to the physical TCFs. The RCM characteristics can be adjusted by the viewer of the image to suit the anatomy being imaged. Anatomically shaped RCMs were designed to assist in overcoming a limitation when viewing digital radiographic images, that of the dynamic range of the image. Anatomically shaped RCMs differ from other means of controlling the dynamic range of a digital radiographic image. It has been shown that RCMs can reduce the range of optical densities within images with a large dynamic range, to facilitate visualisation of all anatomy within the image. Physical TCFs are used within a specific range of radiographic F/S examinations. Digital radiographic images from this range of examinations were collected from various clinical radiological centres. Anatomically shaped RCMs were applied to the images to improve radiographic contrast of the images. The third phase of the research was to ascertain the benefits of the use of RCMs. Various other methods are currently in use to reduce the dynamic range of digital radiographic images. It is generally accepted that these methods also introduce noise into the image and hence reduce image quality. Quantitative comparisons of noise within the image were undertaken. The anatomically shaped RCMs introduced less noise than current methods designed to reduce the dynamic range of digital radiographic images. It was shown that RCM methods do not affect image quality. Radiographers make subjective assessment of digital radiographic image quality as part of their professional practice. To assess the subjective quality of images enhanced with anatomically shaped RCMs, a survey of radiographers and other iv qualified people was undertaken to ascertain any improvement in RCM-modified images compared to the original images. Participants were provided with eight pairs of image to compare. Questions were asked in the survey as to which image had the better range of optical densities; in which image the anatomy was easiest to visualise; which image had the simplest contrast and density manipulation for optimal visualisation; and which image had the overall highest image quality. Responses from 123 participants were received and analysed. The statistical analysis showed a higher preference by radiographers for the digital radiographic images in which the RCMs had been applied. Comparisons were made between anatomical regions and between patient-related factors of size, age and whether pathology was present in the image or not. The conclusion was drawn that digital RCMs correctly applied to digital radiographic images decrease the dynamic range of the image, allowing the entire anatomy to be visualised in one image. Radiographic contrast in the image can be maximised whilst maintaining image quality. Using RCMs in some digital radiographic examinations, radiographers will be able to present optimised images to referring clinicians. It is envisaged that correctly applied RCMs in certain radiographic examinations will enhance radiographic image quality and possibly lead to improved diagnosis from these images.
6

Radiographic contrast-enhancement masks in digital radiography

Davidson, Robert Andrew January 2006 (has links)
Doctor of Philosophy / Radiographic film/screen (F/S) images have a narrow latitude or dynamic range. The film’s ability to record and view all the anatomy within the x-ray field is limited by this narrow dynamic range. The advent of digital radiographic means of storing and displaying radiographic images has improved the ability to record and visualise all of the anatomy. The problem still exists in digital radiography (DR) when radiographic examinations of certain anatomical regions are undertaken. In this work, the value of anatomically shaped radiographic contrast-enhancement masks (RCMs) in improving image contrast and reducing the dynamic range of images in DR was examined. Radiographic contrast-enhancement masks are digital masks that alter the radiographic contrast in DR images. The shape of these masks can be altered by the user. Anatomically shaped RCMs have been modelled on tissue compensation filters (TCFs) commonly used in F/S radiographic examinations. The prime purpose of a TCF is to reduce the dynamic range of photons reaching the image receptor and hence improve radiographic contrast in the resultant image. RCMs affect the dynamic range of the image rather than the energy source of the image, that of the x-ray photons. The research consisted of three distinct phases. The first phase was to examine physical TCFs and their effects on F/S radiographic images. Physical TCFs are used in radiographic F/S examinations to attenuate the x-ray beam to compensate for varying patient tissue thicknesses and/or densities. The effect of the TCF is to reduce resultant radiographic optical density variations in the image, allowing the viewer to observe a range of densities within the image which would otherwise not be visualised. Physical TCFs are commonly aluminium- or lead-based materials that attenuate the x-ray beam. A TCF has varying physical thickness to differentially attenuate the iii beam and is shaped for specific anatomical situations. During this project, various commonly used physical TCFs were examined. Measurements of size and thickness were made. Characteristics of linear attenuation coefficients and half-value thicknesses were delineated for various TCF materials and at various energies. The second phase of the research was to model the physical TCFs in a digital environment and apply the RCMs to DR images. The digital RCMs were created with similar characteristics to mimic the shapes to the physical TCFs. The RCM characteristics can be adjusted by the viewer of the image to suit the anatomy being imaged. Anatomically shaped RCMs were designed to assist in overcoming a limitation when viewing digital radiographic images, that of the dynamic range of the image. Anatomically shaped RCMs differ from other means of controlling the dynamic range of a digital radiographic image. It has been shown that RCMs can reduce the range of optical densities within images with a large dynamic range, to facilitate visualisation of all anatomy within the image. Physical TCFs are used within a specific range of radiographic F/S examinations. Digital radiographic images from this range of examinations were collected from various clinical radiological centres. Anatomically shaped RCMs were applied to the images to improve radiographic contrast of the images. The third phase of the research was to ascertain the benefits of the use of RCMs. Various other methods are currently in use to reduce the dynamic range of digital radiographic images. It is generally accepted that these methods also introduce noise into the image and hence reduce image quality. Quantitative comparisons of noise within the image were undertaken. The anatomically shaped RCMs introduced less noise than current methods designed to reduce the dynamic range of digital radiographic images. It was shown that RCM methods do not affect image quality. Radiographers make subjective assessment of digital radiographic image quality as part of their professional practice. To assess the subjective quality of images enhanced with anatomically shaped RCMs, a survey of radiographers and other iv qualified people was undertaken to ascertain any improvement in RCM-modified images compared to the original images. Participants were provided with eight pairs of image to compare. Questions were asked in the survey as to which image had the better range of optical densities; in which image the anatomy was easiest to visualise; which image had the simplest contrast and density manipulation for optimal visualisation; and which image had the overall highest image quality. Responses from 123 participants were received and analysed. The statistical analysis showed a higher preference by radiographers for the digital radiographic images in which the RCMs had been applied. Comparisons were made between anatomical regions and between patient-related factors of size, age and whether pathology was present in the image or not. The conclusion was drawn that digital RCMs correctly applied to digital radiographic images decrease the dynamic range of the image, allowing the entire anatomy to be visualised in one image. Radiographic contrast in the image can be maximised whilst maintaining image quality. Using RCMs in some digital radiographic examinations, radiographers will be able to present optimised images to referring clinicians. It is envisaged that correctly applied RCMs in certain radiographic examinations will enhance radiographic image quality and possibly lead to improved diagnosis from these images.

Page generated in 0.0569 seconds