1

Estudo da termografia por infravermelho: aplicações na engenharia e determinação de parâmetros termofísicos e geométricos de materiais.

Nunes Tavares da Silva, Renata January 2007 (has links)
Made available in DSpace on 2014-06-12T17:39:54Z (GMT). No. of bitstreams: 2 arquivo7543_1.pdf: 3966991 bytes, checksum: f5289dd0606adee8ac5d74b396510bd0 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / A termografia por infravermelho permite a realização de imagens térmicas da distribuição de temperatura superficial de objetos. Essas informações de temperatura podem ser usadas em análises qualitativas ou quantitativas. O objetivo principal deste trabalho é mostrar algumas áreas em que a aplicação da termografia é bem sucedida. São mostrados alguns exemplos onde as alterações na temperatura superficial de objetos podem ser usadas para a identificação de anomalias (seja em dispositivos, edificações, equipamentos ou no corpo humano). Esses exemplos incluem: a visualização de fenômenos térmicos básicos, a detecção de pontos quentes em instalações elétricas, um estudo preliminar sobre diagnóstico de doenças, a detecção de falhas em monumentos históricos e a detecção de perdas energéticas em equipamentos industriais. Também é resolvido, neste trabalho, um problema inverso de condução de calor a partir dos dados obtidos por termografia. O método divide-se em três partes: (a) experimental, que consiste no aquecimento em estufa de amostras em forma de placa de gesso e na gravação de imagens térmicas das placas durante o período de resfriamento; (b) simulação numérica, onde o modelo matemático das amostras é discretizado e o problema numérico é resolvido computacionalmente; (c) comparação entre resultados experimentais e numéricos. Para o caso apresentado é possível determinar tanto parâmetros termofísicos (condutividade térmica e capacidade térmica) do gesso quanto parâmetros termofísicos e geométricos (capacidade térmica, raio, altura, centro) de uma inclusão metálica. Foram obtidos resultados com boa precisão a partir de um experimento simples
2

Uso de termografia para avaliação da temperatura em cirurgias laser PRK

Vieira, Luiz Rosa January 2006 (has links)
Hipermetropia e miopia são problemas visuais freqüentes que decorrem de uma conformação inadequada da córnea. Esta inadequação pode ser corrigida com o emprego de métodos cirúrgicos através dos quais a curvatura dessa lente biológica é modificada. A possibilidade de dano na córnea, durante cirurgias refrativas, tem sido uma preocupação constante e um risco sempre presente, independentemente do método cirúrgico utilizado. Um limite de temperatura aceitável, dentro de uma margem de segurança prudente, tem sido buscado, existindo vários artigos sobre o assunto, não tendo sido encontrada, contudo, uma abordagem na forma aqui apresentada. O presente trabalho foi desenvolvido em duas etapas, sendo uma experimental preparatória, quando foram desenvolvidos estudos preliminares para projeto, montagem e teste dos acessórios necessários para pesquisa. Com o emprego destes acessórios foram feitas medições em olhos de suínos ex vivo, no sentido de determinar a emissividade da superfície da córnea usando termômetros de contato, forno corpo negro e termografia. Conhecidos os valores de emissividade da córnea, com e sem a camada epitelial, teve início a segunda etapa, também experimental, do trabalho. Inicialmente foram efetuadas medições, já com a participação de pacientes voluntários, para a elaboração de um protocolo para a análise das imagens infravermelhas, que seriam coletadas durante a realização de cirurgias laser. Estabelecido o protocolo, teve inicio o monitoramento da temperatura, através da gravação dinâmica de imagens, para posterior mapeamento dos campos de temperatura, de procedimentos cirúrgicos para correção de hipermetropia e miopia. Da análise das imagens gravadas, concluiu-se ser a termografia uma técnica eficaz para a medição dos campos de temperatura no olho humano, durante a realização de cirurgias empregando fontes laser e, ainda, que a temperatura final da superfície do globo ocular é baixa, não chegando aos 39 ºC em qualquer dos casos monitorados. Nestas cirurgias, foi empregada uma metodologia, desenvolvida pelo cirurgião, para controle da temperatura, que consistiu no uso de colírio anestésico refrigerado, na fase pré-operatória e após a aplicação do laser, seguido da instalação de lente gelatinosa, também refrigerada e aplicação de mais colírio anestésico refrigerado. / Hypermetropia and myopia are frequent visual problems that happen due to an inadequate cornea conformation. This inadequacy may be amended by means of surgical procedures that modify the curvature of this biological lens. The possibility of damage on the cornea during refractive surgery has been a constant concern and an ever-present hazard, independently of the surgical method used. A limit of acceptable temperature, within a prudent safety margin, has been pursued and there are various papers about the subject; however, with an approach different from the one that is introduced here. The present research was developed in two parts: an experimental preparatory one, in which preliminary studies for the project, assemblage and test of the necessary accessories for the research were performed. With the use of these accessories, measurements of swine eyes ex vivo were made in order to determine the emissivity of the cornea ocular region, by using contact thermometers, black body furnace, and thermography. After the cornea emissivity values were found, with and without the epithelial stratum, the second phase of the research, which was also experimental, began. It comprised the measurement of self-conscious volunteers to establish a protocol for the analysis of the infrared images, which would be collected during laser surgeries. After this protocol was established, the monitoring of the temperature was proceeded, through the dynamic recording of images, for mapping the temperature fields throughout surgical procedures to the improvement of myopia and hypermetropia. From the analysis of the images recorded, it was concluded that thermography is an effective instrument for field temperature measuring of the human eye during surgeries involving laser sources. It was also found that the temperature on the eye surface, after the surgery, was below 39 ºC in any of the cases studied. In these surgeries, a methodology developed by surgeon, for the control of the temperature, which consisted in the use of chilled collyrium at the presurgical phase and after the laser application, followed by the implantation of gelatinous lenses, also chilled and the instillation of more chilled collyrium.
3

Uso de termografia para avaliação da temperatura em cirurgias laser PRK

Vieira, Luiz Rosa January 2006 (has links)
Hipermetropia e miopia são problemas visuais freqüentes que decorrem de uma conformação inadequada da córnea. Esta inadequação pode ser corrigida com o emprego de métodos cirúrgicos através dos quais a curvatura dessa lente biológica é modificada. A possibilidade de dano na córnea, durante cirurgias refrativas, tem sido uma preocupação constante e um risco sempre presente, independentemente do método cirúrgico utilizado. Um limite de temperatura aceitável, dentro de uma margem de segurança prudente, tem sido buscado, existindo vários artigos sobre o assunto, não tendo sido encontrada, contudo, uma abordagem na forma aqui apresentada. O presente trabalho foi desenvolvido em duas etapas, sendo uma experimental preparatória, quando foram desenvolvidos estudos preliminares para projeto, montagem e teste dos acessórios necessários para pesquisa. Com o emprego destes acessórios foram feitas medições em olhos de suínos ex vivo, no sentido de determinar a emissividade da superfície da córnea usando termômetros de contato, forno corpo negro e termografia. Conhecidos os valores de emissividade da córnea, com e sem a camada epitelial, teve início a segunda etapa, também experimental, do trabalho. Inicialmente foram efetuadas medições, já com a participação de pacientes voluntários, para a elaboração de um protocolo para a análise das imagens infravermelhas, que seriam coletadas durante a realização de cirurgias laser. Estabelecido o protocolo, teve inicio o monitoramento da temperatura, através da gravação dinâmica de imagens, para posterior mapeamento dos campos de temperatura, de procedimentos cirúrgicos para correção de hipermetropia e miopia. Da análise das imagens gravadas, concluiu-se ser a termografia uma técnica eficaz para a medição dos campos de temperatura no olho humano, durante a realização de cirurgias empregando fontes laser e, ainda, que a temperatura final da superfície do globo ocular é baixa, não chegando aos 39 ºC em qualquer dos casos monitorados. Nestas cirurgias, foi empregada uma metodologia, desenvolvida pelo cirurgião, para controle da temperatura, que consistiu no uso de colírio anestésico refrigerado, na fase pré-operatória e após a aplicação do laser, seguido da instalação de lente gelatinosa, também refrigerada e aplicação de mais colírio anestésico refrigerado. / Hypermetropia and myopia are frequent visual problems that happen due to an inadequate cornea conformation. This inadequacy may be amended by means of surgical procedures that modify the curvature of this biological lens. The possibility of damage on the cornea during refractive surgery has been a constant concern and an ever-present hazard, independently of the surgical method used. A limit of acceptable temperature, within a prudent safety margin, has been pursued and there are various papers about the subject; however, with an approach different from the one that is introduced here. The present research was developed in two parts: an experimental preparatory one, in which preliminary studies for the project, assemblage and test of the necessary accessories for the research were performed. With the use of these accessories, measurements of swine eyes ex vivo were made in order to determine the emissivity of the cornea ocular region, by using contact thermometers, black body furnace, and thermography. After the cornea emissivity values were found, with and without the epithelial stratum, the second phase of the research, which was also experimental, began. It comprised the measurement of self-conscious volunteers to establish a protocol for the analysis of the infrared images, which would be collected during laser surgeries. After this protocol was established, the monitoring of the temperature was proceeded, through the dynamic recording of images, for mapping the temperature fields throughout surgical procedures to the improvement of myopia and hypermetropia. From the analysis of the images recorded, it was concluded that thermography is an effective instrument for field temperature measuring of the human eye during surgeries involving laser sources. It was also found that the temperature on the eye surface, after the surgery, was below 39 ºC in any of the cases studied. In these surgeries, a methodology developed by surgeon, for the control of the temperature, which consisted in the use of chilled collyrium at the presurgical phase and after the laser application, followed by the implantation of gelatinous lenses, also chilled and the instillation of more chilled collyrium.
4

Uso de termografia para avaliação da temperatura em cirurgias laser PRK

Vieira, Luiz Rosa January 2006 (has links)
Hipermetropia e miopia são problemas visuais freqüentes que decorrem de uma conformação inadequada da córnea. Esta inadequação pode ser corrigida com o emprego de métodos cirúrgicos através dos quais a curvatura dessa lente biológica é modificada. A possibilidade de dano na córnea, durante cirurgias refrativas, tem sido uma preocupação constante e um risco sempre presente, independentemente do método cirúrgico utilizado. Um limite de temperatura aceitável, dentro de uma margem de segurança prudente, tem sido buscado, existindo vários artigos sobre o assunto, não tendo sido encontrada, contudo, uma abordagem na forma aqui apresentada. O presente trabalho foi desenvolvido em duas etapas, sendo uma experimental preparatória, quando foram desenvolvidos estudos preliminares para projeto, montagem e teste dos acessórios necessários para pesquisa. Com o emprego destes acessórios foram feitas medições em olhos de suínos ex vivo, no sentido de determinar a emissividade da superfície da córnea usando termômetros de contato, forno corpo negro e termografia. Conhecidos os valores de emissividade da córnea, com e sem a camada epitelial, teve início a segunda etapa, também experimental, do trabalho. Inicialmente foram efetuadas medições, já com a participação de pacientes voluntários, para a elaboração de um protocolo para a análise das imagens infravermelhas, que seriam coletadas durante a realização de cirurgias laser. Estabelecido o protocolo, teve inicio o monitoramento da temperatura, através da gravação dinâmica de imagens, para posterior mapeamento dos campos de temperatura, de procedimentos cirúrgicos para correção de hipermetropia e miopia. Da análise das imagens gravadas, concluiu-se ser a termografia uma técnica eficaz para a medição dos campos de temperatura no olho humano, durante a realização de cirurgias empregando fontes laser e, ainda, que a temperatura final da superfície do globo ocular é baixa, não chegando aos 39 ºC em qualquer dos casos monitorados. Nestas cirurgias, foi empregada uma metodologia, desenvolvida pelo cirurgião, para controle da temperatura, que consistiu no uso de colírio anestésico refrigerado, na fase pré-operatória e após a aplicação do laser, seguido da instalação de lente gelatinosa, também refrigerada e aplicação de mais colírio anestésico refrigerado. / Hypermetropia and myopia are frequent visual problems that happen due to an inadequate cornea conformation. This inadequacy may be amended by means of surgical procedures that modify the curvature of this biological lens. The possibility of damage on the cornea during refractive surgery has been a constant concern and an ever-present hazard, independently of the surgical method used. A limit of acceptable temperature, within a prudent safety margin, has been pursued and there are various papers about the subject; however, with an approach different from the one that is introduced here. The present research was developed in two parts: an experimental preparatory one, in which preliminary studies for the project, assemblage and test of the necessary accessories for the research were performed. With the use of these accessories, measurements of swine eyes ex vivo were made in order to determine the emissivity of the cornea ocular region, by using contact thermometers, black body furnace, and thermography. After the cornea emissivity values were found, with and without the epithelial stratum, the second phase of the research, which was also experimental, began. It comprised the measurement of self-conscious volunteers to establish a protocol for the analysis of the infrared images, which would be collected during laser surgeries. After this protocol was established, the monitoring of the temperature was proceeded, through the dynamic recording of images, for mapping the temperature fields throughout surgical procedures to the improvement of myopia and hypermetropia. From the analysis of the images recorded, it was concluded that thermography is an effective instrument for field temperature measuring of the human eye during surgeries involving laser sources. It was also found that the temperature on the eye surface, after the surgery, was below 39 ºC in any of the cases studied. In these surgeries, a methodology developed by surgeon, for the control of the temperature, which consisted in the use of chilled collyrium at the presurgical phase and after the laser application, followed by the implantation of gelatinous lenses, also chilled and the instillation of more chilled collyrium.
5

Análise de sistemas de energia e máquinas eléctricas com recurso a termografia

Gonçalves, Tiago Miguel Alves January 2011 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores. Universidade do Porto. Faculdade de Engenharia (Automação). 2011
6

Detecção de defeitos em materiais cerâmicos usando termografia

Rodríguez, Fernando de Jésus López 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Engenharia Mecânica, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T05:28:41Z (GMT). No. of bitstreams: 1 279414.pdf: 17045019 bytes, checksum: 88b3badc24facdedabb37312bffaedb2 (MD5) / Atualmente existem dois metodos de inspeçao termografica: termografia passiva e termografia ativa. Enquanto na termografia ativa, uma estimulaçao externa é usada para provocar um fuxo de calor interno no objeto, na termografia passiva nenhuma estimulaçao é usada. No presente trabalho, investiga-se a aplicaçao da termografia ativa para detectar e caracterizar defeitos internos em materiais ceramicos. Para tal proposito, é analisado o comportamento térmico do material ao ser exposto a diferentes regimes de resfriamento. Uma formulaçao numerica é proposta para simular o processo térmico, consistindo na soluçao da equaçao da energia em regime transiente e 3D, usando volumes finitos, permitindo desta forma o estudo do fenomeno de difusao interna de calor e as transferencias por conveccao e radiaçao com o ambiente externo. As simulaçoes foram realizadas variando diferentes parametros, tais como a profundidade e diametro dos defeitos, localizaçao e propriedades termofisicas. Os mapas termicos das superficies em questao foram comparados com mediçoes feitas em laboratorio utilizando uma camara infravermelha. As mediçoes foram realizadas em tijolos ceramicos maciços. Parametros de detecçao como o Contraste Termico Absoluto e o Contraste Termico Standard foram utilizados. Este ultimo mostrou melhor nivel de detecçao, decorrente da eliminaçao das interferencias do ambiente externo.
7

Análise termográfica em dois modos ventilatórios e efeitos adversos agudos em voluntários sadios após uso de ventilação não invasiva / Thermographic analysis in two ventilation modes and acute adverse effects in healthy volunteers after the use of noninvasive ventilation

Pontes, Suzy Maria Montenegro 30 August 2016 (has links)
PONTES, S. M. M. Análise termográfica em dois modos ventilatórios e efeitos adversos agudos em voluntários sadios após uso de ventilação não invasiva. 2016. 96 f. Dissertação (Mestrado em Ciências Médicas) - Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-09-28T16:05:06Z No. of bitstreams: 1 2016_dis_smmpontes.pdf: 2758225 bytes, checksum: 2b72398276ca11c05742c87a088b8b82 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-09-28T16:05:18Z (GMT) No. of bitstreams: 1 2016_dis_smmpontes.pdf: 2758225 bytes, checksum: 2b72398276ca11c05742c87a088b8b82 (MD5) / Made available in DSpace on 2016-09-28T16:05:18Z (GMT). No. of bitstreams: 1 2016_dis_smmpontes.pdf: 2758225 bytes, checksum: 2b72398276ca11c05742c87a088b8b82 (MD5) Previous issue date: 2016-08-30 / Mechanical Ventilation (MV) replaces all or part of spontaneous ventilation, as it enables improved gas exchange and decreased work of breathing, which can be used non-invasively through an external interface. The success of the Non-Invasive Ventilation (NIV) is dependent on the comfort and acceptance of the mask by the patient. However, the use of masks is associated with adverse acute effects and discomfort. The hypotheses of this study are: variables related to NIV have repercussions on the local microcirculation of the skin in the contact zones with the mask, changing the temperature levels of skin tissue on the face in the contact zones with the oronasal mask. These possible temperature changes in the contact areas are amenable to measurement by infrared thermography and can relate to the acute adverse effects. Objectives: To compare the incidence and intensity of acute adverse effects, and the variation in skin temperature of the ventilation modes of NIV: CPAP versus double level pressure and analyze the relationship between the acute adverse effects of the application of NIV by oronasal mask and temperature variations of the skin face into two regions: the contact zones of the mask and, in particular, the nasal dorsum. Methods: 20 healthy volunteers, both genders that after dermatologic evaluation were submitted to NIV with mask oronasal for an hour, randomly assigned to groups according to the ventilation mode CPAP (continuous positive airway pressure) or double level pressure (two pressure levels, the highest in the inspiration). The infrared thermography image was performed in two distinct regions in the face region and at different times. Participants answered a questionnaire about the adverse effects noted during the NIV. Results: The incidence and intensity of acute adverse effects were higher in double level pressure ventilation mode in relation to CPAP (16.1% versus 5.6%, p=0.001). Thermographic analysis has evidenced a cooling in the contact area with the skin of the face (p<0.05) and nasal dorsum (p<0.05) immediately after the withdrawal of NIV. Acute adverse effects at higher intensity occurred predominantly in the group of participants where the reduction in the average temperature was lower (14.4% versus 7.2%, p=0.04) in the nasal dorsum. The thermographic visual analysis of cooling and heating areas in the face identified areas of hypoperfusion or reactive hyperemia. Conclusions: Acute adverse effects of the use of NIV showed a higher incidence and intensity in the double level pressure ventilation mode. Regarding the average temperature variation there was no statistically significant difference between the ventilation modes. It showed a significant cooling of the skin in the contact area of the mask and the nasal dorsum immediately after the withdrawal of the interface, probably due to the reduction of local perfusion. It was noted the phenomenon of reactive hyperemia in the subsequent moments in the mask contact area, but in the nasal dorsum, the cooling of the region has remained. There was an association between acute adverse effects of the application of NIV by oronasal mask to a lower cooling or increased reactive hyperemia in the nasal dorsum region after the withdrawal of the interface. / A Ventilação Mecânica (VM) substitui total ou parcialmente a ventilação espontânea, propiciando melhora das trocas gasosas e diminuição do trabalho respiratório, podendo ser utilizada de forma não invasiva por meio de uma interface externa. O sucesso da Ventilação Não Invasiva (VNI) é dependente do conforto e da aceitação da máscara pelo paciente. Entretanto, o uso de máscaras está associado a efeitos adversos agudos e desconforto. As hipóteses deste trabalho são: variáveis relacionadas à VNI como o modo ventilatório e ajustes pressóricos repercutem na microcirculação local da pele nas zonas de contato com a máscara, alterando os níveis de temperatura do tecido cutâneo na face nas zonas de contato com a máscara oronasal. Estas possíveis mudanças de temperatura nas áreas de contato são passíveis de mensuração por termografia infravermelha e podem se relacionar aos efeitos adversos agudos. Objetivos: Comparar a incidência e a intensidade de efeitos adversos agudos e a variação da temperatura cutânea dos modos ventilatórios da VNI: (continuous positive airway pressure) CPAP versus Duplo-nível pressórico (dois níveis pressóricos, o maior na inspiração) e analisar a relação entre os efeitos adversos agudos da aplicação de VNI por máscara oronasal e variações de temperatura da pele da face em duas regiões: nas zonas de contato da máscara e, em especial, no dorso do nariz. Métodos: 20 voluntários sadios ambos os gêneros após avaliação dermatológica foram submetidos à VNI com máscara oronasal por uma hora, alocados aleatoriamente em grupos de acordo com o modo ventilatório CPAP ou Duplo-nível pressórico. A termografia por imagem infravermelha foi realizada em duas regiões distintas (dorso do nariz e contato da máscara) da face e em momentos diferentes. Os participantes responderam a um questionário sobre os efeitos adversos notados durante a VNI. Resultados: A incidência e a intensidade dos efeitos adversos agudos foram maiores no modo ventilatório Duplonível pressórico em relação ao CPAP (16,1% versus 5,6%, p=0,001). A análise termográfica evidenciou um esfriamento na região de contato da máscara com a pele da face (p<0,05) e no dorso do nariz (p<0,05) imediatamente após a retirada da VNI. Os efeitos adversos agudos em maior intensidade ocorreram predominantemente no grupo de participantes onde foi menor a redução da temperatura média (14,4% versus 7,2%, p=0,04) no dorso do nariz. A análise visual termográfica de zonas de esfriamento e aquecimento na face identificou regiões de hipoperfusão ou hiperemia reativa após a aplicação da VNI. Conclusões: O uso do modo Duplo-nível pressórico associou-se a maior incidência e intensidade de efeitos adversos agudos associados à VNI. Houve associação entre efeitos adversos agudos e menor esfriamento da pele do dorso do nariz imediatamente após a retirada da máscara. A termografia cutânea pode ser uma ferramenta adicional na detecção de efeitos adversos na pele da face associados ao uso da VNI.
8

Detecção e caracterização de defeitos internos por termografia infravermelha pulsada

Rodríguez, Fernando de Jésus López January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:55:06Z (GMT). No. of bitstreams: 1 328997.pdf: 12083628 bytes, checksum: d77530944b0286906102e770e698109e (MD5) Previous issue date: 2014 / A termografia pulsada (TP) é uma técnica promissora para a avaliação não-destrutiva de materiais. O protocolo de inspeção consiste na aplicação de um pulso térmico no espécime e monitorar a resposta térmica da superfície via radiação infravermelha (IV). Descontinuidades internas aparecem na sequência térmica como "hot spots" ou padrões térmicos irregulares, os quais são prodruzidos por alterações na taxa interna de difusão de calor. Apesar de ser uma das técnicas mais usadas e atrativas para a avaliação não-destrutiva, sua aplicação apresenta grandes desafios especialmente durante a inspeção de materiais anisotrópicos. 'Blurring', a perda de visibilidade devido aos efeitos da condução lateral de calor e a não-uniformidade produzida durante a excitação térmica representam as maiores limitações da TP. Esta tese é focada na otimização da inspeção por TP em laminados compósitos. Para tal propósito, foi desenvolvido um modelo termo-numérico para a análise da resposta térmica da material devido a presença de defeitos internos. Um estudo paramétrico foi desenvolvido com o objetivo de estudar o impacto do aquecimento não-uniforme, da intensidade da radiação e da geometria dos defeitos em vários parâmetros informativos da inspeção por TP. Uma análise das três técnicas mais usadas para o tratamento de sinais termográficos foi realizada e os seus desempenhos foram avaliados em função da relação sinal-ruído no ponto de maior contraste entre região com defeito e região sem defeito. Neste trabalho foi desenvolvida uma nova técnica de processamento e análise de imagens térmicas. A nova técnica - baseada no método de regressão dos mínimos quadrados parciais (PLSR) - decompõe a sequência térmica em variáveis latentes, permitindo assim a separação das diversas fontes de ruído que afetam a qualidade das imagens. A partir deste método de correlação foi desenvolvido um modelo empírico para a quantificação da profundidade e tamanho lateral dos defeitos empregando dados experimentais. Ambos os métodos - de tratamento de sinais e quantificação de defeitos - foram analisados e comparados com técnicas tradicionais, apresentando uma melhoria substancial na relação sinal-ruído e na precisão no processo de inversão de profundidade e forma dos defeitos.<br> / Abstract: Pulsed thermography (PT) is a novel and promissory technique for the nondestructive and evaluation (NDT&E) of materials. The inspection protocol consists in pulse heating the specimen while monitoring the resulting thermal response via infrared (IR) radiation. Subsurface discontinuities appear as transient hot spots or irregular thermal patterns in the thermogram sequence, which are produced by the alterations in the internal heat diffusion fluxes. In spite of being one of the most used and attractive methods for the NDT&E, its application still presents challenges specially when inspecting anisotropic materials. 'Blurring', the lost of defect visibility due to the effects of lateral heat conduction and the non-uniform heating produced during the application of the thermal excitation, represent the major drawbacks of PT. This thesis is focused on the optimization of the PT inspection of laminated composites. A thermal-numerical model is developed in order to analysis the thermal response of the material due to the presence of subsurface defects. A parametric study was performed aiming to study the impact of the effects of non-uniform heating, irradiation density and defects geometry on several informative variables of the PT inspection. An in-depth analysis of three of the most used PT sinal processing techniques was carried out and their performance was evaluated in terms of the signal-to-noise (SNR) at maximum signal contrast. In this work was also developed a new promissory technique for the processing and analysis of thermographic data. The new method - based on partial least squares regression (PLSR) - decomposes the thermal sequence into latent variables, allowing to separate several sources of noise affecting the quality of the images. From the statistical correlation method an empirical model was developed for the quantification of the depth and lateral size of defects using experimental data. Both methods - for the signal processing and for the inversion of depth and lateral size - were analyzed and compared with traditional techniques, achieving a substantial improvement in the signal-to-noise ratio and in the accuracy in the prediction results of depth and lateral size of the defects.
9

Estudo dos aspectos da termografia digital infravermelha, da PAAF (citológico e imunocitologico), e dos achados histológicose imunohistoquimicos da endometriose subcutânea na mulher / Study of aspects of infrared thermography digital, FNA (cytological and immunocytological), and immunohistochemical findings histológicose subcutaneous endometriosis in women

Oliveira Filho, Manoel January 2013 (has links)
OLIVEIRA FILHO, Manoel. Estudo dos aspectos da termografia digital infravermelha, da PAAF (citológico e imunocitologico), e dos achados histológicose imunohistoquimicos da endometriose subcutânea na mulher. 2013. 100 f. Tese (Doutorado em Ciências Médicas) – Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2013. / Submitted by denise santos (denise.santos@ufc.br) on 2015-05-26T16:26:39Z No. of bitstreams: 1 2013_tese_moliveirafilho.pdf: 4848592 bytes, checksum: cd067e10267591c4e6f29f9ed1cd559f (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2015-05-26T16:30:38Z (GMT) No. of bitstreams: 1 2013_tese_moliveirafilho.pdf: 4848592 bytes, checksum: cd067e10267591c4e6f29f9ed1cd559f (MD5) / Made available in DSpace on 2015-05-26T16:30:39Z (GMT). No. of bitstreams: 1 2013_tese_moliveirafilho.pdf: 4848592 bytes, checksum: cd067e10267591c4e6f29f9ed1cd559f (MD5) Previous issue date: 2013 / Endometriosis is defined as the presence of endometrial glands and stroma in an anatomical site other than the uterine cavity and muscles, which may be pelvic or extra - pelvic, affecting up to 5 - 1 5% of women of childbearing age, in its various presentations. Extra pelvic endometriosis affects 12% of women with endometriosis, a condition that is rare umbilical endometriosis - about 0.5% of all patients with ectopic endometrium. Most cases of subcuta neous endometriosis develop from pelvic organs to surgery scars in young women in the reproductive age. The complaints are tumor growth in the abdominal wall after interventional procedures and pain. It must be differentiated from incisional hernias, granu lomas, abscesses and benign and malignant tumors. The methods are based on clinical diagnosis and in fine needle aspiration (FNA) cytology. The excision and histopathological analysis, the ultrasound, the computed tomography and magnetic resonance imaging and in our research, teletermography use (not reported in the literature). The morphological characteristics allow the cytological diagnosis from fine needle aspiration (FNA). However, to date, the immunohistochemical profile and biological characteristics of this unusual type of endometriosis is poorly understood, requiring cellular phenotyping studies for understanding the pathophysiology and its possible treatments. Objectives : We formed a study group (20 cases) from the smears of fine needle aspiration and its analysis by immunocytochemistry, assessing the teletermography digital and histopathological lesions. In seven cases (07) were performed immunohistochemistry for estrogen receptors, progesterone and marker of cell proliferation (Ki - 67). The morphol ogical aspects will be faced with the possibility or not of the markers. To store data, will be created spreadsheet Excel/Office 2000. The database will be exported to the Soft Prism 5.0, which will be the logical consistency of the final typed information . Statistical significance will be performed by Fisher's exact test with a confidence interval of 95%. Results. Twenty patients with a mean age of 30.4±1.3 years were evaluated during the period January 2007 to December 2010. The location was more frequent in surgical scar resulting from cesarean section (n=18), in the suprapubic region level of the umbilicus (laparoscopy) (n=1), resulting in surgical scar of hysterectomy (n=1). Thirteen were primiparous, four secundiparous, two nulliparous and one tercípar ous. During this period, 6818 deliveries were performed by cesarean. The incidence of endometriosis in the scar was 0.26%, the time interval between surgery and onset of symptoms ranged from 6 to 36 months with a mean of 17±1.6. The most common complaint w as pain in the scar (80%) of these 40% reported pain cyclical. Lump in the scar was found in 17 patients (85%), fixed and painful. In two cases presented hematometra or hematoma. Eleven patients (55%) reported increased nodule during the pre and menstrual. FNA showed endometrial cells and stromal cells in the cytologig smears (65%), the digital telethermography was performed in all. The thermographic asymmetry indicates inflammation. All cases were treated with surgical resection. No clinical treatment was done before and after surgery. All patients were followed for a period exceeding two years and recurrence of 3 in 20 patients (15%). In two patients, the recurrence was after 12 months, the third was to 24 months, both with a history of peritoneal endometr iosis. The results of immunohistochemical showed epithelium and stroma receptor s in 80% and 100% and 72% Ki - 67 / A endometriose é definida como a presença de estroma e glândulas endometriais em um sítio anatômico diferente da cavidade uterina e musculatura, podendo ser pélvica ou extrapélvica, chegando a acometer, nas diversas apresentações, de 5 a 15% das mulheres em idade fértil. A endometriose extrapélvica acomete 12% das mulheres com endometriose, sendo rara a condição de endometriose umbilical – cerca de 0,5% de todas as pacientes com ectopia endometrial. A maioria dos casos de endometriose subcutânea desenvolve-se com origem em cicatrizes cirúrgicas pélvicas em mulheres jovens no período reprodutivo, que apresentam crescimento tumoral na parede abdominal, após procedimentos intervencionistas. Faz-se diagnóstico diferencial com hérnias incisionais, granulomas de corpo estranho, abscesso e neoplasias. Os métodos diagnósticos são baseados na clínica, na punção aspirativa com agulha fina (PAAF) e do seu estudo citológico, na exérese da lesão e da análise histopatológica, na ultrassonografia, na tomografia computadorizada, na ressonância magnética, e neste experimento, o uso da Teletermografia. As características morfológicas permitem o diagnóstico citopatológico com base na punção aspirativa com agulha fina (PAAF). Até o momento, no entanto, o perfil imuno-histoquímico e as características biológicas desse tipo incomum de endometriose estão mal entendidos, necessitando de estudos de fenotipagem celular para a compreensão da fisiopatologia e de seus eventuais tratamentos. Objetivo. Foi constituído um grupo de estudo (20 casos) com suporte nos esfregaços de punção aspirativa com agulha fina (PAAF) e da sua analise pela imunocitoquimica, pela avaliação da Teletermografia digital e do estudo histopatológico das lesões. Em sete casos (07), foram realizados imunohistoquímica para receptores de estrogênio, progesterona e marcador de proliferação celular (KI-67). Os aspectos morfológicos serão confrontados com a positividade ou não dos marcadores. Para armazenar dados, será criada planilha de Excel/Office 2000. O banco de dados será exportado para o Soft Prism 5.0, onde será feita a consistência lógica final das informações digitadas. A significância estatística será realizada pelo Teste Exato, de Fisher, com intervalo de confiança de 95%. Resultados. 20 pacientes com média de idade de 30,4±1,3 anos foram avaliados. A localização mais frequente foi em cicatriz cirúrgica decorrente de parto abdominal (n=18), na região suprapúbica em nível da cicatriz umbilical (videolaparoscopia) (n=1), em cicatriz cirúrgica decorrente de histerectomia (n=1). Treze eram primíparas, quatro secundíparas, duas tercíparas e uma nulípara. Nesse período, foram realizados 6.818 partos por via abdominal. A incidência de endometriose na cicatriz foi de 0,26%. O intervalo de tempo da cirurgia ao surgimento dos sintomas variou de seis a 36 meses com media de 17±1,6. A queixa mais comum foi dor na cicatriz 80%; destas, 40% referiam dor cíclica. Nódulo na cicatriz foi encontrado em 17 pacientes (85%), fixo e doloroso. Em dois casos apresentaram hematometra ou hematoma. Onze pacientes (55%) descreveram aumento do nódulo durante o período pré e menstrual. A PAAF mostrou células endometriais e estromais em 13 citologias 65%; e a Teletermografia digital foi realizada em todas. A assimetria termográfica indica processo inflamatório. Todos os casos foram tratados com ressecção cirúrgica. Não foi realizado nenhum tratamento clinico pré e pós-cirúrgico. Todas as pacientes foram acompanhadas por um período superior a dois anos e houve recidiva em 3/20 (15%). Em duas a recidiva foi aos 12 meses, a terceira foi aos 24 meses, ambas com antecedentes de endometriose peritoneal. Os resultados imuno histoquímicos mostraram receptores de E no epitélio e no estroma em 80%; os de P foram 100% e o Ki-67 72%
10

Aplicação da termografia infra vermelha para identificação de danos na aderência entre concreto e polímero reforçado com fibras

Caldeira, Mariana Martino January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:37:29Z (GMT). No. of bitstreams: 1 340772.pdf: 5583241 bytes, checksum: 91cbe5d4a35a4fd76274a008016890d0 (MD5) Previous issue date: 2016 / Em estruturas de concreto reforçadas com Polímeros Reforçados com Fibras (PRF), a aderência entre o PRF e o concreto deve ser analisada, uma vez que falhas nessa interface podem promover enfraquecimento do reforço. Por meio da técnica não destrutiva de termografia infravermelha é possível detectar e avaliar tais falhas. A proposta desta pesquisa é utilizar a termografia infravermelha ativa e passiva para analisar danos subsuperficiais na interface PRF/concreto. Aplicando-se a termografia infravermelha ativa, são pesquisados: diferentes equipamentos para excitação térmica e quais as influências disso na identificação do dano nas imagens infravermelhas. A partir da escolha de um tipo de excitação térmica, faz-se a análise do cálculo de contraste térmico para avaliar a delaminação em vigas reforçadas por PRF. Para a termografia infravermelha passiva, foram realizadas análises quantitativas para avaliação de danos entre concreto e PRF. Uma delas apresenta uma técnica para dimensionamento da extensão do dano e a outra compara, por métodos estatísticos, a temperatura no defeito quando variados o tempo de exposição solar, tipo de reforço, dimensão e tipo de dano e ainda diferentes matrizes de colagem. Os resultados das análises qualitativas mostram que a termografia infravermelha promove notável identificação de falhas subsuperficiais entre concreto e PRF. As análises quantitativas também foram bem sucedidas. A técnica para dimensionamento do dano teve erro abaixo de 15%. A utilização de análise estatística mostrou que o tempo de exposição solar é o elemento que mais influência na temperatura do defeito. Em relação a avaliação da câmera infravermelha, observou-se que a inserção correta da emissividade é de caráter essencial para se obterem imagens infravermelhas confiáveis.<br> / Abstract: Concrete structures strengthened with Fiber Reinforced Polymer (FPR) need inspection at FPR/concrete interface, once damages at this interface can promote the weakening of strengthening system. The infrared thermography is a non-destructive technique that may detect and assess such damages. The purpose of this research is to use active and passive infrared thermography to analyze subsurface damages at FRP/concrete interface. Different sources of heating were used in order to produce thermal excitation and its influence in identifying damages on infrared images analyzed, when applied active infrared thermography. Afterwards, choosing one type of heating and calculating the thermal contrast of images, was investigated the delamination in beams strengthened with FRP by calculating the thermal contrast. Quantitative analyses were performed to assess damage between concrete and FRP by using passive infrared thermography. One of them presents a technique for quantifying the damages and the other compares defects? temperatures when the time of sun exposure, type of strengthening, size and type of damages and still different matrices of bonding are varied. The results of qualitative analysis show that, in general, subsurface damages between concrete and FRP are remarkable identified by infrared thermography. Quantitative analyses were also successful. The error of the technique to quantify the damages was below 15%. Statistical analysis shows that the time of exposure to sunlight is the factor that most influences the defect temperature. Regarding the evaluation of the infrared camera, the correct insertion of the emissivity was essential to obtain reliable infrared images.