• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 2
  • 1
  • Tagged with
  • 66
  • 66
  • 36
  • 26
  • 18
  • 18
  • 15
  • 12
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação das doses resultantes de procedimentos radiodiagnósticos realizados em medicina veterinária e avaliação das doses secundárias de radiação espalhadas no corpo clínico e nos proprietários dos animais / Evaluation of doses from radiodiagnostic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

VENEZIANI, GLAUCO R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:49Z (GMT). No. of bitstreams: 0 / O objetivo primordial em radiologia veterinária é a produção de radiografias com qualidade diagnóstica, em uma primeira tentativa. Esse objetivo deve atender a três propósitos: (1) diminuir a exposição à radiação do paciente e trabalhadores; (2) diminuir o custo do estudo para o cliente e (3) produzir dados diagnósticos para rápida interpretação e tratamento do paciente. Esse trabalho teve por objetivo a determinação das doses em cães submetidos a radiografias de tórax e abdômen utilizando a técnica da dosimetria termoluminescente (TL). As doses de radiação foram avaliadas com a utilização de dosímetros termoluminescentes de sulfato de cálcio dopado com disprósio (CaSO4:Dy) e fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti). Os resultados obtidos indicam que é extremamente importante a avaliação das doses de radiação envolvidas em procedimentos diagnósticos de radiologia veterinária, para a avaliação das doses nos animais e para ser usado como um parâmetro para a monitoração individual dos proprietários de animais, que auxiliam no posicionamento, e para a proteção dos trabalhadores ocupacionalmente expostos nas Clínicas de Radiologia Veterinária. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
62

Panorama das exposições médicas em radiologia convencional no Estado de São Paulo / Overview of the medical exposures in coventional radiology in the State of São Paulo

Marcelo Baptista de Freitas 07 March 2005 (has links)
A dosimetria de pacientes associada à avaliação das condições de funcionamento dos equipamentos médicos e aos procedimentos empregados na realização dos exames, desempenha um papel fundamental no sistema de proteção radiológica das exposições médicas. Nesse sentido, foi realizado um levantamento em grande escala das doses recebidas pelos pacientes submetidos a exames radiológicos convencionais realizados em uma amostra representativa de estabelecimentos de saúde do estado de São Paulo. Nesse levantamento foi empregado um kit dosimétrico postal originalmente desenvolvido, que permitiu a determinação da dose de entrada na pele (DEP) através da técnica de dosimetria termoluminescente. Paralelamente foram realizadas visitas in-loco a uma sub-amostra de estabelecimentos, onde as condições de funcionamento dos equipamentos de raios X médicos e do sistema de imagem foram avaliadas empregando-se procedimentos e equipamentos já estabelecidos em protocolos de controle de qualidade. O estudo completou-se com a elaboração de um catálogo de espectros na faixa de energia do radiodiagnóstico, que, através de procedimento desenvolvido, permitiu inferir espectros equivalentes em equipamentos médicos. Na determinação dos espectros foi empregado um detector semicondutor de telureto de cádmio e zinco (CdZnTe), cujas curvas de eficiência e escape foram determinadas experimentalmente para realização do processo de correção dos espectros (stripping procedure). O processo de amostragem de estabelecimentos de saúde realizado neste estudo permitiu verificar a distribuição de equipamentos de diagnóstico por imagem e a freqüência de exames radiológicos no estado de São Paulo. A partir desses resultados foram escolhidos os exames de tórax, crânio (e seios da face) e coluna para avaliação de DEP, uma vez que os mesmos apresentam as maiores freqüências anuais de exames por 1.000 habitantes: 100, 46 e 29, respectivamente. Na técnica de amostragem dos estabelecimentos de saúde incluídos neste estudo foi empregado como critério de estratificação a quantidade anual de exames radiológicos associados ao município de localização do estabelecimento. Do total de 200 estabelecimentos sorteados, 50 participaram da primeira etapa e 38 da segunda. Um total de 83 salas de exames (ou equipamentos) e 868 pacientes foram incluídos, e um conjunto de 1415 valores de DEP foi determinado. O resultado da distribuição dos valores de DEP permitiu determinar os chamados níveis de referência, que, no caso de pacientes adultos, se mostraram bastante semelhantes aos encontrados em outros estudos internacionais. No caso de pacientes infantis, a situação é bem diferente, obtendo-se valores pelo menos 2 vezes superiores a outros recomendados internacionalmente para a radiografia infantil mais freqüente (tórax). Esse fato sugere que as práticas empregadas na realização dos exames devem ser revisadas e que recomendações específicas a esse grupo de pacientes, a partir de estudos dirigidos, sejam publicadas. Constatou-se também alguns casos de DEP elevada pelo uso desnecessário de radioscopia de localização. Os testes de desempenho dos equipamentos e a avaliação das imagens realizadas sugerem que há possibilidade de melhoria das condições de realização dos exames, sem perda de informação diagnóstica presente na imagem e com redução das doses. Alguns espectros de raios X determinados experimentalmente apresentaram divergência em relação a outros catálogos já estabelecidos, numa faixa específica de energia do espectro (entre 25 e 40 keV). Para a sua utilização em situações práticas há necessidade de algumas correções na curva de eficiência, o que não inviabiliza a metodologia e os procedimentos estabelecidos. De forma geral, os resultados encontrados neste estudo permitem traçar um panorama das exposições médicas em radiologia convencional no estado de São Paulo, contribuindo para o aperfeiçoamento de futuras pesquisas que sejam realizadas na área, ou mesmo, para a implementação de políticas públicas. / Patients dosimetry, associated with the assessment of the performance of the radiological equipment and of the series of procedures employed in the accomplishment of the examinations, plays fundamental role in the radiation protection system of medical exposures. Therefore, a large-scale survey of absorbed doses was carried out in health services localized in the state of São Paulo, including patients submitted to conventional radiological examinations. In this survey a postal dosimetric kit, originally developed, was employed. It allows the evaluation of the entrance surface dose (ESD) to patients with thermoluminescence dosimeters. Also a series visits to a sub-sample of services was carried out, giving rise to the in-loco evaluation of the performance of the medical x-ray equipment and of the image system, using procedures and equipments already established in protocols of quality control. The study is completed with the elaboration of a catalogue of x-ray spectra, which provides means to infer the spectra generated by medical x-ray equipments. Measurements of x-ray spectra were carried out with a cadmium zinc telluride detector (CdZnTe), and the stripping procedure was performed taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined in this work. The stratified sampling technique furnished important data on the distribution of equipments and the annual frequency of examinations performed in the state of São Paulo. From these results radiological examinations of the chest, skull and sinus, and spine were selected for the evaluation of ESD, as their annual frequencies are the highest observed: 100, 46 and 29 per thousand inhabitants, respectively. The number of x-ray examinations carried out annually in the cities of the state was employed as the stratification criterion to construct the sample. From a total of 200 health services sampled, 50 agreed to participate of the first stage, and 38 of the second. A total of 83 rooms (or x-ray equipments) and 868 patients was included, and a set of 1415 values of ESD was measured. Diagnostic reference levels were determined with the outcomes of the distribution of ESD. For adult patients, the reference levels achieved are very similar to others obtained in international surveys. However, as far as pediatric patients are concerned, the situation is very different: the values found in this survey are twice larger than the international recommendations to chest radiography of children. This points out that the practices need to be revised and that specific recommendations to this patient group, following specific surveys, should be provided. Also, a series of high ESD values due to unnecessary localizing radioscopy were detected among our data. The results of the equipment performance tests and of the evaluation of image quality suggest that it is possible to improve the conditions of the examinations and to reduce doses to patients, without impairment of the diagnostic information. Some of the experimentally determined x-ray spectra show a discrepancy, when compared to other catalogue spectra, in a particular energy range 25 to 40 keV. The practical application of them will require some corrections in the efficiency curve, but the established methodology and procedures remain legitimate. In an extensive approach, the results of this study supply a panorama of medical exposures in conventional radiology in the state of São Paulo, contributing with resources to future research in the field and also to governmental actions.
63

Emprego do NCNP no estudo dos TLDs 600 e 700 visando a implementação da caracterização do feixe de irradiação na instalação de BNCT do IEA-R1 / Employment of MCNP in the study of TLDs 600 and 700 seeking the implementation of radiation beam characterization of BNCT facility at IEA-R1

CAVALIERI, TASSIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:33Z (GMT). No. of bitstreams: 1 19174.pdf: 31751 bytes, checksum: 7f1e1ac2bd5fcea7b8edbb1e6ba7a12b (MD5) / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
64

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
65

Emprego do NCNP no estudo dos TLDs 600 e 700 visando a implementação da caracterização do feixe de irradiação na instalação de BNCT do IEA-R1 / Employment of MCNP in the study of TLDs 600 and 700 seeking the implementation of radiation beam characterization of BNCT facility at IEA-R1

CAVALIERI, TASSIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:33Z (GMT). No. of bitstreams: 1 19174.pdf: 31751 bytes, checksum: 7f1e1ac2bd5fcea7b8edbb1e6ba7a12b (MD5) / A Terapia de Captura de Nêutron por Boro (BNCT) é uma terapia de combate ao câncer bimodal, na qual a energia útil da terapia vem da reação nuclear que ocorre pelo Boro quando irradiado com nêutrons térmicos. No IPEN há uma instalação de pesquisas em BNCT, na qual o feixe de radiação contendo nêutrons é proveniente do reator IEA-R1. Como condição desta terapia é necessário realizar a dosimetria do feixe de radiação, que atualmente é feito com o uso de folhas de ativação, para cálculo do fluxo de nêutrons, e do dosímetro TLD 400, para estimativa da dose gama. Para campos mistos de nêutrons e gamas, a Comissão Internacional de Unidades e Medidas (ICRU) recomenda o uso de dosímetros com sensibilidades distintas para as componentes do feixe, como o caso do par TLD 600 e TLD 700 que apresentam sensibilidades distintas a nêutrons térmicos, devido à diferente quantidade do isótopo 6Li em sua composição, o qual apresenta uma alta seção de choque para nêutrons térmicos. Este trabalho constou da realização de simulações e experimentos visando a implementação da metodologia de dosimetria utilizando o par TLD 600 e TLD 700 e sua comparação com a metodologia atualmente utilizada pelo grupo de pesquisa em BNCT, que utiliza o TLD 400. Portanto, foi realizado um estudo das respostas de cada um destes TLDs a partir de irradiações em diferentes campos e sempre utilizando simulações com o MCNP para fornecer a discriminalização das componentes de dose depositadas em cada TLD. Foram realizadas varias irradiações em campo de gama puro e em campo misto de nêutrons e gamas para o estudo da reprodutibilidade destes TLDs. Este estudo mostrou que mesmo TLDs do mesmo tipo têm sensibilidades distintas, e assim foi criado um Fator de Normalização para cada um dos TLDs, eliminando assim a necessidade de selecionamento. Foi realizado um estudo sobre a diferença das respostas destes TLDs devido à diferentes campos. Este estudo mostrou ser possível estimar o fluxo relativo entre gamas e nêutrons a partir da relação existente entre as duas regiões de interesse dos TLDs 600 e 700. Também foi possível observar que o TLD 700 apresenta resposta para nêutrons, e se a recomendação da ICRU for seguida, a resposta devido à radiação gama será superestimada. Foram obtidas as curvas de calibração dose resposta destes TLDs para campos de gamas puro e campos mistos. Este trabalho propõe o uso desta metodologia com o uso do par TLD 600 e TLD 700, por apresentar maior precisão de resposta frente a atual metodologia que utiliza o TLD 400, porém precauções devem ser tomadas para evitar que a dose gama seja superestimada. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
66

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, englobando assim um amplo intervalo de doses de diferentes tipos de radiações. Para assegurar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que respondam a diferentes tipos de radiações. Neste trabalho foi realizada a caracterização dosimétrica de amostras de BeO utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) comparando-se as respostas para as radiações alfa, beta e X e propondose um sistema adequado para sua utilização em monitoração de feixes destas radiações. Dentre os principais resultados obtidos estão: alta sensibilidade à radiação beta para ambas as técnicas empregadas, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), uma dependência energética máxima da radiação X de 28% para técnica TL, e de apenas 7% para a técnica OSL, dentro dos intervalos de energia estudados. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria das radiações ionizantes X, alfa e beta, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Pelos resultados obtidos, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico e radioterapia. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1276 seconds