• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 5
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 114
  • 92
  • 67
  • 36
  • 35
  • 26
  • 22
  • 22
  • 20
  • 19
  • 19
  • 18
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Caracterizacao dosimetrica das fontes de braquiterapia - na forma de fios de iridio-192 de baixa taxa de dose, produzidos pelo Laboratorio de Fontes de Braquiterapia CTRS/IPEN/CNEN-SP

SILVA, MARCO A. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:43Z (GMT). No. of bitstreams: 1 09608.pdf: 4456870 bytes, checksum: 7029deaa1ca99f712b8a29825c470ebd (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
62

Estudo comparativo entre metodos de calibracao de aplicadores clinicos de radiacao beta / Comparative study among calibration methods of clinical applicators of beta radiation

ANTONIO, PATRICIA de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 0 / Os aplicadores clínicos de 90Sr+90Y são instrumentos utilizados em procedimentos de braquiterapia e devem ser calibrados periodicamente, de acordo com normas e recomendações internacionais. Neste trabalho, foram estudados quatro métodos de calibração de aplicadores dermatológicos e oftálmicos, comparando-se os resultados com os fornecidos pelos certificados de calibração dos fabricantes dos aplicadores. Os métodos envolveram o aplicador clínico padrão do Laboratório de Calibração de Instrumentos (LCI), calibrado pelo laboratório padrão primário americano do National Institute of Standards and Technology, como referência; um aplicador da Amersham, também pertencente ao LCI, como referência; uma mini-câmara de extrapolação desenvolvida no IPEN como padrão absoluto; e dosimetria termoluminescente. A mini-câmara de extrapolação e uma câmara de extrapolação comercial PTW foram estudadas com relação ao seu desempenho por meio de testes de controle de qualidade, como corrente de fuga, repetitividade e reprodutibilidade. A distribuição de dose em profundidade na água, estudo de grande importância na dosimetria de aplicadores clínicos, foi determinada utilizando-se a mini-câmara de extrapolação e dosímetros termoluminescentes. Os resultados obtidos foram considerados satisfatórios para os dois casos, quando comparados com os dados fornecidos pela norma IAEA (2002). Além disso, foi desenvolvido um sistema postal dosimétrico para a calibração de aplicadores clínicos por meio da técnica da termoluminescência, para ser enviado para clínicas e hospitais, sem a necessidade do transporte das fontes ao LCI do IPEN para calibração. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
63

Caracterização do campo de nêutrons na instalação para estudo e, BNCT no reator IEA-R1 / Neutron field characterization in the installation for BNCT study in the IEA-R1 reactor

CARNEIRO JUNIOR, VALDECI 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:52Z (GMT). No. of bitstreams: 0 / Este trabalho tem como objetivo realizar a caracterização do campo de nêutrons e radiação gama na posição de irradiação de amostras em uma instalação para pesquisas em Terapia por Captura de Nêutrons em Boro (BNCT) no IPEN, junto ao reator IEA-R1. A técnica de BNCT vem sendo estudada como uma opção seletiva e segura de tratamento para tumores cancerígenos resistentes ou considerados não tratáveis pelas técnicas convencionais, por exemplo, o Glioblastoma Multiforme - tumor cancerígeno no cérebro. Foram realizadas medições de fluxos de nêutrons térmicos, epitérmicos e rápidos bem como das doses devido a nêutrons, e radiação gama na posição de amostra, utilizando-se detectores de ativação tipo folha e dosímetros termoluminescente. Para determinação da intensidade e do espectro de energia de nêutrons, foi utilizado um conjunto de folhas de ativação de energias limiares distintas, irradiadas na instalação e analisadas com um detetor semicondutor de Germânio hiper puro acoplado a um sistema eletrônico adequado para espectrometria gama e os resultados processados com o código SAND-BP. As doses devidas a radiação gama e nêutrons foram determinadas utilizando dosímetros termoluminescentes: TLD-400 (sensível a gama); TLD-600 (sensível a nêutrons) e TLD-700 (sensível a gama). Os TLDs foram selecionados e usados para a obtenção das curvas de calibração - resposta do dosímetro versus dose - de cada uma dos três tipos de TLD, as quais foram utilizadas para calcular as doses devidas a nêutrons e gama na posição de amostra. O campo de radiação na posição de irradiação de amostra foi caracterizado fluxo para nêutrons térmicos de 1.39.108 ± 0,12.108 n/cm2s a dose devido a nêutrons térmicos é três vezes maior que as devido a radiação gama, essas medidas comprovam a reprodutibilidade e consistência dos resultados experimentais obtidos. Considerando os resultados obtidos, verificou-se que o campo de nêutrons e radiação gama atende para pesquisa em BNCT. NEUTRON / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
64

Medida do perfil de dose no aluminio, irradiado com raios gama de captura de neutrons termicos, utilizando o dosimetro termoluminescente CaSO sub(4):Dy

FEDERICO, CLAUDIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:11Z (GMT). No. of bitstreams: 0 / Radiação gama com energias maiores que 1,25 MeV são usualmente encontradas em ambientes de reatores, aceleradores de partículas e campos de radiação de origem cósmica. Nestas energias, a resposta de um dosímetro varia fortemente com a espessura de material absorvedor, até atingir um valor máximo conhecido como espessura de equibl^rio de partículas carregadas. O objetivo principal do presente trabalho foi a determinação experimental do perfil de dose absorvida por uma amostra de alumínio, para várias energias de feixes de raios gama, de forma a obter uma relação entre a energia média do campo de radiação gama e a espessura de equilíbrio de partículas carregadas para o alumínio. Os dosímetros foram irradiados com radiação gama produzida pela captura de neutrons térmicos em 23 materiais alvos no arranjo experimental montado no canal tangencial do reator do IPEN-CNEN/SP. Na determinação da camada de equilíbrio de partículas carregadas, foi ajustada aos dados experimentais uma função semi-empirica que permitiu obter a espessura de ETPC (Equilíbrio Transitório de Partículas Carregadas) para cada espectro de radiação gama utilizado neste trabalho, com energia média variando no intervalo de 3,26 a 7,85 MeV. Os resultados experimentais do presente trabalho permitiram obter uma relação entre a energia média do campo de radiação gama e a espessura de ETPC, que apresenta uma excelente concordância com o alcance corrigido dos elétrons gerados naquela energia. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
65

Caracterização de dosímetros semicondutores e suas aplicações em técnicas especializadas em radioterapia / Characterization of Semiconductors Dosimeters and their Applications in Specialized Techniques in Radiation Therapy.

Fernanda Ferretti de Oliveira 21 December 2012 (has links)
Introdução: A Radioterapia é frequentemente utilizada no tratamento do câncer, seja como uma modalidade simples ou em combinação com outras modalidades, tais como a cirurgia e a quimioterapia. Com o objetivo de eliminar células não desejadas no organismo humano, utiliza-se de radiações ionizantes para provocar a destruição de células tumorais pela absorção da energia da radiação incidente. A principal dificuldade encontrada em radioterapia é que as células tumorais não são tratadas isoladamente, isto é, o dano da radiação não é restrito somente às células tumorais, mas afeta também as células normais. Assim sendo, é essencial que a dose de radiação liberada nos tecidos normais seja tão baixa quanto possível para minimizar o risco de efeitos colaterais provocados pelos tratamentos radioterápicos. Objetivos: O objetivo deste trabalho é a caracterização de dosímetros semicondutores e dosímetros termoluminescentes e suas aplicações em técnicas não convencionais de Radioterapia. A partir da caracterização será possível a implementação dos dosímetros como sistema de dosimetria in vivo em teleterapia com feixe de fótons, visando atender as necessidades prementes do Serviço de Radioterapia do HCFMRP em implantar a técnica de irradiação de corpo inteiro e em realizar o controle de dose administrada ao paciente. Metodologia e Resultados: Diodos semicondutores foram caracterizados de acordo com o fator campo, angulação, taxa de dose, temperatura e fator bandeja, para obtenção dos fatores de correção. Verificou-se que a variação da resposta dos diodos com a temperatura, angulação e taxa de dose não foi significativa. Fatores campo foram calculados e registrados para campos de 3x3 cm 2 a 40x40cm 2 , onde se observou aumento na leitura do diodo com o aumento no campo. A resposta com a taxa de dose apr esentou pouca variação (de 100cGy/min para 300cGy/min a variação foi menor que 1,2%). O fator bandeja encontrado foi de 0,95±0,01 demonstrando que a presença da bandeja provoca diminuição na resposta do detector. Após a caracterização, os diodos foram calibrados em setup TBI para determinação dos fatores de calibração para cada espessura simulada do paciente (DLL). A dosimetria in vivo foi realizada em 3 pacientes submetidos ao tratamento de TBI do HCFMRP. A diferença percentual máxima entre as medidas com diodo e o valor nominal de dose foi de 3,6%, o que está de acordo com o recomendado pelo ICRU (+/- 5%). Os resultados demonstram a viabilidade e confiabilidade da técnica de dosimetria com diodos semicondutores para Controle de Qualidade de dose em tratamento de TBI. Ainda, dosímetros termoluminescentes foram caracterizados quanto à homogeneidade do grupo e a linearidade. Os fatores de calibração individuais foram encontrados e os dosímetros foram aplicados em simulações em setup TBI. Os cálculos de dose das simulações realizadas com os termoluminescentes inseridos nos orifícios de um OSA demonstraram concordância com os valores nominais de dose. Para as regiões do tórax superior e inferior, onde os TLD receberam doses mais elevadas (>150cGy), recomendou-se a utilização de compensadores de dose, para a prática clínica.Uma câmara de ionização foi utilizada como dosímetro de referência em todas as etapas de calibração e caracterização dos diodos e termoluminescentes. Conclusões: Este estudo mostrou que, para tratamentos de irradiação de corpo inteiro, quando o paciente estiver sendo preparado para um transplante de medula óssea, e o planejamento necessitar de uma grande eficácia na distribuição de dose, a metodologia com aplicações de dosímetros semicondutores apresenta-se como uma alternativa viável, precisa e de grande importância para o controle dosimétrico. Assim, ficou evidenciada a importância da utilização do diodo para o Controle de Qualidade, na avaliação da dos e a ser ministrada ao paciente, pelo menos em toda primeira fração de tratamento de TBI. Além disso, ficou demonstrada a aplicabilidade dos dosímetros termoluminescentes para controle dosimétrico, demonstrando o valor da dosimetria termoluminescente como um sistema de verificação de dose e sua eficácia como parte de um programa de garantia de qualidade em Radioterapia. A caracterização dos termoluminescentes evidenciou a possibilidade de aplicação da técnica TL em dosimetria in vivo. / Introduction: Radiation therapy is often used in cancer treatment, either as a single modality or in combination with other modalities, such as surgery and chemotherapy. Aiming to eliminate unwanted cells in the human body, radiation therapy uses ionizing radiation to cause destruction of tumor cells by absorbing the energy of the incident radiation. The main difficulty in radiation therapy is that tumor cells are not separately treated. The radiation damage is not restricted solely to tumor cells, but also affects normal cells. Therefore, it is essential that the radiation dose released in normal tissues is as low as possible to minimize the risk of side effects caused by radiotherapy treatments. Objectives: The objective of this work is the characterization of semiconductor dosimeters and thermoluminescent dosimeters and their applications in non -conventional radiotherapy techniques. After characterization it will be possible to implement the dosimeters as a system of in vivo dosimetry in radiotherapy with photon beam, to meet the pressing needs of the Radiotherapy Service of HCFMRP in deploying the technique of total body irradiation and make the control of dose administered to the patient . Methodology and Results: Semiconductor diodes were characterized according to the field factor, angle, dose rate, temperature and tray factor to obtain the correction factors. It was found that the variation of the response of the diodes with temperature, angle and dose rate was not significant. Field factors were calculated and recorded for fields from 3x3 cm 2 to 40x40cm 2 , wher e there was an increase in the reading of the diode with increasing field. The response with dose rate showed small variation (from 100cGy/min to 300cGy/min the variation was less than 1.2%). The tray factor was 0.95 ± 0.01 demonstrating that the tray decreases detector response. After characterization, the diodes were calibrated in TBI setup for determining the calibration factors for each simulated patient thickness (latero-lateral distance). The in vivo dosimetry was performed in 3 patients undergoing TBI treatment in HCFMRP. The maximum percentage difference between the measurements and the diode nominal dose was 3.6%, which is consistent with that recommended by ICRU (+ / - 5%). The results demonstrate the feasibility and reliability of the dosimetry technique with semiconductor diodes for dose quality control in TBI treatments. Still, dosimeters were characterized by group homogeneity and linearity. The calibration factors were found and individual dosimeters were applied in simulations with TBI setup. The dose calculation of simulations performed with the thermoluminescent inserted in holes of the phantom showed agreement with the nominal dose. For regions of the upper and lower thorax where TLD received higher doses (> 150cGy) it was recommended the use of compensating dose in clinic. An ionization chamber dosimeter was used as reference in all stages of calibration and characterization of diodes and thermoluminescents. Conclusions: This study showed that, for total body irradiation treatments, when the patient is being prepared for a bone marrow transplant, and planning requires a great effect on the dose distribution, the methodology with semiconductor dosimeters presented a viable alternative, and has great importance for the dosimetric control. The study proved the importance of diode semiconductors for quality control, for evaluation of the dose to be administered to the patient, at least throughout the first fraction of TBI treating. Furthermore, it was demonstrated the applicability of TLD for control quality, demonstrating the value of thermoluminescent dosimetry as a dose verification system and its effectiveness as part of a program of quality assurance in radiotherapy. The characterization of thermoluminescent showed the possibility of applying the TL technique in in vivo dosimetry.
66

Estimativa da dose e risco em pacientes Pediátricos devido a exames radiográficos dos Seios da face

PINTO, Beatriz Villa-­‐Chan Cantalupo 31 May 2015 (has links)
Submitted by Haroudo Xavier Filho (haroudo.xavierfo@ufpe.br) on 2016-04-20T17:12:27Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO FINAL PARA IMPRESSÃO CAPA DURA.compressed.pdf: 5438350 bytes, checksum: 6a32a2d9accc05fb896d407a8a699c4b (MD5) / Made available in DSpace on 2016-04-20T17:12:27Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO FINAL PARA IMPRESSÃO CAPA DURA.compressed.pdf: 5438350 bytes, checksum: 6a32a2d9accc05fb896d407a8a699c4b (MD5) Previous issue date: 2015-05-31 / CAPES / FACEPE / No presente trabalho, foi realizado um levantamento das doses recebidas por pacientes pediátricos, em exames radiográficos convencionais dos seios da face, realizados no Recife, PE. Para a realização do estudo, foram selecionados dois hospitais que atendem ao Sistema Único de Saúde, com alta demanda de exames pediátricos. Os dados dos pacientes e os parâmetros de irradiação utilizados em 159 exames radiográficos dos seios da face de crianças, com idades entre 0 e 15 anos, foram coletados, sendo 103 radiografias realizadas na projeção lateral (radiografia cavum) e 56 radiografias realizadas nas projeções pósteroanteriores em fronto-naso (FN) e mento-naso (MN) (radiografias Caldwell e Waters, respectivamente). Inicialmente, foram efetuadas as avaliações de desempenho dos dois equipamentos de raios X pertencentes aos hospitais. A partir dos valores dos rendimentos dos tubos de raios X e dos parâmetros de irradiação empregados nos exames, foram estimados os valores de kerma no ar na superfície de entrada (Ka,e) e produto kerma no ar-área (PK,A). Os valores de kerma no ar nas regiões dos olhos e da tireoide foram estimados utilizando dosímetros termoluminescentes (TLD-100). As doses absorvidas médias nos órgãos e a dose efetiva foram estimadas com o software PCXMC® a partir dos dados antropométricos, parâmetros de irradiação e do kerma no ar incidente (Ka,i), obtido com o rendimento. Os resultados mostraram que os valores de Ka,e variaram entre 0,065 mGy e 1,113 mGy, para radiografias cavum, entre 0,13 mGy e 7,99 mGy, para radiografias na incidência Caldwell e entre 0,13 mGy e 10,12 mGy, para radiografias na incidência Waters. Os valores do kerma no ar na região dos olhos variaram entre 0,001 mGy e 0,968 mGy, nas radiografias cavum, e 0,011 mGy e 0,427 mGy, nas incidências Caldwelll e Waters (conjuntamente). Na região da tireoide, os valores de kerma no ar variaram entre 5 μGy e 932 μGy, para as radiografias cavum, e 2 μGy e 972 μGy, para as incidências Caldwell e Waters. 90% dos valores de Ka,e estimados para os exames realizados no Hospital B encontram-se dentro do recomendado pela comunidade britânica, enquanto todos no Hospital A encontram-se acima. O fato do Hospital B apresentar valores de Ka,e dentro do aconselhado não significa que seu serviço esteja otimizado, devido a grande quantidade de filmes rejeitados, cuja imagem apresentava-se clara e inapropriada para o diagnóstico, elevando a dose final recebida pelo paciente pela repetição do exame. Os altos valores de Ka,e devem-se, principalmente, à utilização indiscriminada da grade antiespalhamento, não recomendada para pacientes desta idade. Os valores de PK,A variaram entre 5,7 mGy.cm2 e 92,3 mGy.cm2 para as radiografias cavum, entre 24,4 mGy.cm2 e 340,3 mGy.cm2 para as radiografias Caldwell e, entre 34,0 mGy.cm2 e 378,3 mGy.cm2 para as radiografias Waters. A partir dos dados pode-se concluir que há necessidade de otimização dos procedimentos radiográficos. / In this study, a survey was conducted in order to assess doses received by pediatric patients ongoing conventional radiographs of the sinuses, performed in Recife, PE. For the study, two hospitals of SUS (Sistema Único de Saúde), with high demand for pediatric examinations, were selected. Patient data and irradiation parameters were collected for 159 radiographs of the children’s sinuses with ages between 0 and 15. Among those, 103 radiographs were taken on the lateral projection (cavum radiography) and 56 radiographs were taken in posteroanterior projections in fronto-naso (FN) and mento-naso (MN) (Caldwell and Waters radiographs, respectively). Initially, the performance of the two X-ray equipment was evaluated. Air kerma values at the entrance surface (Ka,e), and air kerma area product (PK,A) were estimated using X-ray tubes output and irradiation parameters used in the examinations. Air Kerma values on the eyes and thyroid were estimated using thermoluminescent dosimeters (TLD-100). The average absorbed organ doses and effective dose were estimated at the PCXMC® software using the anthropometric data, irradiation parameters and the incident air kerma (Ka,i) obtained with the x-ray tube output. The results showed that Ka,e values varied between 0.065 and 1.113 mGy for cavum radiographs; between 0.13 and 7.99 mGy for Caldwell’s view; and between 0.13 and 10.12mGy for Waters’ view. The air kerma values in at the eye region varied from 0.001 mGy to 0.968 mGy for cavum radiographs, and from 0.011 mGy to 0.427 mGy for Caldwell and Waters’ views (together). In the thyroid region air kerma values ranged from 5 μGy to 932 μGy for cavum view and from 2 μGy to 972 μGy for Caldwell and Waters’ views. Tests performed at Hospital B have shown that 90% of the Ka,e values estimated during exams are within the recommended values by British Commonwealth, while all the Ka,e values in the Hospital A were above it. However, even though Hospital B presented Ka,e values within recommended values, this service was not optimized, due to the large amount of rejected films, whose image were inappropriate for diagnosis resulting in increased dose by the patient re-examination. The high Ka,e values are due mainly to the indiscriminate use of anti-scatter grid, not recommended for patient ages assessed in this study. PK,A values varied between 5.7 and 92.3 mGy.cm2 for cavum radiographs, between 24.4 and 340.3 mGy.cm2 for Caldwell’s view and between 34.0 and 378.3 mGy.cm2 for Waters’ view. Thus, it was concluded that there is need for optimization of radiographic procedures.
67

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
68

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, englobando assim um amplo intervalo de doses de diferentes tipos de radiações. Para assegurar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que respondam a diferentes tipos de radiações. Neste trabalho foi realizada a caracterização dosimétrica de amostras de BeO utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) comparando-se as respostas para as radiações alfa, beta e X e propondose um sistema adequado para sua utilização em monitoração de feixes destas radiações. Dentre os principais resultados obtidos estão: alta sensibilidade à radiação beta para ambas as técnicas empregadas, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), uma dependência energética máxima da radiação X de 28% para técnica TL, e de apenas 7% para a técnica OSL, dentro dos intervalos de energia estudados. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria das radiações ionizantes X, alfa e beta, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Pelos resultados obtidos, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico e radioterapia. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
69

Projeto, construção e caracterização de um dosímetro para radiação de nêutrons / Design, construction and characterization of a dosimeter for neutron radiation

Souto, Eduardo de Brito 30 March 2007 (has links)
Com o objetivo de monitorar o crescente número de trabalhadores potencialmente expostos à radiação de nêutrons, foi projetado e desenvolvido um dosímetro individual para campos mistos nêutron-gama. O dosímetro proposto foi caracterizado para o espectro de energia de uma fonte de Amerício-Berílio e para o intervalo de dose de interesse da proteção radiológica (até 20 mSv). Para tanto utilizou-se a dosimetria termoluminescente de albedo e a dosimetria de traços nucleares, técnicas consagradas na literatura internacional, empregando materiais de fabricação nacional e de baixo custo. Um policarbonato comercial, denominado SS-1, foi caracterizado para aplicação como detector sólido de traços nucleares. Os parâmetros para revelação química e ampliação dos traços, assim como a metodologia de avaliação dos detectores foram determinados. Estudou-se a resposta dos detectores TLD-600, TLD-700 e SS-1 em campos mistos nêutrongama de uma fonte de Amerício-Berílio e definiu-se um algoritmo para cálculo da dose de nêutrons e de radiação gama. A razão entre as respostas para nêutrons térmicos, de albedo e rápidos permite analisar o espectro ao qual o dosímetro foi submetido e corrigir a resposta do detector de traços para variações no ângulo de incidência da radiação. O novo dosímetro está pronto e apresenta desempenho para ser usado como dosímetro de nêutrons no Brasil. / An individual dosimeter for neutron-gamma mixed field dosimetry was design and developed aiming monitoring the increasing number of workers potentially exposed to neutrons. The proposed dosimeter was characterized to an Americium-Beryllium source spectrum and dose range of radiation protection interest (up to 20 mSv). Thermoluminescent albedo dosimetry and nuclear tracks dosimetry, traditional techniques found in the international literature, with materials of low cost and national production, were used. A commercial polycarbonate, named SS-1, was characterized for solid state tack detector application. The chemical etching parameters and the methodology of detectors evaluation were determined. The response of TLD-600, TLD-700 and SS-1 were studied and algorithms for dose calculation of neutron and gamma radiation of Americium- Beryllium sources were proposed. The ratio between thermal, albedo and fast neutrons responses, allows analyzing the spectrum to which the dosimeter was submitted and correcting the track detector response to variations in the radiation incidence angle. The new dosimeter is fully characterized, having sufficient performance to be applied as neutron dosimeter in Brazil.
70

Desenvolvimento de procedimentos e metodologia de controle para aplicação de boas práticas de fabricação (BPF) na irradiação de sangue humano / Procedures development and methodology of control for application of good manufacture practices (GMP) on human blood irradiation

Boghi, Claudio 18 February 2008 (has links)
A irradiação do sangue humano é usada para evitar a TA-DECH (\"transfusão associada a doença do enxerto contra hospedeiro\"), um raro mas devastador efeito adverso dos leucócitos presentes em componentes de sangue de doadores. Normalmente esta prática de irradiação é executada para a eliminação física de leucócitos. A implementação de procedimentos permitirá que a dose apropriada, dentro de uma faixa de 25 Gy a 50 Gy, seja absorvida pelas bolsas de sangue coletadas em um banco de sangue. Os estudos para estabelecer os procedimentos de BPF (Boas Práticas de Fabricação) foram desenvolvidos baseados na norma ISO 11137 Esterilização de produtos médicos Requisitos para validação e controle de rotina Esterilização por radiação. Dois sistemas dosimétricos foram usados para o mapeamento de dose durante os estudos da qualificação do irradiador, carregamento de produto, validação de processo de irradiação e auditoria. O dosímetro CaSO4:Dy apresentou dificuldades em relação à incerteza na medição da dose, estabilidade, rastreabilidade e calibração. Os dosímetros PMMA e Gafchromic mostraram uma melhor performance e foram adotados para estudos de qualificação de irradiadores necessários para a implantação de BPF. Os testes de irradiação foram realizados em um irradiador Gammacell 220. Os procedimentos desenvolvidos podem ser adaptados para diferentes tipos de irradiadores gama, permitindo a implantação de um programa de garantia da qualidade e BPF para irradiação de sangue. / The irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease), a rare but devastating adverse effect of leukocytes present in blood components for a immunocompetent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of leukocytes. The implementation of the procedures will assure that the properly dose in a range of 25 Gy to 50 Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies of the procedures in order to establish a GMP (Good Manufacturing Practices) were developed under the guidelines of the standard ISO 11137 Sterilization of health care products Requirements for validation and routine control Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO4:Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, traceability and calibration. The PMMA and Gafchromic dosimetric systems have shown a better performance and were adopted on studies of irradiators qualification that are necessary to implementation of GMP. The irradiation tests have been done in a Gammacell 220 irradiator. The developed procedures can be adapted for different kinds of gamma irradiators, allowing implanting a quality assurance program and a GMP for blood irradiation.

Page generated in 0.0762 seconds