• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

SPÄNNKABLAR I REAKTORINNESLUTNINGEN : Utredning kring olika konstruktionstyper av Reaktorinneslutningar / Pre-stressed cables in the Reactor Containment : Investigation of different structure types of reactor containments

Al-Mukdadi, Saja, Khaleda, Yeasmeen January 2014 (has links)
Frågor kring kärnkraftverk har alltid varit ett omdiskuterat ämne. Kärnkraftens betydelse varierar stort mellan olika länder. Av 441 reaktorer i världen tillhör 10 av dem till Sverige. Kärnkraftverk i Oskarshamn är en av dem. Företaget OKG har beslutat att genomföra en övergripande utredning kring olika konstruktionstyper av reaktorinneslutningar med detta examensarbete. Arbetet begränsas till att göra en litteraturundersökning. En viss genomgång av både nationella och internationella rapporter har gjorts. Det primära syftet med detta examensarbete är uppdelat i två huvuddelar. Den första delen av utredningen visar olika konstruktionstyper av reaktorinneslutning i hela världen. Den andra delen visar de reaktorinneslutningarna som har en liknande konstruktion som på OKG d.v.s. betong som är förspänd med cementinjekterade spännkablar. En liknande konstruktion finns bl.a. i Finland och Frankrike. Vi har också diskuterat kontroller för andra konstruktionstyper där spännkablarna är omgivna av luft eller fettinjekterade. I utredningen redovisas en del inträffade skador och incidenter i Svenska och utländska kärnkraftverk reaktorer. Företaget har två övriga frågeställningar som undersöktes i senare skedet av arbetsgång. Spännkrafter minskar med tiden på grund av krympning och krypning i spännarmerade konstruktioner vilket påverkar säkerheten av konstruktionen negativt. Som en del av detta arbete utfördes undersökningar om det finns metoder att bestämma spännkrafter där spännkablarna inte är åtkomliga. I det slutliga skedet av utredningen undersöktes metoder som Trafikverket följer för att kontrollera sina broar d.v.s. utföra huvudinspektioner/ besiktningar. Huvudsyftet av examensarbetet har uppfyllts men vissa delar är begränsade på grund av mesta informationer av olika kärnkraftverk är konfidentiella och inte tillgängliga på nätet. Och alla våra undersökningar var webbaserade som innebär att vi hade inte möjlighet att hitta rätt informationer direkt från webben. Samtidigt kontakta de olika utländska kärnkraftverken var inte så lätt på kort varsel. Strålsäkerhetsmyndighet (SSM) hjälpte oss att få kontaktinformation av 3 olika länder. I slutet av rapporten ges analys och diskussion kring utredningen. / Questions regarding Nuclear Power Plants have always been a controversial subject. Nuclear power's importance varies between countries. Of the 441 reactors in the world 10 of them belongs to Sweden. Oskarshamn Nuclear Power Plant is one of them. OKG has decided to conduct a comprehensive investigation of this thesis work around some issues. The main purpose of this thesis work is to make a literature investigation about bracing cables in reactor containment. A specific review of national and international reports has been made and formed a collective basis with the company issues. The introductory part of this thesis is divided into two main parts. The first review of this report considers different structural types of reactor containment in the world. Most nuclear reactors are enclosed by a pre-stressed concrete containment and some have steel reactor containment. In both Sweden and Finland, the enclosure is designed as a concrete cylinder, which is pre-stressed both vertically and horizontally. The second review describes about those reactor containments, which has a similar construction to the OKG (the tendons are placed in the casing that after chucking was injected with cement mortar). A similar construction can be found in Finland and France. The investigation also reveals the damage and accidents in Swedish and foreign nuclear power reactors in recent years. Furthermore, company has two other issues, which were implemented in the later stages of the work. Due to shrinkage and creep in the concrete and relaxation in the tendons, the prestressed capacity decreases with time which affects the structure negatively. The objective of this thesis is to investigate if there are methods for determining tensile forces where the tendons are not accessible. Methods are divided into two different types: one is cement grouting method, same as OKG and another one is oil-injection method. The final review of report is to investigate about TRAFIKVERKET methods to check/inspection the bridges. It can be concluded that the main expectations of this thesis has been fulfilled but some parts are still missing due to limitation of proper information. To contact with the various foreign nuclear power plants was not so easy within this short time. All our experiments were web-based and there were many confidential matters which is unreachable. Swedish Radiation Safety authority (SSM) helped us to get contact details of 3 different countries. The discussions about the reviews are summarized at the end of the report.
2

Quantification of Achilles tendon force and triceps surae muscle energy production during human locomotion / Consideration of monoarticular and biarticular mechanisms

Kharazi, Mohamadreza 25 August 2023 (has links)
Aktuelle In-vivo-Methoden zur Bewertung der Belastung und Dehnung der Achillessehne (AT) in der biomechanischen Literatur haben bestimmte Einschränkungen, die sorgfältig berücksichtigt werden müssen. Daher hatte die erste Studie zum Ziel, die AT-Dehnung und -Kraft während der Fortbewegung mithilfe einer genauen, nicht-invasiven Methode zu messen. Die Länge der AT wurde unter Berücksichtigung ihrer Krümmung mit reflektierenden Folienmarkern von der Insertion am Fersenbein bis zum Übergang zwischen der Muskel-Sehnen-Verbindung des Musculus gastrocnemius medialis (GM-MTJ) gemessen. Die Kraft der AT wurde durch Anpassung einer quadratischen Funktion an die experimentelle Kraft-Längen-Kurve der Sehne ermittelt, die aus maximalen freiwilligen isometrischen Kontraktionen (MVC) gewonnen wurde. Die Ergebnisse der zweiten Studie zeigen, dass eine Erhöhung der Gehgeschwindigkeit zu einer 21%igen Abnahme der maximalen AT-Kraft bei höheren Geschwindigkeiten im Vergleich zur bevorzugten Geschwindigkeit führt, während die Nettobelastung der AT-Kraft am Sprunggelenk (ATF-Arbeit) in Abhängigkeit von der Gehgeschwindigkeit zunimmt. Darüber hinaus trugen eine frühere Plantarflexion, erhöhte elektromyografische Aktivität der Muskeln Sol und GM sowie der Energieübertrag von Knie- zu Sprunggelenk durch die biartikulären Musculi gastrocnemii zu einer 1,7- bzw. 2,4-fachen Zunahme der netto ATF-Mechanik-Arbeit bei Übergangs- und maximalen Gehgeschwindigkeiten bei. Das Ziel der dritten Studie war es, die in der ersten Studie vorgeschlagene Methode zu vereinfachen, indem die Anzahl der reflektierenden Folienmarker reduziert wurde, jedoch die hohe Genauigkeit beibehalten wurde. Die Krümmung der AT wurde mithilfe von reflektierenden Folienmarkern zwischen dem Ursprung des GM-MTJ und dem Einführungsmarker am Fersenbein beurteilt. Unsere Ergebnisse zeigen, dass eine Reduzierung der Anzahl der Folienmarker um 70% beim Gehen und um 50% beim Laufen zu einem marginalen Fehler führen würde und somit einen vernachlässigbaren Effekt auf die Länge der AT und die maximale Dehnungsmessung hätte. / Current in vivo methods to assess the Achilles tendon (AT) strain and loading in the biomechanics literature have certain limitations that require careful consideration. Therefore, the first study was to measure the AT strain and quantify AT force during locomotion with an accurate non-invasive method. AT length was measured considering its curvature using reflective foil markers from AT insertion at calcaneus to gastrocnemius medialis muscle-tendon junction (GM-MTJ). The force of the AT was calculated by fitting a quadratic function to the experimental tendon force-length curve obtained from maximum voluntary isometric contractions (MVC). The findings in second study indicate that an increase in walking speed leads to a 21% decrease in maximum AT force at higher speeds compared to the preferred speed, yet the net work of the AT force at the ankle joint (ATF-work) increased as a function of walking speed. Additionally, an earlier plantar flexion, increased electromyographic activity of the Sol and GM muscles, and knee-to-ankle joint energy transfer via the biarticular gastrocnemii contributed to a 1.7 and 2.4-fold increase in the net ATF-mechanical work in the transition and maximum walking speeds. The objective of the third study was to simplify the proposed method in the first study by reducing the number of foil reflective markers while preserving high accuracy. The AT curvature was assessed using reflective foil markers between the GM-MTJ origin and the calcaneal insertion marker. Our results indicate that reducing the number of foil markers by 70% during walking and 50% during running would result in a marginal error and, thus, a negligible effect on the AT length and maximum strain measurement.

Page generated in 0.0765 seconds