• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Detailed Heat Transfer Measurements of Various Rib Turbulator Shapes at Very High Reynolds Numbers Using Steady-state Liquid Crystal Thermography

Zhang, Mingyang 18 January 2018 (has links)
In order to protect gas turbine blades from hot gases exiting the combustor, several intricate external and internal cooling concepts are employed. High pressure stage gas turbine blades feature serpentine passages where rib turbulators are installed to enhance heat transfer between the relatively colder air bled off from the compressor and the hot internal walls. Most of the prior studies have been restricted to Reynolds number of 90000 and several studies have been carried out to determine geometrically optimized parameters for achieving high levels of heat transfer in this range of Reynolds number. However, for land-based power generation gas turbines, the Reynolds numbers are significantly high and vary between 105 and 106. Present study is targeted towards these high Reynolds numbers where traditional rib turbulator shapes and prescribed optimum geometrical parameters have been investigated experimentally. A steady-state liquid crystal thermography technique is employed for measurement of detailed heat transfer coefficient. Five different rib configurations, viz., 45 deg., V-shaped, inverse V-shaped, W-shaped and M-shaped have been investigated for Reynolds numbers ranging from 150,000 to 400,000. The ribs were installed on two opposite walls of a straight duct with aspect ratio of unity. For very high Reynolds numbers, the heat transfer enhancement levels for different rib shapes varied between 1.3 and 1.7 and the thermal hydraulic performance was found to be less than unity. / Master of Science / Gas turbine blades operate in hot gases exiting from combustor. The temperature of the hot gas is much higher than the melting point of blades material. To protect gas turbine blades several intricate external and internal cooling technique have been applied. Inside the blades, impingement cooling, rib turbulators cooling and pin fins cooling technique are applied in the leading edge, central body and trailing edge, respectively. At the central body serpentine passage was manufactured where rib turbulators are installed to enhance heat transfer between the relatively colder air bled off from the compressor and the hot internal walls. This is attributed to the colder air’s boundary layer is tripped by the rib turbulators enhance the flow turbulence. All the previous works are based on lower Reynolds number (under 90000) which always happens in aircraft gas turbine engine. In land based gas turbine the Reynolds numbers of cooling air are significantly high and vary between 10⁵ and 10⁶ . Present study is targeted towards these high Reynolds numbers where traditional rib turbulator shapes and prescribed optimum geometrical parameters have been investigated experimentally. Five different rib configurations, viz., 45 deg., V-shaped, inverse V-shaped, W-shaped and M-shaped have been investigated for Reynolds numbers ranging from 150,000 to 400,000. For very high Reynolds numbers, the heat transfer enhancement levels for different rib shapes varied between 1.3 and 1.7 and the thermal hydraulic performance was found to be less than unity. It’s a caution to turbine hot gas path designers, particularly for the cases where rib designs for aircrafts are used in land based power generationgas turbines
2

MEASUREMENTS IN A ROTATING SERPENTINE DUCT WITH MULTIPLE RIB ARRANGEMENTS

Bharadwajh, Rahul 01 January 2003 (has links)
The effect of rotation on flow in a gas turbine blade cooling duct model is investigated experimentally. The present work consists of velocity measurements at different locations in a test section with a 180° bend with ribs on one wall. Three geometric rib parameters are considered; rib-rib spacing, rib orientation angle and rib blockage ratio. PIV is used for flow visualization and analysis. Along with the clean duct measurements, ribs with blockage ratios, b/h, of 0.25 and 0.125 were considered. The b/h = 0.25 cases have been comprehensively analyzed while the b/h = 0.125 cases have been studied at the post-bend region of the duct only. Reynolds number considered is in the range of approximately 5000-40,000 and the rotation speed is varied for a rotation number from 0 to 7. It is observed that rotation has a significant effect on secondary flows within the rotating duct. For blockage ratio, b/h = 0.25, at a constant Re and Ro, the RMS of fluctuations of velocity do not show large spatial variations with ribs or rib orientations. At higher Re, the value decreases in comparison to the low Re cases. The kinetic energy of fluctuations increases due to the presence of ribs, indicating better heat transfer for the ribbed duct, but do not show large variations with rib orientation angle. The fluctuations and kinetic energy show maximum values at the post-bend regions of the duct. The velocity fields and PDFs show a possible cause for e°cient heat transfer for the 45° rib arrangement as compared with the 90° rib cases. At high Ro, the absolute value of circulation has a large increase at the post-bend and thereafter there is a gradual decay at the exit for all cases. The ribs with blockage ratio of b/h = 0.125 showed no marked changes in circulation with changes in rib orientation angle, thus implying that the rib blockage plays a role in the generation of secondary flows, particularly in conjunction with rotation.
3

Heat Transfer Performance Improvement Technologies for Hot Gas Path Components in Gas Turbines

Ravi, Bharath Viswanath 14 June 2016 (has links)
In the past few decades, the operating temperatures of gas turbine engines have increased significantly with a view towards increasing the overall thermal efficiency and specific power output. As a result of increased turbine inlet temperatures, the hot gas path components downstream of the combustor section are subjected to high heat loads. Though materials with improved temperature capabilities are used in the construction of the hot gas path components, in order to ensure safe and durable operation, the hot gas path components are additionally supplemented with thermal barrier coatings (TBCs) and sophisticated cooling techniques. The present study focusses on two aspects of gas turbine cooling, namely augmented internal cooling and external film cooling. One of the commonly used methods for cooling the vanes involves passing coolant air bled from the compressor through serpentine passages inside the airfoils. The walls of the internal cooling passages are usually roughened with turbulence promoters like ribs to enhance heat transfer. Though the ribs help in augmenting the heat transfer, they have an associated pressure penalty as well. Therefore, it is important to study the thermal-hydraulic performance of ribbed internal cooling passages. The first section of the thesis deals with the numerical investigation of flow and heat transfer characteristics in a ribbed two-pass channel. Four different rib shapes- 45° angled, V-shaped, W-shaped and M-shaped, were studied. This study further aims at exploring the performance of different rib-shapes at a large rib pitch-to-height ratio (p/e=16) which has potential applications in land-based gas turbines operating at high Reynolds numbers. Detailed flow and heat transfer analysis have been presented to illustrate how the innate flow physics associated with the bend region and the different rib shapes contribute to heat transfer enhancement in the two-pass channel. The bend-induced secondary flows were observed to significantly affect the flow and heat transfer distribution in the 2nd pass. The thermal-hydraulic performance of V-shaped and 45° angled ribs were better than W-shaped and M-shaped ribs. The second section of the study deals with the analysis of film cooling performance of different hole configurations on the endwall upstream of a first stage nozzle guide vane. The flow along the endwall of the airfoils is highly complex, dominated by 3-dimensional secondary flows. The presence of complex secondary flows makes the cooling of the airfoil endwalls challenging. These secondary flows strongly influence endwall film cooling and the associated heat transfer. In this study, three different cooling configurations- slot, cylindrical holes and tripod holes were studied. Steady-state experiments were conducted in a low speed, linear cascade wind tunnel. The adiabatic film cooling effectiveness on the endwall was computed based on the spatially resolved temperature data obtained from the infrared camera. The effect of mass flow ratio on the film cooling performance of the different configurations was also explored. For all the configurations, the coolant jets were unable to overcome the strong secondary flows inside the passage at low mass flow ratios. However, the coolant jets were observed to provide much better film coverage at higher mass flow ratios. In case of cylindrical ejection, the effectiveness values were observed to be very low which could be because of jet lift-off. The effectiveness of tripod ejection was comparable to slot ejection at mass flow ratios between 0.5-1.5, while at higher mass flow ratios, slot ejection was observed to outperform tripod ejection. / Master of Science
4

Effect of rib aspect ratio on heat transfer and friction in rectangular channels

Tran, Lucky Vo 01 January 2011 (has links)
The heat transfer and friction augmentation in the fully developed portion of a 2:1 aspect ratio rectangular channel with orthogonal ribs at channel Reynolds numbers of 20,000, 30,000, and 40,000 is studied both experimentally and computationally. Ribs are applied to the two opposite wide walls. The rib aspect ratio is varied systematically at 1, 3, and 5, with a constant rib height and constant rib pitch (rib-pitch-to-rib-height ratio of 10). The purpose of the study is to extend the knowledge of the performance of rectangular channels with ribs to include high aspect ratio ribs. The experimental investigation is performed using transient Thermochromic Liquid Crystals technique to measure the distribution of the local Nusselt numbers on the ribbed walls. Overall channel pressure drop and friction factor augmentation is also obtained with the experimental setup. A numerical simulation is also performed by solving the 3-D Reynolds-averaged Navier-Stokes equations using the realizable-k-Greek lowercase letter episilon] turbulence model for closure. Flow visualization is obtained from the computational results as well as numerical predictions of local distributions of Nusselt numbers and overal channel pressure drop. Results indicate that with increasing rib width, the heat transfer augmentation of the ribbed walls decreases with a corresponding reduction in channel pressure drop.
5

Pressure Drop And Endwall Heat Transfer Effects Of Porous Turbulators In A Rectangular Channel

Pent, Jared 01 January 2009 (has links)
This study examines the local and averaged endwall heat transfer effects of a staggered array of porous pin fins within a rectangular channel. The porous pin fins were made from aluminum and had a pore density of 10 pores per inch (PPI). The pressure drop through the channel was also determined for several flow rates and presented in terms of the friction factor. Local heat transfer coefficients on the endwall were measured using Thermochromic Liquid Crystal (TLC) sheets recorded with a charge-coupled device (CCD) camera. Static and total pressure measurements were taken at the entrance and exit of the test section to determine the overall pressure drop through the channel and explain the heat transfer trends through the channel. Results are presented for Reynolds numbers between 25000 and 130000 and a blockage ratio (blocked channel area divided by open channel area) of 50%. All results were compared to the corresponding results obtained using solid pins. All experiments were carried out in a 150 mm by 500 mm channel with an X/D of 1.72, a Y/D of 2.0, and a Z/D of 1.72 for the porous pins. It was found that for the range of Reynold's numbers tested in this study, the porous pin array consistently resulted in a larger friction factor, and therefore greater losses than a geometrically similar array of solid pins. The friction factors for the solid pin array were between 9.5 and 10.5, similar to the results found in the literature. For the porous pins, however, the friction factors were significantly increased as the Reynold's number increased, reaching as high as 15.3 at the highest Reynold's number tested. The heat transfer enhancement for the porous pins was found to be between 150 and 170% while the solid pins resulted in a heat transfer enhancement between 190 and 230%.
6

Experimental measurements of conjugate heat transfer on a scaled-up gas turbine airfoil with realistic cooling configuration

Dees, Jason Edward 07 October 2010 (has links)
This study performed detailed measurements on and around scaled up conducting and adiabatic airfoils with and without film cooling. The conducting vane was a matched Bi airfoil, which accurately scaled the convective heat transfer and conduction through the solid, in order to produce non-dimensional surface temperatures and thermal boundary layers that were representative of an actual engine. Measurements made on all vane models included surface temperature measurements and thermal profiles above the walls. Separate measurements on non-film cooled and film cooled conducting models allowed for the individual contributions of the internal convective cooling and external film cooling to the overall cooling scheme to be quantified. Surface temperature and thermal field measurements above the wall were also performed on a film cooled adiabatic model. For the conducting model with internal cooling only, strong streamwise temperature variations were seen. The surface temperature variations were highly dependent on the local external and internal heat transfer coefficients. Spanwise temperature variations also existed, but were modest in comparison to streamwise variations. Comparing the thermal fields above the film cooled adiabatic and conducting walls allowed for the assumption that the conducting wall would not significantly affect the thermal field in the film cooling jet to be tested. Near the edge of the film cooling jet the developing thermal boundary layer had a clear effect on the overlying gas temperature, suggesting that the common assumption that the adiabatic wall temperature is the appropriate driving temperature for heat transfer to a film cooled wall was invalid. On the jet centerline thermal boundary layer effects were less influential, due to the development of a new, thin boundary layer. This suggested that the adiabatic wall temperature as driving temperature for heat transfer was a reasonable assumption on the jet centerline for most cases tested. As film cooling momentum flux ratio increase, thermal boundary layer effects became more influential on the jet centerline. Additionally, the high resolution surface temperature measurements and thermal field measurements above the wall presented in the current study represent a significant improvement in the data available for validation of computational simulations of conducting turbine airfoils. / text

Page generated in 0.0548 seconds