• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • Tagged with
  • 6
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ultra-pure digital detection of polarization for radio astronomy applications

Alvear Cabezón, Andrés Arturo January 2018 (has links)
Magíster en Ciencias de la Ingeniería, Mención Ingeniería Eléctrica / Polarization is a key measurement within radio astronomy because its state can give insight as to the physical conditions of the source and the medium the radiation has traveled through. In radio astronomy receivers, the device used to separate the polarization is known as an Ortho-Mode Transducer (OMT). The OMT is a passive component that separates signals into two orthogonal components. Using available millimeter-wave analog technology, wideband heterodyne receiver systems generally obtain polarization isolation ratios of 15dB to 20dB, insufficient for modern astronomical applications. That low polarization isolation ratio is due to the presence of leakage from one polarization contaminating the other, which is known as cross-polarization. In order to improve polarization isolation and reduce cross-polarization, a new approach called Digital OMT has been proposed, based on passing one given functionality from the analog domain to the digital domain using digital signal processing techniques. Digital techniques were studied to improve OMT performance, which led to the design of a polarimeter based on the Fast Fourier Transform (FFT). The polarimeter was implemented on a Field Programmable Gate Array (FPGA), including the implementation of a Ku-band analog front-end to characterize the design and measure the synthesized polarization. This thesis introduces a prototype of a DOMT created for real-time processing and continuous integration, suitable for radio astronomy observations. The configuration used is based on the architecture of a compact four-port OMT. The outputs are downconverted using mixers and then directly digitalized using four 8bit ADC sampling at 1.2 GSPS. A 180° hybrid was implemented on the FPGA together with a set of calibration vectors, with the purpose of compensating the amplitude and phase imbalance typical of analog radio astronomy front-ends. This calibrated Digital OMT exhibits a polarization isolation ratio of more than 40 dB for the entire RF bandwidth, representing an improvement factor of 100 over its analog counterpart. / Este trabajo ha sido parcialmente financiado por Centro de Astrofísica y Tecnologías Afines (CATA-BASAL-PBF 06), FONDECYT 11140428 y 1121051, y ALMA-CONICYT 31150012. Agradecemos a Xilinx Inc. por la donación de circuitos integrados y licencias de software y a la comunidad de CASPER por el apoyo brindado.
2

Análise dos procedimentos de medida de dispositivos EGFET utilizando filmes de FTO / Analysis of measurement procedures of EGFET devices using FTO films

Nascimento, Raphael Aparecido Sanches 26 November 2010 (has links)
Ao longo dos anos a medicina vem se desenvolvendo rapidamente e junto com ela desenvolvem-se os métodos e processos de diagnósticos. Estes métodos ficam mais rápidos, precisos e cada vez menos invasivos graças ao desenvolvimento de dispositivos diagnósticos a cada dia menores e que produzam respostas confiáveis. Os biossensores são, sem dúvida, os grandes responsáveis pela miniaturização, barateamento e rapidez de diversos métodos diagnósticos e procedimentos clínicos utilizados diariamente. Dentre os diferentes tipos de biossensores existentes, destacamos os biossensores embasados em transistores de efeito de campo (FETs), mais precisamente os biossensores a base de transistor de efeito de campo de porta estendida (EGFET). Analisamos nesse trabalho os procedimentos de medida utilizando filmes finos de óxido de estanho dopados com flúor (FTO) como membrana sensível a íons H+ acoplados à porta de um EGFET, que podem servir de base para a construção de um biossensor no futuro. Já existem artigos na literatura atual que fazem uso de FTO como membrana sensível a íons H+ e OH-. Entretanto, nenhum dos artigos disponíveis faz um bom controle de alguns parâmetros, em alguns casos relativamente simples, ou se fazem não deixam claro de que maneira estão controlando esses parâmetros. Tais parâmetros são de fundamental importância na resposta final dos sensores uma vez que eles interferem significativamente no sinal dos mesmos. Mostramos no presente trabalho que parâmetros como a luz, a sequência em que os pHs são medidos pela amostra, o procedimento de limpeza das amostras e até as características morfológicas das amostras são importantes no processo de adsorção e retirada de íons da superfície da membrana. Mostramos também que cada amostra necessita uma rotina diferente quanto à sequência de medidas e até mesmo procedimentos de limpeza para que seu rendimento seja máximo, e como diferentes amostras evoluem ao longo do tempo. Como solução aos problemas citados, descrevemos o uso correto de duas amostras que apresentaram reprodutibilidade em seus dados e invariância entre os resultados coletados por diferentes sequências de medidas. Por fim, deixamos uma proposta sobre a dinâmica que ocorre durante os processos de adsorção e retirada de íons H+ e OH- na superfície dos filmes. Com base em nossa proposta fizemos cálculos teóricos estimados da quantidade de cargas que são adsorvidas na superfície do filme para as diferentes situações encontradas durante os experimentos. / Over the years the medicine has been developing rapidly and along with it develop methods and diagnostic procedures. These methods become faster, more accurate and less invasive thanks to the development of diagnostic devices each day minors and producing reliable answers. The biosensors are undoubtedly the major responsible for miniaturization, cheaper and rapidity of various diagnostic methods and clinical procedures used every day. Among the different types of existing biosensors, we highlight the biosensors grounded in field effect transistors (FETs), more precisely the biosensor based in extended gate field effect transistor (EGFET). We analyzed on this work measurement procedures using tin oxide thin films doped with fluorine (or fluorine tin oxide FTO) as sensitive the membrane to H+ ions bounded to the gate of an EGFET, which can serve as a basis for building a biosensor in the future. Articles has already been written reporting the use of the FTO as sensitive membrane to ion H+ and OH-. However, none article available makes a good control of some parameters, in some cases relatively simple, or if they do not make it clear the way they are controlling these parameters. These parameters are of crucial importance in the final response of the sensors since they interfere significantly in signal of the sensors. So, we shown in this work, which parameters as light, the sequence in which the pHs are measured by the sample, the cleaning procedure of samples and even the morphological characteristics of the samples are important in the process of adsorption and ion withdrawal of membrane surface. We shown also that each sample requires a different routine on the following measures and even cleaning procedures for your maximum income is, and how different samples evolve over time. As a solution to the problems cited, we describe the correct use of two samples that showed reproducibility in your data and invariance between the results collected by different sequences of measures. Finally, we leave a proposal on the dynamics that occurs during adsorption processes and withdrawal ion H+ and OH- on the surface of the films. Based on our proposal did theoretical calculations estimated quantity of loads that are adsorb on the surface of the film for the different situations encountered during experiments.
3

Análise dos procedimentos de medida de dispositivos EGFET utilizando filmes de FTO / Analysis of measurement procedures of EGFET devices using FTO films

Raphael Aparecido Sanches Nascimento 26 November 2010 (has links)
Ao longo dos anos a medicina vem se desenvolvendo rapidamente e junto com ela desenvolvem-se os métodos e processos de diagnósticos. Estes métodos ficam mais rápidos, precisos e cada vez menos invasivos graças ao desenvolvimento de dispositivos diagnósticos a cada dia menores e que produzam respostas confiáveis. Os biossensores são, sem dúvida, os grandes responsáveis pela miniaturização, barateamento e rapidez de diversos métodos diagnósticos e procedimentos clínicos utilizados diariamente. Dentre os diferentes tipos de biossensores existentes, destacamos os biossensores embasados em transistores de efeito de campo (FETs), mais precisamente os biossensores a base de transistor de efeito de campo de porta estendida (EGFET). Analisamos nesse trabalho os procedimentos de medida utilizando filmes finos de óxido de estanho dopados com flúor (FTO) como membrana sensível a íons H+ acoplados à porta de um EGFET, que podem servir de base para a construção de um biossensor no futuro. Já existem artigos na literatura atual que fazem uso de FTO como membrana sensível a íons H+ e OH-. Entretanto, nenhum dos artigos disponíveis faz um bom controle de alguns parâmetros, em alguns casos relativamente simples, ou se fazem não deixam claro de que maneira estão controlando esses parâmetros. Tais parâmetros são de fundamental importância na resposta final dos sensores uma vez que eles interferem significativamente no sinal dos mesmos. Mostramos no presente trabalho que parâmetros como a luz, a sequência em que os pHs são medidos pela amostra, o procedimento de limpeza das amostras e até as características morfológicas das amostras são importantes no processo de adsorção e retirada de íons da superfície da membrana. Mostramos também que cada amostra necessita uma rotina diferente quanto à sequência de medidas e até mesmo procedimentos de limpeza para que seu rendimento seja máximo, e como diferentes amostras evoluem ao longo do tempo. Como solução aos problemas citados, descrevemos o uso correto de duas amostras que apresentaram reprodutibilidade em seus dados e invariância entre os resultados coletados por diferentes sequências de medidas. Por fim, deixamos uma proposta sobre a dinâmica que ocorre durante os processos de adsorção e retirada de íons H+ e OH- na superfície dos filmes. Com base em nossa proposta fizemos cálculos teóricos estimados da quantidade de cargas que são adsorvidas na superfície do filme para as diferentes situações encontradas durante os experimentos. / Over the years the medicine has been developing rapidly and along with it develop methods and diagnostic procedures. These methods become faster, more accurate and less invasive thanks to the development of diagnostic devices each day minors and producing reliable answers. The biosensors are undoubtedly the major responsible for miniaturization, cheaper and rapidity of various diagnostic methods and clinical procedures used every day. Among the different types of existing biosensors, we highlight the biosensors grounded in field effect transistors (FETs), more precisely the biosensor based in extended gate field effect transistor (EGFET). We analyzed on this work measurement procedures using tin oxide thin films doped with fluorine (or fluorine tin oxide FTO) as sensitive the membrane to H+ ions bounded to the gate of an EGFET, which can serve as a basis for building a biosensor in the future. Articles has already been written reporting the use of the FTO as sensitive membrane to ion H+ and OH-. However, none article available makes a good control of some parameters, in some cases relatively simple, or if they do not make it clear the way they are controlling these parameters. These parameters are of crucial importance in the final response of the sensors since they interfere significantly in signal of the sensors. So, we shown in this work, which parameters as light, the sequence in which the pHs are measured by the sample, the cleaning procedure of samples and even the morphological characteristics of the samples are important in the process of adsorption and ion withdrawal of membrane surface. We shown also that each sample requires a different routine on the following measures and even cleaning procedures for your maximum income is, and how different samples evolve over time. As a solution to the problems cited, we describe the correct use of two samples that showed reproducibility in your data and invariance between the results collected by different sequences of measures. Finally, we leave a proposal on the dynamics that occurs during adsorption processes and withdrawal ion H+ and OH- on the surface of the films. Based on our proposal did theoretical calculations estimated quantity of loads that are adsorb on the surface of the film for the different situations encountered during experiments.
4

Sensor de pressão microeletromecânico com fonte de referência em tensão / Microelectronic pressure sensor with voltage reference

Camolesi, Alessandro 08 June 2010 (has links)
Orientador: Fabiano Fruett / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-16T19:24:36Z (GMT). No. of bitstreams: 1 Camolesi_Alessandro_M.pdf: 2180894 bytes, checksum: c85cabaf810d1a57424f169a1f9b2f85 (MD5) Previous issue date: 2010 / Resumo: Apresentamos neste trabalho a fabricação e a caracterização de um sensor de pressão totalmente compatível com a tecnologia CMOS. Este sensor é constituído por quatro piezoresistores, implantados e dispostos em ponte de Wheatstone. Os processos de fabricação do sensor foram todos realizados no Centro de Componentes e Semicondutores (CCS) - Unicamp. A membrana do sensor foi obtida através de um processo de desbaste mecânico do die que foi colado em uma placa de alumina. O alinhamento da colagem foi baseado em um orifício central. O sensor encapsulado apresentou sensibilidade de 0.32mV/psi. Além disso, projetamos uma fonte de referência em tensão do tipo Bandgap. Nesta fonte de referência usamos uma técnica para minimizar os gradientes de estresse mecânico, a maior fonte de não-idealidade desta fonte de referência e permitiu estudarmos a deriva térmica da sensibilidade da ponte / Abstract: We presented in this work the fabrication and the characterization of a pressure sensor totally CMOS compatible. This sensor is arranged by four p-type silicon piezoresistive implanted in a Wheatstone bridge. The fabrication processes were all performed at the Center for Components and Semiconductors (CCS) - Unicamp. The membrane was obtained by a mechanical polishing process of the die that was attached by RTV (Room Temperature Vulcanization) on an alumina substrate. The attach alignment was based on the center of the vent hole. The packaged sensor showed a sensitivity amounts to 0.32mV/psi. Also, a Bandgap voltage reference was designed. In such voltage reference uses a technical to minimize gradients such as mechanical stress, the main non-ideality source to such voltage reference and it allowed the drift thermal analysis of the bridge sensitivity / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
5

Acoustic System Development for Neutrino Underwater Detectors

Saldaña Coscollar, María 31 July 2017 (has links)
The main objective of this research is the design and development of two different underwater acoustic emitters aimed to the deep-sea KM3NeT neutrino telescope, more specifically for the Acoustic Positioning System (APS) and for the calibration of the acoustic neutrino detection technique. The KM3NeT project is a new optical-based deep-sea neutrino telescope, currently under construction. The main objectives of the KM3NeT telescope are the discovery and observation of high-energy neutrino sources in the Universe and the determination of the mass hierarchy of neutrinos. The KM3NeT detectors consist of three-dimensional arrays of light sensor modules distributed over large volumes of the transparent water in the deep Mediterranean Sea. The sensor modules register the time of arrival of the light and the brightness of the light to reconstruct the direction and energy of the neutrino. In order to achieve an accurate deployment of the mechanical structures and a precise reconstruction of neutrino induced events, the telescope includes an APS as mandatory sub-system that provides an accurate position of the mechanical structures in real time. Additionally, the APS could also be an excellent tool to study the feasibility of an acoustic neutrino detector and a possible correlation between acoustic and optical signals. The new detector KM3NeT is an excellent opportunity to continue with the study of the acoustic neutrino detection. The acoustic detection would allow the combination of the two neutrino detection techniques for a hybrid underwater neutrino telescope, especially considering that the optical based telescope needs acoustic sensors to monitor the position of the sensors. An Acoustic Beacon (AB) as part of the APS of KM3NeT has been developed in this thesis. Previously, the first emitter prototype was developed and it was installed in previous neutrino telescopes, such as ANTARES and NEMO, in order to be tested in situ. The analyses of the in situ test with the prototypes were performed as part of this thesis. The results obtained from the tests showed that the requirements for the positioning system are accomplished, just needing few improvements for the final version. The final version of the AB is composed by a piezo-ceramic transducer and an electronic board integrated in a single piece in a cylindrical hard-anodized aluminium vessel. The design and the work done for a precise laboratory test was performed achieving optimal results in all aspects As second main work performed in this thesis, a parametric transducer array able to mimic the acoustic signal generated by Ultra-High Energy (UHE) neutrino interaction in water was designed and developed. The first part was designing a single transducer able to emit parametrically the acoustic neutrino signal. Afterwards, the design of the complete array system composed of few units was performed in order to achieve a more energetic and directional bipolar pulse. / El objetivo principal de esta investigación es el diseño y desarrollo de dos tipos de emisores acústicos diferentes para ser utilizados en el telescopio submarino de neutrinos KM3NeT, en concreto, uno como emisor en el sistema de posicionamiento acústico (APS) y otro para la calibración de la detección acústica de neutrinos. El proyecto KM3NeT es un telescopio óptico de neutrinos, que actualmente está en fase de construcción, y está ubicado en las profundidades del mar. Los objetivos principales del telescopio son el descubrimiento y la observación de las fuentes que originan los neutrinos de alta energía en el universo y la determinación de la jerarquía de masas de los neutrinos. Los detectores de KM3NeT consisten en conjuntos tridimensionales de módulos de sensores de luz distribuidos en grandes volúmenes de agua en las profundidades del mar Mediterráneo. Los módulos de sensores ópticos registran el tiempo de llegada de la luz y el brillo de la luz para reconstruir la dirección y la energía del neutrino. Con objeto de lograr una implementación correcta de las estructuras mecánicas y una reconstrucción precisa de los eventos del neutrino, el telescopio incluye el APS como subsistema necesario para proporcionar la posición exacta de las estructuras mecánicas en tiempo real. Además, el APS puede ser una herramienta excelente para estudiar la viabilidad de un detector de neutrinos acústico y de una posible correlación entre la señal acústica y óptica. El nuevo detector KM3NeT es una oportunidad para continuar con el estudio de detección acústica de neutrinos. La detección acústica permitiría la combinación de las dos técnicas de detección de neutrinos para un telescopio submarino de neutrinos híbrido, y más aún, teniendo en cuenta que el telescopio óptico necesita de sensores acústicos para monitorizar la posición de los sensores. En esta tesis, por un lado, se ha desarrollado un emisor acústico (AB) como parte del APS de KM3NeT. Previamente, se desarrolló el primer prototipo del emisor acústico, el cual se instaló en anteriores telescopios de neutrinos, concretamente en ANTARES y NEMO, con el fin de comprobar su funcionamiento in situ. Como parte de la tesis, se realizaron los análisis de las pruebas in situ y los resultados obtenidos mostraron que cumplía los requisitos del sistema de posicionamiento, únicamente se necesitaron algunas mejoras para la versión final. La versión final del AB está compuesta por un transductor piezo-cerámico y una placa electrónica integrado en una sola pieza en un recipiente cilíndrico de aluminio anodizado. El diseño y el trabajo realizado para una calibración precisa de laboratorio se llevó a cabo, logrando resultados óptimos en todos los aspectos requeridos. El segundo trabajo principal desarrollado en esta tesis consistió en el diseño de un array paramétrico de transductores capaz de imitar la señal acústica generada por la interacción del neutrino de ultra-alta energía (UHE) en el agua. La primera parte de su diseño se centró en el desarrollo de un transductor individual capaz de emitir paramétricamente la señal acústica del neutrino. Posteriormente, se realizó el diseño del array completo compuesto por varias unidades del transductor diseñado, con el objeto de lograr un pulso bipolar más enérgico y directivo. / L'objectiu principal d'esta investigació és el disseny i desenvolupament de dos tipus d'emissors acústics diferents per a ser utilitzats en el telescopi submarí de neutrins KM3NET, en concret, ú com emissor en el sistema de posicionament acústic (APS) i altre per a la calibració de la detecció acústica de neutrins. El projecte KM3NET és un telescopi òptic de neutrins, que actualment està en fase de construcció, i està ubicat en les profunditats del mar. Els objectius principals del telescopi són el descobriment i l'observació de les fonts que originen els neutrins d'alta energia en l'univers i la determinació de la jerarquia de masses dels neutrins. Els detectors de KM3NET consisteixen en conjunts tridimensionals de mòduls de sensors de llum distribuïts en gran volums d'aigua en el Mediterrani. Els mòduls de sensors òptics registren el temps d'aplegada de la llum i la intensitat de la llum per a reconstruir la direcció i l'energia del neutrí. Com objectiu d'aconseguir una implementació correcta de les estructures mecàniques i una reconstrucció precisa dels events del neutrí, el telescopi inclou l'APS com subsistema necessari per a proporcionar la posició exacta de les estructures mecàniques en temps real. A mes, l'APS pot ser una ferramenta excel¿lent per a estudiar la viabilitat d'un detector de neutrins acústic i d'una possible correlació entre el senyal acústic i òptic. El nou detector KM3NET és una oportunitat per a continuar en l'estudi de detecció acústica del neutrí. La detecció acústica permetria la combinació de les dos tècniques de detecció de neutrins per a un telescopi submarí de neutrins híbrid, i més encara, tenint en compte que el telescopi òptic necessita de sensors acústics per a monitoritzar la posició dels sensors. En aquesta tesis, per un costat, s'ha dissenyat un emissor acústic (AB) com part de l'APS de KM3NET. Prèviament, se desenvolupà el primer prototip de l'emissor acústic, el qual s'instal¿là en anteriors telescopis de neutrins, concretament en ANTARES i NEMO, amb el fi de comprovar-se el seu funcionament in situ. Com part de la tesis, es realitzaren els anàlisis de les proves in situ i els resultats obtinguts mostraren que complia els requisits del sistema de posicionament, únicament necessitant-se d'algunes millores per a la versió final. La versió final de l'AB està composta per un transductor piezo-ceràmic i una placa electrònica integrats en una sola peça en un recipient cilíndric d'alumini anoditzat. El disseny i el treball realitzat per a una calibració precisa de laboratori es va dur a terme, aconseguint resultats òptims en tots els aspectes requerits. Com segon treball principal desenvolupat en esta tesis, s'ha dissenyat un array paramètric de transductors capaç d'imitar el senyal acústic generat per l'interacció del neutrí d'ultra-alta energia (UHE) en l'aigua. La primera part de disseny es centrà en el desenvolupament d'un transductor individual capaç d'emetre paramètricament el senyal acústic del neutrí. Posteriorment, es va realitzar el disseny de l'array complet compost per varies unitats del transductor dissenyat, amb l'objectiu d'aconseguir un pols bipolar més energètic i directiu. / Saldaña Coscollar, M. (2017). Acoustic System Development for Neutrino Underwater Detectors [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/85981 / TESIS
6

Development and Optimization of Experimental Biosensing Protocols Using Porous Optical Transducers

Martínez Pérez, Paula 02 September 2021 (has links)
[ES] Los biosensores son dispositivos analíticos con aplicabilidad en diferentes campos y con numerosas ventajas frente a otros métodos analíticos convencionales, como son el uso de pequeños volúmenes de muestra y reactivos, su sensibilidad y su rápida respuesta, sin necesidad de pretratamiento de la muestra, equipos caros o personal especializado. Sin embargo, se trata de un campo de investigación relativamente nuevo en el que todavía queda mucho camino por andar. Esta Tesis doctoral pretende aportar un granito de arena a este campo de conocimiento mediante el estudio del potencial de diferentes materiales porosos como transductores para el desarrollo de biosensores ópticos con respuesta en tiempo real y sin marcajes. Los materiales propuestos van desde aquellos artificialmente sintetizados, como silicio poroso (SiP), nanofibras (NFs) poliméricas o membranas poliméricas comerciales, hasta materiales naturales con propiedades fotónicas que todavía no habían sido explotadas para el sensado, como son los exoesqueletos de biosílice de diatomeas. Todos ellos tienen en común la simplicidad en su obtención, evitando costosos y laboriosos procesos de nanofabricación. Para su estudio, se analizará su respuesta óptica y, en aquellos casos en los que ésta permita llevar a cabo experimentos de detección, se desarrollarán estrategias para su biofuncionalización y su implementación en experimentos de biosensado. En el caso del SiP y las NFs se han optimizado los parámetros de fabricación para obtener una respuesta óptica adecuada que permita su interrogación. A continuación, se ha llevado a cabo su biofuncionalización empleando métodos covalentes y no covalentes, así como diferentes bioreceptores (aptámeros de ADN y anticuerpos) para estudiar su potencial y sus limitaciones como biosensores. En el caso de las membranas comerciales y el exoesqueleto de sílice de diatomeas, se ha caracterizado su respuesta óptica y se han llevado a cabo experimentos de sensado de índice de refracción para estudiar su sensibilidad. Así mismo, se ha desarrollado un método de funcionalización de la superficie del exoesqueleto de diatomeas basado en el uso de polielectrolitos catiónicos. Como resultado, se ha demostrado el potencial tanto de NFs para el desarrollo de biosensores, como el de membranas comerciales para sensores cuya aplicación no requiera una elevada sensibilidad pero sí un bajo coste. Además, se ha puesto de manifiesto el gran potencial del exoesqueleto de diatomeas para el desarrollo de sensores basados en su respuesta óptica. Por el contrario, las limitaciones encontradas en el desarrollo de biosensores basados en SiP han evidenciado la necesidad de un estudio riguroso y la optimización de la estructura de materiales porosos previamente a ser usados en (bio)sensado. / [CA] Els biosensors són dispositius analítics amb aplicabilitat en diferents camps i amb nombrosos avantatges enfront d'altres mètodes analítics convencionals, com són l'ús de xicotets volums de mostra i reactius, la seua sensibilitat i la seua ràpida resposta, sense necessitat de pretractament de la mostra, equips cars o personal especialitzat. No obstant això, es tracta d'un camp d'investigació relativament nou en el qual encara queda molt camí per fer. Aquesta Tesi doctoral pretén aportar el seu òbol a aquest camp de coneixement mitjançant l'estudi del potencial de diferents materials porosos com a transductors per al desenvolupament de biosensors òptics amb resposta en temps real i sense marcatges. Els materials proposats van des d'aquells artificialment sintetitzats, com a silici porós (SiP), nanofibras (NFs) polimèriques o membranes polimèriques comercials, fins a materials naturals amb propietats fotòniques que encara no havien sigut explotades per al sensat, com són els exoesquelets de biosílice de diatomees. Tots ells tenen en comú la simplicitat en la seua obtenció, evitant costosos i laboriosos processos de nanofabricació. Per al seu estudi, s'analitzarà la seua resposta òptica i, en aquells casos en els quals aquesta permeta dur a terme experiments de detecció, es desenvoluparan estratègies per a la seua biofuncionalizació i la seua implementació en experiments de biosensat. En el cas del SiP i les NFs s'han optimitzat els paràmetres de fabricació per a obtenir una resposta òptica adequada que permeta la seua interrogació. A continuació, s'ha dut a terme la seua biofuncionalizació emprant mètodes covalents i no covalents, així com diferents bioreceptors (aptàmers d'ADN i anticossos) per a estudiar el seu potencial i les seues limitacions com a biosensors. En el cas de les membranes comercials i l'exoesquelet de sílice de diatomees, s'ha caracteritzat la seua resposta òptica i s'han dut a terme experiments de sensat d'índex de refracció per a estudiar la seua sensibilitat. Així mateix, s'ha desenvolupat un mètode de funcionalizació de la superfície de l'exoesquelet de diatomees basat en l'ús de polielectròlits catiònics. Com a resultat, s'ha demostrat el potencial tant de NFs per al desenvolupament de biosensors, com el de membranes comercials per a sensors amb una aplicació que no requerisca una elevada sensibilitat però sí un baix cost. A més, s'ha posat de manifest el gran potencial de l'exoesquelet de diatomees per al desenvolupament de sensors basats en la seua resposta òptica. Per contra, les limitacions trobades en el desenvolupament de biosensors basats en SiP han evidenciat la necessitat d'un estudi rigorós i l'optimització de l'estructura dels materials porosos prèviament a ser usats en (bio)sensat. / [EN] Biosensors are analytical devices with application in diverse fields and with several advantages relative to other conventional methods, such as the use of small volumes of sample and reagents, their sensitivity and their fast response, without the need of the sample pretreatment, expensive equipments or specialised technicians. Nevertheless, this is a relatively new research field in which there is a long way to go yet. This doctoral Thesis aims at doing its bit to this field of knowledge by studying the potential of different porous materials as transducers for the development of real-time and label-free optical biosensors. The proposed materials range from those artificially synthesised, such as porous silicon (pSi), polymeric nanofibres (NFs) or commercial polymeric membranes, to natural materials with photonic properties that had not been exploited for sensing yet, such as biosilica exoskeletons of diatoms. All of them have in common its simple production, avoiding expensive and laborious nanofabrication processes. For their study, their optical response will be analysed and, in those cases in which such optical response allows performing detection experiments, strategies for their biofunctionalisation and their implementation in biosensing experiments will be developed as well. Regarding pSi and NFs, the fabrication parameters were optimised to get a suitable optical response for their interrogation. Afterwards, their surface functionalisation was carried out by covalent and non-covalent methods, as well as different bioreceptors (DNA aptamers and antibodies), to study their potential and their constraints as biosensors. Concerning commercial membranes and the biosilica exoskeleton of diatoms, their optical response was characterised and refractive index sensing experiments were carried out to study their sensitivity. Additionally, a biofunctionalisation method for the surface of the diatoms exoskeleton was developed based on the use of cationic polyelectrolytes. As a result, it was demonstrated the potential of NFs for the development of biosensors, as well as the potential of commercial membranes for developing sensors for an application that does not require a high sensitivity but a low cost. Furthermore, the great potential of biosilica exoskeleton of diatoms for the development of sensors based on their optical response has been revealed. By contrast, the constraints found in the development of pSi illustrate the importance of an accurate study and optimisation of porous materials structure before using them for (bio)sensing. / Martínez Pérez, P. (2021). Development and Optimization of Experimental Biosensing Protocols Using Porous Optical Transducers [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/172541 / TESIS

Page generated in 0.4276 seconds