• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Corrélation entre les donnés de l'imagerie par résonance magnetique (IRM) cardiaque et le cathétérisme droit dans l'hypertension artérielle pulmonaire (HTAP)

Hoette, Susana 20 August 2012 (has links) (PDF)
La fraction d'éjection du ventricule droit (FEVD) est un marqueur de survie en cas d'hypertension pulmonaire (PH), mais sa mesure est compliquée et fastidieuse. Le TAPSE (Tricuspid Annular Plane Systolic Excursion) est un bon indice de la FEVD mais il ne mesure que la composante longitudinale de la contraction ventriculaire droite. La fraction de variation surfacique du ventricule droit RVFAC (Right Ventricular Fractional Area Change) semble être un meilleur indice de FEVD car il prend en compte le sens longitudinal et transversal des éléments de la contraction du ventricule droit. Le but de notre étude était d'évaluer la performance RVFAC fonction de la sévérité hémodynamique chez les deux groupes de patients atteints de PH:l'hypertension artérielle pulmonaire (HAP) et l'hypertension pulmonaire thromboembolique chronique (CTEPH).Methodes: Soixante-deux patients atteints d'HTAP et CTEPH ont bénéficié d'un cathétérisme cardiaque droit et d'une IRM cardiaque dans un délai de 72 heures. Les surfaces ventriculaires droite et gauche a la fin de la diastole (RVEDA, LVEDA), la surface du ventricule droit a la fin da la systole (RVESA) et TAPSE ont été mesurés dans la vue quatre cavités. Le RVFAC (RVFAC=RVEDA-RVESA/RVEDA) et le rapport RVEDA/LVEDA ont été calculés. Le diamètre entre la paroi libre et le septum (DF-S) et le diamètre entre les parois antérieure et postérieures du ventricule gauche (DA-P) ont été mesurés et l'indice d'excentricité LV (IE) a été calculé (= DA-P / DF-S). Le RVEF a été calculée à l'aide de coupes jointives de 6 mm en petit axe du ventricule droit.Résultats: La population avait un âge moyen de 58 ans avec une majorité des femmes, la plupart des patients étaient en classe fonctionnelle III, 23 avaient des HAP) et 39 des CTEPH. La RVEF était faiblement corrélée aux variables hémodynamiques de la post-charge et de la fonction VD. Le RVFAC était plus fortement corrélée à FEVD (R2 = 0,65, p <0,001) que TAPSE (R2 = 0,35, p <0,001). Une FEVD <35% était mieux prédite par un RVFAC bas que par une diminution de TAPSE (TAPSE: AUC 0,73 et RVFAC: AUC 0,93, p = 0,0065). Nous avons divisé la population par la médiane de la résistance artérielle pulmonaire (RAP) et nous avons observé que dans le groupe avec la pire sévérité hémodynamique, cette différence a augmenté: dans le groupe avec PVR < 8,5 UW (RVFAC: R2 = 0,66, p <0,001 et TAPSE: R2 = 0,30, p =0,002) et dans le groupe avec PVR > 8,5 UW (RVFAC: R2 = 0,51, p <0,001 et TAPSE: R2 = 0,14, p = 0,041). Le groupe avec PVR> 8,5 WU avait un rapport RVEDA/LVEDA augmenté et une augmentation de l'indice excentricité. Les relations RVEF-RVFAC n'étaient pas différentes entre les groupes de HAP et CETPH.Conclusion: La fraction de variation surfacique du ventricule droit RVFAC fournit un reflet simple et fiable de la FEVD peut-être parce que contrairement à TAPSE qui ne prend en compte que le raccourcissement longitudinal, RFVAC prend également en compte la composante transversale de la fonction ventriculaire droite.
2

Approche formelle pour la simulation interactive de modèles mixtes / A formal approach for the interactive simulation of mixed models

Faure, Xavier 29 September 2014 (has links)
La simulation interactive du corps humain est un problème crucial en informatique médicale. Les approches sont multiples pour arriver à cet objectif. Diminuer le temps de calcul est le leitmotiv d'un grand nombre de travaux ces dernières années. Pour les recherches qui utilisent des modèles physiques inspirés de la Mécanique des Milieux Continus pour la simulation des objets déformables, ce sont principalement les forces internes et leurs dérivées qui font l'objet d'études pour l'amélioration des performances au niveau du temps de calcul. Nous avons choisi de développer la Méthode des Masses-Tenseurs, modèle physique souvent utilisé pour son bon compromis temps de calcul — précision. Notre première contribution est l'utilisation du calcul formel pour la génération des équations des forces internes et de leurs dérivées. Notre deuxième contribution est la parallélisation de ce modèle physique en calculant les équations générées sur le GPU. Notre troisième contribution est l'extension de ce modèle physique à d'autres types d'éléments : triangle, quadrangle, hexaèdre, prisme et pyramide. Tenir compte des déformations pour utiliser la loi de comportement la plus efficace en temps de calcul lorsque c'est possible, est une stratégie que nous avons mis en place. Dans la même idée, nous prenons en compte la géométrie du modèle à simuler pour utiliser des éléments plus complexes mais en nombre réduit. Pour utiliser ces stratégies, nous avons développé et utilisé des modèles mixtes en loi de comportement et en type d'éléments. Nos travaux se placent dans le contexte du projet ETOILE pour le développement d'un modèle biomécanique du système respiratoire / Interactive simulation of the human body is a crucial issue in medical computer sciences. There are many approaches to reach this goal. Reducing the computation time is the leitmotiv of a large number of efforts in recent years. For researches which use physical models derived from continuum mechanics for the simulation of deformable objects, it is primarily the internal forces and their derivatives which are the subject of study for improving computation time. We chose to develop the Tensor Mass Method, a physical model often used for its good computation time vs accuracy trade-off. Our first contribution is the use of computer algebra to generate the internal forces and their derivatives. Our second contribution is the parallelization of this physical model by computing the generated equations on the GPU. Our third contribution is an extension of this physical model to other elements : triangle, quandrangle , hexahedron, prism and pyramid. Considering deformations to use the most effective constitutive law in terms of computation time whenever possible is a good strategy that we started developing. In the same idea, we take the geometry of the simulated model into account to introduce more complex elements, albeit in reduced numbers. To use these strategies, we have developed mixed models in constitutive laws and elements. Our research was performed in the framework of the ETOILE project, to develop a biomechanical model of the respiratory system
3

Mechanisms of altitude-related cough / Mécanismes de la toux liée à l'altitude

Mason, Nicholas 18 April 2012 (has links)
The original work presented in this thesis investigates some of the mechanisms that may be responsible for the aetiology of altitude-related cough. Particular attention is paid to its relationship to the long recognised, but poorly understood, changes in lung volumes that occur on ascent to altitude. The literature relevant to this thesis is reviewed in Chapter 1.<p><p>Widespread reports have long existed of a debilitating cough affecting visitors to high altitude that can incapacitate the sufferer and, on occasions, be severe enough to cause rib fractures (22, 34, 35). The prevalence of cough at altitude has been estimated to be between 22 and 42% at between 4200 and 4900 m in the Everest region of Nepal (10, 29). Traditionally the cough was attributed to the inspiration of the cold, dry air characteristic of the high altitude environment (37) but no attempts were made to confirm this aetiology. In the first formal study of cough at high altitude, nocturnal cough frequency was found to increase with increasing altitude during a trek to Everest Base Camp (5300 m) and massively so in 3 climbers on whom recordings were made up to 7000 m on Everest (8). After 9 days at 5300 m the citric acid cough threshold, a measure of the sensitivity of the cough reflex arc, was significantly reduced compared with both sea level and arrival at 5300 m.<p><p>During Operation Everest II, a simulated climb of Mount Everest in a hypobaric chamber, the majority of the subjects were troubled above 7000 m by pain and dryness in the throat and an irritating cough despite the chamber being maintained at a relative humidity of between 72 and 82% and a temperature of 23ºC (18). This argued against the widely held view that altitude-related cough was due to the inspiration of cold, dry air. <p><p>In the next major hypobaric chamber study, Operation Everest III, nocturnal cough frequency and citric acid cough threshold were measured on the 8 subjects in the study. The chamber temperature was maintained between 18 and 24ºC and relative humidity between 30 and 60% (24). This work is presented in Chapter 2 and, demonstrated an increase in nocturnal cough frequency with increasing altitude which immediately returned to control values on descent to sea level. Citric acid cough threshold was reduced at 8000 m compared to both sea level and 5000 m values. Changes in citric acid cough threshold at lower altitudes may not have been detected because of the constraints on subject numbers in the chamber. The study still however demonstrated an increase in clinical cough and a reduction in the citric acid cough threshold at extreme altitude, despite controlled environmental conditions, and thus refuted the long held belief that altitude-related cough is solely due to the inspiration of cold, dry air. <p><p>If altitude-related cough is not simply due to the inspiration of cold, dry air, other possible aetiologies are:<p>•\ / Doctorat en Sciences médicales / info:eu-repo/semantics/nonPublished
4

Heart rate variability and respiration signals as late onset sepsis diagnostic tools in neonatal intensive care units / Variabilité du rythme cardiaque et de la respiration comme outils de diagnostic d'apparition tardive de sepsis dans les unités de soins intensifs néonataux

Wang, Yuan 19 December 2013 (has links)
Le sepsis tardif, défini comme une infection systémique chez les nouveaux nés âgés de plus de 3 jours, survient chez environ 7% à 10% de tous les nouveau-nés et chez plus de 25% des nouveau-nés de très faible poids de naissance qui sont hospitalisés dans les unités de soins intensifs néonatals (USIN). Les apnées et bradycardies (AB) spontanées récurrentes et graves sont parmi les principaux indicateurs précoces cliniques de l'infection systémique chez les prématurés. L'objectif de cette thèse est de déterminer si la variabilité du rythme cardiaque (VRC), la respiration et l'analyse de leurs relations aident au diagnostic de l'infection chez les nouveaux nés prématurés par des moyens non invasifs en USIN. Par conséquent, on a effectué l'analyse Mono-Voie (MV) et Bi-Voies (BV) sur deux groupes sélectionnés de nouveau-nés prématurés: sepsis (S) vs. non-sepsis (NS). (1) Tout d'abord, on a étudié la série RR non seulement par des méthodes de distribution (moy, varn, skew, kurt, med, SpAs), par les méthodes linéaire: le domaine temporel (SD, RMSSD) et dans le domaine fréquentiel (p_VLF, p_LF, p_HF), mais aussi par les méthodes non–linéaires: la théorie du chaos (alphas, alphaF) et la théorie de l'information (AppEn, SamEn, PermEn, Regul). Pour chaque méthode, nous étudions trois tailles de fenêtre 1024/2048/4096, puis nous comparons ces méthodes afin de trouver les meilleures façons de distinguer S de NS. Les résultats montrent que les indices alphaS, alphaF et SamEn sont les paramètres optimaux pour séparer les deux populations. (2) Ensuite, la question du couplage fonctionnel entre la VRC et la respiration nasale est adressée. Des relations linéaires et non-linéaires ont été explorées. Les indices linéaires sont la corrélation (r²), l'indice de la fonction de cohérence (Cohere) et la corrélation temps-fréquence (r2t,f) , tandis que le coefficient de régression non-linéaire (h²) a été utilisé pour analyser des relations non-linéaires. Nous avons calculé les deux directions de couplage pendant l'évaluation de l'indice h2 de régression non-linéaire. Enfin, à partir de l'ensemble du processus d'analyse, il est évident que les trois indices (r2tf_rn_raw_0p2_0p4, h2_rn_raw et h2_nr_raw) sont des moyens complémentaires pour le diagnostic du sepsis de façon non-invasive chez ces patients fragiles. (3) Après, l'étude de faisabilité de la détection du sepsis en USIN est réalisée sur la base des paramètres retenus lors des études MV et BV. Nous avons montré que le test proposé, basé sur la fusion optimale des six indices ci-dessus, conduit à de bonnes performances statistiques. En conclusion, les mesures choisies lors de l'analyse des signaux en MV et BV ont une bonne répétabilité et permettent de mettre en place un test en vue du diagnostic non invasif et précoce du sepsis. Le test proposé peut être utilisé pour fournir une alarme fiable lors de la survenue d'un épisode d'AB tout en exploitant les systèmes de monitoring actuels en USIN. / Late-onset sepsis, defined as a systemic infection in neonates older than 3 days, occurs in approximately 10% of all neonates and in more than 25% of very low birth weight infants who are hospitalized in Neonatal Intensive Care Units (NICU). Recurrent and severe spontaneous apneas and bradycardias (AB) is one of the major clinical early indicators of systemic infection in the premature infant. Various hematological and biochemical markers have been evaluated for this indication but they are invasive procedures that cannot be repeated several times. The objective of this Ph.D dissertation was to determine if heart rate variability (HRV), respiration and the analysis of their relationships help to the diagnosis of infection in premature infants via non-invasive ways in NICU. Therefore, we carried out Mono-Channel (MC) and Bi-Channel (BC) Analysis in two selected groups of premature infants: sepsis (S) vs. non-sepsis (NS). (1) Firstly, we studied the RR series not only by distribution methods (moy, varn, skew, kurt, med, SpAs), by linear methods: time domain (SD, RMSSD) and frequency domain (p_VLF, p_LF, p_HF), but also by non-linear methods: chaos theory (alphaS, alphaF) and information theory (AppEn, SamEn, PermEn, Regul). For each method, we attempt three sizes of window 1024/2048/4096, and then compare these methods in order to find the optimal ways to distinguish S from NS. The results show that alphaS, alphaF and SamEn are optimal parameters to recognize sepsis from the diagnosis of late neonatal infection in premature infants with unusual and recurrent AB. (2) The question about the functional coupling of HRV and nasal respiration is addressed. Linear and non-linear relationships have been explored. Linear indexes were correlation (r²), coherence function (Cohere) and time-frequency index (r2t,f), while a non-linear regression coefficient (h²) was used to analyze non-linear relationships. We calculated two directions during evaluate the index h2 of non-linear regression. Finally, from the entire analysis process, it is obvious that the three indexes (r2tf_rn_raw_0p2_0p4, h2_rn_raw and h2_nr_raw) were complementary ways to diagnosticate sepsis in a non-invasive way, in such delicate patients.(3) Furthermore, feasibility study is carried out on the candidate parameters selected from MC and BC respectively. We discovered that the proposed test based on optimal fusion of 6 features shows good performance with the largest Area Under Curves (AUC) and the least Probability of False Alarm (PFA). As a conclusion, we believe that the selected measures from MC and BC signal analysis have a good repeatability and accuracy to test for the diagnosis of sepsis via non-invasive NICU monitoring system, which can reliably confirm or refute the diagnosis of infection at an early stage.

Page generated in 0.0818 seconds