• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

SPÄNNKABLAR I REAKTORINNESLUTNINGEN : Utredning kring olika konstruktionstyper av Reaktorinneslutningar / Pre-stressed cables in the Reactor Containment : Investigation of different structure types of reactor containments

Al-Mukdadi, Saja, Khaleda, Yeasmeen January 2014 (has links)
Frågor kring kärnkraftverk har alltid varit ett omdiskuterat ämne. Kärnkraftens betydelse varierar stort mellan olika länder. Av 441 reaktorer i världen tillhör 10 av dem till Sverige. Kärnkraftverk i Oskarshamn är en av dem. Företaget OKG har beslutat att genomföra en övergripande utredning kring olika konstruktionstyper av reaktorinneslutningar med detta examensarbete. Arbetet begränsas till att göra en litteraturundersökning. En viss genomgång av både nationella och internationella rapporter har gjorts. Det primära syftet med detta examensarbete är uppdelat i två huvuddelar. Den första delen av utredningen visar olika konstruktionstyper av reaktorinneslutning i hela världen. Den andra delen visar de reaktorinneslutningarna som har en liknande konstruktion som på OKG d.v.s. betong som är förspänd med cementinjekterade spännkablar. En liknande konstruktion finns bl.a. i Finland och Frankrike. Vi har också diskuterat kontroller för andra konstruktionstyper där spännkablarna är omgivna av luft eller fettinjekterade. I utredningen redovisas en del inträffade skador och incidenter i Svenska och utländska kärnkraftverk reaktorer. Företaget har två övriga frågeställningar som undersöktes i senare skedet av arbetsgång. Spännkrafter minskar med tiden på grund av krympning och krypning i spännarmerade konstruktioner vilket påverkar säkerheten av konstruktionen negativt. Som en del av detta arbete utfördes undersökningar om det finns metoder att bestämma spännkrafter där spännkablarna inte är åtkomliga. I det slutliga skedet av utredningen undersöktes metoder som Trafikverket följer för att kontrollera sina broar d.v.s. utföra huvudinspektioner/ besiktningar. Huvudsyftet av examensarbetet har uppfyllts men vissa delar är begränsade på grund av mesta informationer av olika kärnkraftverk är konfidentiella och inte tillgängliga på nätet. Och alla våra undersökningar var webbaserade som innebär att vi hade inte möjlighet att hitta rätt informationer direkt från webben. Samtidigt kontakta de olika utländska kärnkraftverken var inte så lätt på kort varsel. Strålsäkerhetsmyndighet (SSM) hjälpte oss att få kontaktinformation av 3 olika länder. I slutet av rapporten ges analys och diskussion kring utredningen. / Questions regarding Nuclear Power Plants have always been a controversial subject. Nuclear power's importance varies between countries. Of the 441 reactors in the world 10 of them belongs to Sweden. Oskarshamn Nuclear Power Plant is one of them. OKG has decided to conduct a comprehensive investigation of this thesis work around some issues. The main purpose of this thesis work is to make a literature investigation about bracing cables in reactor containment. A specific review of national and international reports has been made and formed a collective basis with the company issues. The introductory part of this thesis is divided into two main parts. The first review of this report considers different structural types of reactor containment in the world. Most nuclear reactors are enclosed by a pre-stressed concrete containment and some have steel reactor containment. In both Sweden and Finland, the enclosure is designed as a concrete cylinder, which is pre-stressed both vertically and horizontally. The second review describes about those reactor containments, which has a similar construction to the OKG (the tendons are placed in the casing that after chucking was injected with cement mortar). A similar construction can be found in Finland and France. The investigation also reveals the damage and accidents in Swedish and foreign nuclear power reactors in recent years. Furthermore, company has two other issues, which were implemented in the later stages of the work. Due to shrinkage and creep in the concrete and relaxation in the tendons, the prestressed capacity decreases with time which affects the structure negatively. The objective of this thesis is to investigate if there are methods for determining tensile forces where the tendons are not accessible. Methods are divided into two different types: one is cement grouting method, same as OKG and another one is oil-injection method. The final review of report is to investigate about TRAFIKVERKET methods to check/inspection the bridges. It can be concluded that the main expectations of this thesis has been fulfilled but some parts are still missing due to limitation of proper information. To contact with the various foreign nuclear power plants was not so easy within this short time. All our experiments were web-based and there were many confidential matters which is unreachable. Swedish Radiation Safety authority (SSM) helped us to get contact details of 3 different countries. The discussions about the reviews are summarized at the end of the report.
2

Inverkan av placering av spännkablar pågenomstansningskapacitet hos armeradebetongplattor / Influence of Post-Tensioned Reinforcement Distribution on Punching Shear Capacity of RC Slabs

Tran, David, Correa, Sebastian January 2018 (has links)
På grund av bostadsbristen de senaste åren har byggbranschen varit tvungen att möta den höga efterfrågan på bostäder. Ett sätt att underlätta det tryck som skapats på grund av den höga efterfrågan är att rekonstruera byggnader avsedda för annan användning än bostäder till bostadshus. Ett problem som har uppstått vid ombyggnation av till exempel ett kontorshus som består av spännarmerade pelardäck, är känsligheten för nya hål som krävs för nya installationer som går igenom de efterspända bjälklagen (bestående av betongplattor). Problematiken består av att håltagningar som vanligtvis är lokaliserade nära pelarna måste göras på ett större avstånd från pelaren på grund av de spännkablar som går över och nära plattans pelaranslutning. Efterspända kablar är normalt sett belägna över plattans pelaranslutning enligt dagens dimensioneringsnormer för att bidra till plattornas genomstansningskapacitet.I detta examensarbete undersöktes det om det finns vetenskapligt stöd för att flytta kablarna till en längre distans från pelaren (än vad normerna rekommenderar) med hänsyn till genomstansningskapaciteten, och därmed förenkla vid en potentiell ombyggnation.Huvudsyftet med arbetet var att med hjälp av en litteraturstudie samt beräkningar jämföra ett experiment som utförts av Ghassem Hassanzadeh och Håkan Sundquist vid KTH 1997- 1998 (som visade att kablar på ett längre avstånd från pelaren ger ett visst bidrag till betongplattans genomstansningskapacitet) med dagens normer samt nyare studier. Dagens dimensioneringsnormer inkluderar inte bidraget till kapaciteten när spännkablarna placeras utanför det så kallade grundkontrollsnittet (området som undersöks vid dimensionering enligt normerna).Ett annat syfte med detta examensarbete var att studera och uppdatera de beräknade resultaten (enligt dåtidens normer) från studien. Denna rapport uppdaterar studien genom att undersöka rådande normernas beräknade resultat samt jämföra med liknande tester från andra forskare. Dimensioneringsnormerna som undersöktes var Eurokod 2, ACI 318 och MC2010Som del av litteraturstudien redovisas även en liknande försökserie från Portugal av A. Pinho Ramos, Valter J.G. Lúcio & Duarte M.V Faria samt en sammanställning av olika försök som genomfördes i Schweiz av Clément T, Ramos A.P, Fernández Ruiz M, Muttoni A. Sammanställning i Schweiz beräknade genomstansningskapaciteten för 74 olika plattor där plattorna från försöket vid KTH finns med. Den här studien tyder på att dagens dimensioneringsnormer har en säkerhetsmarginal vid approximationer (vid både normalfall och vid flytt av kablar), men att det fortfarande saknas tillräckliga belägg för att rättfärdiga en flytt av spännkablar.Rapporten är skriven för CBI Betonginstitutet där G. Hassanzadeh har varit handledare.

Page generated in 0.3215 seconds