• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Degradation of bleaching agents under two different storage conditions

Almutiri, Basil January 2016 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This study was conducted in order to determine if there is any change in the active ingredient of tooth-whitening agents when the products are received from the manufacturer (Baseline), two months, four months, and six months after they are received, under two different storage conditions. Thirty-six products were received from multiple manufacturers: eight with hydrogen peroxide and 28 carbamide with peroxide products. All the bleaching syringes for a specific product were from the same lot. Once the products were received, one sample of each product was stored at room temperature and the other sample was stored in a refrigerator. Assays to determine the baseline concentration were performed within the first two weeks of their arrival and again 2 months, 4 months, and 6 months after receiving the products. All samples were analyzed for peroxide content by using the United States Pharmacopeia recommended method. The results obtained from this study show the following: 1. Bleaching products have different concentrations than what are indicated on the label. 2. Storage of bleaching products for an extended time at room temperature can cause bleaching products to lose some of their potency. 3. The preferable storage condition verified in this study is under refrigeration.
2

Efeito do protocolo clareador na degradação, alteração de pH, eficácia e segurança do gel de peróxido de hidrogênio /

Abreu, Fabrícia Stabile de Abreu. January 2019 (has links)
Orientador: Alessandra Bühler Borges / Coorientadora: Rayssa Ferreira Zanatta / Banca: Cesar Rogério Pucci / Banca: Daniele Mara da Silva Ávila Nogueira / Resumo: O objetivo deste estudo foi avaliar a degradação do peróxido de hidrogênio em altas concentrações (35-40%), durante uma simulação de sessão de clareamento de consultório, utilizando produtos comercialmente disponíveis com dois protocolos de aplicação. Foram medidas também a eficácia clareadora dos géis, a alteração de pH dos mesmos, bem como o potencial de alteração da microdureza e rugosidade superficial do esmalte. Para tal, espécimes de dentes bovinos em forma de disco com 4 mm de diâmetro e 2 mm de espessura (1 mm de esmalte e 1 mm de dentina) foram preparados para tal 105 espécimes, embutidos em resina acrílica, polidos e divididos nos seguintes grupos, de acordo com o tipo de gel clareador: Pola Office Plus (POP - SDI PH-37,5%), Opalescence Boost (OPB - Ultradent PH-40%) e Whiteness HP (WHP - FGM PH-35%). Cada grupo foi dividido em dois subgrupos conforme o protocolo de aplicação (n = 15): com e sem troca do gel clareador durante a sessão de clareamento. A alteração de cor das amostras foi medida por espectrofotometria de acordo com o sistema CIE L*a*b*, antes e após a sessão de clareamento. A superfície do esmalte foi analisada com microdurômetro e perfilômetro, para mensuração da microdureza Knoop (KHN) e rugosidade superficial (Ra). Outros 30 espécimes adicionais em dentes bovinos foram confeccionados para mensuração da concentração do peróxido de hidrogênio e pH. A concentração e pH dos géis foram medidos por meio da titulação com permanganato de potássio (KMnO4) e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the degradation of hydrogen peroxide at high concentrations (35-40%) during a clinic whitening session simulation using commercially available products with two application protocols. The bleaching efficiency of the gels, pH change, as well as the alteration potential of the enamel microhardness and surface roughness (Ra) were measured. For this, disc-shaped bovine tooth specimens of 4 mm diameter and 2 mm thickness (1 mm enamel and 1 mm dentin) were prepared 105 specimens, embedded in acrylic resin, polished, and divided into the following groups according to the type of bleaching gel: Pola Office Plus (POP - SDI PH-37,5%), Opalescence Boost (OPB - Ultradent PH-40%), and Whiteness HP (WHP - FGM PH-35%). Each group was divided into two subgroups, according to the application protocol (n = 15): with and without exchange of the gel during the whitening session. The specimens' color change was measured by spectrophotometry according to the CIE system L*a*b*, before and after the bleaching session. The enamel surface was analyzed with a microhardner and profilometer, to measure the Knoop microhardness and surface roughness (Ra). Another 30 specimens in bovine teeth were made to measure the hydrogen peroxide concentration and pH. The concentration and pH of the gels were measured by titration with potassium permanganate (KMnO4) and by a pH meter and specific electrode, respectively, before and after said application times thereof. The degradation of the gels was calculated as a function of the initial concentration. The results were submitted to the ANOVA test and Tukey's multiple comparison test (5%). All gels presented similar bleaching efficacy (ΔE and ΔE00) comparing SA and MA. There were no significant differences between KHN and Ra means comparing SA and MA for the same gel. Although peroxide degradation significantly increased with time, the final gels concen.. / Mestre
3

EFEITOS DOS AGENTES CLAREADORES NA ADESIVIDADE E NA SUPERFÍCIE DE BRACKETS METÁLICOS / Effects of bleaching agents on adhesiveness and surface of metallic brackets

Bayá, Paola Andrea Zurita 20 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:31Z (GMT). No. of bitstreams: 1 Paola Andrea Zurita Baya.pdf: 5901353 bytes, checksum: 64a11dda533f6676e318b6f0b49bd278 (MD5) Previous issue date: 2014-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study evaluated the effects of bleaching agents on adhesiveness and surface of metallic brackets. To evaluate the bond strength (BS) and adhesive remnant index (ARI) sixty specimens were confectioned, where sixty brackets were bonded to 60 Premolars with the adhesive TransbondTM XT. They were divided randomly into 3 groups (n=20), a control group (CG) wich not received bleaching agent, two experimental groups TWS and TWO where the bleaching agent hydrogen peroxide 10% (Opalescence® TrèswhiteTM Supreme) and hydrogen peroxide 8% (Opalescence® TrèswhiteTM Ortho) were applied respectively. The specimens were submitted to shearing in a universal testing machine (Kratos) with a crosshead speed of 0,5 mm/min. The ARI was evaluated with a magnifying stereomicroscope (20x). For the evaluation of surface roughness 15 new brackets were used, divided into 3 groups (n=5). These groups correspond to a control group (CG) without bleaching agent, and two experimental groups (TWS e TWO). The brackets underwent to the surface roughness test by digital rugosimeter (Surftest SJ 400). The ANOVA test showed no significant difference for the RA (p = 0.3511), Rug (p= 0.10) nor to changes in roughness (p= 0.1024). The Kruskal-Wallis test showed no significant difference for the ARI (p= 0.3732). It was concluded that the use of bleaching agents tested in this study is viable in orthodontic patients. / Este estudo avaliou os efeitos dos agentes clareadores na adesividade e na superfície de brackets metálicos. Para a avaliação da resistência adesiva (RA) e do índice de adesivo remanescente (IAR) foram confeccionados 60 corpos de prova, onde 60 brackets foram colados em 60 pré-molares humanos com o adesivo TransbondTM XT. Foram divididos aleatoriamente em 3 grupos (n=20), um grupo controle (GC) que não recebeu agente clareador, dois grupos experimentais TWS e TWO nos quais foram aplicados o agente clareador peróxido de hidrogênio 10% (Opalescence® TrèswhiteTM Supreme) e peróxido de hidrogênio 8% (Opalescence® TrèswhiteTM Ortho) respectivamente. As amostras foram submetidas a cisalhamento em uma máquina universal de ensaios mecânicos (Kratos) com velocidade de carga de 0,5 mm/min. O IAR foi avaliado com uma lupa estereomicroscópica (20x). Para à avaliação da rugosidade superficial foram utilizados 15 brackets novos, divididos em 3 grupos (n=5). Esses grupos correspondem a um grupo controle (GC) sem agente clareador e dois grupos experimentais (TWS e TWO). Os brackets foram submetidos ao teste de rugosidade superficial pelo rugosímetro digital (Surftest SJ 400, Mitutoyo) O teste ANOVA demonstrou não existir diferença significativa para a RA (p= 0,3511), Rug. (p= 0,10) e nem para alterações da rugosidade (p= 0,1024). O teste Kruskal-Wallis demonstrou não haver diferença significativa para o IAR (p= 0,3732). Concluise que o uso dos agentes clareadores testados no presente estudo é viável em pacientes ortodônticos.
4

Efeito dos agentes clareadores sobre o esmalte dental, a resina composta e a interface dente/restauração / Effect of bleaching agents on the dental enamel, the composite resin and the tooth/restoration interface

Abe, Andréa Tami 10 June 2014 (has links)
Este estudo in vitro teve como objetivo avaliar a dureza do esmalte dental, da resina composta, do adesivo e da camada híbrida em esmalte expostos a agentes clareadores à base de peróxido de hidrogênio a 35%, e analisar a interface dente/restauração com microscopia eletrônica de varredura (MEV). Foram utilizadas 40 coroas dentais de incisivos bovinos, que foram incluídas em resina epóxi. Uma cavidade de 2x2x2mm foi confeccionada no terço médio da face vestibular planificada de cada dente. As cavidades foram restauradas com o adesivo Adper Single Bond 2 e a resina nanoparticulada Filtek Z350 XT, e o polimento foi realizado após uma semana da confecção das restaurações. Os corpos de prova foram divididos em quatro grupos (n=10), correspondente a cada agente clareador à base de peróxido de hidrogênio a 35% utilizado (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). A aplicação dos clareadores foi realizada 24 horas após o polimento, de acordo com as recomendações dos respectivos fabricantes. O valor do pH dos agentes clareadores foi medido no início e no final do procedimento clareador. A dureza dos substratos foi mensurada antes (inicial), imediatamente após o clareamento e após 7 dias de armazenamento em saliva artificial com o equipamento ultramicrodurômetro DUH-211S (Shimadzu). As cargas utilizadas foram de 100mN para o esmalte dental e para a resina composta, e de 10mN para o adesivo e para a camada híbrida em esmalte. Para a análise com MEV, foi confeccionado mais um corpo de prova para cada agente clareador, que foi replicado em resina epóxi a cada tempo de análise. Os testes estatísticos empregados foram a ANOVA de 2 fatores sendo 1 com vinculação (p<0,05) e o teste de Tukey. Quanto à dureza do esmalte e da camada híbrida, os corpos de prova expostos aos agentes TB, HPB e HP não apresentaram alteração da dureza nos três tempos de mensuração. O agente PO foi o clareador que apresentou o valor de pH mais baixo e o único que promoveu uma diminuição da dureza desses substratos imediatamente após sua aplicação, porém após 7 dias de armazenamento em saliva artificial a dureza retornou ao valor inicial. Nenhuma alteração foi observada quanto à dureza da resina composta e do adesivo expostos aos agentes clareadores utilizados. A análise em MEV revelou fendas entre o esmalte dental e o adesivo imediatamente após exposição à maioria dos clareadores. Pode-se concluir que o agente PO foi o único que diminuiu a dureza dos substratos dentais e o que promoveu a maior fenda na interface dente/restauração logo após sua aplicação. Nenhum clareador promoveu alteração da dureza da resina composta e do adesivo. / The aim of this in vitro study was to evaluate the hardness of the dental enamel, the composite resin, the dental adhesive and the enamel hybrid layer exposed to 35% hydrogen peroxide bleaching agents, and to analyze the tooth/restoration interface with scanning electron microscopy (SEM). Forty bovine incisor crowns were embedded in epoxy resin and then the labial surface of the teeth was flatted. One 2x2x2mm cavity was prepared on the middle third of each tooth labial surface. The cavities were restored with the adhesive Adper Single Bond 2 and the nanocomposite resin Filtek Z350 XT. After one week of storage, the restorations were polished. The specimens were divided into four groups (n=10), in correspondence to each 35% hydrogen peroxide bleaching agents used (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). The bleaching procedure was performed 24 hours after polish, according to each manufacturer`s recommendation. The pH value of the bleaching agents was measured before and at the end of the bleaching procedure. Hardness test was performed before, immediately after bleaching and after storage in artificial saliva for 7 days, with the ultramicrohardness tester DUH-211S (Shimadzu). Indentations were performed using 100mN load for dental enamel and composite resin, and 10mN load for adhesive layer and enamel hybrid layer. For SEM analysis, one more specimen was made for each bleaching agent, which was replicated in epoxy resin at each measurement time. The statistical tests used were 2-way ANOVA and Tukey test (p<0,05). Regarding to dental enamel and enamel hybrid layer hardness, the specimens exposed to TB, HPB and HP agents did not present hardness alterations at any measurement time. The PO agent presented the lowest pH value and was the only that promoted hardness decrease on these dental surfaces immediately after application, however, after storage in artificial saliva for 7 days the hardness returned to initial value. No alteration was observed regarding to hardness of composite resin and adhesive exposed to bleaching agents. The SEM analysis revealed gaps between the dental enamel and the adhesive immediately after exposure to majority bleaching agents. In conclusion, the PO agent was the only that promoted hardness decrease on dental surfaces, and the major gap formation in tooth/restoration interface after application. No bleaching agents caused any alteration on composite resin and adhesive hardness.
5

Impacto do clareamento dental de consultório com peróxido de carbamida a 37% na mudança de percepção dos pacientes com o sorriso, alteração de cor e sensibilidade pós-operatória : ensaio clínico controlado randomizado simples-cego / Impact of in-office tooth bleaching with 37% carbamide peroxide on patients' perception of smile, color change and postoperative sensitivity : single-blind randomized controlled clinical trial

Peixoto, Aline Carvalho 28 August 2018 (has links)
The aim of this study was to evaluate the impact of in-office tooth bleaching with 37% carbamide peroxide on patients' perceptions regarding the change in the satisfaction with their smile and on the bleaching procedures and their dental color change results and postoperative sensitivity when compared to 35% hydrogen peroxide. Forty patients were allocated to receive two sessions of in-office tooth bleaching using either 35% hydrogen peroxide (HP) or 37% carbamide peroxide (CP) (n=20). The perception of the smile itself was indicated through a visual analogue scale (VAS), and the procedures of tooth bleaching and its results were evaluated by means of a questionnaire applied 1 week after the first session and 30 days after the last one. Patients' sensitivity level was recorded during and up to 24 hours after bleaching procedure. Dental sensitivity was assessed using the verbal and EVA scales. It was calculated the absolute and relative risks to tooth sensitivity. The efficacy of bleaching procedures was evaluated with a spectrophotometer one week after each session and 30 days after the last one. Data from color evaluation (ΔL*, Δa*, Δb* and ΔE) were individually submitted to 2-way repeated measures ANOVA followed by Tukey’s post hoc test. Data from the level of sensitivity were analyzed by test Mann- Whitney. Absolute and relative risks were compared by the Fisher Exact test. It was observed a lower risk and level of tooth sensitivity for CP, while the difference between the bleaching agents disappeared after 24 hours. An increased bleaching effect was observed for HP, mainly due to an improved reduction of redness and yellowness. Participants perceived improved tooth bleaching for HP and reduced sensitivity for CP, but no differences regarding the comfort of the techniques were noted. An improved bleaching effect was observed for HP. CP resulted in reduced tooth sensitivity but also reduced the tooth bleaching efficacy. However, both bleaching agents resulted in high levels of patient satisfaction. / O objetivo deste estudo foi avaliar o impacto do clareamento dental de consultório com peróxido de carbamida a 37% na percepção dos pacientes em relação à mudança da satisfação com o seu sorriso, e sobre os procedimentos de clareamento e seus resultados de alteração de cor dental e sensibilidade pós-operatória, quando comparado ao peróxido de hidrogênio a 35%. Quarenta pacientes foram alocados para receber duas sessões de clareamento dental de consultório, utilizando peróxido de hidrogênio a 35% (PH) ou peróxido de carbamida a 37% (PC) (n = 20). A percepção do próprio sorriso foi indicada por meio de uma escala visual analógica (EVA), e os procedimentos de clareamento e seus resultados foram avaliados por meio de um questionário aplicado 1 semana após a primeira sessão e 30 dias após a última. O nível de sensibilidade dos pacientes foi registrado durante e até 24 horas após o clareamento. A sensibilidade dentária foi avaliada por meio das escalas verbal e EVA. Foram calculados os riscos absoluto e relativo à sensibilidade. A eficácia dos procedimentos clareadores foi medida com um espectrofotômetro uma semana após cada sessão e 30 dias após a última. Os dados da avaliação da cor (ΔL*, Δa*, Δb* e ΔE) foram individualmente submetidos à ANOVA de 2 fatores para medidas repetidas seguido pelo Teste de comparações múltiplas de Tukey. Os dados sobre o nível da sensibilidade foram analisados pelo teste Mann-Whitney. Riscos absoluto e relativo foram comparados pelo teste Exato de Fisher. Foi observado um menor risco e nível de sensibilidade dentária para o PC, apresentando valores próximos à zero, enquanto que a diferença entre os agentes clareadores desapareceu após 24 horas. Um maior efeito clareador foi observado para o PH, principalmente devido a maior redução do vermelho e amarelo. Os participantes perceberam melhor clareamento dental para o PH e menor sensibilidade para o PC, mas não foram observadas diferenças quanto ao conforto das técnicas. Concluiu-se que o PC resultou em menor sensibilidade dentária, mas também menor eficácia do clareamento dentário. No entanto, ambos os agentes clareadores resultaram em altos níveis de satisfação dos pacientes. / Aracaju
6

Efeito dos agentes clareadores sobre o esmalte dental, a resina composta e a interface dente/restauração / Effect of bleaching agents on the dental enamel, the composite resin and the tooth/restoration interface

Andréa Tami Abe 10 June 2014 (has links)
Este estudo in vitro teve como objetivo avaliar a dureza do esmalte dental, da resina composta, do adesivo e da camada híbrida em esmalte expostos a agentes clareadores à base de peróxido de hidrogênio a 35%, e analisar a interface dente/restauração com microscopia eletrônica de varredura (MEV). Foram utilizadas 40 coroas dentais de incisivos bovinos, que foram incluídas em resina epóxi. Uma cavidade de 2x2x2mm foi confeccionada no terço médio da face vestibular planificada de cada dente. As cavidades foram restauradas com o adesivo Adper Single Bond 2 e a resina nanoparticulada Filtek Z350 XT, e o polimento foi realizado após uma semana da confecção das restaurações. Os corpos de prova foram divididos em quatro grupos (n=10), correspondente a cada agente clareador à base de peróxido de hidrogênio a 35% utilizado (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). A aplicação dos clareadores foi realizada 24 horas após o polimento, de acordo com as recomendações dos respectivos fabricantes. O valor do pH dos agentes clareadores foi medido no início e no final do procedimento clareador. A dureza dos substratos foi mensurada antes (inicial), imediatamente após o clareamento e após 7 dias de armazenamento em saliva artificial com o equipamento ultramicrodurômetro DUH-211S (Shimadzu). As cargas utilizadas foram de 100mN para o esmalte dental e para a resina composta, e de 10mN para o adesivo e para a camada híbrida em esmalte. Para a análise com MEV, foi confeccionado mais um corpo de prova para cada agente clareador, que foi replicado em resina epóxi a cada tempo de análise. Os testes estatísticos empregados foram a ANOVA de 2 fatores sendo 1 com vinculação (p<0,05) e o teste de Tukey. Quanto à dureza do esmalte e da camada híbrida, os corpos de prova expostos aos agentes TB, HPB e HP não apresentaram alteração da dureza nos três tempos de mensuração. O agente PO foi o clareador que apresentou o valor de pH mais baixo e o único que promoveu uma diminuição da dureza desses substratos imediatamente após sua aplicação, porém após 7 dias de armazenamento em saliva artificial a dureza retornou ao valor inicial. Nenhuma alteração foi observada quanto à dureza da resina composta e do adesivo expostos aos agentes clareadores utilizados. A análise em MEV revelou fendas entre o esmalte dental e o adesivo imediatamente após exposição à maioria dos clareadores. Pode-se concluir que o agente PO foi o único que diminuiu a dureza dos substratos dentais e o que promoveu a maior fenda na interface dente/restauração logo após sua aplicação. Nenhum clareador promoveu alteração da dureza da resina composta e do adesivo. / The aim of this in vitro study was to evaluate the hardness of the dental enamel, the composite resin, the dental adhesive and the enamel hybrid layer exposed to 35% hydrogen peroxide bleaching agents, and to analyze the tooth/restoration interface with scanning electron microscopy (SEM). Forty bovine incisor crowns were embedded in epoxy resin and then the labial surface of the teeth was flatted. One 2x2x2mm cavity was prepared on the middle third of each tooth labial surface. The cavities were restored with the adhesive Adper Single Bond 2 and the nanocomposite resin Filtek Z350 XT. After one week of storage, the restorations were polished. The specimens were divided into four groups (n=10), in correspondence to each 35% hydrogen peroxide bleaching agents used (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). The bleaching procedure was performed 24 hours after polish, according to each manufacturer`s recommendation. The pH value of the bleaching agents was measured before and at the end of the bleaching procedure. Hardness test was performed before, immediately after bleaching and after storage in artificial saliva for 7 days, with the ultramicrohardness tester DUH-211S (Shimadzu). Indentations were performed using 100mN load for dental enamel and composite resin, and 10mN load for adhesive layer and enamel hybrid layer. For SEM analysis, one more specimen was made for each bleaching agent, which was replicated in epoxy resin at each measurement time. The statistical tests used were 2-way ANOVA and Tukey test (p<0,05). Regarding to dental enamel and enamel hybrid layer hardness, the specimens exposed to TB, HPB and HP agents did not present hardness alterations at any measurement time. The PO agent presented the lowest pH value and was the only that promoted hardness decrease on these dental surfaces immediately after application, however, after storage in artificial saliva for 7 days the hardness returned to initial value. No alteration was observed regarding to hardness of composite resin and adhesive exposed to bleaching agents. The SEM analysis revealed gaps between the dental enamel and the adhesive immediately after exposure to majority bleaching agents. In conclusion, the PO agent was the only that promoted hardness decrease on dental surfaces, and the major gap formation in tooth/restoration interface after application. No bleaching agents caused any alteration on composite resin and adhesive hardness.

Page generated in 0.1096 seconds