• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 16
  • 16
  • 9
  • 9
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Investigação do efeito de moléculas auto-organizáveis na resistência à corrosão da liga de Alumínio 1050 / Investigation on the of effect of self assembling molecules on the corrosion resistance of the 1050 aluminium alloy

Margarida Szurkalo 16 December 2009 (has links)
Tratamentos de superfície são técnicas amplamente utilizadas com a finalidade de aumentar a resistência à corrosão de materiais metálicos. No caso específico do alumínio e ligas de alumínio, o tratamento com cromo hexavalente é um dos processos mais utilizados. Isso, em razão da eficiência e da facilidade de aplicação desse processo. Entretanto, em virtude de restrições ambientais e do elevado custo de tratamento de resíduos gerados neste processo, métodos alternativos para sua substituição vêm sendo avaliados. Neste contexto, o presente estudo investigou o processo de formação e proteção à corrosão fornecida por filmes de moléculas autoorganizáveis de compostos à base de fosfonatos sobre a liga de alumínio 1050. Para definir as condições do tratamento foram utilizadas medidas de condutividade e de ângulo de contato, juntamente com ensaios eletroquímicos. Técnicas eletroquímicas, especificamente: medidas de variação do potencial a circuito aberto (PCA), espectroscopia de impedância eletroquímica (EIE) e polarização potenciodinâmica foram utilizadas para avaliar a proteção à corrosão. Os diagramas experimentais de impedância foram interpretados utilizando circuitos elétricos equivalentes que simulam modelos do filme de óxido que se forma na superfície da liga. Os resultados fornecidos com a liga tratada com moléculas auto-organizáveis foram comparados com resultados obtidos em iguais condições com amostras da liga sem qualquer tratamento ou cromatizada com Cr(VI) e mostraram que o tratamento com moléculas auto-organizáveis aumenta significativamente a resistência à corrosão da liga e apresenta, em determinadas condições, desempenho próximo ao fornecido pelo processo de cromatização. / Surface treatments are widely used to increase the corrosion resistance of metallic materials. Specifically for aluminum and aluminum alloys, treatment with hexavalent chromium is one of the most used, due to its efficiency and ease of application. However, because of environmental restrictions and the high cost involved in the treatments of waste generated in this process, alternative methods for its replacement are necessary. In this context, this study investigated the effect of the surface treatment with self-assembling molecules (SAM) based on phosphonate compounds on the corrosion of the 1050 aluminum alloy. The conditions adopted for the SAM treatment were determined by conductivity and contact angle measurements, besides electrochemical experiments. Electrochemical techniques, specifically: measurement of the open circuit potential (OCP) variation with time, electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization curves were used to evaluate the corrosion resistance of the 1050 aluminum alloy exposed to SAM treatment The experimental impedance diagrams were interpreted using equivalent electrical circuit models that simulate film that is formed on the alloy surface. The results of the samples treated with SAM were compared with those of samples either without any treatment or treated with chromatizing conversion coating with Cr(VI) and showed that the first treatment significantly increased the corrosion resistance of the aluminum alloy and approached that of chromatizing with Cr(VI) process.
12

Avaliação de biocidas no controle da corrosão microbiologicamente induzida do aço carbono 1020 por bactérias redutoras de sulfato / Evaluation of biocides on the control of microbiologically-influenced corrosion of 1020 carbon steel by sulfate-reducing bacteria

Priscila Santos da Silva 08 May 2015 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Bactérias redutoras de sulfato (BRS) são os principais micro-organismos envolvidos na corrosão microbiologicamente induzida (CMI). Estas bactérias reduzem o sulfato, tendo como resultado a produção de H2S, o que pode influenciar os processos anódico e catódico na corrosão de materiais metálicos em ambientes marinhos, óleos e solos úmidos. Uma das formas de prevenir e controlar esse tipo de corrosão é a adição de biocidas ao meio corrosivo. Esta dissertação tem como objetivo avaliar o uso de biocidas no controle da CMI do aço AISI 1020 por BRS. Para isto, o comportamento da CMI no aço foi avaliado em água do mar sintética, em condições de anaerobiose, na ausência e na presença de uma cultura mista contendo BRS. Um biocida natural (óleo de alho) e outro comercial (glutaraldeído) foram utilizados para controlar a corrosão causada por estas bactérias. Duas formas de adição de biocida foram avaliadas: antes da formação do biofilme e após sua formação na superfície do metal. O crescimento microbiano na superfície do aço foi avaliado através da quantificação das BRS sésseis, pelo método do número mais provável (NMP). O comportamento eletroquímico do aço, na ausência e na presença de BRS e também para os ensaios com biocidas, foi estudado através das técnicas de espectroscopia de impedância eletroquímica (EIE) e polarização potenciodinâmica, sempre usando água do mar sintética como meio eletrolítico. A formação de biofilme e de produtos de corrosão na superfície do aço foi observada através da microscopia eletrônica de varredura (MEV). Os resultados mostraram que o aço exposto ao meio contendo BRS apresentou um processo corrosivo mais acelerado, quando comparado aos sistemas na ausência de micro-organismo. Esse processo foi evidenciado por um decréscimo na magnitude do arco capacitivo, nos ensaios de EIE, e um aumento da densidade de corrente de corrosão (Icorr), nos ensaios de polarização. Na análise de MEV, foi possível observar a formação de corrosão localizada após a remoção do biofilme da superfície. Os ensaios com biocidas, adicionados antes da formação de biofilmes, mostraram uma redução no número de bactérias sésseis, quando comparados com os ensaios sem biocida realizados pelo mesmo período de tempo (7 dias). Foi verificado também um decréscimo do processo corrosivo do aço, evidenciado através de aumento nos arcos capacitivos, nos ensaios de EIE e pelos menores valores de Icorr nos ensaios de polarização, quando comparados com o biofilme formado sem biocidas, nas mesmas condições. Apesar de não ter inibido completamente o crescimento das BRS sésseis, o óleo de alho apresentou maior redução no processo corrosivo quando comparado ao glutaraldeído, indicando sua possível aplicação como biocida natural nestas condições. Os ensaios realizados com biocidas adicionados após a formação do biofilme mostraram que o glutaraldeído apresentou alta eficácia em reduzir o número de células sésseis. Já o óleo de alho exibiu uma ação menos efetiva, sugerindo que este composto não conseguiu penetrar completamente a matriz do biofilme. Entretanto, ambos causaram aceleração do processo corrosivo do aço no meio estudado após 7 dias de exposição / Sulfate-reducing bacteria (SRB) are the most important microorganisms involved in the microbiologically-influenced corrosion (MIC). These bacteria reduce sulfate, resulting in the production of H2S, which may influence the anodic and cathodic processes in the corrosion of metallic materials in marine environments, oil and wet soils. One way to prevent and control this type of corrosion is the addition of biocides to the corrosive environment. This work aims to evaluate the use of biocides to control MIC of AISI 1020 steel by SRB. For this, the behavior of MIC in carbon steel was evaluated in artificial seawater, under anaerobic conditions, in the absence and in the presence of a mixed culture containing SRB. A natural biocide (garlic oil) and a commercial one (glutaraldehyde) were used to control the corrosion caused by these bacteria. Two ways of biocide addition were evaluated: before the formation of biofilm and after its formation on the metal surface. Microbial growth on the steel surface was evaluated by quantifying the sessile SRB, by using the most probable number method (MPN).The electrochemical behavior of the steel in the absence and presence of SRB, as well as in the experiments containing the biocides, was studied by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization, always using artificial seawater as the electrolytic medium. The biofilm formation and the corrosion products on the steel surface were observed by scanning electron microscopy (SEM).The results showed that the steel exposed to medium containing SRB exhibited an accelerated corrosion process when compared to systems without the microorganisms. This process was evidenced by a decrease in the magnitude of the capacitive loop, in EIS experiments, and an increase of the corrosion current density (Icorr), in polarization tests. By SEM analysis, it was possible to observe the formation of localized corrosion after the biofilm removal. The experiments with biocides, added before the formation of biofilms, showed a reduction in the number of sessile bacteria, compared with the tests without biocide performed on the same time period (7 days). It was also found a decrease in steel corrosive process, evidenced by an increase in the capacitive loops in the EIS tests, and by the smaller Icorr values in polarization tests, when compared to the biofilm formatted without biocides under the same conditions. Although it has not completely inhibited the growth of BRS sessile, garlic oil showed a greater reduction in corrosion process when compared to glutaraldehyde, indicating its possible application as a natural biocide under these conditions. The experiments performed with biocides added after the biofilm formation showed that glutaraldehyde exhibited high efficacy in reducing the number of sessile cells. On the contrary, the garlic oil exhibited a less effective action, suggesting that this compound could not completely penetrate the biofilm matrix. However, both biocides accelerated the steel corrosion process in the studied medium after 7 days of exposure
13

Estudo das propriedades inibidoras de corrosão das imidazolinas oleica e quaternária e seu encapsulamento em partículas inertes. / Study of corrosion inhibiting properties of oleic and quaternary imidazolines and their encapsulation in inert particles.

Gonçalves, Adriana Cristina 11 March 2015 (has links)
Entre os inibidores de corrosão clássicos que já são utilizados na indústria do petróleo, foram estudadas a imidazolina oleica e a quaternária através de técnicas eletroquímicas, gravimétrica e analíticas, para avaliar a eficiência de inibição e como esses inibidores atuam em meio ácido. O meio agressivo foi uma solução de NaCl 3,5% em massa acidificada com ácido clorídrico até atingir um pH=2 com o objetivo de simular o ambiente de extração petrolífera. O substrato empregado foi o aço carbono 1020. As técnicas eletroquímicas utilizadas foram: monitoramento do potencial de circuito aberto, medidas de resistência de polarização linear, espectroscopia de impedância eletroquímica (EIE ) e curvas de polarização. Os valores das componentes real e imaginária de impedância indicam uma resistência maior aos processos de transferência de carga com o aumento da concentração dos inibidores e os Diagramas de Bode de ângulo de fase, revelaram a presença de uma camada de inibidor adsorvida sobre o metal com uma constante de tempo em altas frequências observada para a imidazolina oleica e quaternária. Para a imidazolina quaternária, verificou-se que só para tempos maiores de imersão é que o filme se adsorve de forma eficiente demonstrando uma cinética mais lenta de adsorção. Nos ensaios gravimétricos, os resultados de taxa de corrosão em m/ano foram decrescentes com o tempo após período de imersão de 30 dias, para ambas as imidazolinas. O uso das técnicas analíticas foi necessário a fim de se compreender melhor o comportamento das imidazolinas sobre o aço no meio estudado. Os resultados da análise de íons férricos em solução, por emissão atômica, foram obtidos durante várias amostragens durante o período do ensaio de perda de massa, e foi possível verificar um processo de inibição da corrosão até doze dias de imersão do metal, depois disto ocorre um disparo na quantidade de ferro liberado em solução, sugerindo que pode estar ocorrendo uma degradação do inibidor após 12 dias de imersão. Para esclarecer esse ponto, análises por espectroscopia Raman dos produtos de fundo formados durante os ensaios de perda de massa indicaramm que a degradação pode realmente estar ocorrendo. Foi confirmado, também por espectroscopia Raman sobre a superfície do aço após imersão prévia em solução contendo a imidazolina oleica, que há uma película adsorvida que protege o metal do meio agressivo. Técnica de microscopia eletrônica de varredura foi utilizada para caracterizar os corpos de prova na ausência e presença do inibidor, depois dos ensaios eletroquímicos e foi possível caracterizar, através dessa técnica a maior eficiência inibidora do filme de imidazolina quaternária. Dois tipos de nanoconatiners foram avaliados para o encapsulamento das duas imidazolinas estudadas: nanocontainers a base do argilomineral haloiista e sílica mesoporosa tipo SBA 15. Resultados de impedância eletroquímica mostraram a liberação dos inibidores de corrosão encapsulados com o tempo de imersão. Análise na região do infravermelho por sonda de fibra ótica foi utilizada para comprovar química e qualitativamente a liberação do inibidor a partir dos nanorreservatórios, no meio agressivo. / Among the traditional corrosion inhibitors which are already used in Oil and Gas industry, it oleic and quaternary imidazolines have been studied with electrochemical, gravimetric and analytical techniques to assess the inhibition efficiency and the inhibiting action in acidic medium. The aggressive medium was a 3.5% w/w NaCl solution acidified with hydrochloric acid to pH = 2 in order to simulate oil extraction environment. The metallic substrate used was a mild carbon steel. The electrochemical techniques used were open circuit potential monitoring the, linear polarization measurements, electrochemical impedance spectroscopy (EIS) and polarization curves. The real and imaginary components values of impedance indicated greater resistance to charge transfer processes with increasing inhibitor concentration and phase angle Bode diagrams o showed the presence of adsorbed inhibitor on the metal surface with a time constant at high frequencies observed for oleic and quaternary imidazolines. For quaternary imidazoline, it was found that only after long time of immersion the film adsorbs effectively, showing slower adsorption kinetics. In weight loss tests, the corrosion rate results decreased with time for both inhibitors. The use of analytical techniques helped to have a better understanding of both imidazolines behavior. The analysis of ferric ions in the solution by atomic emission were obtained for several electrolyte samples withdrawn during weight lost test period; it was possible to verify a efficient corrosion inhibition of carbon steel till twelve days of immersion and after that an increase on the iron release to the solution occurs , suggesting that it might be experiencing inhibitor degradation after twelve days of immersion. To clarify this point, Raman spectroscopy analysis of the sediment formed during the weight loss tests was performed and the results indicated that the degradation may actually be occurring. It was confirmed also by Raman spectroscopy analysis performed on steel surface after previous immersion in solution containing oleic imidazoline, which has adsorbed as a film which protects the metal against aggressive medium. Scanning electron microscopy was used to characterize the substrate surface morphology in the absence and presence of inhibitors after electrochemical tests. The technique has proven the presence of a persistent adsorbed quaternary imidazoline film . Two types of nanoconatiners were evaluated: halloysite clay nanocontainers and SBA-15 mesoporous silica. Electrochemical evaluation of the release of the encapsulated corrosion inhibitors was proven. IR probe technique was used to confirm chemical and quantitatively the release of the encapsulated inhibitor in the electrolyte.
14

Avaliação de biocidas no controle da corrosão microbiologicamente induzida do aço carbono 1020 por bactérias redutoras de sulfato / Evaluation of biocides on the control of microbiologically-influenced corrosion of 1020 carbon steel by sulfate-reducing bacteria

Priscila Santos da Silva 08 May 2015 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Bactérias redutoras de sulfato (BRS) são os principais micro-organismos envolvidos na corrosão microbiologicamente induzida (CMI). Estas bactérias reduzem o sulfato, tendo como resultado a produção de H2S, o que pode influenciar os processos anódico e catódico na corrosão de materiais metálicos em ambientes marinhos, óleos e solos úmidos. Uma das formas de prevenir e controlar esse tipo de corrosão é a adição de biocidas ao meio corrosivo. Esta dissertação tem como objetivo avaliar o uso de biocidas no controle da CMI do aço AISI 1020 por BRS. Para isto, o comportamento da CMI no aço foi avaliado em água do mar sintética, em condições de anaerobiose, na ausência e na presença de uma cultura mista contendo BRS. Um biocida natural (óleo de alho) e outro comercial (glutaraldeído) foram utilizados para controlar a corrosão causada por estas bactérias. Duas formas de adição de biocida foram avaliadas: antes da formação do biofilme e após sua formação na superfície do metal. O crescimento microbiano na superfície do aço foi avaliado através da quantificação das BRS sésseis, pelo método do número mais provável (NMP). O comportamento eletroquímico do aço, na ausência e na presença de BRS e também para os ensaios com biocidas, foi estudado através das técnicas de espectroscopia de impedância eletroquímica (EIE) e polarização potenciodinâmica, sempre usando água do mar sintética como meio eletrolítico. A formação de biofilme e de produtos de corrosão na superfície do aço foi observada através da microscopia eletrônica de varredura (MEV). Os resultados mostraram que o aço exposto ao meio contendo BRS apresentou um processo corrosivo mais acelerado, quando comparado aos sistemas na ausência de micro-organismo. Esse processo foi evidenciado por um decréscimo na magnitude do arco capacitivo, nos ensaios de EIE, e um aumento da densidade de corrente de corrosão (Icorr), nos ensaios de polarização. Na análise de MEV, foi possível observar a formação de corrosão localizada após a remoção do biofilme da superfície. Os ensaios com biocidas, adicionados antes da formação de biofilmes, mostraram uma redução no número de bactérias sésseis, quando comparados com os ensaios sem biocida realizados pelo mesmo período de tempo (7 dias). Foi verificado também um decréscimo do processo corrosivo do aço, evidenciado através de aumento nos arcos capacitivos, nos ensaios de EIE e pelos menores valores de Icorr nos ensaios de polarização, quando comparados com o biofilme formado sem biocidas, nas mesmas condições. Apesar de não ter inibido completamente o crescimento das BRS sésseis, o óleo de alho apresentou maior redução no processo corrosivo quando comparado ao glutaraldeído, indicando sua possível aplicação como biocida natural nestas condições. Os ensaios realizados com biocidas adicionados após a formação do biofilme mostraram que o glutaraldeído apresentou alta eficácia em reduzir o número de células sésseis. Já o óleo de alho exibiu uma ação menos efetiva, sugerindo que este composto não conseguiu penetrar completamente a matriz do biofilme. Entretanto, ambos causaram aceleração do processo corrosivo do aço no meio estudado após 7 dias de exposição / Sulfate-reducing bacteria (SRB) are the most important microorganisms involved in the microbiologically-influenced corrosion (MIC). These bacteria reduce sulfate, resulting in the production of H2S, which may influence the anodic and cathodic processes in the corrosion of metallic materials in marine environments, oil and wet soils. One way to prevent and control this type of corrosion is the addition of biocides to the corrosive environment. This work aims to evaluate the use of biocides to control MIC of AISI 1020 steel by SRB. For this, the behavior of MIC in carbon steel was evaluated in artificial seawater, under anaerobic conditions, in the absence and in the presence of a mixed culture containing SRB. A natural biocide (garlic oil) and a commercial one (glutaraldehyde) were used to control the corrosion caused by these bacteria. Two ways of biocide addition were evaluated: before the formation of biofilm and after its formation on the metal surface. Microbial growth on the steel surface was evaluated by quantifying the sessile SRB, by using the most probable number method (MPN).The electrochemical behavior of the steel in the absence and presence of SRB, as well as in the experiments containing the biocides, was studied by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization, always using artificial seawater as the electrolytic medium. The biofilm formation and the corrosion products on the steel surface were observed by scanning electron microscopy (SEM).The results showed that the steel exposed to medium containing SRB exhibited an accelerated corrosion process when compared to systems without the microorganisms. This process was evidenced by a decrease in the magnitude of the capacitive loop, in EIS experiments, and an increase of the corrosion current density (Icorr), in polarization tests. By SEM analysis, it was possible to observe the formation of localized corrosion after the biofilm removal. The experiments with biocides, added before the formation of biofilms, showed a reduction in the number of sessile bacteria, compared with the tests without biocide performed on the same time period (7 days). It was also found a decrease in steel corrosive process, evidenced by an increase in the capacitive loops in the EIS tests, and by the smaller Icorr values in polarization tests, when compared to the biofilm formatted without biocides under the same conditions. Although it has not completely inhibited the growth of BRS sessile, garlic oil showed a greater reduction in corrosion process when compared to glutaraldehyde, indicating its possible application as a natural biocide under these conditions. The experiments performed with biocides added after the biofilm formation showed that glutaraldehyde exhibited high efficacy in reducing the number of sessile cells. On the contrary, the garlic oil exhibited a less effective action, suggesting that this compound could not completely penetrate the biofilm matrix. However, both biocides accelerated the steel corrosion process in the studied medium after 7 days of exposure
15

Estudo das propriedades inibidoras de corrosão das imidazolinas oleica e quaternária e seu encapsulamento em partículas inertes. / Study of corrosion inhibiting properties of oleic and quaternary imidazolines and their encapsulation in inert particles.

Adriana Cristina Gonçalves 11 March 2015 (has links)
Entre os inibidores de corrosão clássicos que já são utilizados na indústria do petróleo, foram estudadas a imidazolina oleica e a quaternária através de técnicas eletroquímicas, gravimétrica e analíticas, para avaliar a eficiência de inibição e como esses inibidores atuam em meio ácido. O meio agressivo foi uma solução de NaCl 3,5% em massa acidificada com ácido clorídrico até atingir um pH=2 com o objetivo de simular o ambiente de extração petrolífera. O substrato empregado foi o aço carbono 1020. As técnicas eletroquímicas utilizadas foram: monitoramento do potencial de circuito aberto, medidas de resistência de polarização linear, espectroscopia de impedância eletroquímica (EIE ) e curvas de polarização. Os valores das componentes real e imaginária de impedância indicam uma resistência maior aos processos de transferência de carga com o aumento da concentração dos inibidores e os Diagramas de Bode de ângulo de fase, revelaram a presença de uma camada de inibidor adsorvida sobre o metal com uma constante de tempo em altas frequências observada para a imidazolina oleica e quaternária. Para a imidazolina quaternária, verificou-se que só para tempos maiores de imersão é que o filme se adsorve de forma eficiente demonstrando uma cinética mais lenta de adsorção. Nos ensaios gravimétricos, os resultados de taxa de corrosão em m/ano foram decrescentes com o tempo após período de imersão de 30 dias, para ambas as imidazolinas. O uso das técnicas analíticas foi necessário a fim de se compreender melhor o comportamento das imidazolinas sobre o aço no meio estudado. Os resultados da análise de íons férricos em solução, por emissão atômica, foram obtidos durante várias amostragens durante o período do ensaio de perda de massa, e foi possível verificar um processo de inibição da corrosão até doze dias de imersão do metal, depois disto ocorre um disparo na quantidade de ferro liberado em solução, sugerindo que pode estar ocorrendo uma degradação do inibidor após 12 dias de imersão. Para esclarecer esse ponto, análises por espectroscopia Raman dos produtos de fundo formados durante os ensaios de perda de massa indicaramm que a degradação pode realmente estar ocorrendo. Foi confirmado, também por espectroscopia Raman sobre a superfície do aço após imersão prévia em solução contendo a imidazolina oleica, que há uma película adsorvida que protege o metal do meio agressivo. Técnica de microscopia eletrônica de varredura foi utilizada para caracterizar os corpos de prova na ausência e presença do inibidor, depois dos ensaios eletroquímicos e foi possível caracterizar, através dessa técnica a maior eficiência inibidora do filme de imidazolina quaternária. Dois tipos de nanoconatiners foram avaliados para o encapsulamento das duas imidazolinas estudadas: nanocontainers a base do argilomineral haloiista e sílica mesoporosa tipo SBA 15. Resultados de impedância eletroquímica mostraram a liberação dos inibidores de corrosão encapsulados com o tempo de imersão. Análise na região do infravermelho por sonda de fibra ótica foi utilizada para comprovar química e qualitativamente a liberação do inibidor a partir dos nanorreservatórios, no meio agressivo. / Among the traditional corrosion inhibitors which are already used in Oil and Gas industry, it oleic and quaternary imidazolines have been studied with electrochemical, gravimetric and analytical techniques to assess the inhibition efficiency and the inhibiting action in acidic medium. The aggressive medium was a 3.5% w/w NaCl solution acidified with hydrochloric acid to pH = 2 in order to simulate oil extraction environment. The metallic substrate used was a mild carbon steel. The electrochemical techniques used were open circuit potential monitoring the, linear polarization measurements, electrochemical impedance spectroscopy (EIS) and polarization curves. The real and imaginary components values of impedance indicated greater resistance to charge transfer processes with increasing inhibitor concentration and phase angle Bode diagrams o showed the presence of adsorbed inhibitor on the metal surface with a time constant at high frequencies observed for oleic and quaternary imidazolines. For quaternary imidazoline, it was found that only after long time of immersion the film adsorbs effectively, showing slower adsorption kinetics. In weight loss tests, the corrosion rate results decreased with time for both inhibitors. The use of analytical techniques helped to have a better understanding of both imidazolines behavior. The analysis of ferric ions in the solution by atomic emission were obtained for several electrolyte samples withdrawn during weight lost test period; it was possible to verify a efficient corrosion inhibition of carbon steel till twelve days of immersion and after that an increase on the iron release to the solution occurs , suggesting that it might be experiencing inhibitor degradation after twelve days of immersion. To clarify this point, Raman spectroscopy analysis of the sediment formed during the weight loss tests was performed and the results indicated that the degradation may actually be occurring. It was confirmed also by Raman spectroscopy analysis performed on steel surface after previous immersion in solution containing oleic imidazoline, which has adsorbed as a film which protects the metal against aggressive medium. Scanning electron microscopy was used to characterize the substrate surface morphology in the absence and presence of inhibitors after electrochemical tests. The technique has proven the presence of a persistent adsorbed quaternary imidazoline film . Two types of nanoconatiners were evaluated: halloysite clay nanocontainers and SBA-15 mesoporous silica. Electrochemical evaluation of the release of the encapsulated corrosion inhibitors was proven. IR probe technique was used to confirm chemical and quantitatively the release of the encapsulated inhibitor in the electrolyte.
16

AVALIAÇÃO DO DESEMPENHO DE CONCRETOS COM ADIÇÕES MINERAIS QUANTO À CORROSÃO DAS ARMADURAS INDUZIDA POR CLORETOS / Performance evaluation of concretes content with mineral additions in relation to the reinforcing steels corrosion induced by chlorides

OLIVEIRA, Andrielli Morais de 29 August 2007 (has links)
Made available in DSpace on 2014-07-29T15:03:38Z (GMT). No. of bitstreams: 1 dissertacao Adrielli.pdf: 5370662 bytes, checksum: 4e167ff0f119f9298b4d7ed2791baa06 (MD5) Previous issue date: 2007-08-29 / The present work aims to study the performance of concrete with regard to the action of chloride ions, evaluating the influence of both mineral additions and water/binder ratio (w/b), considering kinetic and thermodynamic aspects of the corrosive phenomenon. A experimental research was carried out considering the following variables: the presence of mineral additions in partial substitution to the cement weight (10% of silica fume; 25% of fly ash; 10%, 20% and 30% of metakaolin) and the water/binder ratio (0,40 and 0,55). Thus, cubic concrete test specimens were produced, in addition to cylindrical test specimens for concrete characterization in relation to the compressive strength, specific mass, void ratio and capillary water absorption. After 645 days of casting, the cubic concrete test specimens were submitted to the chlorides attack during 308 days, totality 44 weekly cycles of immersion in chlorides aggressive solution. They were monitored, throughout this period, by means of techniques, such as: the concrete electric resistivity, the half-cell potential, the polarization resistance and the electrochemical impedance spectroscopy. At the end of the experiment, visual inspections of reinforcing steels allowed to observe their superficial aspects after attack. As general result, it was gotten that the incorporation of mineral additions to the concretes promoted significant profits in all the evaluated properties, evidencing the beneficial effect of these additions in concretes exposed to aggressive conditions, specially in those in which there are chloride ions. In this direction, the statistical analysis has shown evidences that concretes with silica fume and metakaolin achieved the best results of electrical resistivity. In relation to the half-cell potentials, the reference concrete (without mineral additions) presented the worst performance, with an indication of despassivation in the reinforcing steels accentuated fall in the values of resistance of polarization with the time, proving the susceptibility of these systems to the action of chlorides. The concrete with mineral additions did not present depassivation of the reinforcing steels meaning that these systems possess great durability and service life in relation to those without mineral additions / O presente trabalho tem como objetivo estudar o desempenho de concretos quanto à ação de íons cloreto, avaliando tanto a interveniência das adições minerais incorporadas ao concreto quanto da relação água/aglomerante (a/ag), considerando aspectos cinéticos e termodinâmicos do fenômeno corrosivo. Para tanto, desenvolveu-se uma pesquisa experimental que contemplou as seguintes variáveis: a presença de adições minerais em substituição parcial à massa de cimento (10% de sílica ativa; 25% de cinza volante; 10%, 20% e 30% de metacaulim) e a relação água/aglomerante (0,40 e 0,55). Foram moldados corpos-de-prova cúbicos, além de corpos-de-prova cilíndricos para caracterização dos concretos quanto à resistência à compressão, massa específica, índice de vazios e absorção de água por capilaridade. Após 645 dias de moldagem, os corpos-de-prova cúbicos de concreto foram submetidos ao ataque por cloretos durante 308 dias, totalizando 44 ciclos semanais de imersão em solução agressiva e posterior secagem em ambiente de laboratório. Foram monitorados, ao longo deste período, a resistividade elétrica desses concretos, os potenciais de corrosão, a resistência de polarização e a impedância eletroquímica. Ao fim do experimento, inspeções visuais à armadura permitiram observar o seu aspecto superficial após o período de ataque. Como resultado geral, obteve-se que a incorporação de adições minerais aos concretos promoveu ganhos significativos em todas as propriedades avaliadas, evidenciando o efeito benéfico dessas adições em concretos submetidos às condições agressivas, sobretudo contendo íons cloreto. Nesse sentido, a análise estatística evidenciou que os concretos com sílica ativa e com metacaulim obtiveram os melhores resultados de resistividade elétrica. Quanto aos potenciais de corrosão, os concretos de referência (sem adições minerais) apresentaram desempenho inferior, com a indicação da despassivação das armaduras e a queda acentuada nos valores de resistência de polarização com o tempo, comprovando a susceptibilidade desses sistemas à ação de cloretos. Os concretos com adições minerais não apresentaram despassivação das armaduras, denotando que esses sistemas possuem maior durabilidade e vida útil em comparação àqueles referentes aos concretos sem adição mineral, tendo em vista o ataque por cloretos
17

Avaliação da capacidade de proteção contra a corrosão da arma-dura induzida por cloretos de concretos com adições minerais e inibidores de corrosão / Evaluation of the ability to protect against corrosion of the gun hard-induced chloride concrete with mineral additions and corrosion inhibitors

LIMA, Marcelo Batista 28 September 2009 (has links)
Made available in DSpace on 2014-07-29T15:18:24Z (GMT). No. of bitstreams: 1 pretextual.pdf: 140883 bytes, checksum: 5d9ee4b9b3884a0032825e604304580f (MD5) Previous issue date: 2009-09-28 / Increasing the durability of concrete structural elements is primordial, especially those related to power generation in eolic areas that are subjected to the phenomenon of reinforcement corrosion. In this context, this study aims to evaluate the overall protection ability of concrete to the phenomenon of reinforcement corrosion induced by chlorides. To this end, it was adopted a statistical program based on a fractional factorial design in which the variables studied were as follows: the water-binder ratio (0.35, 0.45 and 0.55), the type of mineral admixture (silica fume and blast furnace slag at specific levels), the type of corrosion inhibitor (calcium nitrite, sodium nitrite and amine) and the level of corrosion inhibitor (minimum and maximum recommended by each manufacturer). In the concrete investigations, the tests performed were corrosion potential, polarization resistance and electrochemical impedance. Throughout the experiments, it was possible to testify the beneficial effect of reducing the water-binder ratio. It was also possible to prove the very positive effect of the incorporation of mineral admixtures, especially of silica fume. The satisfactory performance of various inhibitors evaluated was also verified, specially when concrete contains mineral admixtures. A parallel study was conducted to make a comparative analysis of inhibitors at the same range of concentrations (at solid levels of 0.76%, 2.21% and 3.66% of the compound on the cement mass), nevertheless this study have demonstrated that fixing contents for all inhibitor is not appropriated, and the recommended dosages by the manufacturer is the best condition. As the levels recommended by manufacturers, it was found that the higher percentages have not worked well for sodium nitrite otherwise, for amine and nitrite calcium, the higher levels implied better results. Regarding the tannin inhibitor also assessed in the parallel study mentioned above (related to specific inhibitors), its good performance related to corrosion inhibition happened just for the content of 0.76% (the lowest levels). For the other contents, it was verified anomalous results. These results demonstrated that each type of corrosion inhibitor has its optimal concentration for use in concrete. Based on a cost-benefit analysis and evaluating the increase in the concrete value for cubic meter (in R$) in the presence of inhibitors at the same contents, it was verified a relative parity prices among the tested nitrites and an extremely high cost of amine. However, when performing the same analysis but using the levels recommended by the manufacturers for each inhibitor independent, it was found that the large disparity in prices between nitrite and amine was reduced considerably. An assessment of technical and economic feasibility was also performed based on the efficiency of corrosion inhibition and cost per cubic meter of concrete mixtures that did not show a typical depassivation of their stell bar up to the attack age evaluated / O aumento da durabilidade é um aspecto primordial para os elementos estruturais de concreto, em especial aqueles constituintes das estruturas de geração de energia em parques eólicos, sujeitos ao fenômeno de corrosão das armaduras. Nesse contexto, este trabalho tem como objetivo geral avaliar a capacidade de proteção de diferentes concretoS frente ao fenômeno da corrosão da armadura induzida por cloretos. Para tanto, foi adotado um planejamento estatístico baseado em um modelo fatorial fracionado em que as variáveis estudadas foram: a relação água/aglomerante (0,35; 0,45 e 0,55), o tipo de adição mineral (sílica ativa e escória de alto-forno, em teores específicos), o tipo de inibidor de corrosão (nitrito de cálcio, nitrito de sódio e amina) e o teor de inibidor de corrosão (mínimo e máximo recomendado por cada fabricante). Na avaliação dos concretos, foram realizados ensaios de potencial de corrosão, resistência de polarização e impedância eletroquímica. Ao longo de todo experimento foi possível constatar o efeito benéfico da redução da relação a/agl. Também foi possível verificar o efeito extremamente positivo da incorporação das adições minerais, em especial da sílica ativa. Constatou-se também o efeito positivo dos diversos inibidores avaliados, em seus teores mínimo e máximo, beneficio que se mostrou mais pronunciado quando da utilização conjunta com as adições minerais. Um estudo paralelo foi realizado para se fazer uma análise comparativa dos inibidores dentro da mesma faixa de teores empregados (teores de 0,76%; 2,21% e 3,66% de sólidos do aditivo em relação à massa de cimento), no qual se verificou que a utilização desses teores fixos para os diferentes tipos de inibidores não se mostrou tão eficiente quanto em relação à utilização dos aditivos na dosagem de recomendação do fabricante. Quanto a estes teores (recomendados pelos fabricantes), verificou-se que os percentuais mais altos não funcionaram bem para o nitrito de sódio, ao passo que para a amina e para o nitrito de cálcio os teores mais elevados resultaram em melhores resultados. Em relação ao tanino, inibidor que também foi avaliado no estudo paralelo referido anteriormente (específico sobre os inibidores), só houve algum resultado de inibição de corrosão para o teor de 0,76% (mais baixo dos teores), tendo-se obtido resultados anômalos para os outros 2 teores mais altos. Tais resultados permitiram constatar que cada tipo de inibidor de corrosão possui sua concentração ótima de utilização no concreto. Fazendo-se uma análise de custo e avaliando-se o acréscimo em Reais no valor do m3 do concreto proporcionado pelos diversos aditivos inibidores e nos teores de mesma faixa de emprego, verificou-se uma relativa paridade de preços entre os nitritos e um elevadíssimo custo da amina. No entanto, ao se realizar a mesma análise, mas utilizando os teores recomendados pelos fabricantes de cada inibidor, verificou-se que a grande disparidade de preços entre os nitritos e a amina foi reduzida de forma considerável. Uma avaliação da viabilidade técnico-econômica dos concretos também foi realizada, a partir dos dados de eficiência de inibição à corrosão e custo/m3 das misturas que não apresentaram comportamento típico de despassivação de suas armaduras até a idade de ataque considerada
18

DETERMINAÇÃO DE ÁCIDO α-LIPÓICO EMPREGANDO TÉCNICAS ELETROQUÍMICAS E ANÁLISE POR INJEÇÃO EM BATELADA / DETERMINATION OF α-LIPOIC ACID EMPLOYING ELECTROCHEMICAL TECHNIQUES AND ANALYSIS BY INJECTION IN BATCH

Pereira, Laise Nayra dos Santos 18 July 2014 (has links)
Made available in DSpace on 2016-08-19T12:56:48Z (GMT). No. of bitstreams: 1 Dissertacao LAISE NAYRA DOS SANTOS PEREIRA.pdf: 1329578 bytes, checksum: bb0923e1ddc2d57bb73b2390b4ceb375 (MD5) Previous issue date: 2014-07-18 / FUNDAÇÃO DE AMPARO À PESQUISA E AO DESENVOLVIMENTO CIENTIFICO E TECNOLÓGICO DO MARANHÃO / This work describes the development of electroanalytical procedures for α-lipoic acid (ALA) determination in dietary supplement using a pyrolitic graphite electrode (PG) modified with cobalt phthalocyanine (CoPc) from electrochemical techniques and by Batch Injection Analysis (BIA). Cyclic voltammograms of ALA oxidation on the PG/ CoPc electrode presented an irreversible peak ~+0.85 V vs Ag/ AgCl, a value about 100 mV to less positive potential, well as a significant increase in the magnitude of peak current compared to the PG electrode unmodified. The analytical curves obtained with cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry showed good linearity and sensitivity. The DPV technique showed the best values of limit of detection (LOD) and quantification (LOQ) 3.4 x 10ˉ⁹ mol Lˉ¹ and 1.2 x 10ˉ⁸ mol Lˉ¹, respectively. Therefore was chosen for determination of ALA on technique. Voltammetric response of ALA was also evaluated in PG electrode unimodified and modified in hydrodynamic conditions. The modification of the PG/ CoPc electrode produced an increase of 2.33 times compared to the PG electrode. The analytical method was then proposed using the PG/ CoPc electrode for detection of ALA by BIA. The method showed a good linear range between (1.0 x 10ˉ⁶ to 1.0 x 10ˉ⁴ mol Lˉ¹), values of LOD and LOQ of 1.5 × 10ˉ⁸ mol Lˉ¹ and 5.0 × 10ˉ⁸ mol L-1, respectively, with analytical frequency of 208 injections/ hour. The quantification of ALA in dietary supplement showed concordant results with those obtained by chromatographic method, with a confidence level of 95%. Recovery tests were performed added a concentration of ALA in a sample of synthetic urine, where the recovery values were in the range 98 - 107%. / O presente trabalho descreve o desenvolvimento de procedimentos eletroanalíticos para determinação de ácido α-lipóico (ALA) em suplemento dietético utilizando eletrodo de grafite pirolítico (GP) modificado com ftalocianina de cobalto (CoPc) a partir de técnicas eletroquímicas e pela Análise por Injeção em Batelada (BIA). Os voltamogramas cíclicos da oxidação de ALA sobre o eletrodo GP/ CoPc apresentaram um pico irreversível com potencial ~ +0,85 V vs. Ag/ AgCl, mostrando um deslocamento do início da corrente de oxidação em cerca de 100 mV para potenciais menos positivos, bem como um aumento significativo na magnitude da corrente de pico, quando comparados ao eletrodo não modificado GP. As curvas analíticas obtidas com as técnicas de voltametria cíclica (VC), voltametria de pulso diferencial (VPD) e cronoamperometria apresentaram boa linearidade e sensibilidade. A técnica de VPD apresentou os melhores valores de limite de detecção (LD) e de quantificação (LQ), 3,4 x 10ˉ⁹ mol Lˉ¹ e 1,2 x 10ˉ⁸ mol Lˉ¹, respectivamente. Portanto foi a técnica escolhida para determinação de ALA. Resposta voltamétrica do ALA também foi avaliada no eletrodo GP não modificado e modificado em condições hidrodinâmicas. A modificação do eletrodo GP/ CoPc produziu um aumento de 2,33 vezes comparado com o eletrodo GP. O método analítico foi então proposto usando o eletrodo GP/ CoPc para detecção de ALA por BIA. O método apresentou uma boa faixa linear compreendida entre (1 x 10ˉ⁶ a 1 x 10ˉ⁴ mol Lˉ¹); valores de LD e LQ de 1, 5 x 10ˉ⁸ mol Lˉ¹ e 5, 0 x 10ˉ⁸ mol Lˉ¹, respectivamente, com frequência analítica de 208 injeções/ hora. A quantificação de ALA em suplemento dietético apresentou resultados concordantes com os obtidos pelo método cromatográfico, apresentando um nível de confiança de 95%. Testes de recuperação foram feitos adicionados uma concentração de ALA em amostra de urina sintética, onde os valores de recuperação foram na faixa de 98 a 107%.

Page generated in 0.0757 seconds