• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2054
  • 46
  • 44
  • 41
  • 41
  • 38
  • 23
  • 21
  • 17
  • 16
  • 16
  • 15
  • 4
  • 2
  • 1
  • Tagged with
  • 2159
  • 940
  • 451
  • 399
  • 370
  • 352
  • 256
  • 239
  • 237
  • 200
  • 189
  • 181
  • 179
  • 166
  • 150
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Análise do comportamento de uma linha de um pouco mais de meio comprimento de onda sob diferentes condições de operação em regime permanente e durante a manobra de energização / Analysis of the behavior of an isolated transmission line with a little more than half wave lenght for different operating conditions in steady state and during the energization manouver

Vidigal, Rodrigo Fernandes 16 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-16T22:19:27Z (GMT). No. of bitstreams: 1 Vidigal_RodrigoFernandes_M.pdf: 3000237 bytes, checksum: 232f1475b91d13386621a654c4a17690 (MD5) Previous issue date: 2010 / Resumo: Este trabalho apresenta uma análise do comportamento de uma linha de transmissão isolada de um pouco mais de meio comprimento de onda (2600 km) na freqüência fundamental, 60 Hz, alimentada a partir de uma barra infinita para diferentes condições de operação. Os perfis de tensão e de corrente, para diferentes condições de carregamento, são monitorados ao longo da linha. Uma análise do fator de potência da potência injetada no terminal emissor também é realizada e sua influência nos perfis de tensão e de corrente é verificada. As perdas ao longo da linha para diferentes níveis de potência transmitida são medidas e uma alternativa para minimização dessas perdas é apresentada. Uma metodologia de análise sistemática na freqüência fundamental de um sistema elétrico de potência identificando as condições críticas é também apresentada. A presente metodologia é aplicada em um sistema formado por linhas de transmissão de 500 kV existentes no sistema elétrico brasileiro, as quais são interligadas formando um tronco de 2600 km com a finalidade de representar uma linha de transmissão de um pouco mais de meio comprimento de onda. As análises feitas nesse trabalho consistem na verificação do comportamento do sistema na presença de diferentes tipos de curtos-circuitos em diferentes pontos da linha. Após a análise sistemática em regime permanente, as condições extremas podem ser simuladas em um programa de transitórios eletromagnéticos. Deste modo o comportamento da linha isolada alimentada a partir de uma barra infinita na presença de diferentes tipos de curtos-circuitos é discutido e os principais resultados são apresentados nesse trabalho. O tronco de 2600 km formado por linhas de 500 kV existentes no Brasil foi utilizado para simular a manobra de energização. As simulações incluíram diferentes técnicas de energização como o fechamento direto das fases, a utilização de um resistor de pré-inserção e o chaveamento controlado. Para cada alternativa de chaveamento foram analisadas as sobretensões transitórias e o perfil de tensão ao longo da linha. As simulações foram feitas utilizando-se os softwares ATP e PSCAD/EMTDC / Abstract: This work presents an analysis of the behavior of an isolated transmission line with a little more than half-wave length (2600 km) on fundamental frequency, 60 Hz, connected to an infinite busbar for different operating conditions. The voltage and current profiles for different loading conditions are monitored along the line. An analysis of the influence of the power factor of the transmitted energy on the voltage and current profiles along the line is performed. The losses along the line for different levels of transmitted power are measured and a method to minimize these losses is presented. A systematic review methodology in the fundamental frequency of a power system identifying the critical conditions is also presented. This methodology is applied to a system formed by 500 kV existing transmission lines in the Brazilian electrical system, which are interconnected forming an AC-link of 2600 km in order to represent a transmission line of a little more than half-wave length. The analysis made in this paper means to verify the system behavior in the presence of different types of short circuits at different points along the line. After systematic analysis in steady state, the extreme conditions can be simulated in an electromagnetic transient program. Thus the behavior of the isolated line connected to an infinite busbar in the presence of different types of short circuits is discussed and the main results are presented in this paper. The 2600 km AC-link formed by actual Brazilian 500 kV lines was used to simulate the trunk energization. The simulations included different techniques such as direct closure energization, the use of a pre-insertion resistor and the controlled switching. For each alternative it was analyzed the transient overvoltage profile along the line. The simulations were done with the software ATP and PSCAD / EMTDC / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
102

Absorção com reação quimica em processos de borbulhamento : casos isotermico e não-isotermico

Stragevitch, Andrea Selene Embirassu Xavier 28 August 1996 (has links)
Orientador: Alberto Luiz de Andrade / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-21T14:43:17Z (GMT). No. of bitstreams: 1 Stragevitch_AndreaSeleneEmbirassuXavier_D.pdf: 6888881 bytes, checksum: ebe72e49c23b48d9aa3e9815a9e45580 (MD5) Previous issue date: 1996 / Resumo: Um modelo matemático é apresentado para predizer a velocidade de transferência de massa de um componente num processo de absorção, através de borbulhamento. O problema da absorção gasosa, acompanhada por uma reação instantânea e reversível, foi estudado para as condições isotérmicas e não-isotérmicas. A análise realizada proporcionou a determinação dos coeficientes de transferência de massa e de calor, externo e interno à bolha, a qual se encontra em movimento ascendente. Neste caso, o presente trabalho considerou o gás no interior da bolha como sendo estagnado, ou seja, o mecanismo interno é difusivo. A descrição do coeficiente de transferência de massa da fase líquida foi baseada em termos do modelo de filme. Um processo não-isotérmico foi estudado para se obter a influência dos efeitos térmicos sobre a taxa de transferência de massa. O aumento da temperatura na interface gás-líquido e o fator de aumento para uma taxa de absorção gasosa não-isotérmica, foram analisados. O efeito da volatilidade do reagente líquido sobre a taxa de absorção foi considerado. Os resultados teóricos, provenientes de um processo em condições isotérmicas, foram comparados com um processo não-isotérmico. Uma montagem experimental foi desenvolvida para estudar a transferência de massa e de calor do 'SO IND. 2¿ de uma mistura gasosa para uma fase contínua, constituída de água pura. Os resultados obtidos a partir da modelagem matemática utilizada, apresentaram uma concordância satisfatória quando comparados aos resultados experimentais / Abstract: Not informed. / Doutorado / Sistemas de Processos Quimicos e Informatica / Doutor em Engenharia Química
103

Planejamento a longo prazo de sistemas de transmissão tecnicas de otimização combinatorial

Gallego Rendon, Ramon Alfonso 08 October 1997 (has links)
Orientadores: Alcir Jose Monticelli, Ruben Augusto Romero Lazaro / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-22T20:50:03Z (GMT). No. of bitstreams: 1 GallegoRendon_RamonAlfonso_D.pdf: 17876427 bytes, checksum: 3820f9cecad99848cb4c9d5127a87b2d (MD5) Previous issue date: 1997 / Resumo: Este trabalho apresenta várias metodologias para resolver o problema de planejamento da expansão a longo prazo de sistemas de transmissão. Após observar os resultados pouco consistentes obtidos com os algoritmos heurísticos construtivos, especialmente quando foram usados na solução de sistemas de grande porte, e os resultados obtidos com os métodos de otimização usando a decomposição de Benders (os quais encontram as soluções ótimas para sistemas de pequeno e médio porte, porém são poucos efetivos quando aplicados na solução de sistemas de grande porte) propos-se metodologias de otimização combinatorial para o estudo deste problema. Assim, estudaram-se quatro metodologias de otimização que foram aplicadas no estudo do planejamento de sistemas de transmissão denominadas ?Simulated Annealin? (SA), Algoritmos Genéticos (AG), Busca Tabu (TS) e Algoritmo Híbrido, chamadas metaheurísticas. Cada uma das quatro metodologias apresenta diferentes características na sua implementação, ou seja, em cada uma destas se determinam seus parâmetros de controle, a estrutura de vizinhança e seu próprio algoritmo. Nestes métodos, dada uma configuração, se deseja passar ao melhor vizinho através de entrada e saída de linhas. Em cada uma delas é usado o Modelo de Fluxo de Carga DC para realizar a modelagem da rede elétrica, sendo o mesmo resolvido através de um PL... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Not informed. / Doutorado / Doutor em Engenharia Elétrica
104

Estudo experimental do resfriamento de particulas solidas em trocador de calor com leito fluidizado raso

Parise, Maria Regina 23 August 2000 (has links)
Orientador: Arai Augusta Bernardez Pecora / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-27T05:09:45Z (GMT). No. of bitstreams: 1 Parise_MariaRegina_M.pdf: 4405768 bytes, checksum: acb30c218e2eae7284fc2e1a4f580a6b (MD5) Previous issue date: 2000 / Resumo: O projeto de trocadores de calor operando com leito fluidizado gás-sólido contendo tubos imersos exige o conhecimento prévio do fenômeno de transferência de calor entre suspensão gássólido e superficie imersa. A revisão da literatura mostra que fatores empíricos são necessários quando um trocador de calor com leito fluidizado é analisado. Este trabalho apresenta o estudo experimental de um recuperador de calor com fluxo contínuo de sólidos operando com leito fluidizado raso. O resfriamento das partículas foi realizado através do escoamento de água, em arranjo contracorrente, no interior de um tubo imerso no leito. A temperatura de entrada do material sólido no trocador situou-se entre 490 e 710°C em nossos experimentos. Os experimentos foram realizados visando a determinação da influência da descarga de sólidos e do número de chicanas no leito fluidizado sobre o processo. O material sólido utilizado foi areia com diâmetro médio de 254 micro m, fluidizada com ar em trocador de calor com 900 mm de comprimento e 150 mm de largura. As medidas foram rea1izadas em regime permanente para descargas de sólidos variando entre 10 e 100 kg/h e. número de chicanas entre O e 8. Os experimentos sem chicanas foram realizados visando verificar a influência da presença de chicanas no processo de transferência de calor. O leito fluidizado possuia 60 mm de altura e a relação uJ11mf variou entre 2,9 e 4,7. Medidas da temperatura do leito ao longo do comprimento do trocador de calor e balanços de energia em volumes de controle diferenciais foram realizados permitindo a obtenção do perfil do coeficiente de transferência de calor suspensão-parede. Esse coeficiente também foi obtido segundo uma análise global do trocador. Os resultados mostraram que o aumento da descarga de sólidos e do número de chicanas provocou o aumento do coeficiente de transferência de calor suspensão-parede, sendo portanto parâmetros que devem ser considerados no projeto de tais equipamentos. A análise dos resultados também mostrou que o aumento do número de chicanas provocou aumento da efetividade do trocador de calor enquanto que o aumento da descarga de sólidos provocou efeito inverso / Abstract: The design of heat exchangers with gas-solid fluidized bed and immersed tubes requires previous knowledge of heat transfer involving gas-solid suspension and tube surtàce. Literature review shows that empirical factors are required when a fluidized bed exchanger is ana1yzed. This work presents an experimental study of a continuous gas-solid fluidized bed with an immersed tube where cold water flowing inside the tube is heated, in a counter flow arrangement, by solid particles with inlet temperature ftom 490 to 71 O°C. Experiments were carried out to check the influence of solids flow rate and distance between baffles immersed in a shallow fluidized bed. The solid material utilized was silica sand particles 254 J1m diameter fluidized by air in a heat exchanger 900mm length and 150mm width. Measurements were made at steady state conditions for solids mass flow rate ftom 10 to 100 kg/h and number of baffles from O to 8. Experiments without baft1es were conducted in order to ana1yze the influence of the presence of baffles in the heat transfer processes. The bed was 60 mm height and the factor u/umf varied ftom 2,9 to 4,7. Bed temperature measurements along the length of the heat exchanger was experimentally obtained and heat balances for differential control volumes of the heat exchanger were made in order to obtain the axial profile of the suspension-tube heat transfer coefficient. This coefficient was a1so obtained by a global heat balance. Resuhs showed that heat transfer coefficient increases with the solids mass flow rate and with the number of baffles suggesting that these are important tàctors to be considered in the design of such heat exchangers. Results also showed that the effectiveness of the heat exchanger increases with the number of baffles while the opposite was obtained with the increase of the solid mass flow rate / Mestrado / Termica e de Fluidos / Mestre em Engenharia Mecânica
105

Impactos socioambientais da implantação de linha de transmissão de energia elétrica sobre as comunidades extrativistas do babaçu no Estado do Maranhão

Maria Portela Ferreira da Silva, Ilka January 2006 (has links)
Made available in DSpace on 2014-06-12T18:04:13Z (GMT). No. of bitstreams: 2 arquivo8149_1.pdf: 4816629 bytes, checksum: 119f5439604c1556edca7952e827b02f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / Esta dissertação tem como objeto de estudo os impactos ambientais provenientes da construção de linhas de transmissão de energia elétrica, mais especificamente no estado do Maranhão, onde foram impactadas treze comunidades extrativistas do babaçu. A construção de empreendimentos para transmissão de energia elétrica traz grandes benefícios para a sociedade, porém, no desempenho de sua missão, a empresa empreendedora, utiliza os recursos naturais e desenvolve atividades que afetam o meio ambiente. Torna-se necessário, então que sejam norteadas as ações da empresa, nas fases de planejamento, implantação e operação de seus empreendimentos. O processo de Gestão Ambiental desses empreendimentos envolve a elaboração de estudos e programas ambientais (Estudos de Impacto Ambienta - EIA, Relatório de Impacto Ambiental - RIMA e Plano Básico Ambiental - PBA) para atender às exigências da legislação ambiental. A Linha de Transmissão trecho 1 possui 198 km de extensão, atravessa dez municípios dos estados do Maranhão e Piauí, dentre os quais seis (06) mais diretamente impactados, tendo em vista residirem nos mesmos quatrocentos e noventa e seis (496) famílias extrativistas do babaçu. Daí, a principal razão para estudar detalhadamente o modus vivendi dos moradores, utilizando uma metodologia participativa entre a empresa empreendedora e as comunidades impactadas. Nesse sentido foi elaborados e implementados o Programa de Comunicação, Educação e Saúde Ambiental PESA, que consistiu de capacitações comunitárias, oficinas, palestras e visitas técnicas, com o intuito de esclarecer, conscientizar e orientar às comunidades do entorno do empreendimento, sobre a necessidade da construção da linha de transmissão, os impactos causados, bem como os cuidados que deverão ter antes, durante e após a sua construção. Os estudos mostraram que para a construção da Linha de Transmissão 500 kV Presidente Dutra/Fortaleza II no trecho 1 Presidente Dutra/Teresina, foram atingidos 124,14 hectares de matas de babaçu, no estado do Maranhão. Registrou-se também como impactos no meio físico a geração e aumento de processos erosivos, a modificação na drenagem natural dos recursos hídricos e a emissão de zumbido em conseqüência da alta freqüência da linha de transmissão (efeito corona). Em atendimento às solicitações das comunidadesdistribuíram-se animais de serviços, máquinas trituradoras e filtros de barro. Essas ações complementares propiciaram uma melhoria significativa na qualidade de vida dos moradores do entorno do empreendimento
106

Rede de transmissão SDH: planejamento da camada logica (PCLOG)

Banov, Joana Teixeira Machado 22 April 1999 (has links)
Orientador: Raul Vinhas Ribeiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T15:16:25Z (GMT). No. of bitstreams: 1 Banov_JoanaTeixeiraMachado_M.pdf: 4454162 bytes, checksum: 58c4780a65bbdd49b1da0b697a9e8af8 (MD5) Previous issue date: 1999 / Resumo: A nova tecnologia de equipamentos de transmissão da Hierarquia Digital Síncrona (SDH - Synchronous Digital Hierarchy) vem compor um novo cenário tecnológico no mundo das Telecomunicações, revolucionando o atendimento aos serviços atuais e futuros e dando suporte à implementação da Rede Digital de Serviços Integrados - RDSI. Esta tese apresenta uma nova visão do planejamento da Rede SDH de Transmissão, baseada numa arquitetura de rede decomposta em camadas funcionais. A divisão em camadas funcionais possibilita o desenvolvimento de uma metodologia de planejamento para cada camada funcional. A decomposição proposta aqui considera quatro camadas: de circuitos, lógica, de transmissão e física. Neste trabalho propomos uma metodologia de Planejamento da Camada Lógica, camada funcional cuja função é "arrumar" demandas de canais El (2Mbits/s), ou de ordem superior, em containers virtuais VC-4. A atividade de arrumar eficientemente tributários dentro de VC-4 é essencial, já que um VC-4 acrescido de um cabeçalho de seção (SOH ¿ Section OverHead) toma-se um STM-l, sinal de transporte básico SDH. . A metodologia de planejamento da Camada Lógica tem o objetivo de minimizar o úmero de containers VC-4 e a quantidade de vezes que as demandas em 2Mbits/s são transpostas de um VC-4 para o outro ao longo de seu trajeto na rede. ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Synchronous Digital Hierarchy (SDH) is a new technology in the area of transmission, and it has brought numerous advantages to the world of telecommunications. It guarantees a moreflexible and efficient transmission network, capable of meeting the service needs of telecommunications, both present and future. The present work proposes a methodology for planning an SDH transmission network based on the decomposition of the network into functional layers. The planning of such a transmission network is based on this decomposition, and each of the layers is considered independently, taking into consideration the information of the higher leveI. The architecture of the network presented in this study is a network decomposed into four functionallayers: Circuit Layer, Path Layer, with high and low orders sub-Iayers, Transmission Media Layer and PhysicalLayer. A planning algorithm for the Path Layer is proposed which will provide input for the next lower transmission media layer. The Path Layer is the layer responsible for the all ocation of the 2Mbits/s channels (El) into virtual containers (VC). Groups of these virtual containe rs, alongwith the Section Overhead (SOH), form STM-l modules (Synchronous Transport Modules), which are the basic transport signals of SDH transmission. The planning of the path layer is designed to minimize the number of containers required, as well as the number of times the 2 Mbits/s demands are transposed from one VC to another during transmission through the network. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Elétrica
107

Uma contribuição ao estudo do comportamento termico e do desempenho eletrico de motores de indução com rotor em gaiola

Avolio, Edwin 17 March 1992 (has links)
Orientador: Ernesto Ruppert Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T02:30:38Z (GMT). No. of bitstreams: 1 Avolio_Edwin_D.pdf: 7529482 bytes, checksum: 9c2f1dd08a5b44e8bd0c6763e625d2f1 (MD5) Previous issue date: 1992 / Resumo: Apresenta-se um modelo matemático térmico e elétrico para um motor de indução com rotor em gaiola o qual permite especificar sob Condições térmicas e elétricas, baseado somente e dados de catálogos e informações técnicas de fabricantes o melhor motor a um acionamento. Considera-se as variações dos parâmetros do rotor devido ao efeito pelicular e as variações das resistências dos enrolamentos do estator e do rotor com a temperatura. A precisão do modelo é comprovada experimentalmente. Obtém-se o comportamento térmico e o desempenho elétrico de alguns motores para regimes de funcionamento contínuo e intermitente com alimentação senoidal e não senoidal / Abstract: A thermal-e1ectric mathematical model for a squirrel cage induction motors which permits to specify the best motor for specific drive, under thermal and electric aspects based, only on manufacturer technical bul1etins and technical information is presented. Changes of rotor parameters due Skin effect and changes of winding resistances (both stator and rotor) with the temperature are considered. The accuracy of this model is appraised using experimental results. The thermal behavior and electric performance for some motors are obtained for continuous and intermittent duties with sinusoidal and nonsinusoidal volt ages / Doutorado / Doutor em Engenharia Elétrica
108

Equalização adaptativa para modens de dados

Araujo, Roberto Silva Lucattelli 17 June 1988 (has links)
Orientador : Fabio Violaro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T03:06:10Z (GMT). No. of bitstreams: 1 Araujo_RobertoSilvaLucattelli_M.pdf: 12539895 bytes, checksum: deec74938dc63141c8394d41dedc1b8d (MD5) Previous issue date: 1988 / Resumo: Neste trabalho estudam-se os sistemas de comunicação de dados em canais telefônicos na faixa de voz (modens de dados). As principais contribuições são a apresentação detalhada da teoria de equalização adaptativa e dos algoritmos de sincronismo de símbolos e de portadora, a verificação da análise teórica através de simulações realizadas com sistemas práticos (linhas telefônicas reais), e uma modificação no algoritmo de ajuste dos coeficientes do equalizador transversal (algoritmo do gradiente modificado), com a qual se obtém um aumento significativo na velocidade de convergência em relação ao algoritmo convencional / Mestrado / Mestre em Engenharia Elétrica
109

Acoplamento por abertura entre microfita/guia e microfita/microfita

Dória Neto, Adrião Duarte 14 July 2018 (has links)
Orientadores: Attilio Jose Giarola, Adaildo Gomes D'Assunção / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T13:07:49Z (GMT). No. of bitstreams: 1 DoriaNeto_AdriaoDuarte_M.pdf: 3092808 bytes, checksum: 0266928c736ba50bff8e59e6aeed12b4 (MD5) Previous issue date: 1982 / Resumo: Neste trabalho é apresentado um estudo do acoplamento por abertura entre o guia de onda retangular e a linha de microfita. É analisado também o acoplamento por abertura entre duas microfitas. É utilizada, na análise do acoplamento por abertura, a teoria dos momentos de dipolos equivalentes, que consiste em substituir a abertura por momentos de dipolos, os quais irradiam campos eletromagnéticos equivalentes aos irradiados pela abertura. Considera-se também, neste trabalho, a distribuição de campos eletromagnéticos existentes na microfita, para o modelo quase estático utilizado. Esta forma de distribuição de campos permite que sejam obtidas expressões de acoplamento nas quais se considera o campo na abertura uniforme ou não uniforme. A partir do estudo do acop,lamento por uma única abertura, foi desenvolvida uma análise do acoplamento por múltiplas aberturas entre microfitas, e entre guia de onda retangular e microfita. Utilizando-se a análise desenvolvida para o acoplamento por múltiplas aberturas entre duas microfitas, foram projetados e construídos dois acopladores direcionais com quatro aberturas. A comparação dos resultados experimentais obtidos com os previstos teoricamente revela uma boa concordância. / Abstract: Not informed / Mestrado / Mestre em Engenharia Elétrica
110

Uso de realimentação externa em projeto e construção de oscilador transistorizado de microonda

D'Assunçao, Adaildo Gomes 14 July 2018 (has links)
Orientadores: Attilio Jose Giarola, David Anthony Rogers / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T16:45:37Z (GMT). No. of bitstreams: 1 D'Assuncao_AdaildoGomes_M.pdf: 3433421 bytes, checksum: 74d30e61ff1303b6cc9c8c9e3def901a (MD5) Previous issue date: 1977 / Resumo: A finalidade deste trabalho foi desenvolver um metodo para projeto de oscilador transistorizado de microonda com sintonia mecânica. estabelecendo assim um roteiro básico ao desenvolvimento de osciladores controlados a voltagem por varactor. O método que faz uso de realimentação externa em serie. foi desenvolvido a partir da caracterização do transistor pelos parâmetros de espalhamento lineares. A realimentação e introduzida através de tocos de linhas de transmissão que são facilmente realizáveis em microfita. A determinação da realimentação e das admitâncias de entrada e de saída do transistor realimentado e feita através de programas de computação. Os circuitos introduzidos na entrada e na sarda do transistor são projetados de modo a satisfazer respectivamente as condições para oscilação permanente e fornecer transferência de potência adequada. A Carta de Smith e alguns programas de computação são utilizados para auxiliar nesta análise. Para efetuar uma comprovação prática, projetamos e construímos um oscilador de microonda, sintonizado mecanicamente, com frequência central de 1.5 GHz. A caracterização dos circuitos em microfita foi feita a partir de programa de computaçao. Na construção destes circuitos foi utilizada a tecnologia, de circuitos impressos / Abstract: Not informed / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.0462 seconds