Spelling suggestions: "subject:"tartaric""
1 |
Hidrogeno tartarato de potássio sob condições extremasAraújo, Eduardo Barbosa January 2010 (has links)
ARAÚJO, Eduardo Barbosa. Hidrogeno tartarato de potássio sob condições extremas. 2010. 91 f. Dissertação (Mestrado em Física) - Programa de Pós-Graduação em Física, Departamento de Física, Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by Edvander Pires (edvanderpires@gmail.com) on 2015-05-04T17:58:37Z
No. of bitstreams: 1
2010_dis_ebaraujo.pdf: 6842726 bytes, checksum: a872faa8cf9ba2f66e40a844c820a22e (MD5) / Approved for entry into archive by Edvander Pires(edvanderpires@gmail.com) on 2015-05-07T14:48:41Z (GMT) No. of bitstreams: 1
2010_dis_ebaraujo.pdf: 6842726 bytes, checksum: a872faa8cf9ba2f66e40a844c820a22e (MD5) / Made available in DSpace on 2015-05-07T14:48:41Z (GMT). No. of bitstreams: 1
2010_dis_ebaraujo.pdf: 6842726 bytes, checksum: a872faa8cf9ba2f66e40a844c820a22e (MD5)
Previous issue date: 2010 / Cristais de hidrogeno tartarato de potássio (KHT) foram estudados por Análise Térmica – Calorimetria Diferencial de Varredura (DSC) e Análise Termogravimétrica (TGA) – e espectroscopia Raman com a variação de parâmetros termodinâmicos na região espectral entre 30 e 3400 cm-1. A classificação dos modos foi feita com base em compostos similares. Os estudos de DSC foram realizados no intervalo de temperatura de 90 a 671 K enquanto os de TG entre 303 a 573 K. Os experimentos de espectroscopia Raman foram realizados entre as temperaturas de 10 a 448 K. Os resultados revelaram que o material apresenta uma estrutura termicamente estável durante todo o intervalo estudado até a sua decomposição (próxima a 520 K) que ocorre sem fusão. Os experimentos com altas pressões (0,0 a 6,5 GPa) revelaram indícios fortes de que o material sofre uma transição de fase próxima a 2,4 GPa e uma segunda transição próxima a 6,3 GPa. Mudanças na região dos modos da rede dão suporte à afirmação. Modos relacionados à unidade CO2- apresentaram mudanças em seu comportamento nesses valores de pressão. As mudanças ocorridas se mostraram reversíveis com a redução à pressão ambiente.
|
2 |
Hidrogeno tartarato de potÃssio sob condiÃÃes extremas.Eduardo Barbosa AraÃjo 20 July 2010 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Cristais de hidrogeno tartarato de potÃssio (KHT) foram estudados por AnÃlise TÃrmica â Calorimetria Diferencial de Varredura (DSC) e AnÃlise TermogravimÃtrica (TGA) â e espectroscopia Raman com a variaÃÃo de parÃmetros termodinÃmicos na regiÃo espectral entre 30 e 3400 cm-1. A classificaÃÃo dos modos foi feita com base em compostos similares. Os estudos de DSC foram realizados no intervalo de temperatura de 90 a 671 K enquanto os de TG entre 303 a 573 K. Os experimentos de espectroscopia Raman foram realizados entre as temperaturas de 10 a 448 K. Os resultados revelaram que o material apresenta uma estrutura termicamente estÃvel durante todo o intervalo estudado atà a sua decomposiÃÃo (prÃxima a 520 K) que ocorre sem fusÃo. Os experimentos com altas pressÃes (0,0 a 6,5 GPa) revelaram indÃcios fortes de que o material sofre uma transiÃÃo de fase prÃxima a 2,4 GPa e uma segunda transiÃÃo prÃxima a 6,3 GPa. MudanÃas na regiÃo dos modos da rede dÃo suporte à afirmaÃÃo. Modos relacionados à unidade CO2- apresentaram mudanÃas em seu comportamento nesses valores de pressÃo. As mudanÃas ocorridas se mostraram reversÃveis com a reduÃÃo à pressÃo ambiente.
|
3 |
Desenvolvimento e validação de métodos analíticos para determinação simultânea de fármacos que atuam no controle da hipertensão arterial / Development and validation of analytical methods for simultaneous determination of drugs that act on the control of hypertension.Oliveira, Claudia Vilela de 13 April 2015 (has links)
A hipertensão arterial é um fator de risco de alta prevalência para as doenças cardiovasculares, principalmente no mundo industrializado, aumentando o problema de saúde em virtude do aumento da longevidade e da prevalência de fatores contribuintes como obesidade, sedentarismo e dietas inadequadas. Estima-se que 10% das 55 milhões de mortes que acontecem a cada ano, são consequências da hipertensão arterial. Dois terços desses eventos ocorrem nos países em desenvolvimento, incluindo o Brasil, afetando principalmente a população de menor nível socioeconômico. Diuréticos como hidroclorotiazida associados a betabloqueadores como o metoprolol são exemplos de fármacos utilizados no controle da hipertensão. O presente trabalho teve como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação simultânea do tartarato de metoprolol e da hidroclorotiazida por eletroforese capilar (CE) e por cromatografia líquida de ultra eficiência (UHPLC). Para a definição das melhores condições de análise e determinação simultânea dos analitos em estudo, e otimização do método, utilizou-se metodologia de superfície de resposta (ou Response Surface Methodology - RSM). O método por CE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50 µm d.i. O tampão utilizado foi tetraborato de sódio 25,0 mmol L-1, injeção hidrodinâmica 0,5 psi/6s, tensão aplicada +15 kV, detecção em 225 nm temperatura a 25ºC. O tartarato de metoprolol e hidroclorotiazida foram separados em 1,2 e 2,1 min, respectivamente .O método por UHPLC foi realizado empregando uma coluna ZORBAX® SB C18 (50 mm x 2,1 mm x 1,8 µm), fase móvel constituída por água:acetornitrila:trietilamina (83:17:0,2 v/v/v), pH 3 ajustado com ácido fosfórico, utilizou vazão de 0,9 mL min-1. A hidroclorotiazida e o tartarato de metoprolol foram separados em 0,7 e 1,0 min, respectivamente. Os métodos analíticos foram validados de acordo com os requerimentos da ANVISA, ICH e Farmacopéia Americana. Os métodos apresentaram boa linearidade com coeficiente de correlação maiores que 0.99, a precisão intra- e inter-day para os tempos de migração foi apropriada (DPR < 2%), a exatidão do método foi comprovada mediante teste de recuperação, obtendo-se valores de 100±2. Portanto, os métodos propostos demonstraram ser lineares, precisos, exatos e rápidos para quantificação simultânea da hidroclorotiazida e do tartarato de metoprolol. E podem ser considerados confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos. / Hypertension is a risk factor of high prevalence for cardiovascular diseases, especially in the industrialized world, increasing health problems as a result of increased longevity and the prevalence of contributing factors such as obesity, physical inactivity and inadequate diets. It is estimated that 10% of 55 million deaths that occur each year, are consequences of hypertension. Two-thirds of those events occur in developing countries, including Brazil, affecting mainly the population from lower socioeconomic backgrounds. Diuretics like hydrochlorothiazide associated with beta-blockers such as metoprolol tartrate are examples of drugs used in the control of hypertension. The present work had as objective to develop, validate and compare analytical methods for identification and simultaneous quantification of metoprolol tartrate and hydrochlorothiazide by capillary electrophoresis (CE) and ultra performance liquid chromatography (UHPLC). For the definition of the best conditions of analysis and simultaneous determination of drugs in study, and optimization of the method, it was used response surface methodology (RSM or \"Response Surface Methodology). The CE method used a fused silica capillary with total length of 30.2 cm x 50 µm d.i. The electrolyte used was sodium tetraborate 25,0 mmol L-1, hydrodynamic injection 0.5 psi/6s, applied voltage +15 kV, detection in 225 nm temperature at 25ºC. The metoprolol tartrate and hydrochlorothiazide were separated into 1.2 and 2.1 min, respectively. The UHPLC method was carried out employing a ZORBAX SB® C18 (50 mm x 2.1 mm x 1.8 µm) column, mobile phase consisting of water: acetornitrila: triethylamine (83: 17: 0.2 v/v/v), 3 pH adjusted with phosphoric acid, the flow was 0.9 mL min-1. Hydrochlorothiazide and metoprolol tartrate were separated in 0.7 and 1.0 min, respectively. The analytical methods have been validated in accordance with the requirements of ANVISA, ICH and American Pharmacopoeia. The methods showed good linearity with correlation coefficient greater than 0.99, precision inter and intra day for times of migration was appropriate (DPR < 2%), the accuracy of the method has been proven by recovery test, obtaining values of 100 ± 2. Therefore, the proposed methods have shown to be linear, precise, accurate and fast for simultaneous quantification of hydrochlorothiazide and metoprolol tartrate; and can be considered reliable to be used in routine analysis for quality control of pharmaceutical products.
|
4 |
Desenvolvimento e validação de métodos analíticos para determinação simultânea de fármacos que atuam no controle da hipertensão arterial / Development and validation of analytical methods for simultaneous determination of drugs that act on the control of hypertension.Claudia Vilela de Oliveira 13 April 2015 (has links)
A hipertensão arterial é um fator de risco de alta prevalência para as doenças cardiovasculares, principalmente no mundo industrializado, aumentando o problema de saúde em virtude do aumento da longevidade e da prevalência de fatores contribuintes como obesidade, sedentarismo e dietas inadequadas. Estima-se que 10% das 55 milhões de mortes que acontecem a cada ano, são consequências da hipertensão arterial. Dois terços desses eventos ocorrem nos países em desenvolvimento, incluindo o Brasil, afetando principalmente a população de menor nível socioeconômico. Diuréticos como hidroclorotiazida associados a betabloqueadores como o metoprolol são exemplos de fármacos utilizados no controle da hipertensão. O presente trabalho teve como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação simultânea do tartarato de metoprolol e da hidroclorotiazida por eletroforese capilar (CE) e por cromatografia líquida de ultra eficiência (UHPLC). Para a definição das melhores condições de análise e determinação simultânea dos analitos em estudo, e otimização do método, utilizou-se metodologia de superfície de resposta (ou Response Surface Methodology - RSM). O método por CE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50 µm d.i. O tampão utilizado foi tetraborato de sódio 25,0 mmol L-1, injeção hidrodinâmica 0,5 psi/6s, tensão aplicada +15 kV, detecção em 225 nm temperatura a 25ºC. O tartarato de metoprolol e hidroclorotiazida foram separados em 1,2 e 2,1 min, respectivamente .O método por UHPLC foi realizado empregando uma coluna ZORBAX® SB C18 (50 mm x 2,1 mm x 1,8 µm), fase móvel constituída por água:acetornitrila:trietilamina (83:17:0,2 v/v/v), pH 3 ajustado com ácido fosfórico, utilizou vazão de 0,9 mL min-1. A hidroclorotiazida e o tartarato de metoprolol foram separados em 0,7 e 1,0 min, respectivamente. Os métodos analíticos foram validados de acordo com os requerimentos da ANVISA, ICH e Farmacopéia Americana. Os métodos apresentaram boa linearidade com coeficiente de correlação maiores que 0.99, a precisão intra- e inter-day para os tempos de migração foi apropriada (DPR < 2%), a exatidão do método foi comprovada mediante teste de recuperação, obtendo-se valores de 100±2. Portanto, os métodos propostos demonstraram ser lineares, precisos, exatos e rápidos para quantificação simultânea da hidroclorotiazida e do tartarato de metoprolol. E podem ser considerados confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos. / Hypertension is a risk factor of high prevalence for cardiovascular diseases, especially in the industrialized world, increasing health problems as a result of increased longevity and the prevalence of contributing factors such as obesity, physical inactivity and inadequate diets. It is estimated that 10% of 55 million deaths that occur each year, are consequences of hypertension. Two-thirds of those events occur in developing countries, including Brazil, affecting mainly the population from lower socioeconomic backgrounds. Diuretics like hydrochlorothiazide associated with beta-blockers such as metoprolol tartrate are examples of drugs used in the control of hypertension. The present work had as objective to develop, validate and compare analytical methods for identification and simultaneous quantification of metoprolol tartrate and hydrochlorothiazide by capillary electrophoresis (CE) and ultra performance liquid chromatography (UHPLC). For the definition of the best conditions of analysis and simultaneous determination of drugs in study, and optimization of the method, it was used response surface methodology (RSM or \"Response Surface Methodology). The CE method used a fused silica capillary with total length of 30.2 cm x 50 µm d.i. The electrolyte used was sodium tetraborate 25,0 mmol L-1, hydrodynamic injection 0.5 psi/6s, applied voltage +15 kV, detection in 225 nm temperature at 25ºC. The metoprolol tartrate and hydrochlorothiazide were separated into 1.2 and 2.1 min, respectively. The UHPLC method was carried out employing a ZORBAX SB® C18 (50 mm x 2.1 mm x 1.8 µm) column, mobile phase consisting of water: acetornitrila: triethylamine (83: 17: 0.2 v/v/v), 3 pH adjusted with phosphoric acid, the flow was 0.9 mL min-1. Hydrochlorothiazide and metoprolol tartrate were separated in 0.7 and 1.0 min, respectively. The analytical methods have been validated in accordance with the requirements of ANVISA, ICH and American Pharmacopoeia. The methods showed good linearity with correlation coefficient greater than 0.99, precision inter and intra day for times of migration was appropriate (DPR < 2%), the accuracy of the method has been proven by recovery test, obtaining values of 100 ± 2. Therefore, the proposed methods have shown to be linear, precise, accurate and fast for simultaneous quantification of hydrochlorothiazide and metoprolol tartrate; and can be considered reliable to be used in routine analysis for quality control of pharmaceutical products.
|
Page generated in 0.0316 seconds