• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Evaluation of Convection Suppressor for Concentrating Solar Collectors with a Parabolic Trough / Utvärdering av konvektionsreducerare för koncentrerande solfångare med ett paraboliskt tråg

Nyberg, Fanny January 2018 (has links)
Absolicon Solar Collector AB in Härnösand, Sweden, develops concentrating solar collectors with a parabolic trough. In the solar collector trough, there is thermal loss due to convection. A convection suppressor was made and used as a method to reduce thermal loss due to convection in the trough. The objective of the project was to evaluate the convection suppressor for solar collectors with a parabolic trough and its impact on the performance (thermal loss characteristics) in two different orientations of the trough, horizontal and inclined. The performance of the solar collector was first measured without the convection suppressor; these results were compared to two previous quasi-dynamical tests of the solar collector performance made by two different institutes, Research Institute of Sweden and SPF Institut für Solartechnik (Switzerland). The comparison was made to validate the test results from the tests without the convection suppressor, which matched. Secondly, when the convection suppressor was made and tested in the two different orientations, the results of the performance with and without the convection suppressor was evaluated as well as the convection suppressor itself. The results showed a significant improvement of the solar collector performance in the aspect of reduced thermal loss when the convection suppressor was used, hence higher efficiency. / Absolicon Solar Collector AB I Härnösand, Sverige, utvecklar koncentrerande solfångare med ett paraboliskt tråg. I solfångarens tråg uppstår termiska förluster som en följd av konvektion. En konvektionsreducerare tillverkades och användes som metod för att minska de termiska förlusterna i tråget. Målet med projektet var att testa och utvärdera konvektionsreduceraren för koncentrerande solfångare med ett paraboliskt tråg samt dess inverkan på verkningsgraden i två olika positioner för tråget, horisontell och lutande. För att kunna mäta konvektionsreducerarens inverkan på solfångaren mättes först solfångarens prestanda utan konvektionsreduceraren i de två olika positionerna, detta resultat användes som referens efter validering. Valideringen gjordes genom att resultatet jämfördes sedan med två andra prestandamätningar (quasi-dynamical test) av solfångaren gjorda av två olika institut, Research Institute of Sweden och SPF Institut für Solartechnik (Schweiz). Därefter, när konvektionsreduceraren var tillverkat och testad i de olika positionerna på samma sätt som mätningarna utan konvektionsreducerare, jämfördes resultaten med och utan konvektionsreducerareet samt att en utvärdering gjordes av dess inverkan. Resultatet visade en signifikant förbättring av solfångarens prestanda i form av minskade termiska förluster när konvektionsreduceraren användes och därav ökad verkningsgrad.
2

Study case: The water-cooling effect on floating photovoltaic plants performance / Studiefall: Den vattenkylande effekten på flytande solcellsanläggningars prestanda

Dragon, Alice January 2024 (has links)
Floating solar technology is relatively new, and it comes with its own set of challenges and opportunities. This master thesis focuses on understanding how Floating Photovoltaic (FPV) projects perform compared to Ground-Based Photovoltaic (GPV) projects, in specific weather conditions. The following work is based on a case study: a floating power plant run by Akuo Energy, where sensors have been installed in order to measure the evolution of relevant physical and weather parameters on-site. Akuo Energy is a French independent renewable energy producer and developer founded in 2007. The company specializes in the development, financing, construction, and operation of renewable energy projects, including wind, solar and storage power plants. It is committed to producing clean, affordable, and reliable energy while promoting sustainable development and supporting local communities. The thesis is conducted within the Solar Technology Team, which centralizes the solar expertise of the company and implements innovative technologies to improve their Photovoltaic (PV) projects’ performances. As the number of FPV projects increases, the team raised the need for better evaluation of their performance compared to a standard GPV project, in terms of output power and energy yield. As it appears in the literature, FPV installations can differ from GPV, due to different operating conditions: power plant designs, module cooling, weather conditions, or degradation rates. These parameters need to be taken into account in the expected energy yield analysis, especially module cooling, since operating temperature has a proved impact on module efficiency. Today, technological and economic considerations on FPV specific design are therefore essential. However, the main solar projects development software PVsyst used at Akuo Energy does not include a default floating solar library. Experimental measurements are a good starting point for understanding how the numerical model needs to evolve to adapt to the FPV system. By examining a practical case and processing historical data, insights on FPV systems and how weather affects their efficiency can be provided. The objective of this thesis is then to better model the FPV array thermal losses due to the cooling effect and better estimate the yield for future Akuo Energy FPV projects during the development phase. / Flytande solteknik är relativt ny och kommer med sina egna utmaningar och möjligheter. Denna masteruppsats fokuserar på att förstå hur FPV-projekt presterar jämfört med GPV-projekt, under specifika väderförhållanden. Följande arbete är baserat på en fallstudie: ett flytande kraftverk som drivs av Akuo Energy, där sensorer har installerats för att mäta utvecklingen av relevanta fysiska parametrar och väderparametrar på plats. Akuo Energy är en fransk oberoende producent och utvecklare av förnybar energi som grundades 2007. Företaget är specialiserat på utveckling, finansiering, konstruktion och drift av projekt för förnybar energi, inklusive vind-, sol- och lagringskraftverk. Det är engagerat i att producera ren, prisvärd och pålitlig energi samtidigt som man främjar hållbar utveckling och stödjer lokala samhällen. Examensarbetet genomförs inom Solar Technology Team, som centraliserar företagets solexpertis och implementerar innovativa teknologier för att förbättraderas PV-projekts prestanda. När antalet FPV-projekt ökar, tog teamet upp behovet av bättre utvärdering av deras prestanda jämfört med ett standard GPV-projekt, vad gäller uteffekt och energiutbyte. Som det framgår av litteraturen kan FPV-installationer skilja sig från GPV på grund av olika driftsförhållanden: kraftverkskonstruktioner, modulkylning, väderförhållanden, eller nedbrytningshastigheter. Dessa parametrar måste beaktas ta hänsyn till den förväntade energiutbytesanalysen, särskilt modulkylning, eftersom driftstemperaturen har en bevisad inverkan på modulens effektivitet. Idag är därför tekniska och ekonomiska överväganden om FPV specifik design viktiga. Emellertid innehåller den huvudsakliga utvecklingsmjukvaran PVsyst för solenergiprojekt som används på Akuo Energy inte ett flytande solcellsbibliotek som standard. Experimentella mätningar är en bra utgångspunkt för att förstå hur den numeriska modellen behöver utvecklas för att anpassa sig till FPV-systemet. Genom att undersöka ett praktiskt fall och bearbeta historiska data kan insikter om FPV-system och hur vädret påverkar deras effektivitet ges. Syftet med denna avhandling är sedan att bättre modellera FPV-matrisens termiska förluster på grund av kyleffekten och bättre uppskatta avkastningen för framtida Akuo Energy FPV-projekt under utvecklingsfasen.

Page generated in 0.0466 seconds