• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uttorkning av komplexa betongkonstruktioner : Uttorkningstider för foggjutning och pågjutning på HD/F / Dehydration of complex concrete structures : Dehydration time for joint grouting and grouting on HD/F

Makdesi Elias, Jamil, Yousif, Filip January 2014 (has links)
Byggandet av dagens sjukhus har blivit allt mer komplext. När det kommer till uppbyggnaden av stomkonstruktionen har kraven för vibrationer ökat. För att säkerställa kraven för stomvibrationer måste pågjutningens tjocklek öka med ca 90 mm från standarden som är ca 40 mm. Att utföra denna extra pågjutning är inte ett problem i sig, utan den extra torktiden som tillkommer. Den extra torktiden är inte det enda problemet. De beräkningsprogram som finns ute på marknaden idag kan inte behandla alla typer av konstruktioner och simuleringar, dock skulle det kunna gå att dela upp simuleringsprocessen för uttorkningen emellan beräkningsprogrammen. I denna studie så kommer två olika simulering/beräknings program att tillämpas. Beräkningsprogrammen som kommer att användas är TORKA S och WUFI. Torktiderna kommer att räknas fram genom att kombinera dessa program samt titta på tidigare studier gällande detta projekt. I denna studie har vi valt att ta en närmare titt på hur foggjutningen mellan håldäcken påverkar torktiden för hela delområdet, dvs. foggjutningen och pågjutningen. Resultaten visar att vct för foggjutningen måste vara betydligt lägre än vct för pågjutningen och att torktiderna varierar beroende på vct. Torktiderna för pågjutningen varierar om mätningar görs över fog eller mitt på håldäcken. / Constructions of hospitals today have become more complex than before. As for the construction of the frame structure, the requirements for vibration in the body have increased. To fulfill the requirements for frame vibrations the top coating thickness must be increased with 90 mm ​​from the standard thickness, which is around 40 mm. To perform this extra topping is not the biggest issue. The major problem is the extra drying time that is added in the process. Another large problem is the calculation programs that are available on the market today cannot deal with all types of designs and simulations; however it would be possible to divide the simulation process for the dehydration between different calculation programs. In this study, two different simulation/calculation programs will be used. The programs that will be applied are TorkaS 3.2 and WUFI Pro. Drying times will be generated by combining these programs and look at previous studies similar to this project. In this study we have chosen to take a closer look at how joint cast between the slabs affects the drying time for the entire sub-area, which is the joint cast and topping cast. The results of the w/c-ratio for joint cast must be significantly lower than w/c-ratio for topping and that drying times will vary depending on the w/c-ratio. Drying times for topping will also vary if measurements are made over the joint or middle of the slab.
2

En utvärdering av ett nyutvecklat betongbjälklag för fler bostadshus / An evaluation of a newly developed concrete floor for apartment buildings

Ali, Hussam Jader, Manta, Teofil January 2014 (has links)
Utvecklingen av framtidens flerbostadshus ställer höga krav på en bjälklagslösnings tekniska egenskaper. Plattbärlagsbjälklaget som idag utgör det vanligaste förekommande bjälklagsvalet vid uppförandet av flerbostadshus kan ses som en lösning som kombinerar en god bärförmåga med stora möjligheter ur teknisk synpunkt. Målet med denna undersökning har varit att jämföra det traditionella plattbärlaget med en nyutvecklad bjälklagslösning baserad på produkten förspänt håldäcksbjälklag (HD/F). Jämförelsen har utgått från de aktuella kraven som enligt Boverkets byggregler (BBR) idag ställs på bjälklag och fokuserat på aspekter ur ljud, brand och fuktsynpunkt. Dessutom har jämförelsen beaktat de maximala spännvidder som respektive lösning kan dimensioneras för. Resultatet av de genomförda undersökningarna visade på att den nyutvecklade bjälklagslösningen är tillräckligt konkurrenskraftig för att i framtiden få ett större användande inom flerbostadshus. Medan plattbärlagets fördelar utmärker sig ur ljudsynpunkt möjliggör dock användandet av den nyutvecklade lösningen längre spännvidder och kortare torktider. / The development of apartment buildings puts high demands on the technical characteristics of floor systems. The lattice girder system which today represents the most commonly utilized floor system when building apartment buildings, is characterized by a good load-bearing ability along with great opportunities from a technical point of view. The aim of this analysis was to compare the traditional lattice girder system with a newly developed floor system based on hollow core slabs. The comparison is based on the current technical requirements set by Boverkets byggregler (BBR) and has its main focus on subjects related to sound, fire and moisture matters. The comparison has also accounted for the maximum spans which can be used for each solution respectively. The results of the investigation show that the newly developed floor system is competitive enough to be used in future apartment buildings. While the advantages of the lattice girder system are distinctive from a sound point of view, the utilization of the newly developed floor solution enables longer spans and shorter curing time.

Page generated in 0.3719 seconds