• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 10
  • 10
  • 10
  • 8
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da distribuição das doses ocupacionais em operações de manutenção e intervenção em áreas restritas do Centro de Radiofarmácia do IPEN / Ocupational doses distribuition analysis in operation of maintenance and interventions in restricted areas at Radiofarmacy Center of IPEN

MACHADO, JESSICA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:34Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
2

Análise da distribuição das doses ocupacionais em operações de manutenção e intervenção em áreas restritas do Centro de Radiofarmácia do IPEN / Ocupational doses distribuition analysis in operation of maintenance and interventions in restricted areas at Radiofarmacy Center of IPEN

MACHADO, JESSICA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:34Z (GMT). No. of bitstreams: 0 / Este estudo foi desenvolvido no Instituto de Pesquisas Energéticas e Nucleares - IPEN mais especificamente, no Centro de Radiofarmácia - CR que realiza pesquisa e processamento de radiosótopos como o 99Mo, 131I, 123I, 67Ga, 201Tl, 18F, 177Lu e 153Sm para uso em medicina nuclear. Os radioisótopos são produzidos em escala industrial e a instalação foi projetada para atender aos padrões de segurança radiológica e às exigências da Garantia de qualidade. No CR há profissionais qualificados que realizam as tarefas de manutenção dos equipamentos e instrumentos, instalados nas celas de processamento de radiofármacos, sem os quais não é possível conduzir a produção com segurança e qualidade. Neste estudo foi realizada uma pesquisa denominada Pesquisa de Variáveis, baseada nas operações de manutenções e intervenções em áreas restritas do CR e no levantamento da distribuição de doses nessas tarefas no período de 2005 a 2011. Esta pesquisa tem por objetivo identificar e determinar as principais variáveis que tem impacto sobre a dose do trabalhador. Os resultados obtidos foram apresentados para variável Indivíduo Ocupacionalmente Exposto - IOE, variável Operação, variável Área/Cela, variável Tipo de Tarefa e variável Duração de Operação, em função da variável Dose. O objetivo deste trabalho foi contribuir com melhorias nas operações em áreas restritas que possam resultar em doses individuais mais baixas sem causar alterações significativas na rotina de trabalho. A análise dos resultados mostrou que a Pesquisa a Variáveis identificou os fatores que mais impactam com a dose recebida. São eles variável Operação, variável Área/Cela e variável Tipo de Tarefa. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
3

Avaliação in vitro dos efeitos da radiação ionizante em tecido ósseo bovino por espectroscopia ATR-FTIR e análise dinâmico-mecânica / In vitro evaluation of ionizing radiation effects in bone tissue by FTIR spectroscopy and dynamic mechanical analysis

VELOSO, MARCELO N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:44Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
4

Avaliação in vitro dos efeitos da radiação ionizante em tecido ósseo bovino por espectroscopia ATR-FTIR e análise dinâmico-mecânica / In vitro evaluation of ionizing radiation effects in bone tissue by FTIR spectroscopy and dynamic mechanical analysis

VELOSO, MARCELO N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:44Z (GMT). No. of bitstreams: 0 / A radiação ionizante de fontes de radiação gama ou geradores de raios-x é frequentemente utilizada na ciência médica, como em exames de radiodiagnóstico, radioterapia e esterilização de aloenxertos. A radiação ionizante é capaz de quebrar cadeias polipeptidicas e provocar a libertação de radicais livres, pela radiólise de moléculas de água. A radiação ionizante interage também com o material orgânico a nível molecular, podendo alterar as suas propriedades mecânicas. No caso específico do tecido ósseo, estudos reportam que a radiação ionizante induz alterações nas moléculas de colágeno e reduzem a densidade de ligações cruzadas intermoleculares. O objetivo deste estudo foi verificar as alterações promovidas por diferentes doses de radiação ionizante no tecido ósseo utilizando a técnica de Espectroscopia Transformada de Fourier com Reflexão Total Atenuada (ATR-FTIR), e também a análise dinâmico-mecânica. Amostras de osso bovino foram irradiadas usando irradiador de Cobalto-60, com cinco doses diferentes: 0,01 kGy, 0,1 kGy, 1 kGy, 15 kGy e 75 kGy. Para estudar os efeitos da radiação ionizante sobre a estrutura química do osso foram avaliadas a relação material orgânico por material inorgânico, a relação de sub-bandas de amida I e o índice de cristalinidade. As alterações mecânicas foram determinadas por meio do módulo de elasticidade e do valor do amortecimento. Para verificar se as mudanças químicas e as características mecânicas de osso possuem alguma relação, realizou-se um estudo sobre a correlação entre as análises feitas com os dados espectroscópicos e as análises mecânicas. Foi possível avaliar os efeitos de diferentes doses de radiação ionizante no tecido ósseo. Com a análise por espectroscopia ATR-FTIR, foi possível observar as modificações dos componentes orgânicos e na organização cristais de hidroxiapatita. Também foram observadas alterações no módulo elástico e na tangente de delta (dissipação de energia mecânica). Foram encontradas altas correlações com significância estatística entre a relação das bandas (amida III + colágeno)/v1,v3, PO43- com a tangente de delta, e entre a relação 1/FHMW e o módulo elástico. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
5

Determinação de fatores de escala para estimativa do inventário de radionuclídeos em rejeitos de média e baixa atividade do reator IEA-R1 / Determination of scaling factors to estimate the radionuclide inventory in waste low and intermediate-level activity from the IEA-R1 reactor

TADDEI, MARIA H.T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:50Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
6

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
7

Desenvolvimento de método para caracterização de embalados de rejeitos radioativos / Development of a method for the radioisotopic characterization of waste packages

SOUZA, DAIANE C.B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:26Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
8

Determinação de fatores de escala para estimativa do inventário de radionuclídeos em rejeitos de média e baixa atividade do reator IEA-R1 / Determination of scaling factors to estimate the radionuclide inventory in waste low and intermediate-level activity from the IEA-R1 reactor

TADDEI, MARIA H.T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:50Z (GMT). No. of bitstreams: 0 / Em cumprimento às normas que regulam a transferência e deposição final de rejeitos radioativos, o inventário de radionuclídeos de cada embalado contendo tais rejeitos deve ser estimado e declarado. Os limites autorizados são definidos em função das doses de radiação que indivíduos do público podem vir a receber anualmente a partir do repositório. Tais limites se referem principalmente às concentrações de atividade, dadas em Bq/g, dos radionuclídeos presentes nos embalados com rejeitos. A grande maioria dos radionuclídeos emissores de raios-gama pode ter a respectiva concentração de atividade determinada diretamente por medidas externas aos embalados. Entretanto, determinação análoga para os radionuclídeos emissores exclusivos de partículas alfa ou beta, bem como de alguns emissores de raios-gama e/ou raios-X cuja energia, intensidade absoluta de emissão e/ou atividade são muito baixas denominados genericamente Radionuclídeos de Difícil Medição (RDMs) requer procedimentos radioquímicos complexos para isolar a espécie química de interesse dos interferentes presentes nas matrizes de rejeitos. Ademais, nesse caso é necessário coletar amostras de cada embalado, acarretando elevadas doses de radiação para os operadores e altos custos logísticos, decorrentes do grande número de embalados com rejeitos radioativos que necessitam de caracterização em uma instalação nuclear. Uma metodologia alternativa para abordar esse problema consiste em obter correlações empíricas entre alguns radionuclídeos possíveis de serem medidos diretamente, como 60Co e 137Cs denominados Radionuclídeos Chave (RCs) e os RDMs. Essa metodologia, denominada Fator de Escala, foi aplicada no presente trabalho com a finalidade de determinar tais correlações, na forma de Fatores de Escala ou Funções de Correlação, para os principais rejeitos de baixa e média atividades do reator nuclear de pesquisa IEA-R1. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
9

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, englobando assim um amplo intervalo de doses de diferentes tipos de radiações. Para assegurar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que respondam a diferentes tipos de radiações. Neste trabalho foi realizada a caracterização dosimétrica de amostras de BeO utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) comparando-se as respostas para as radiações alfa, beta e X e propondose um sistema adequado para sua utilização em monitoração de feixes destas radiações. Dentre os principais resultados obtidos estão: alta sensibilidade à radiação beta para ambas as técnicas empregadas, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), uma dependência energética máxima da radiação X de 28% para técnica TL, e de apenas 7% para a técnica OSL, dentro dos intervalos de energia estudados. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria das radiações ionizantes X, alfa e beta, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Pelos resultados obtidos, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico e radioterapia. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
10

Desenvolvimento de método para caracterização de embalados de rejeitos radioativos / Development of a method for the radioisotopic characterization of waste packages

SOUZA, DAIANE C.B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:26Z (GMT). No. of bitstreams: 0 / Atualmente, a caracterização dos resíduos radioativos gerados na operação do reator nuclear de pesquisas IEA-R1 está em curso. O reator IEA-R1 é um reator do tipo piscina aberta, moderado e refrigerado por água leve, utilizando dois leitos de resinas de troca iônica e de carvão ativado para purificação de água de refrigeração. Estes meios filtrantes são substituídos quando já não são capazes de manter a qualidade da água dentro dos limites exigidos e são tratados como rejeitos radioativos. Contendo produtos de fissão, ativação e actinídeos que escapam do núcleo do reator para a água da piscina, apresentam altas taxas de dose devido à quantidade de emissores gama de meias-vidas curtas e intermediárias, emissores alfa, elementos transurânicos de meia-vida longa bem como emissores beta puros. A caracterização destes rejeitos, consequentemente, requer métodos de análise radioquímica que incluem a amostragem e o processamento das amostras, resultando em doses elevadas para os trabalhadores. Nesse contexto, o objetivo deste trabalho consistiu em correlacionar os resultados das análises radioquímicas de amostras de rejeitos, com os resultados das medições radiométricas, utilizando a modelagem das taxas de dose em diferentes distâncias da superfície dos embalados. As taxas de dose medidas foram comparadas com os resultados de cálculos . Massa, volume e geometria das fases sólidas e líquidas de cada um dos tambores também foram determinadas, uma vez que o teor de água varia amplamente entre diferentes tambores, e são essenciais para estimar as atividades totais em cada tambor. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0339 seconds