• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Extração de mercúrio de solos e sedimentos auxiliada por ultra-som

Collasiol, André January 2004 (has links)
Desenvolveu-se uma metodologia que dispensa a dissolução completa da amostra para determinar Hg em solos, sedimentos fluvial e marinho. O Hg é quantitativamente extraído do sedimento marinho usando-se HNO3 30% (v/v), ultra-som (120 s, 70 W) e granulometria ≤ 120 µm. Condições similares são eficientes para sedimento fluvial e solo, exceto o tempo de sonicação (180 s) e a adição de KCl 0,15% (m/v). As suspensões sonicadas são centrifugadas e o Hg é determinado no sobrenadante por FI-CV AAS. A validação da metodologia foi feita com CRMs: PACS-2, MESS-3 (NRCC); Buffalo River (NIST 8704), Montana Soil (NIST 2710) e RS-3 (não certificada). Os parâmetros de mérito do método são: massa característica de 25 pg; LD (3s) de 0,2 µg l–1; LQ (10s) de 0,012 µg g–1 (800 µl de solução obtida de 1 g de amostra em 20 ml de suspensão). Aplicou-se a metodologia à análise de amostras reais (solo, sedimentos fluvial e marinho), as quais também foram preparadas com digestão ácida (85 °C durante 3 h) em mistura oxidante (K2S2O8 1 a 2% (m/v) e HNO3 30% (v/v)). Concentrações concordantes foram obtidas. Utilizou-se calibração externa e, quando necessário, ajuste de matriz com KCl ou K2S2O8. Para investigar a extração de Hg orgânico utilizando ultra-som, adicionou-se MeHg aos CRMs. Aproximadamente 5% do MeHg adicionado transformam-se em Hg2+ pelo método proposto, enquanto que chega a 100% quando a amostra é digerida. Assim, propõe-se uma especiação química semiquantitativa entre Hg inorgânico e orgânico, pois o Hg orgânico pode ser obtido pela diferença entre Hg total (determinado pela digestão) e Hg inorgânico (determinado pelo método proposto).
62

Extração de mercúrio de solos e sedimentos auxiliada por ultra-som

Collasiol, André January 2004 (has links)
Desenvolveu-se uma metodologia que dispensa a dissolução completa da amostra para determinar Hg em solos, sedimentos fluvial e marinho. O Hg é quantitativamente extraído do sedimento marinho usando-se HNO3 30% (v/v), ultra-som (120 s, 70 W) e granulometria ≤ 120 µm. Condições similares são eficientes para sedimento fluvial e solo, exceto o tempo de sonicação (180 s) e a adição de KCl 0,15% (m/v). As suspensões sonicadas são centrifugadas e o Hg é determinado no sobrenadante por FI-CV AAS. A validação da metodologia foi feita com CRMs: PACS-2, MESS-3 (NRCC); Buffalo River (NIST 8704), Montana Soil (NIST 2710) e RS-3 (não certificada). Os parâmetros de mérito do método são: massa característica de 25 pg; LD (3s) de 0,2 µg l–1; LQ (10s) de 0,012 µg g–1 (800 µl de solução obtida de 1 g de amostra em 20 ml de suspensão). Aplicou-se a metodologia à análise de amostras reais (solo, sedimentos fluvial e marinho), as quais também foram preparadas com digestão ácida (85 °C durante 3 h) em mistura oxidante (K2S2O8 1 a 2% (m/v) e HNO3 30% (v/v)). Concentrações concordantes foram obtidas. Utilizou-se calibração externa e, quando necessário, ajuste de matriz com KCl ou K2S2O8. Para investigar a extração de Hg orgânico utilizando ultra-som, adicionou-se MeHg aos CRMs. Aproximadamente 5% do MeHg adicionado transformam-se em Hg2+ pelo método proposto, enquanto que chega a 100% quando a amostra é digerida. Assim, propõe-se uma especiação química semiquantitativa entre Hg inorgânico e orgânico, pois o Hg orgânico pode ser obtido pela diferença entre Hg total (determinado pela digestão) e Hg inorgânico (determinado pelo método proposto).
63

Avaliação dos efeitos do laser de baixa potência e do ultrassom terapêutico no desempenho muscular : um ensaio clínico randomizado controlado

Craveiro, Wesley Albuquerque 25 September 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós Graduação Stricto-Sensu em Ciências e Tecnologias em Saúde, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2015-01-26T15:59:54Z No. of bitstreams: 1 2014_WesleyAlbuquerqueCraveiro_Parcial.pdf: 180105 bytes, checksum: 21cf59df64320a1b37e46c0d888ba3fe (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2015-01-30T15:25:05Z (GMT) No. of bitstreams: 1 2014_WesleyAlbuquerqueCraveiro_Parcial.pdf: 180105 bytes, checksum: 21cf59df64320a1b37e46c0d888ba3fe (MD5) / Made available in DSpace on 2015-01-30T15:25:05Z (GMT). No. of bitstreams: 1 2014_WesleyAlbuquerqueCraveiro_Parcial.pdf: 180105 bytes, checksum: 21cf59df64320a1b37e46c0d888ba3fe (MD5) / Introdução: A procura incessante em melhorar o desempenho no esporte de alta performance leva o atleta a expor seu corpo a situações extremas, culminando com a perda do rendimento muscular. Nesse sentido, são necessárias estratégias tanto para aprimorar o desempenho esportivo em um curto período assim como acelerar a recuperação após um treino ou no decorrer da própria competição. [12,14,15]; O Laser de Baixa Potência (LBP) e o Ultrassom Terapêutico são recursos que vem ganhando destaque no cenário esportivo, cujos efeitos parecem contribuir para esse propósito. Objetivo: Analisar a influência do laser terapêutico e do ultrassom no desempenho do musculo tibial anterior após uma série de 25 repetições de exercícios isocinéticos concêntricos. Método: 36 participantes, gênero feminino, sem histórico prévio de lesões nos últimos seis meses, que se consideravam inativas ou sedentárias, média de idade 19,82±1,33 anos, massa corporal média de 56±7,97Kg média de altura 162 ±5,18cm, o Índice de Massa Corporal (IMC) média 21,23±2,76, randomicamente divididas em cinco grupos: um grupo controle (GC), grupo laser placebo (GLP), grupo laser ativo (GLA), grupo ultrassom placebo (GUP) e grupo ultrassom ativo (GUA). Todos os grupos realizaram duas baterias de avaliações, separadas por um período de 24 horas, que consistiu em exame físico, testes de força e questionários de aptidão física. O GC foi apenas acompanhado durante o período, enquanto os grupos ativos (GLA e GUA) receberam a aplicação dos recursos sobre a região dos músculos tibiais anteriores dos membros direitos e os grupos placebos (GLP e GUP) seguiram o mesmo protocolo porém, com os equipamentos desligados. Resultados: Após 24 horas todas as voluntárias foram capazes de repetir o mesmo teste. Em relação aos grupos em que foram utilizados os recursos terapêuticos (laser e ultrassom), não foi observada diferença significativa (p>0,05) em todas as comparações. Conclusão: O laser de baixa potência e o ultrassom, nas condições metodológicas deste experimento, não foram capazes de influenciar o desempenho do musculo tibial anterior. _________________________________________________________________________________ ABSTRACT / Backgroud: The constant search for improved performance in high performance sport takes the athlete to expose your body to extreme situations, culminating in the loss of muscle performance. Accordingly, strategies are needed both to improve sports performance in a short period as well as speed recovery after a workout or during the competition itself. [10,14,08]; The Low Power Laser (LBP) and the Therapeutic Ultrasound are resources that have been emphasized in the sports arena, whose effects appear to contribute to this purpose. Objective: To analyze the influence of therapeutic laser and ultrasound in the performance of the tibialis anterior muscle after a series of 25 repetitions of concentric isokinetic exercises. Method: 36 participants, females without previous history of injury in the last six months, which is considered inactive or sedentary, mean age 19.82 ± 1.33 years, mean body mass of 56 ± 7,97Kg average height 162 ± 5,18cm, the average Body Mass Index (BMI) 21.23 ± 2.76, randomly divided into five groups: a control group (CG), placebo laser group (LPG), active laser group (GLA), group placebo ultrasound (GUP) and active ultrasound group (GUA). All groups performed two batteries of assessments, separated by a 24-hour period, which consisted of physical examination, strength tests and questionnaires on physical fitness. The GC was only matched during the period, while the active groups (GLA and GUA) were applied the resources on the region of the anterior tibial muscles of the right members and the placebo groups (LPG and GUP) followed the same protocol but with equipment turned off. Results: After 30 repetitions of concentric isokinetic exercises in ankle dorsiflexion, the anterior tibial muscle showed traces of muscle fatigue, the continued exercise realization that time is not possible. After 24 hours all subjects were able to repeat the same test. In the groups in which the therapeutic resources (laser and ultrasound) were used, no significant difference (p> 0.05) in all comparisons. Conclusion: The low-power laser and ultrasound, the methodological conditions of this experiment were not able to influence the performance of the tibialis anterior muscle
64

Modelagem de ensaios não destrutivos por ultra-som utilizando o método dos elementos finitos. / Modeling of ultrasonic non destructive evaluation using FEM.

Jimmy Ernesto San Miguel Medina 21 December 2005 (has links)
Os modelos existentes de propagação de ondas de ultra-som em meios líquidos e sólidos consideram a geração e recepção das ondas produzidas por transdutores simulados segundo o modelo do pistão plano ou com excitações cuja amplitude varia radialmente no pistão. Esses modelos são simplificados e não explicam completamente o comportamento real de transdutores de ultra-som interagindo com líquidos e sólidos. As verificações experimentais de propagação da onda de ultra-som em meios líquidos mostram que a onda de borda é diferente da onda plana. Observa-se também a existência de outras ondas não previstas nos modelos anteriores. Essas ondas são conhecidas como ondas head. A utilização do método dos elementos finitos (MEF) para a modelagem de propagação de ondas de ultra-som, incluindo o transdutor piezelétrico, permite a obtenção de resultados realísticos, conseguindo assim descrever com maior precisão o comportamento do transdutor e das ondas de ultra-som se propagando em diferentes meios e interagindo com defeitos que se comportam como refletores. Apesar disso, os resultados desses modelos dependem das características precisas dos materiais que compõem o transdutor. O transdutor de ultra-som é composto por uma cerâmica piezelétrica, por camadas de casamento e de retaguarda que geralmente são compósitos de epóxi com alumina e epóxi com tungstênio respectivamente, e pelo encapsulamento. Neste trabalho é analisada a resposta transiente de um transdutor circular de 2 MHz, com diâmetro de 12,7 mm, banda larga. O modelo do transdutor foi implementado com o método de elementos finitos. A análise transiente pelo MEF é implementada com o software ANSYS. Na primeira parte do trabalho o transdutor é analisado no modo de transmissão em água. Os resultados do modelo com MEF foram comparados com os resultados do modelo do pistão plano e com verificações experimentais obtidas em tanque de imersão com um hidrofone tipo agulha. Na segunda parte é realizada a análise do transdutor operando em modo pulso-eco radiando em peças de teste com e sem defeito, utilizando acoplamento direto e acoplamento por buffer de água. Os resultados do MEF apresentam boa concordância com os resultados obtidos experimentalmente. / Simple models for ultrasonic wave propagation in liquid and solid media consider the wave generation and reception by transducers that behave as plane pistons. These models are simplified and they do not explain completely the behavior of an ultrasonic transducer when interacting with other media. Experimental verifications of ultrasonic wave propagation in liquid show that the pressure amplitude of the edge wave is different from the plane wave. Also it is observed the existence of other types of waves not foreseen in these previous models. These waves are known as head waves. More realistic models for ultrasonic wave propagation are obtained using the finite element method (FEM). These models include the piezoelectric transducer, thus, describing with higher precision the behavior of the transducer and the ultrasonic waves propagating in different mediums and interacting with defects. The precision of the models depends on the accurate determination of the mechanical and electrical properties of the involved materials. The ultrasonic transducer is composed by a piezoelectric ceramic, a matching layer and a backing layer that are generally made by epoxy/alumina and epoxy/tungsten composites respectively. In this work it is analyzed the transient response of a circular transducer of 12.7 mm diameter and 2 MHz center frequency. The transducer model was implemented with the finite element method. The FEM transient analysis was executed in the ANSYS software. In the first part of the work the transducer is analyzed in transmission mode in water and the MEF results are compared with the plane piston model and with experimental verifications using a hydrophone. In the second part it is carried at the transducer analysis operating in pulse-echo mode radiating into test pieces with and without defects, using direct and water buffer coupling. The MEF results show good agreement with the results obtained experimentally in the laboratory.
65

Otimização do algoritmo de block matching aplicado a estudos elastográficos / Otimization of the block matching algorithm aplied to elastogtraphic studies.

Lucio Pereira Neves 03 August 2007 (has links)
Este trabalho apresenta uma análise sobre um novo método de formação de imagem, utilizando aparelhos de ultra-som a elastografia. Esta técnica baseia-se no fato de que quando um meio elástico, como o tecido, é deformado por uma tensão constante e uniaxial, todos os pontos no meio possuem um nível de deformação longitudinal cujo componente principal está ao longo do eixo de deformação. Se elementos do tecido possuem um módulo elástico diferente dos demais, a deformação nestes elementos será relativamente maior ou menor. Elementos mais rígidos geralmente deformam-se menos. Desta forma, pode-se mapear e identificar estruturas com diferentes níveis de dureza. A comparação entre os mapas de RF de pré e pós-deformação foi realizada pela técnica de block matching. Esta técnica consiste em comparar regiões, ou kernels, no mapa de pré-deformação com regiões de mesmo tamanho no mapa de pós-deformação. Esta comparação é feita pela minimização de uma função custo. Nesta técnica, o tamanho do kernel, é um dos principais parâmetros para melhorar a precisão das medidas de deslocamento. O principal objetivo neste trabalho é aperfeiçoar o algoritmo de block matching visando melhorar a precisão da determinação de deslocamento em técnicas de deformação dinâmica e estática, mantendo o custo computacional baixo. Para isto, foram utilizados phantoms com e sem inclusões mais duras que o meio. Os phantoms foram submetidos a deformações estáticas e dinâmicas. Foi possível determinar o comportamento destes phantoms sob estas formas de deformação, e as faixas de kernel e funções custo que forneceram os melhores resultados. Também foram gerados elastogramas do phantom com inclusão. Estas imagens permitiram avaliar a influência dos diferentes kernels sobre a resolução dos elastogramas e a capacidade em diferenciar a lesão do tecido circundante. Comparando os elastogramas obtidos sobre deformação dinâmica, utilizando os kernels que apresentaram o melhor desempenho, com as respectivas imagens em modo B, pôde-se observar que a inclusão estava clara e bem delimitada. / This work provides an analysis about a new method for image formation using ultrasound devices elastography. This technique is based on the fact that when an elastic medium, as the tissue, is deformed under a constant and directional stress, all the points in the medium have a deformation level whose main component is along the deformation axis. If tissues elements have different elastic modules, the deformation in these elements will be higher or lower. Normally harder elements have lower deformations. In this way, one can detect and identify structures with different elastic levels. The comparisons between the pre and post-deformation RF maps were done by the block matching technique. This technique is based on the comparison of regions, or kernels, in the pre-deformation maps with regions of the same size in the post-deformation map. This is done by the minimization of a cost function. In this technique, the kernel size is one of the most important parameters to obtain better resolution and precision in the displacement measurements. The goal of this work is to optimize the block matching algorithm to improve the displacement estimates precision in both dynamic and static deformations, while keeping a low computational cost. To obtain this, we used phantoms with and without inclusions harder than the medium. These phantoms were submitted to both static and dynamic deformations. It was possible to estimate the behavior of these phantoms under these deformations, and the kernel range and cost functions that provided the best results. Also, we generated the elastograms of the phantom with the inclusion. These images allowed us to evaluate the influence of the different kernel sizes under the elastograms resolution and their capability in differentiate the lesion from the embedding tissue. Comparing the elastograms obtained under dynamic deformation that had the best performance, with the B mode images, we could conclude that the inclusion was well delimited and clear.
66

Os efeitos do ultra-som terapêutico aplicado na fase precoce da cicatrização do tendão flexor. estudo biomecânico em tendões de coelho.

Cristiane Vitaliano Graminha Romano 21 June 2001 (has links)
Foi realizado um estudo experimental dos efeitos do ultra-som terapêutico sobre a resistência à tração de tendões flexores em cicatrização, usando o tendão flexor dos dedos de coelho como modelo. Foram utilizados 25 coelhos fêmea, da raça Nova Zelândia, adultos jovens de 3 Kg de peso corporal médio. Todos os animais foram operados sob anestesia geral para terem o tendão flexor profundo do terceiro dedo da pata dianteira direita seccionado e imediatamente reparado com a técnica de Kessler. As patas operadas eram imobilizadas com uma órtese de material termoplástico durante todo o período do experimento (4 semanas) e os animais foram distribuídos em dois grupos ( A e B) de acordo com o tratamento pós-operatório. No grupo A (13 animais) todos os animais receberam uma aplicação diária de 6 minutos de duração de ultra-som pulsado (1:5), regulado para uma freqüência de 3 MHz e intensidade de 0,8 W/cm², por sete dias consecutivos começando do primeiro dia. O grupo B (12 animais) era apenas de controle. Quatro semanas mais tarde, os animais eram mortas e todo o tendão operado era ressecado, incluindo a junção miotendínea e o segmento distal, e submetidos aos testes de resistência à tração na máquina universal de ensaios. Gráficos das cargas versus a deformação foram obtidos, permitindo a análise dos parâmetros carga e deformação máximas, carga e deformação no limite de proporcionalidade e rigidez. Os resultados mostraram que não houve diferenças significantes entre os grupos A e B, levando à conclusão de que o ultra-som terapêutico não tem influência no curso do processo de cicatrização dos tendões, particularmente no que se refere à resistência mecânica. / An experimental study of the effects of the therapeutic ultrasound on the resistance to traction of healing flexor tendons carried out using the rabbit flexor tendon as model. Twenty five young adult female New Zeland rabbits of average 3 Kg body weight were used. All the animals were operated under general anesthetics to have the profundus flexor tendon of the third finger of the right forepaw divided and immediately repaired with Kessler technique. The operated on paw was immobilized with an orthesis made of thermoplastic material for the entire length of the experiment (four weeks) and the animals were divided in two groups (A and B), according to the postoperative treatment. In group A (13 animals) all animals received one 6 minutes daily application of pulsed ultrasound (1:5), set for 3 MHz frequence and 0,8 W/cm² intensity, for seven consecutive days beginning on the first postoperative day. Group B (12 animals) was for control only. Four weeks later, the animals were killed, the entire operated tendons were resected including the myotendinous junction and the distal segment and submitted to the test of resistance to traction in a universal testing machine. Load versus deformation graphs were obtained allowing for the analysis of the parameters maximum load and deformation, load and deformation in the limit of proportionality, and stiffness. The results showed that there was no significant difference between groups A and B, leading to the conclusion that therapeutic ultrasound does not influence the course of the tendon healing process, as refers to mechanical resistance.
67

Estudo de propriedades mecânicas de dicotiledôneas por meio de ensaio não-destrutivo utilizando equipamento de ultra-som / not available

Fabiana Goia Rosa de Oliveira 08 May 2001 (has links)
Este trabalho apresenta um estudo sobre a aplicação de ondas ultra-sônicas na madeira visando a avaliação de suas propriedades mecânicas. Esta avaliação é baseada na relação entre a velocidade do som, o módulo de elasticidade e a densidade. Utilizaram-se as seguintes espécies: eucalipto grandis, eucalipto citriodora, cupiúba e jatobá. O procedimento experimental foi dividido em duas etapas: a primeira referente a corpos-de-prova pequenos e a segunda com peças de dimensão estrutural. Foram realizados ensaios para a determinação das seguintes propriedades físicas e mecânicas: densidade aparente a um teor de umidade de 12% (&#961ap,12%), resistência e módulo de elasticidade longitudinal à compressão paralela às fibras (fc0 e Ec0), módulo de elasticidade na flexão estática (EM) e módulo de ruptura (MOR). Também foram feitos ensaios com ultra-som para obtenção do coeficiente da matriz de rigidez (CLL), a fim de comparação com os resultados estáticos. Com os dados obtidos, realizou-se análise estatística com o intuito de verificar a existência de relações entre as variáveis em estudo. Os resultados obtidos e as análises realizadas permitem concluir que o método não destrutivo por meio de ultra-som, pode ser utilizado para caracterizar as propriedades mecânicas de dicotiledôneas nativas e de florestamento com confiabilidade. / This work presents a study of an application of ultrasonic techniques in order to characterize mechanical properties of wood. The ultrasonic wave application is based on the relationship between the speed of the sound, the modulus of elasticity and the density. The species of wood used were: eucalipto grandis, eucalipto citriodora, cupiúba and jatobá. The experimental program was divided in two steps: the first related to small samples, and the second one related to samples with structural dimensions. Rehearsals were accomplished for the determination of the following physical and mechanical properties: apparent density at 12% (&#961ap, 12%), strength and modulus of elasticity in compression parallel to the grain (fc0 and Ec0), modulus of elasticity (EM) and modulus of rupture (MOR). They were also made ultrasonic measurements for obtaining the elastic stiffness (CLL), in order to comparison with the static results. The experimental results show that it is possible to use the ultrasonic technique satisfactorily to characterize wood mechanically, obtaining reliable relationships.
68

Efeitos do ultra-som de baixa intensidade na osseointegração de implantes de titânio em tíbia de coelho: avaliação histomorfométrica e mecânica. / Low intensity ultrassound effects on osseointegration of titanium implants in rabbit tibia: histomorphometric and mechanical tests.

Antonio Renato Sanches Colucci 10 July 2002 (has links)
O efeito do ultra-som de baixa intensidade no reparo ósseo tem sido investigado em experimentos animais e clínicos no Brasil e exterior. Essas investigações resultaram em uma tecnologia não invasiva para o tratamento de fraturas aprovada pela Agência Nacional de Vigilância Sanitária (Brasil) e pelo Food and Drug Administration (FDA - EUA). Os resultados obtidos no tratamento de fraturas motivaram investigações sobre os efeitos do mesmo ultra-som na osseointegração de implantes metálicos (EUA). Neste estudo foram utilizados 18 coelhos da raça Nova Zelândia, com peso entre 2,5 e 3,0 kg. Em cada tíbia foram inseridos 2 implantes de titânio de uso comercial em odontologia com superfície tratada por subtração ácida e com dimensões de 3,75mm X 8,5 mm. Os implantes da tíbia esquerda foram tratados por ultra-som de baixa intensidade por 20 minutos diários, durante 3, 5 e 7 semanas. Os da tíbia direita foram usados como controle. A osseointegração nos implantes foi avaliada por testes mecânicos e histomorfométricos. Os implantes tratados por ultra-som apresentaram em regiões ao redor das espiras superiores, após 3 e 5 semanas, maior quantidade de osso calcificado que nos implantes não tratados. Não houve significância estatística na quantidade de osso calcificado nas espiras de ambos os grupos após 7 semanas. As espiras de ambos os grupos, tratados e não-tratados, em contato com o osso cortical da tíbia, foram totalmente preenchidas por tecido ósseo após 3, 5 e 7 semanas da sua colocação. Os ensaios mecânicos de torque por desroqueamento e força de arrancamento não detectaram diferença na resistência mecânica entre implantes tratados e não-tratados por ultra-som após 3, 5 e 7 semanas. A resistência mecânica apresentada pelos testes mecânicos nesta investigação parece ser dependente do preenchimento total ou parcial das espiras dos implantes e não da quantidade de tecido ósseo calcificado presente. / The low intensity ultrasound effect in bone repair has been investigated in animal and clinical experiments in Brazil and other countries. The result of these investigations was the development of a non-invasive technology for treating fractures which has been approved by FDA (USA) and by an agency (ANVISA) of the Brazilian Ministry of Health. The success in treating fractures motivated studies on the effects of the same ultrasound on bone ingrowth into metallic implants. In this study two commercial titanium dental implants (STE) with 3,75mm X 8,5mm were inserted bilaterally in the tibia of New Zealand rabbits (n=18) weighing between 2.5 - 3.0 kg. The implants in the left tibia were subjected to 20 minutes daily ultrasound treatment for 3, 5 and 7 weeks. The implants in the right tibia served as a control. The osseointegration in the implants was analysed by mechanical tests (torsion and pull-out) and histomorfometry. The implants treated by ultrasound showed more calcified bone in its threads and surrounding areas after 3 and 5 weeks than nontreated implants. The difference in the amount of calcified bone was not statiscally significant in the treated and non treated implants after 7 weeks. The area of treated and non-treated implants in contact with cortical bone was full filled with bone after 3, 5 and 7 weeks. Mechanical tests (torsion and pull-out) did not show differences statistically significant between treated and non-treated implants after 3, 5 and 7 weeks. The mechanical resistance of the implants seems to be more dependent on the amount of bone in the implants threads than the amount of calcified bone existing in the threads and surrounding areas.
69

Extração de mercúrio de solos e sedimentos auxiliada por ultra-som

Collasiol, André January 2004 (has links)
Desenvolveu-se uma metodologia que dispensa a dissolução completa da amostra para determinar Hg em solos, sedimentos fluvial e marinho. O Hg é quantitativamente extraído do sedimento marinho usando-se HNO3 30% (v/v), ultra-som (120 s, 70 W) e granulometria ≤ 120 µm. Condições similares são eficientes para sedimento fluvial e solo, exceto o tempo de sonicação (180 s) e a adição de KCl 0,15% (m/v). As suspensões sonicadas são centrifugadas e o Hg é determinado no sobrenadante por FI-CV AAS. A validação da metodologia foi feita com CRMs: PACS-2, MESS-3 (NRCC); Buffalo River (NIST 8704), Montana Soil (NIST 2710) e RS-3 (não certificada). Os parâmetros de mérito do método são: massa característica de 25 pg; LD (3s) de 0,2 µg l–1; LQ (10s) de 0,012 µg g–1 (800 µl de solução obtida de 1 g de amostra em 20 ml de suspensão). Aplicou-se a metodologia à análise de amostras reais (solo, sedimentos fluvial e marinho), as quais também foram preparadas com digestão ácida (85 °C durante 3 h) em mistura oxidante (K2S2O8 1 a 2% (m/v) e HNO3 30% (v/v)). Concentrações concordantes foram obtidas. Utilizou-se calibração externa e, quando necessário, ajuste de matriz com KCl ou K2S2O8. Para investigar a extração de Hg orgânico utilizando ultra-som, adicionou-se MeHg aos CRMs. Aproximadamente 5% do MeHg adicionado transformam-se em Hg2+ pelo método proposto, enquanto que chega a 100% quando a amostra é digerida. Assim, propõe-se uma especiação química semiquantitativa entre Hg inorgânico e orgânico, pois o Hg orgânico pode ser obtido pela diferença entre Hg total (determinado pela digestão) e Hg inorgânico (determinado pelo método proposto).
70

Influência do sulfato de condroitina e da lectina de semente de Cratylia mollis (Cramoll, 1,4) em relação à crioterapia e ultrassom terapêutico sobre lesão em cartilagem do joelho de coelhos

Veiga, Paulo Henrique Altran 08 1900 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-04-17T15:15:30Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE DOUTORADO ARQUIVO UNICO PARA BIBLIOTECA (1.pdf: 1427600 bytes, checksum: 264276f1444fd2b25a895c531a6488bf (MD5) / Made available in DSpace on 2015-04-17T15:15:30Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE DOUTORADO ARQUIVO UNICO PARA BIBLIOTECA (1.pdf: 1427600 bytes, checksum: 264276f1444fd2b25a895c531a6488bf (MD5) Previous issue date: 2012-08 / Esta pesquisa visou avaliar a influência de um medicamento comercial (condroton®), cujo componente ativo é o sulfato de condroitina e da lectina de semente de Cratylia mollis (Cramoll 1,4) associados à crioterapia e ultrassom terapêutico, em lesão de cartilagem do joelho de coelhos. O extrato da semente de C. mollis 10% (p/v) foi preparado em NaCl 0,15 M, fracionado com sulfato de amônio (40-60% de saturação). A fração obtida (F40- 60) foi submetida a cromatografia de afinidade em Sephadex G-75. Cramoll 1,4 foi obtida por eluição bioseletiva com D-glicose 0,3 M em NaCl 0,15 M, dialisada contra NaCl 0,15 M durante 24 h, e liofilizada. O estudo foi realizado através da análise das comunidades celulares (média de 250 células/indivíduo), obtidas nos estudos histológicos. Foram utilizados 18 coelhos machos da raça Califórnia, albinos, pesando entre 2,5 a 3,5 Kg, correspondendo de dois a três meses de idade (Masoud et al., 1986), totalizando uma média de 4500 células analisadas. Foi realizada lesão na cartilagem, simulando osteoartrose nos joelhos dos coelhos, e posteriormente, os animais foram divididos em nove grupos (2 indivíduos/grupo) de tratamento. Grupo controle (GC) com nenhum procedimento terapêutico; Grupo submetido à aplicação de gelo (GG); Grupo submetido à terapia com ultrassom terapêutico tipo pulsado, marca KLD Avatar II®, com freqüência de 1 MHz, intensidade de 535 mW/cm2 (0,5W/cm2), pulso de 2:8 e previamente calibrado (GU); Grupo que recebeu injeção intra muscular de condroton® (GSC); Grupo que recebeu Cramoll 1,4 (GCramoll); Grupo submetido à aplicação de gelo e injeção de condroton® (GGSG); Grupo submetido a terapia com ultrassom e condroton® (GUSG); Grupo submetido à aplicação de gelo e Cramoll 1,4 (GGCramoll) e, Grupo submetido a terapia com ultrassom e Cramoll 1,4 (GUCramoll). Os resultados obtidos demonstraram que, quando comparadas a utilização do ultrassom terapêutico com condroton® (p=0,0251*); e ultrassom terapêutico com Cramol 1,4 (p=0,0414*), houve aumento da área do sulfato de condroitina em ambos os grupos, porém, este aumento foi maior no grupo tratado com Cramoll 1,4. A utilização de crioterapia concomitante ao uso de condroton® ou Cramol 1,4, não demonstrou diferenças no estudo, quando comparados os efeitos do tratamento entre 60 e 90 dias. A utilização de Cramol 1,4 aumentou a área do sulfato de condroitina (p=0,0001*), na osteoartrose da cartilagem do joelho de coelhos em 60 e 90 dias de tratamento, em comparação com o grupo controle. Observou-se também, aumento da área do colágeno com a utilização do condroton® com 60 dias de tratamento, (p=0,0001*), porém, diminuindo sua área no período de 90 dias. Desta forma os autores concluiram que o ultrassom terapêutico e a Cratylia mollis 1,4 tem efeitos positivos sobre a osteoartose induzida experimentalmente nos coelhos.

Page generated in 0.0848 seconds