• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 4
  • 2
  • Tagged with
  • 17
  • 8
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da relação entre os índices vasculares placentários e a exposição individual à poluição atmosférica no primeiro trimestre / Evaluation of the placental vascular indices and individual exposure to air pollution in the first trimester

Hettfleisch, Karen 17 February 2016 (has links)
OBJETIVO: Avaliar a influência dos efeitos da poluição atmosférica sobre o volume e a vascularização placentários no primeiro trimestre. MÉTODOS: O presente estudo é uma coorte prospectiva  realizada de outubro de 2011 a março de 2014, em São Paulo, Brasil. Os critérios de inclusão foram: feto único, idade gestacional entre 11 semanas e 13 semanas e 6 dias, ausência de doença materna, ausência de malformações e utilização correta do amostrador passivo individual de poluentes. Os critérios de exclusão foram: gestação gemelar, malformações e abortamento diagnosticados à ultrassonografia, mudança de endereço para fora da área de recrutamento, desistência da paciente, doença materna diagnosticada durante o acompanhamento. A exposição à poluição foi avaliada por 7 a 18 dias, antes da avaliação ultrassonográfica, utilizando-se amostrador passivo individual dos poluentes NO2 e de O3. Após uso do filtro, as gestantes eram avaliadas na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina de São Paulo (FMUSP). Nesse local, elas foram submetidas à ultrassonografia morfológica entre 11 semanas e 13 semanas e 6 dias e à avaliação placentária pela técnica tridimensional associada ao power Doppler. Por meio desse exame foram avaliados quantitativamente o volume da placenta e seus índices vasculares placentários (com o software VOCAL), os quais compreendem: índice de vascularização (IV), índice de fluxo (IF) e índice de vascularização e fluxo (IVF). A influência dos níveis de poluentes na vascularização e volume placentários log-transformada foi analisada utilizando modelos de regressão linear múltipla que controlavam a idade gestacional, índice de massa corpórea, tabagismo, localização da placenta e paridade. RESULTADOS: Foram avaliadas 229 gestantes no primeiro. O aumento dos níveis de NO2 no primeiro trimestre teve um efeito negativo significativo sobre o IV (p = 0,012 e beta = 0,160) e IVF (p = 0,015 e beta = -0,159). Não houve influência de NO2 e O3 no volume placentário ou IF. CONCLUSÃO: A exposição materna ao NO2 foi significativamente associada com diminuição do índice de vascularização e do índice de vascularização e fluxo no primeiro trimestre da gravidez, o que sugere que esse poluente e outros poluentes primários e secundários, os quais estão associados ao NO2, influenciam na placentação, reduzindo sua vascularização / OBJECTIVE: To evaluate the influence of air pollution on the volume and placental vascularization in the first trimester. METHODS: This study is a prospective cohort conducted from October 2011 to March 2014 in São Paulo, Brazil. The inclusion criteria were single fetus, gestational age between 11 weeks and 13 weeks and 6 days, the absence of maternal disease, fetal defects and correct use of passive personal monitors pollutants. The exclusion criteria were twin pregnancy, abortion and malformations diagnosed on ultrasound, change of address out of the area of recruitment, patient abandonment, and maternal disease diagnosed during follow-up. The pollution exposure was evaluated by 7 to 18 days, before the ultrasound evaluation, using passive personal monitors pollutants of NO2 and O3. After using the filter, the pregnant women were evaluated at Obstetrics Department from Hospital das Clinicas of Faculdade de Medicina de São Paulo (FMUSP). In this place, they were subjected to morphological ultrasound between 11 weeks and 13 weeks and 6 days and placental evaluation by the three dimensional ultrasound power Doppler. Through the ultrasound examination were quantitatively evaluated the volume of the placenta and their placental vascular indices (with VOCAL software), which comprise the vascularization index (VI), flow index (FI) and vascularization flow index (VFI). The influence of pollutant levels on logtransformed placental vascularization and volume was analyzed using multiple linear regression models that controlled for gestational age, body mass index, smoking status, placental location and parity. RESULTS: In the first trimester 229 pregnant women were evaluation. NO2 levels increased in the first trimester had a significant negative effect on the VI (p=0.012 and beta= -0.160) and the VFI (p = 0.015 and beta= -0.159). No effect of NO2 and O3 on the log of placental volume or FI was observed. CONCLUSION: NO2 exposure was significantly associated with a diminished Vascularization Index and Vascularization and Flow Index in the first trimester of pregnancy, which suggests that this pollutant and other primary and secondary pollutants that are associated with NO2 influence placentation and decrease vascularization
12

Avaliação do volume orbitário nos avanços frontofaciais / Evaluation of the orbit volume in craniofacial advancements

Antunes, Rodrigo Badotti 09 December 2014 (has links)
Craniofaciossinostose sindrômica (CS) é uma desordem congênita associada às mutações dos genes FGFR1, FGFR2 e FGFR3. Ocasiona uma fusão prematura das suturas craniofaciais, levando à deficiência no crescimento do crânio e terço médio da face. A severidade dos sintomas relacionados à hipertensão intracraniana, aparelho respiratório (síndrome da hipopneia-apneia do sono) e ocular (órbitas rasas, proptose ocular, exorbitismo e falta de proteção do globo ocular), são parâmetros para indicar o procedimento cirúrgico. A tomografia-3D é uma opção atual e pouco utilizada para avaliar os volumes orbitais e a magnitude dos avanços craniofaciais e seus vetores; esse método permite melhor definição das estruturas anatômicas sem distorção das imagens, promovendo uma avaliação adequada dos resultados. Os objetivos do presente estudo foram avaliar os volumes orbitais, os avanços craniofaciais e seus vetores nas osteotomias Le Fort III e Monobloco com uso de aparelhos distratores, a correlação entre os avanços craniofaciais e a variação dos volumes orbitais e determinar a eficácia dos avanços craniofaciais por meio da comparação com índices normais de volumes orbitais. No período de janeiro de 2001 a dezembro de 2012, foram selecionados 20 pacientes submetidos ao alongamento ósseo gradual do terço médio da face, divididos em dois grupos. Grupo LF (n = 9), submetidos à osteotomia Le Fort III e Grupo MB (n = 11), submetidos à osteotomia frontofacial monobloco. A avaliação constou da revisão de prontuários e exames tomográficos, em que foram mensurados o volume orbital pela segmentação de imagens no programa InVesalius e modelagem 3D no programa Magics, e a magnitude dos avanços craniofaciais, e seus vetores, foram medidos no programa Rhinoceros. Os resultados foram submetidos à análise estatística: teste t- Student e ANOVA. No Grupo MB, houve aumento de 8,94 mm3 e 9,84 mm3 para a variação do volume orbital, nas órbitas direita e esquerda, respectivamente; no Grupo LF: 5,70 mm3 e 5,77 mm3, respectivamente, para esses parâmetros. A resultante do avanço médio, para a órbita direita e esquerda no Grupo LF foi 11,36 ± 3,80 mm e 11,11 ± 3,45 mm, respectivamente; já no Grupo MB, foi 14,22 ± 4,12 mm e 14,48 ± 4,49 mm, respectivamente. A correlação entre a resultante do avanço e a variação dos volumes orbitais foi significante no Grupo LF e para a órbita esquerda no Grupo MB. Em conclusão, o procedimento cirúrgico foi eficaz, tanto para o Grupo LF como para o Grupo MB, pois, houve aumento estatisticamente significativo do volume orbital no período pós-operatório; não houve diferença estatisticamente significativa, na avaliação da simetria, entre os volumes orbitais pós-operatórios, direito e esquerdo. Ainda, não houve diferença estatisticamente significante entre os volumes orbitais pósoperatórios quando comparados aos índices de normalidade / Syndromic craniofacial synostosis (CS) is a congenital disorder, which is most often, an autosomal dominant mutation associated to FGFR1, FGFR2 and FGFR3 genes. It causes a premature fusion of craniofacial sutures, leading to deficiency in skull growth and middle-third of the face. The severity of the intracranial hypertension related, respiratory syndrome (hypopneaapnea) and eye (shallow orbits, ocular proptosis, exorbitism and lack of protection of the eyeball) symptoms, are parameters that indicate the surgical procedure. Distraction osteogenesis of the middle-third of the face is currently the chosen technique for the treatment of patients with Craniofacial Synostosis syndrome candidates for the advancement of the middle-third of the face. The 3D-tomography is a current option and seldom used for this purpose; this method allows better definition of anatomical structures without image distortion, providing a more accurate assessment of the results. The objectives of the present study, were to assess quantitatively the craniofacial advancement and its vectors through 3D tomographic images, the osteotomy Le Fort III and Monobloc with use of distractor devices; Also, to evaluate the correlation between the craniofacial advances and the variation of orbital volumes and determine the effectiveness of craniofacial advances through the comparison with normal levels of orbital volumes. From January 2001 to December 2012, 20 patients underwent distraction osteogenesis of the middle-third of the face, divided into two groups. LF group (n = 9) underwent a Le Fort III osteotomy and MB group (n = 11) underwent a monobloc frontalfacial osteotomy. The evaluation consisted of the reviewing of the records and tomographic exams; measured is the orbital volume by image segmentation on the InVesalius software and 3D modeling on Magics software and the magnitude of facial advances, and their vectors, were measured on Rhinoceros software. The results were subject to statistical analysis: t-Student test and ANOVA. In the MB group, there was an increase of 8.94 mm3 and 9.84 mm3 for the variation of the orbital volume, the right and left orbits, respectively; in Group LF: 5.70 mm3 and 5.77 mm3 for these parameters. The resulting of average advance, for right and left orbit in Group LF was of 11.36 ± 3.80 mm, 11.11 ± 3.45mm, respectively; as for group MB it was 14.22 ± 4.12 mm and 14.48 ± 4.49 mm, respectively. Correlation between the results from the progress and the variation of orbital volume was significant in Group LF and left orbit in MB Group. In conclusion, the surgical procedure was effective for both the LF group as for the MB Group because: there was a statistically significant increase in orbital volume on the postoperative period; there was no statistically significant difference in the evaluation of symmetry between the postoperative period left and right orbital volumes. Still, there was no statistically significant difference between the postoperative orbital volumes when compared to normal ranges
13

Avaliação do volume orbitário nos avanços frontofaciais / Evaluation of the orbit volume in craniofacial advancements

Rodrigo Badotti Antunes 09 December 2014 (has links)
Craniofaciossinostose sindrômica (CS) é uma desordem congênita associada às mutações dos genes FGFR1, FGFR2 e FGFR3. Ocasiona uma fusão prematura das suturas craniofaciais, levando à deficiência no crescimento do crânio e terço médio da face. A severidade dos sintomas relacionados à hipertensão intracraniana, aparelho respiratório (síndrome da hipopneia-apneia do sono) e ocular (órbitas rasas, proptose ocular, exorbitismo e falta de proteção do globo ocular), são parâmetros para indicar o procedimento cirúrgico. A tomografia-3D é uma opção atual e pouco utilizada para avaliar os volumes orbitais e a magnitude dos avanços craniofaciais e seus vetores; esse método permite melhor definição das estruturas anatômicas sem distorção das imagens, promovendo uma avaliação adequada dos resultados. Os objetivos do presente estudo foram avaliar os volumes orbitais, os avanços craniofaciais e seus vetores nas osteotomias Le Fort III e Monobloco com uso de aparelhos distratores, a correlação entre os avanços craniofaciais e a variação dos volumes orbitais e determinar a eficácia dos avanços craniofaciais por meio da comparação com índices normais de volumes orbitais. No período de janeiro de 2001 a dezembro de 2012, foram selecionados 20 pacientes submetidos ao alongamento ósseo gradual do terço médio da face, divididos em dois grupos. Grupo LF (n = 9), submetidos à osteotomia Le Fort III e Grupo MB (n = 11), submetidos à osteotomia frontofacial monobloco. A avaliação constou da revisão de prontuários e exames tomográficos, em que foram mensurados o volume orbital pela segmentação de imagens no programa InVesalius e modelagem 3D no programa Magics, e a magnitude dos avanços craniofaciais, e seus vetores, foram medidos no programa Rhinoceros. Os resultados foram submetidos à análise estatística: teste t- Student e ANOVA. No Grupo MB, houve aumento de 8,94 mm3 e 9,84 mm3 para a variação do volume orbital, nas órbitas direita e esquerda, respectivamente; no Grupo LF: 5,70 mm3 e 5,77 mm3, respectivamente, para esses parâmetros. A resultante do avanço médio, para a órbita direita e esquerda no Grupo LF foi 11,36 ± 3,80 mm e 11,11 ± 3,45 mm, respectivamente; já no Grupo MB, foi 14,22 ± 4,12 mm e 14,48 ± 4,49 mm, respectivamente. A correlação entre a resultante do avanço e a variação dos volumes orbitais foi significante no Grupo LF e para a órbita esquerda no Grupo MB. Em conclusão, o procedimento cirúrgico foi eficaz, tanto para o Grupo LF como para o Grupo MB, pois, houve aumento estatisticamente significativo do volume orbital no período pós-operatório; não houve diferença estatisticamente significativa, na avaliação da simetria, entre os volumes orbitais pós-operatórios, direito e esquerdo. Ainda, não houve diferença estatisticamente significante entre os volumes orbitais pósoperatórios quando comparados aos índices de normalidade / Syndromic craniofacial synostosis (CS) is a congenital disorder, which is most often, an autosomal dominant mutation associated to FGFR1, FGFR2 and FGFR3 genes. It causes a premature fusion of craniofacial sutures, leading to deficiency in skull growth and middle-third of the face. The severity of the intracranial hypertension related, respiratory syndrome (hypopneaapnea) and eye (shallow orbits, ocular proptosis, exorbitism and lack of protection of the eyeball) symptoms, are parameters that indicate the surgical procedure. Distraction osteogenesis of the middle-third of the face is currently the chosen technique for the treatment of patients with Craniofacial Synostosis syndrome candidates for the advancement of the middle-third of the face. The 3D-tomography is a current option and seldom used for this purpose; this method allows better definition of anatomical structures without image distortion, providing a more accurate assessment of the results. The objectives of the present study, were to assess quantitatively the craniofacial advancement and its vectors through 3D tomographic images, the osteotomy Le Fort III and Monobloc with use of distractor devices; Also, to evaluate the correlation between the craniofacial advances and the variation of orbital volumes and determine the effectiveness of craniofacial advances through the comparison with normal levels of orbital volumes. From January 2001 to December 2012, 20 patients underwent distraction osteogenesis of the middle-third of the face, divided into two groups. LF group (n = 9) underwent a Le Fort III osteotomy and MB group (n = 11) underwent a monobloc frontalfacial osteotomy. The evaluation consisted of the reviewing of the records and tomographic exams; measured is the orbital volume by image segmentation on the InVesalius software and 3D modeling on Magics software and the magnitude of facial advances, and their vectors, were measured on Rhinoceros software. The results were subject to statistical analysis: t-Student test and ANOVA. In the MB group, there was an increase of 8.94 mm3 and 9.84 mm3 for the variation of the orbital volume, the right and left orbits, respectively; in Group LF: 5.70 mm3 and 5.77 mm3 for these parameters. The resulting of average advance, for right and left orbit in Group LF was of 11.36 ± 3.80 mm, 11.11 ± 3.45mm, respectively; as for group MB it was 14.22 ± 4.12 mm and 14.48 ± 4.49 mm, respectively. Correlation between the results from the progress and the variation of orbital volume was significant in Group LF and left orbit in MB Group. In conclusion, the surgical procedure was effective for both the LF group as for the MB Group because: there was a statistically significant increase in orbital volume on the postoperative period; there was no statistically significant difference in the evaluation of symmetry between the postoperative period left and right orbital volumes. Still, there was no statistically significant difference between the postoperative orbital volumes when compared to normal ranges
14

Análise da dinâmica e quantificação metabólica de imagens de medicina nuclear na modalidade PET/CT. / Analysis of the dynamic and metabolic quantification of nuclear medicine images in the PET/CT modality.

Florez Pacheco, Edward 28 March 2016 (has links)
A presença da Medicina Nuclear como modalidade de obtenção de imagens médicas é um dos principais procedimentos utilizados hoje nos centros de saúde, tendo como grande vantagem a capacidade de analisar o comportamento metabólico do paciente, traduzindo-se em diagnósticos precoces. Entretanto, sabe-se que a quantificação em Medicina Nuclear é dificultada por diversos fatores, entre os quais estão a correção de atenuação, espalhamento, algoritmos de reconstrução e modelos assumidos. Neste contexto, o principal objetivo deste projeto foi melhorar a acurácia e a precisão na análise de imagens de PET/CT via processos realísticos e bem controlados. Para esse fim, foi proposta a elaboração de uma estrutura modular, a qual está composta por um conjunto de passos consecutivamente interligados começando com a simulação de phantoms antropomórficos 3D para posteriormente gerar as projeções realísticas PET/CT usando a plataforma GATE (com simulação de Monte Carlo), em seguida é aplicada uma etapa de reconstrução de imagens 3D, na sequência as imagens são filtradas (por meio do filtro de Anscombe/Wiener para a redução de ruído Poisson caraterístico deste tipo de imagens) e, segmentadas (baseados na teoria Fuzzy Connectedness). Uma vez definida a região de interesse (ROI) foram produzidas as Curvas de Atividade de Entrada e Resultante requeridas no processo de análise da dinâmica de compartimentos com o qual foi obtida a quantificação do metabolismo do órgão ou estrutura de estudo. Finalmente, de uma maneira semelhante imagens PET/CT reais fornecidas pelo Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP) foram analisadas. Portanto, concluiu-se que a etapa de filtragem tridimensional usando o filtro Anscombe/Wiener foi relevante e de alto impacto no processo de quantificação metabólica e em outras etapas importantes do projeto em geral. / The presence of Nuclear Medicine as a medical imaging modality is one of the main procedures utilized nowadays in medical centers, and the great advantage of that procedure is its capacity to analyze the metabolic behavior of the patient, resulting in early diagnoses. However, the quantification in Nuclear Medicine is known to be complicated by many factors, such as degradations due to attenuation, scattering, reconstruction algorithms and assumed models. In this context, the goal of this project is to improve the accuracy and the precision of quantification in PET/CT images by means of realistic and well-controlled processes. For this purpose, we proposed to develop a framework, which consists in a set of consecutively interlinked steps that is initiated with the simulation of 3D anthropomorphic phantoms. These phantoms were used to generate realistic PET/CT projections by applying the GATE platform (with Monte Carlo simulation). Then a 3D image reconstruction was executed, followed by a filtering process (using the Anscombe/Wiener filter to reduce Poisson noise characteristic of this type of images) and, a segmentation process (based on the Fuzzy Connectedness theory). After defining the region of interest (ROI), input activity and output response curves are required for the compartment analysis in order to obtain the Metabolic Quantification of the selected organ or structure. Finally, in the same manner real images provided from the Heart Institute (InCor) of Hospital das Clínicas, Faculty of Medicine, University of São Paulo (HC-FMUSP) were analysed. Therefore, it is concluded that the three-dimensional filtering step using the Ascombe/Wiener filter was preponderant and had a high impact on the metabolic quantification process and on other important stages of the whole project.
15

Análise da dinâmica e quantificação metabólica de imagens de medicina nuclear na modalidade PET/CT. / Analysis of the dynamic and metabolic quantification of nuclear medicine images in the PET/CT modality.

Edward Florez Pacheco 28 March 2016 (has links)
A presença da Medicina Nuclear como modalidade de obtenção de imagens médicas é um dos principais procedimentos utilizados hoje nos centros de saúde, tendo como grande vantagem a capacidade de analisar o comportamento metabólico do paciente, traduzindo-se em diagnósticos precoces. Entretanto, sabe-se que a quantificação em Medicina Nuclear é dificultada por diversos fatores, entre os quais estão a correção de atenuação, espalhamento, algoritmos de reconstrução e modelos assumidos. Neste contexto, o principal objetivo deste projeto foi melhorar a acurácia e a precisão na análise de imagens de PET/CT via processos realísticos e bem controlados. Para esse fim, foi proposta a elaboração de uma estrutura modular, a qual está composta por um conjunto de passos consecutivamente interligados começando com a simulação de phantoms antropomórficos 3D para posteriormente gerar as projeções realísticas PET/CT usando a plataforma GATE (com simulação de Monte Carlo), em seguida é aplicada uma etapa de reconstrução de imagens 3D, na sequência as imagens são filtradas (por meio do filtro de Anscombe/Wiener para a redução de ruído Poisson caraterístico deste tipo de imagens) e, segmentadas (baseados na teoria Fuzzy Connectedness). Uma vez definida a região de interesse (ROI) foram produzidas as Curvas de Atividade de Entrada e Resultante requeridas no processo de análise da dinâmica de compartimentos com o qual foi obtida a quantificação do metabolismo do órgão ou estrutura de estudo. Finalmente, de uma maneira semelhante imagens PET/CT reais fornecidas pelo Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP) foram analisadas. Portanto, concluiu-se que a etapa de filtragem tridimensional usando o filtro Anscombe/Wiener foi relevante e de alto impacto no processo de quantificação metabólica e em outras etapas importantes do projeto em geral. / The presence of Nuclear Medicine as a medical imaging modality is one of the main procedures utilized nowadays in medical centers, and the great advantage of that procedure is its capacity to analyze the metabolic behavior of the patient, resulting in early diagnoses. However, the quantification in Nuclear Medicine is known to be complicated by many factors, such as degradations due to attenuation, scattering, reconstruction algorithms and assumed models. In this context, the goal of this project is to improve the accuracy and the precision of quantification in PET/CT images by means of realistic and well-controlled processes. For this purpose, we proposed to develop a framework, which consists in a set of consecutively interlinked steps that is initiated with the simulation of 3D anthropomorphic phantoms. These phantoms were used to generate realistic PET/CT projections by applying the GATE platform (with Monte Carlo simulation). Then a 3D image reconstruction was executed, followed by a filtering process (using the Anscombe/Wiener filter to reduce Poisson noise characteristic of this type of images) and, a segmentation process (based on the Fuzzy Connectedness theory). After defining the region of interest (ROI), input activity and output response curves are required for the compartment analysis in order to obtain the Metabolic Quantification of the selected organ or structure. Finally, in the same manner real images provided from the Heart Institute (InCor) of Hospital das Clínicas, Faculty of Medicine, University of São Paulo (HC-FMUSP) were analysed. Therefore, it is concluded that the three-dimensional filtering step using the Ascombe/Wiener filter was preponderant and had a high impact on the metabolic quantification process and on other important stages of the whole project.
16

Resolving Local Magnetization Structures by Quantitative Magnetic Force Microscopy / Auflösung lokaler Magnetisierungsstrukturen mittels quantitativer Magnetkraftmikroskopie

Vock, Silvia 22 July 2014 (has links) (PDF)
Zur Aufklärung der lokalen Magnetisierungs- und magnetischen Streufeldstruktur in ferromagnetischen und supraleitenden Materialien wurden magnetkraftmikroskopische (Magnetkraftmikroskopie-MFM) Untersuchungen durchgeführt und quantitativ ausgewertet. Für eine solch quantitative Auswertung muss der Einfluß der verwendeten MFM-Spitzen auf das MFM-Bild bestimmt und in geeigneter Weise subtrahiert werden. Hierzu wurden Spitzenkalibrierungsroutinen und ein Verfahren zur Entfaltung der gemessenen MFM-Daten implementiert, das auf der Wiener Dekonvolution basiert. Mit Hilfe dieser Prozedur können sowohl die räumliche Ausdehnung als auch die Größe der Streufelder direkt aus gemessenen MFM-Bildern bestimmt werden. Gezeigt wurde diese Anwendung für die Durchmesserbestimmung von Blasendomänen in einer (Co/Pd)-Multilage und für die Bestimmung der temperaturabhängigen magnetischen Eindringtiefe in einem supraleitendem BaFe2(As0.24P0.76)2 Einkristall. Desweiteren konnte durch die Kombination von mikromagnetischen Rechnungen und der quantitativen MFM-Datenanalyse die Existenz einer dreidimensionalen Vortex-Struktur am Ende von Co48Fe52-Nanodrähten nachgewiesen werden. Damit ist es gelungen die Tiefensensitivität der Magnetkraftmikroskopie erfolgreich in die Rekonstruktion der vermessenen Magnetisierungsstruktur einzubeziehen.
17

Resolving Local Magnetization Structures by Quantitative Magnetic Force Microscopy

Vock, Silvia 09 May 2014 (has links)
Zur Aufklärung der lokalen Magnetisierungs- und magnetischen Streufeldstruktur in ferromagnetischen und supraleitenden Materialien wurden magnetkraftmikroskopische (Magnetkraftmikroskopie-MFM) Untersuchungen durchgeführt und quantitativ ausgewertet. Für eine solch quantitative Auswertung muss der Einfluß der verwendeten MFM-Spitzen auf das MFM-Bild bestimmt und in geeigneter Weise subtrahiert werden. Hierzu wurden Spitzenkalibrierungsroutinen und ein Verfahren zur Entfaltung der gemessenen MFM-Daten implementiert, das auf der Wiener Dekonvolution basiert. Mit Hilfe dieser Prozedur können sowohl die räumliche Ausdehnung als auch die Größe der Streufelder direkt aus gemessenen MFM-Bildern bestimmt werden. Gezeigt wurde diese Anwendung für die Durchmesserbestimmung von Blasendomänen in einer (Co/Pd)-Multilage und für die Bestimmung der temperaturabhängigen magnetischen Eindringtiefe in einem supraleitendem BaFe2(As0.24P0.76)2 Einkristall. Desweiteren konnte durch die Kombination von mikromagnetischen Rechnungen und der quantitativen MFM-Datenanalyse die Existenz einer dreidimensionalen Vortex-Struktur am Ende von Co48Fe52-Nanodrähten nachgewiesen werden. Damit ist es gelungen die Tiefensensitivität der Magnetkraftmikroskopie erfolgreich in die Rekonstruktion der vermessenen Magnetisierungsstruktur einzubeziehen.:Introduction 6 1 Contrast formation in Magnetic Force Microscopy (MFM) 9 1.1 Type of interactions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.1.1 Relevant interaction forces . . . . . . . . . . . . . . . . . . . . . . . 9 1.1.2 Magnetic interaction mechanisms . . . . . . . . . . . . . . . . . . . 11 1.2 Basic magnetostatics of the tip-sample system . . . . . . . . . . . . . . . . 12 1.2.1 General magnetostatic expressions . . . . . . . . . . . . . . . . . . . 12 1.2.2 Description of the tip sample system . . . . . . . . . . . . . . . . . 14 1.2.3 Magnetostatics in Fourier space . . . . . . . . . . . . . . . . . . . . 15 2 Instrumentation 20 2.1 Scanning Force Microscopy (SFM) . . . . . . . . . . . . . . . . . . . . . . . 20 2.1.1 Measurement principle and operation modes . . . . . . . . . . . . . 20 2.1.2 Dynamic mode SFM . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2.2 Lift mode MFM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2.3 Non-contact MFM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 2.4 Vibrating Sample Magnetometry . . . . . . . . . . . . . . . . . . . . . . . 26 3 Quantitative Magnetic Force Microscopy 28 3.1 The challenge of MFM image inversion . . . . . . . . . . . . . . . . . . . . 28 3.1.1 Description of the problem and state of the art . . . . . . . . . . . 28 3.1.2 The point probe approximations . . . . . . . . . . . . . . . . . . . . 31 3.1.3 The transfer function approach . . . . . . . . . . . . . . . . . . . . 33 3.2 Tip calibration: Adapted Wiener deconvolution . . . . . . . . . . . . . . . 39 3.2.1 Details of the procedure . . . . . . . . . . . . . . . . . . . . . . . . 39 3.2.2 Evaluation of possible errors . . . . . . . . . . . . . . . . . . . . . . 44 3.3 Noise measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 3.4 MFM probes and their specific characteristics . . . . . . . . . . . . . . . . 49 3.5 Calibration samples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 3.6 Detection of tip-sample modification . . . . . . . . . . . . . . . . . . . . . 55 4 Quantitative MFM with iron filled carbon nanotube sensors (Fe-CNT) 56 4.1 The monopole character of Fe-CNT sensors . . . . . . . . . . . . . . . . . . 57 4.1.1 Calibration within the point probe approximation . . . . . . . . . . 57 4.1.2 Calibration results and discussion . . . . . . . . . . . . . . . . . . . 59 4.1.3 Quantitative MFM on a [Co/Pt]/Co/Ru multilayer . . . . . . . . . 62 4.2 Inplane sensitive MFM with Fe-CNT sensors . . . . . . . . . . . . . . . . . 63 4.2.1 Bimodal MFM technique . . . . . . . . . . . . . . . . . . . . . . . . 63 4.2.2 Comparison between calculated and measured in-plane contrast . . 66 5 Quantification of magnetic nanoobjects in MFM measurements 70 5.1 Bubble domains in a [Co/Pd]80 multilayer . . . . . . . . . . . . . . . . . . 71 5.1.1 Micromagnetic model . . . . . . . . . . . . . . . . . . . . . . . . . . 72 5.1.2 MFM image simulation . . . . . . . . . . . . . . . . . . . . . . . . . 72 5.1.3 Results and discussion . . . . . . . . . . . . . . . . . . . . . . . . . 74 5.2 Quantitative assessment of the magnetic penetration depth in superconductors 78 5.2.1 Comparison of methods . . . . . . . . . . . . . . . . . . . . . . . . 79 5.2.2 Experimental determination of the temperature dependent penetration depth in a BaFe2(As0:24P0:76)2 single crystal . . . . . . . . . . . 83 6 Magnetization studies of CoFe nanowire arrays on a local and global scale 87 6.1 Revisiting the estimation of demagnetizing fields in magnetic nanowire arrays 88 6.1.1 Available approaches . . . . . . . . . . . . . . . . . . . . . . . . . . 88 6.1.2 Calculation of demagnetizing fields in nanowire arrays . . . . . . . . 91 6.2 Micromagnetic Simulations . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 6.3 Combination of demagnetizing field calculations and micromagnetic simulation100 6.4 Experimental details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 6.5 Global hysteresis measurements of CoFe nanowire arrays with varying length 104 6.6 Local magnetic characterization of a CoFe nanowire array by quantitative MFM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 6.6.1 Magnetic structure of individual nanowires . . . . . . . . . . . . . . 107 6.6.2 Magnetization reversal of the nanowire array . . . . . . . . . . . . . 110 6.7 Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Conclusions and Outlook 119 Bibliography 121 Acknowledgements 135

Page generated in 0.0714 seconds