• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A High Speed Transceiver Front-end Design with Fault Detection and Temperature Detector for FlexRay-based Automotive Communication Systems

Yeh, Tai-Hao 17 August 2011 (has links)
This thesis is composed of two parts: a high-speed transceiver front-end design with fault detection for FlexRay-based automative communication systems, and a temperature detector. In the first topic, a high-speed transceiver design with a fault detection circuit compliant with FlexRay standards V2.1 is proposed and realized on silicon. According to FlexRay physical layer standards, a LVDS-like transmitter is utilized to drive the twisted pair to generate a pair of differential signals. By contrast, a three-comparator-based receiver will recover the signals and then detect the mode of the bus. A failure detector is added at the transmitter to detect the operating current magnitude to avoid any over-current hazard. Meanwhile, a short-circuit detector is added at the receiver to detect short-circuit faults to vdd or gnd. The second topic discloses a temperature detector circuit, particularly dedicated for the reliability of any in-car system by sensing the temperature and the process at the same time. A discharging circuit composed of four PMOS transistors discharges until the output voltage is stable. It is composed of several reference voltages and comparators to determine the range of temperature and process. Eventually, by identifying the process corner and the temperature range, the reliability and safty of the car electrics will be ensured.
2

Capteur de gaz SnO2 fonctionnalisé fonctionnant à température ambiante, sensible et sélectif pour la détection d’ammoniac / Sensitive and selective ammonia gas sensor based on molecularly functionalized tin dioxide working at room temperature

Hijazi, Mohamad 20 October 2017 (has links)
Dans le domaine de la santé, l’analyse de l'haleine expirée offre un outil simple et non invasif pour le diagnostic précoce des maladies. Les capteurs de gaz à base de SnO2 modifies semblent être des dispositifs prometteurs pour détecter les gaz polaires tels que l'ammoniac. Dans cette étude, la fonctionnalisation de la surface de SnO2 a été réalisée afin d'obtenir un capteur de gaz sensible et sélectif à l'ammoniac, qui fonctionne à température ambiante. La première étape de la fonctionnalisation est la fixation covalente d’un film de 3-aminopropyltrethoxysalane (APTES) sur SnO2 en phase vapeur ou liquide. Les caractérisations effectuées par Spectroscopie Infrarouge et Spectrométrie photoélectronique X montrent qu’une quantité plus importante d'APTES a été greffée en phase liquide hydratée. La deuxième étape consiste à fonctionnaliser le SnO2-APTES avec des molécules contenant du chlorure d'acyle avec différents groupes tel que des groupes alkyle, acide et ester. Les capteurs modifiés par des acides et des esters sont sensibles à l’ammoniac entre 0,2 et 10 ppm à température ambiante. Cependant, le SnO2 APTES modifié par l’ester s'est révélé être plus sélectif que le capteur modifié par l'acide pour l’ethanol et le mondxyde de carbone. Ces résultats impliquent que la réponse est générée par les groupes fonctionnels acide et ester, NH3 modifie le moment dipolaire de la couche moléculaire greffée, ce qui entraine une modification de la conductance de SnO2. Le fonctionnement à température ambiante est l'un des avantages de ces capteurs, tout comme leur sélectivité à l'ammoniac en regard d'autres gaz tels que l'éthanol, le monoxyde de carbone et l'acétone. / One of the major challenges in the modern era is how we can detect the disease when we are still feeling healthy via noninvasive methods. Exhaled breath analysis is offering a simple and noninvasive tool for early diagnosis of diseases. Molecularly modified SnO2 sensors seem to be promising devices for sensing polar gases such as ammonia. SnO2 surface functionalization was performed in order to obtain sensitive and selective ammonia gas sensor that operates at room temperature. The first step of functionalization is the covalently attachment of 3-aminopropyltriethoxysilane (APTES) film on SnO2 in vapor or liquid phases. The characterization performed by the Infrared Spectroscopy and X-ray Photoelectron Spectroscopy, show that more APTES were grafted by hydrous liquid phase silanization. The second step was the functionalization of APTES modified SnO2 with molecules having acyl chloride of end functional groups molecules such as alkyl, acid and ester groups. Pure SnO2 and APTES modified SnO2 sensors did not show any significant sensitivity to ammonia (0.2-100 ppm) at 25 °C. On the contrary, acid and ester modified sensors are sensitive to ammonia between 0.2 and 10 ppm at room temperature. However, ester modified SnO2 was more selective than acid modified sensor regarding the ethanol and carbon monoxide gases. Ammonia variates the attached molecular layer’s dipole moment which leads to change in SnO2 conductance. Working at ambient temperature is also one of the advantages of these sensors in addition to the selectivity to ammonia regarding other gases such as ethanol, carbon monoxide and acetone.
3

Convergence of Artificial Intelligence and Smart City: Ethical Perspective : Case Study of Helsingborg City Artificial Intelligent application for temperature detection

Grechina, Anna January 2022 (has links)
Convergence of novel technologies with smart cities is evolving now. Specifically Artificial Intelligence (AI) by means of sensors and cameras is used to make sense of city data for multiple purposes. Recent COVID-19 pandemic has shown that cities worldwide try to use AI technology for assisting in decision making and see the impact of certain socio-economic measures of city authorities in connection to pandemic. This thesis is a Qualitative study of a Helsingborg city AI application project for temperature detection by means of thermal sensors located on Helsingborg, Sweden central station for anonymous measuring of people temperature. Specifically, this study aims to understand how aware are project team members of the ethical considerations in connection to AI application for health detection in smart city of Helsingborg, related decision making and how they perceive it.   Data was gathered by means of Qualitative interviews which were hold online. This study has shown that convergence of AI and a smart city raises important ethical questions and perceived by some respondents as possibility to change the attitude towards privacy if connected to crisis events such as pandemics. The case study shows that in the researched AI project project team members considered ethics in connection to AI in terms of technology, legal issues, open collaboration and open data sharing with citizens. At the same time this project is willing to challenge existing norms and drive forward the development of ethics in connection to AI usage in a smart city.
4

Monitoring teploty / Temperature Monitoring

Kotačka, Aleš January 2008 (has links)
This master's thesis deals use FITkit for longtime temperature monitoring without necessity connection on PC. Describe possibilities connection different heat-sensitive elements to FITkit inclusive physical realization. Further this thesis deals with measuring of temperature, displaying temperature and saving to memory, blocks-partitioning of memory. Is defined communication protocol between FITkit and PC for bulk downloading of data. So are solving problems with saving measure data to text files and next processing in table processors.
5

Ανάπτυξη παθητικών συστημάτων μελέτης ενδοκρανιακών θερμοκρασιακών μεταβολών και εγκεφαλικών διεργασιών

Καραθανάσης, Κωνσταντίνος 20 October 2010 (has links)
Η ανίχνευση με τη χρήση μικροκυμάτων παίζει πολύ σημαντικό ρόλο στην τεχνολογική εξέλιξη του κόσμου τα τελευταία 50 χρόνια. Από τα ραντάρ μέχρι τη Μικροκυματική Ραδιομετρία, η ανίχνευση με τη χρήση μικροκυμάτων έχει χρησιμοποιηθεί για έναν αυξανόμενο αριθμό εφαρμογών σε διάφορα επιστημονικά πεδία, μεταξύ των οποίων η χαρτογράφηση του εδάφους, ο καθορισμός της υγρασίας του εδάφους, η θερμογραφία και η ανίχνευση του καρκίνου του μαστού. Έτσι, οι μικροκυματικοί αισθητήρες, διαθέτοντας την ικανότητα να διαπερνούν πολλά είδη μέσων (πχ. σύννεφα, βιολογικοί ιστοί), έχουν μια σημαντική θέση ανάμεσα σε άλλες τεχνικές μέτρησης. Η Μικροκυματική Ραδιομετρία αποτελεί ένα σημαντικό τομέα της επιστημονικής έρευνας και εφαρμογής της ανίχνευσης με τη χρήση μικροκυμάτων, καθώς αποτελεί μια παθητική μέθοδο ανίχνευσης της φυσικά εκπεμπόμενης χαοτικής θερμικής ακτινοβολίας από κάθε σώμα που βρίσκεται σε θερμοκρασία άνω του απόλυτου μηδενός (-273 Κελσίου). Ένα μικροκυματικό ραδιόμετρο είναι η συσκευή που χρησιμοποιείται για τη διεξαγωγή ραδιομετρικών μετρήσεων. Η ραδιομετρία έχει αποτελέσει ένα σημαντικό τομέα έρευνας όχι μόνο για την αξιολόγηση της ατμόσφαιρας και της επιφάνειας της γης, αλλά και για την περαιτέρω διερεύνηση των παθητικών μετρήσεων, με σημαντικές εφαρμογές ειδικά στον τομέα της βιοϊατρικής. Στα πλαίσια της παρούσας Διδακτορικής Διατριβής μελετήθηκε σε θεωρητικό και πειραματικό επίπεδο η βελτιστοποίηση των ιδιοτήτων ανίχνευσης ενός Τρισδιάστατου Συστήματος Παθητικής Μικροκυματικής Ραδιομετρικής Απεικόνισης για διαγνωστικές εφαρμογές εγκεφάλου. Η καινοτομία της προτεινόμενης μεθόδου έγκειται στη χρήση μιας αγώγιμης ελλειψοειδούς κοιλότητας που δρα σαν μορφοποιητής δέσμης, ώστε να επιτευχθεί μέγιστη συγκέντρωση και εστίαση της ακτινοβολίας που εκπέμπει το φυσικό σώμα ενδιαφέροντος, σε συνδυασμό με ευαίσθητους ραδιομετρικούς δέκτες και ομοιοκατευθυντικές κεραίες λήψης στο φάσμα συχνοτήτων 1 – 4 GHz. Η μέτρηση πραγματοποιείται με την τοποθέτηση του ανθρώπινου εγκεφάλου στην περιοχή της πρώτης εστίας και τη λήψη της ακτινοβολίας που συγκλίνει, μέσω ανάκλασης στα τοιχώματα του ελλειψοειδούς, στη δεύτερη εστία. Εκεί είναι τοποθετημένη η κεραία λήψης που συνδέεται στον ευαίσθητο ραδιομετρικό δέκτη. VI Με σκοπό τη βελτίωση των ιδιοτήτων εστίασης του συστήματος, πραγματοποιήθηκε η μοντελοποίησή του και ακολούθησε εκτενής ηλεκτρομαγνητική μελέτη για την ανάλυση της επίδρασης διατάξεων προσαρμογής από κατάλληλα υλικά στο εσωτερικό της ελλειψοειδούς κοιλότητας. Τα αποτελέσματα δείχνουν πως με τη σωστή επιλογή των υλικών και των ιδιοτήτων τους, είναι δυνατό να επιτευχθεί σημαντική βελτίωση του βάθους ανίχνευσης του κατωφλίου ανίχνευσης θερμοκρασίας και της χωρικής διακριτικής ικανότητας του συστήματος. Τα πειράματα με ομοιώματα που πραγματοποιήθηκαν, επαληθεύουν τις βασικές αρχές λειτουργίας του συστήματος καθώς επίσης και την ευεργετική επίδραση των διατάξεων προσαρμογής στις ιδιότητες εστίασής του, που μελετήθηκαν θεωρητικά στο πρώτο στάδιο της έρευνας,. Τέλος, οι πειραματικές διαδικασίες, που σχεδιάστηκαν με βάση πιθανές κλινικές εφαρμογές του συστήματος, δείχνουν ότι έχει βασικά χαρακτηριστικά και ιδιότητες ώστε να αποτελέσει στο μέλλον κλινικό, διαγνωστικό εργαλείο. / Microwave sensing has played an increasingly significant role in the world’s technological advances over the past 50 years. From radar to radiometry, microwave sensing has been used for a large number of applications, including ground mapping, soil moisture determination, thermography, and breast cancer detection. With the ability to safely penetrate many kinds of media (e.g., clouds or biological specimens), microwave sensors find a significant place among other modalities of measurement. Microwave radiometry is an important scientific research and application area of microwave sensing because it provides a passive sensing technique for detecting naturally emitted chaotic thermal radiation by any material object being above the absolute zero temperature (-273 Celsius). A microwave radiometer is the device used to conduct radiometric measurements. While radiometry has been a significant research field for atmospheric and earth surface evaluations, it lends itself to further exploration of passive measurements, with significant applications especially in the biomedical field. In the framework of the present PhD Thesis, a theoretical and experimental optimization study of the sensing capabilities of a Three Dimensional Passive Microwave Radiometry Imaging System for brain diagnostic applications was performed. The novelty of the proposed methodology consists in the use of a conductive ellipsoidal cavity acting as a beamformer to achieve maximum peak of radiation pattern in order to measure the intensity of the microwave energy, radiated by the medium of interest, by using sensitive microwave radiometers and relevant non – contacting antennas within the range of 1 – 4 GHz. The measurement is realized by placing the human brain in the region of the first focus and collecting the radiation converged at the second focus by a receiving antenna connected to the sensitive radiometer. Towards the improvement of the system’s focusing properties, extended electromagnetic analysis was performed in order to validate the impact of matching configurations made from appropriate materials, located inside the ellipsoidal cavity. The results show that with the appropriate choice of materials and careful assessment of their properties, it is possible to significantly improve the system’s detection depth, temperature detection level and spatial sensitivity. VIII The experimental procedures that were performed verify the proof of concept and confirm the beneficial impact of matching configurations on the system’s focusing properties, which was theoretically studied in the first part of the research. Finally, the experimental set used in the study, related to possible clinical applications, produced promising results regarding the potential perspective of the system to serve as a future clinical diagnostic tool.

Page generated in 0.7106 seconds