• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 13
  • 12
  • 8
  • 8
  • 7
  • 7
  • 7
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Resolução do problema de Riemann através de um método variacional

Percca, Edwin Marcos Maraví 20 February 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-11T14:36:03Z No. of bitstreams: 1 edwinmarcosmaravipercca.pdf: 1012447 bytes, checksum: f4600cdbca54aedbb08335b949e92788 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-17T20:09:05Z (GMT) No. of bitstreams: 1 edwinmarcosmaravipercca.pdf: 1012447 bytes, checksum: f4600cdbca54aedbb08335b949e92788 (MD5) / Made available in DSpace on 2017-04-17T20:09:05Z (GMT). No. of bitstreams: 1 edwinmarcosmaravipercca.pdf: 1012447 bytes, checksum: f4600cdbca54aedbb08335b949e92788 (MD5) Previous issue date: 2017-02-20 / As leis de balanço expressam de uma maneira mais geral as leis de conservação e, portanto, é natural que coincidam em algumas definições ou resultados que vamos mostrar aqui. Um sistema de leis de conservação estritamente hiperbólico numa dimensão espacial sob certas condições é um sistema simetrizável, portanto, possui uma entropia convexa. Isto induz a definiroparentropia-fluxodeentropiaeaproduçãodeentropia,ingredientesmínimospara usar o critério de admissibilidade da taxa de entropia e conferir se a solução do problema de Riemann respectivo é ótimo. A taxa de entropia definida aqui em termos da entropia é um funcional que pode ser minimizada nos leques de ondas com estados constantes do problema de Riemann, usando as equações de Euler-Lagrange. Primeiramente, mostramos que as soluções do problema de Riemann são funções de variação limitada, resultando num método variacional para resolver o problema. Neste trabalho será mostrado que a solução obtida pelo método variacional, coincide com a solução obtida pelo método das curvas caraterísticas. / The balance laws express in a more general way the conservation laws and therefore it is naturalthattheycoincideinsomedefinitionsorresultsthatwewillshowhere. Thestrictly hyperbolic systems of conservation laws in a spatial dimension under certain conditions is a symmetrizable system, therefore it has a convex entropy. This induces to define the entropy-entropy flux pair and the entropy production, minimum ingredients to use the Entropy rate admissibility criterion and check whether the solution of the respective Riemann problem is optimal. The entropy rate defined here in terms of entropy is a functional that can be minimized in the wave fans with constant states of the Riemann problem using the Euler-Lagrange equations, we show that the solutions of the Riemann problem are functions of bounded variation, resulting in a variational method to solve the respective problem. In this work it will be shown that the solution obtained by the variational method, coincides with the solution obtained by the method of characteristics.
12

Modelagem computacional de funções de proteção baseadas em medidas de frequência para detecção de ilhamento de geração distribuída / Computational modeling of frequency-based protection functions for distributed generation islanding detection

Motter, Daniel 28 January 2014 (has links)
O ilhamento em sistemas elétricos contendo geração distribuída ocorre quando parte da rede elétrica torna-se eletricamente isolada da concessionária e o subsistema isolado continua a ser energizado por geradores distribuídos. É importante detectar essa condição, que pode, por exemplo, levar a problemas como alteração da qualidade da energia elétrica e religamento automático fora de sincronismo, causando danos irreversíveis aos equipamentos da rede elétrica. Uma forma de detecção do ilhamento é o uso de funções de proteção de frequência e suas variações, tais como a função de taxa de variação de frequência e a função de deslocamento de fase (ou salto de vetor). Neste contexto, é importante que se tenham modelos computacionais e analíticos confiáveis dessas funções de proteção para que sejam executadas simulações, permitindo validar ajustes e verificar condições anormais de operação. O objetivo desta dissertação é desenvolver e validar modelos computacionais e analíticos das funções de proteção de sub/sobre frequência, taxa de variação de frequência e deslocamento de fase, empregados na detecção de ilhamento de geradores distribuídos. Os modelos computacionais são desenvolvidos em uma plataforma que permite realizar simulações dinâmicas em tempo real. A validação dos modelos é efetuada utilizando funções de proteção existentes em relés comerciais. A avaliação de desempenho dos modelos em relação à proteção anti-ilhamento é realizada utilizando o conceito das curvas de desempenho, as quais foram obtidas a partir de simulações computacionais em tempo real e em malha fechada pelo uso de um simulador digital em tempo real. Os resultados permitem comprovar a efetividade dos modelos para representar as funções de proteção dos relés comerciais ensaiados, com erros abaixo de 3% para uma ampla faixa de pontos de operação do sistema elétrico e do gerador distribuído. / Islanding in power distribution systems with distributed generators occurs when part of the electrical network becomes isolated from the electrical company and the isolated area is still energized by distributed generation. It is important to detect this condition which can lead to problems such as low power quality levels and out of step reclosing, causing severe equipment damages. One of the island detection methods is the use of frequency protection functions and their variations, such as the rate of change of frequency relay and phase shift relay (or vector surge relay). In this context, it is important to obtain reliable relay computational and analytical models to execute simulations that allow verifying and validating settings, and investigating abnormal operation conditions. This dissertation aims to develop and validate computational and analytical models of under and over frequency, rate of change of frequency and phase shift protection functions applied to distributed generation islanding detection. The computational model development is performed on a real time dynamic simulation platform. The model validations are performed using protection functions of commercial relays. The models performance evaluation and validation were carried out by using the performance curves, which are obtained through real time closed loop simulations using a real time digital simulator. The results prove the model effectiveness to represent commercial protection functions, with errors below 3% for a wide range of distribution system and distributed generator operating conditions.
13

Modelagem computacional de funções de proteção baseadas em medidas de frequência para detecção de ilhamento de geração distribuída / Computational modeling of frequency-based protection functions for distributed generation islanding detection

Daniel Motter 28 January 2014 (has links)
O ilhamento em sistemas elétricos contendo geração distribuída ocorre quando parte da rede elétrica torna-se eletricamente isolada da concessionária e o subsistema isolado continua a ser energizado por geradores distribuídos. É importante detectar essa condição, que pode, por exemplo, levar a problemas como alteração da qualidade da energia elétrica e religamento automático fora de sincronismo, causando danos irreversíveis aos equipamentos da rede elétrica. Uma forma de detecção do ilhamento é o uso de funções de proteção de frequência e suas variações, tais como a função de taxa de variação de frequência e a função de deslocamento de fase (ou salto de vetor). Neste contexto, é importante que se tenham modelos computacionais e analíticos confiáveis dessas funções de proteção para que sejam executadas simulações, permitindo validar ajustes e verificar condições anormais de operação. O objetivo desta dissertação é desenvolver e validar modelos computacionais e analíticos das funções de proteção de sub/sobre frequência, taxa de variação de frequência e deslocamento de fase, empregados na detecção de ilhamento de geradores distribuídos. Os modelos computacionais são desenvolvidos em uma plataforma que permite realizar simulações dinâmicas em tempo real. A validação dos modelos é efetuada utilizando funções de proteção existentes em relés comerciais. A avaliação de desempenho dos modelos em relação à proteção anti-ilhamento é realizada utilizando o conceito das curvas de desempenho, as quais foram obtidas a partir de simulações computacionais em tempo real e em malha fechada pelo uso de um simulador digital em tempo real. Os resultados permitem comprovar a efetividade dos modelos para representar as funções de proteção dos relés comerciais ensaiados, com erros abaixo de 3% para uma ampla faixa de pontos de operação do sistema elétrico e do gerador distribuído. / Islanding in power distribution systems with distributed generators occurs when part of the electrical network becomes isolated from the electrical company and the isolated area is still energized by distributed generation. It is important to detect this condition which can lead to problems such as low power quality levels and out of step reclosing, causing severe equipment damages. One of the island detection methods is the use of frequency protection functions and their variations, such as the rate of change of frequency relay and phase shift relay (or vector surge relay). In this context, it is important to obtain reliable relay computational and analytical models to execute simulations that allow verifying and validating settings, and investigating abnormal operation conditions. This dissertation aims to develop and validate computational and analytical models of under and over frequency, rate of change of frequency and phase shift protection functions applied to distributed generation islanding detection. The computational model development is performed on a real time dynamic simulation platform. The model validations are performed using protection functions of commercial relays. The models performance evaluation and validation were carried out by using the performance curves, which are obtained through real time closed loop simulations using a real time digital simulator. The results prove the model effectiveness to represent commercial protection functions, with errors below 3% for a wide range of distribution system and distributed generator operating conditions.

Page generated in 0.0586 seconds