Tappvarmvattenanvändning i idrottsanläggningar : Mätning av sannolikt flöde / Tap hot water use in sports facilities : Measuring the dimensioning flow

Vikström, Jimmy January 2017 (has links)
För bostäder finns det underlag och rekommendationer om sannolikt flöde för tappvarmvatten. Underlag saknas för idrottsanläggningar där flera personer går och duschar samtidigt, efter t.ex. en lagaktivitet eller idrottslektion. Problem för projektörer idag är att de inte vet hur stort tappvarmvattenflöde de kan förvänta sig, detta slutar ofta i överdimensionerad effekt på värmeväxlaren och överdimensionerade komponenter. Syftet med examensarbetet har varit att genom flödesmätningar på fyra idrottsanläggningar, utreda om det går att påvisa något samband och arbeta fram ett underlag för att beräkna sannolikt flöde vid olika antal tappställen i idrottsanläggningar.   Mätningar har utförts på tre sporthallar av varierande storlek och ett badhus i Luleå regionen. Sporthallarna har 91,39 och 32 tappställen, badhuset har 28 tappställen. Mätningarna har skett över en och två veckors perioder och har utförts med en ultraljudsmätare med en minuts samplingsintervall. Mätdata för varje fastighet har utvärderats för att sedan sammanställas till två ekvationer som ska fungera som underlag vid framtida projekteringar för sporthallar, och en ekvation för badhus. Rekommendationerna ska vara behjälpliga vid dimensionering av sannolikt flöde, effekt för värmeväxlare och styrventil för fjärrvärmen.   För badhus rekommenderas det sannolika flödet att beräknas med nedanstående ekvation. Där  är antalet duschar i allmänna omklädningsrum.  är normalflödet för duschblandarna i de allmänna omklädningsrummen. Om centralblandare finns i fastigheten kan  sättas till 0,085 l/s.  är det sannolika flödet för resterande tappställen i fastigheten och beräknas med en väl etablerad projekteringsmetod.   För sporthallar har två ekvationer tagits fram från mätdata. En som relaterar det sannolika flödet mot antal duschar i allmänna omklädningsrum, en som relaterar mot totala antalet tappställen i fastigheten. Projektören får själv avgöra vad det kommer vara för verksamhet i fastigheten och bestämma vad som passar bäst som underlag. Ovanstående ekvation är kopplad till allmänna duschar. Där x är antal duschar i de allmänna utrymmena.               Ovanstående ekvation är kopplad till totala antalet tappställen i fastigheten. Där x är antal tappställen i fastigheten som förbrukar tappvarmvatten. / For residential buildings there are equations and guidelines how to calculate the dimensioning flow for tap hot water. These types of calculation methods however does not exist for sports facilities where a large group of people shower simultaneously, for example, after a sport activity or a physical education lecture. The problem today is that the engineers doesn’t know exactly how to estimate the dimensioning flow, therefore the existing methods often results in over dimensioned heat exchangers and valves. The purpose with this bachelor thesis is to perform flow measurements on four sport facilities of different sizes. Determine if there are any correlation between them, and elaborate guidelines on how to estimate the dimensioning flow with different number of tap valves in the facilities.   Measurements have been made on three sport auditoriums and one public bath. The sport auditoriums have 91, 39 and 32 tap valves each, and the public bath has 28 tap valves. The measuring period is one and two weeks for the facilities and the flow measurement instrument is an ultrasonic flowmeter with a sampling interval of one minute. Measurement data for each facility have been evaluated and then compiled into two equations that will function as guidelines for sport auditoriums, and one equation that will function as guideline for public baths. These recommendations will be helpful when dimensioning the tap hot water flow and the power of the heat exchanger and dimensioning the adjusting valve for the district heating hot water.   For public baths the equation below should work as a guideline to dimension the tap hot water flow, where  is the number of tap places for showering in the public dressing rooms, and  is the normal tap water flow from the mixers in the public dressing rooms. If there is a central thermostatic mixing valve in the facility,  can be set to 0,085 l/s.  is the dimensioning flow for the rest of the tap water valves in the facility and is calculated with a well-entrenched method. For sport auditorium two equations will work as guidelines to dimension the tap hot water flow. One equation is correlated to the amount of shower tap valves in the public dressing rooms, and the other one is correlated to the total amount of tap places in the facility.                The equation above is correlated to the amount of showers in the public dressing rooms, where  is the amount of tap places for showering in the public dressing rooms.                 The equation above is correlated to the amount of tap places in the facility, where  is the total amount of tap places that uses tap hot water in the facility.

Page generated in 0.0803 seconds