• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Estudo morfofuncional de rins de primatas Callithrix jacchus em cativeiro / Morphofunctional study in kidneys of captive Callithrix jacchus primates

Cristiane Macedo Del Rio do Valle 06 June 2008 (has links)
Analisou-se rins de 51 Callithrix jacchus, 38 animais provenientes do DPZ (Centro de Primatas da Alemanha) e 13 animais provenientes do CENP (Centro Nacional de Primatas - Brasil), para a caracterização morfológica e biométrica dos rins desta espécie, utilizando-se de exames ultra-sonográficos e radiográficos, comparando-se os dados de cada colônia para verificação de possíveis diferenças decorrentes de manejos distintos. Foram realizados exames de urina e sangue para verificar a condição de sanidade dos animais. Foi realizada também a histologia do rim em 19 animais do DPZ. Com os resultados pudemos concluir que nos animais do DPZ, os parâmetros mensurados não são influenciados pelo sexo. Os Callithrix jacchus da colônia do DPZ apresentaram a biometria corpórea maior do que os Callithrix jacchus da colônia do CENP e os animais com alterações renais apresentaram peso maior do que os animais sadios. No exame ultra-sonográfico, o rim desta espécie apresenta aspecto ovalado, é unipiramidal, e a relação de ecogenicidade é igual à descrita para outras espécies de primatas. Houve a isoecogenicidade do fígado e do baço em relação ao rim. Nos animais do CENP, a região cortical e medular e a junção cortico-medular foram mais definidas do que nos animais do DPZ. Os aspectos radiográficos para os rins de Callithrix jacchus foram semelhantes ao descrito para outras espécies. Os rins de animais com alterações apresentaram um volume maior do que os rins de animais sadios. Foram observadas alterações histológicas nos rins dos animais necropsiados, mesmo no grupo dos animais sem alterações laboratoriais. / The kidneys of fifty one Callithrix jacchus, being thirty eight animals from the DPZ (Germany Primate Center) and thirteen animals from the CENP (National Primate Center - Brazil), were used in the present experiment. Kidneys morphological and biometrical characterizations were evaluated using ultrasonographic and radiographic exams. Comparisons were performed between each colony in order to evaluate the effect of different management. Soundness evaluation was performed in all animals using blood and urine analysis. The kidneys of nineteen animals from the DPZ were used for histological evaluations. Results indicate that variables were not influenced by gender on DPZ animals. Animals from the DPZ colony showed higher values of body biometry than those from the CENP colony. Furthermore, animals showing renal alterations presented higher weight when compared to healthy animals. At the ultra-sonographic exam, the kidney of this specie showed an elliptical and unipyramidal aspect, with an echogenicity similar to other primates species previously described. Kidney echogenicity was also similar to the liver and spleen. At the CENP, animals showed better definition at the cortical and the medullar region, as well as the cortico-medular junction, when compared to the DPZ. The radiographic aspects of the Callithrix jacchus kidneys were similar to species previously described. Kidneys from animals with alterations showed a higher volume when compared to the healthy animals. Histological kidney abnormalities were found at necropsy also on animals with no laboratorial alterations.
182

Influencia da vibração na permeabilidade absoluta de meios porosos saturados com agua / Influence of the vibration on the absolute permeability of porous media satured with water

Pompeo Neto, Luiz Benedicto 20 December 2004 (has links)
Orientadores: Euclides Jose Bonet, Kamal Abdel Radi Ismail / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T01:56:31Z (GMT). No. of bitstreams: 1 PompeoNeto_LuizBenedicto_M.pdf: 311727 bytes, checksum: f5aafe4c0c4ba7418df2f2fc710c02a8 (MD5) Previous issue date: 2004 / Resumo: Neste trabalho foram verificados experimentalmente os efeitos da vibração mecânica na permeabilidade absoluta de meios porosos saturados com água e sob a imposição simultânea de um escoamento uniforme. Após a identificação de uma faixa de excitação em que se excluem efeitos indiretos da vibração, como os decorrentes do aquecimento ultra-sônico do conjunto e da desintegração mecânica da matriz rochosa, foi possível verificar que a vibração a freqüências ultra-sônicas reduz a diferença de pressão ao longo da amostra e reduz a vazão através da amostra. A combinação de magnitude desses dois efeitos pode resultar em aumento da permeabilidade absoluta, sendo que as variações, além da freqüência, ainda dependem da velocidade do escoamento externamente imposto. A análise do problema através da mecânica do contínuo permitiu introduzir a descrição de um modelo físico, baseado no conceito da película viscosa de espessura inversamente proporcional à freqüência. O mecanismo é capaz de explicar o comportamento observado. Os fenômenos mostraram-se decorrência das propriedades elásticas, dadas as propriedades hidrodinâmicas, do sistema composto pela matriz sólida e pelo fluido que preenche o meio poroso saturado e por ele escoa / Abstract: This work verifies experimentally the effects of the mechanical vibration on the absolute permeability of saturated porous media upon which a uniform flow is simultaneously imposed. After finding a driving range within which indirect effects of the vibration are excluded, such as those resulting from ultrasonic heating and mechanical disintegration of the rock matrix, it was possible to verify that vibration at ultrasonic frequencies reduces the pressure drop across the sample and reduces the flow rate through it. The combination of amplitude of both these effects may result the improvement of the absolute permeability. Besides depending on the frequency, such changes depend on the velocity of the externally imposed flow. Analysis of the problem making use of continuum mechanics permitted introducing the description of a physical model, based on the concept of the viscous skin depth inversely proportional to the frequency. The mechanism is capable of explaining the observed behavior. The phenomena turned out to result from the elastic properties ¿ given the hydrodynamic properties ¿ of the system composed by the solid matrix together with the fluid, which fills and flows through the saturated porous medium / Mestrado / Instrumentação e Controle Industrial / Mestre Profissional em Engenharia Mecanica
183

Hemorragia periventricular-intraventricular : incidencia em recem-nascidos vivos e sua associação com idade gestacional, peso, crescimento intrauterino e obito neonatal

Marba, Sérgio Tadeu Martins, 1958- 18 July 2018 (has links)
Orientador : Maria Aparecida Brenelli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-18T10:43:50Z (GMT). No. of bitstreams: 1 Marba_SergioTadeuMartins_M.pdf: 2049911 bytes, checksum: 6b272c6b097a97f7c0437f33ddcaaaff (MD5) Previous issue date: 1993 / Resumo: Com a finalidade de analisar a hemorragia periventricular-intraventricular (HPIV) no Serviço de Neonatologia do Centro de Atenção Integral à Saúde da Mulher da Faculdade de Ciências Médicas da Universidade Estadual de Campinas, foram estudados 169 recém-nascidos com peso entre 500 e 1.750 gramas, no período entre abril de 1991 e agosto de 1992. Para o diagnóstico, utilizou-se a ultra-sonografia transfontanelar ou o exame anatomopatológico cerebral. A incidência de HPIV foi de 37%, com 31% grau I, 43% grau 11, 18% grau 111 e 8% grau IV. Numa primeira etapa avaliou-se a associação da idade gestacional, do peso e do crescimento intra-uterino com a HPIV; em uma segunda etapa, a associação da idade gestacional, do peso, do crescimento intra-uterino e da HPIV, em relação ao óbito neonatal. Para o cálculo estatístico, foram utilizadas a análise univariada e múltipla com regressão logística. Apenas o peso permaneceu como fator de risco independente, tanto para a HPIV como para o óbito neonatal. Em relação à idade gestacional, ela foi fator de risco significativo para a HPIV somente na análise univariada. Em relação ao óbito neonatal, tanto a idade gestacional como a HPIV foram fatores de risco somente na análise uni variada. Concluiu-se que a HPIV é uma patologia de alta incidência neste grupo de crianças e que o peso foi o único fator de risco independente associado à HPIV e ao óbito neonatal. / Abstract: With the purpose of studying periventricular-intraventricular hemorrhage in the Neonatology Service of the Center for Integral Assistance to Women's Health, 169 newborns with weight ranging from 500 to 1750 grammes were analyzes, from April 1991 through August 1992 were analised. Transfontanelar ultrasonography or anatomo-pathological examination were used for diagnosiso The incidence of HPIV was 37%, with 31% grade I, 43% grade 11, 18% grade 111 e 8% grade IV. In the first step, the association between gestational age, newborn weight and intra-uterine growth with HP IV were studied, followed by an analysis of the correlation among gestational age, newborn weight, intrauterine growth and presence of HPIV with neonatal death. Univariate analysis and multiple analysis with logistic regression were used for statistical purposes. Only the newborn weight remained as an independent risk factor for both HPIV and neonatal death. The gestacional age, was a significant variable for HPIV in the univariate analysis only. As for neonatal death both gestational age and HPIV were significant risk factors in the univariate analysis. In conclusion, HPIV is high incidence disease in this group of newborns and the low birth weight was the only independent risk factor for HPIV and neonatal death. / Mestrado / Mestre em Pediatria
184

Os efeitos do ultra-som terapêutico nas lesões da epiderme de coelhos / The effects of therapeutic ultrasound on the damage of rabbits skin

Ana Regina de Souza Bavaresco Barros 13 March 2002 (has links)
O ultra-som terapêutico é o recurso físico mais empregado como coadjuvante na promoção do reparo tecidual em vários tipos de lesão de partes moles. Neste trabalho, foi estudada a influência do ultra-som terapêutico no processo de cicatrização de feridas cutâneas num modelo experimental em coelhos. Foram utilizados 36 coelhos adultos, nos quais foram produzidas três lesões cutâneas no dorso, pela ressecção de um segmento circular de pele de 1 cm de diâmetro, distando 5 cm uma da outra, em linha. Uma das lesões era submetida ao tratamento efetivo com o ultra-som, a outra era submetida a tratamento placebo e a terceira era deixada intocada. Os animais foram divididos em dois grupos de 18 cada, conforme a intensidade do ultra-som aplicado, de 0,8 W/cm2 e 0,4 W/cm2, respectivamente. O tratamento foi iniciado no primeiro dia pós-operatório e aplicado diariamente até o sétimo dia, após o que os animais eram sacrificados e as lesões eram ressecadas com larga margem de segurança, para posterior exame histopatológico. Foram obtidos cortes histológicos de 5 &#956m de espessura, corados com duas técnicas e examinados ao microscópio de luz. Os parâmetros avaliados foram o infiltrado inflamatório, fibrose e reepitelização, aos quais foram atribuídos valores numéricos, de 0 a 3, que permitissem a análise estatística. Os resultados mostraram que o ultra-som induz a alterações teciduais e celulares variáveis, mas não significativas em nenhum dos parâmetros avaliados. / Therapeutic ultrasound is the most used adjunct physical resource to promote tissue repair in many types of soft tissue lesion. In the present work the influence of therapeutic ultrasound on the healing process of skin wounds was studied in rabbits. Thirty-six adult rabbits were used, three round skin wounds of 1 cm in diameter being made on the dorsum about 5 cm in line from one another. Ultrasound treatment was applied to one of the wounds only, a placebo being applied to another and the third being left untouched. The animals were distributed into two groups of 18 according to the intensity of the ultrasound applied, of 0.8 W/cm2 and 0.4 W/cm2, respectively. The treatment was started on the first postoperative day and applied daily till the seventh day. The animals were killed the next day and the wounds were resected with a wide safety margin for histology, 5 &#956m-thick sections being cut and died with two different techniques. The sections were examined on the light microscope for inflammatory infiltrate, fibrosis and regeneration of the epithelium, which were quantified from 0 to 3, so as to make the statistical study possible. Results showed that ultrasound induces cell and tissue alterations but not significantly in any of the parameters analyzed.
185

Efeitos do ultra-som terapêutico na prevenção de aderências tendinosas / Effect of the therapeutical ultrasound in the prevention of tendinosas tacks

Rosângela Lobato 18 December 2002 (has links)
O trabalho realizado estudou experimentalmente os efeitos do ultra-som terapêutico na prevenção de aderências tendinosas e no reparo tendíneo. Foi selecionado para o estudo o tendão flexor profundo do 3º dedo na transição das zonas 3 e 4 da pata dianteira direita de coelho. Foram utilizados 30 coelhos fêmeas adultas jovens, com peso corporal médio de 2,7 Kg, divididos em 3 grupos (A, B e C) de 10 animais, sob anestesia para a produção da lesão no tendão, feita por escarificação com o uso do bisturi e o esmagamento num segmento de 5 mm de diâmetro, utilizando um dispositivo de carga de 15 Kg, durante 10 minutos. As patas foram imobilizadas com órtese de material termoplástico durante todo o período experimental (21 dias). O ultra som terapêutico foi iniciado no 3º PO, e continuado por 7 dias consecutivos, com 5 minutos de duração. Foi empregado um ultra-som terapêutico, regulado na freqüência de 3 MHz, no modo contínuo, sendo que a intensidade de 0,2 W/'CM POT.2' foi aplicada nos animais do grupo A, 0,4 W/'CM POT.2' no grupo B e ultra-som desligado como placebo no grupo C. No 21º PO os animais foram sacrificados, e o tendão submetido à análise histológica. Os resultados foram submetidos à análise estatística e demonstraram que houve uma menor formação de aderência no grupo A. A aceleração do reparo tendinoso foi observada em todos os grupos / The work accomplished studied experimentally the effects of therapeutics ultrasound in prevention of tendon adherences and in tendon repair. The deep flexor tendon of the 3rd finger between zones 3 and 4 of a rabbit's right fore-foot was selected for the study. Thirty young adult female rabbits, with a body weight average of 2.7 Kg, divided into 3 groups (A, B, and C) of 10 animals each, were used. The tendon injury was made, under the effect of anesthesia, by reaming with the use of a scalpel, and the 5mm diameter crushing was made by the use of a device of 15 Kg load for 10 minutes. The feet were immobilized with orthesis made of thermoplastic material during all the experiment period (21 days). A therapeutics ultrasound, set at the frequency of 3 MHz, was applied. The intensity of 0.2 W/'CM POT.2' was applied to the animals of group A; 0.4 W/'CM POT.2' to the group B; and the equipment was off when applied to group C as a placebo. The therapeutics ultrasound was started in the 3rd PO and kept on for 7 consecutive days, with a duration of 5 minutes. On the 21st day the animals were sacrificed; the tendon was analysed histologically. The results were analysed statistically and showed that there was a minor adherence formation in group A. The acceleration of the tendon repair was observed in all groups
186

Estudo dos efeitos do ultra-som de baixa intensidade e do exercício físico sobre consolidação de fraturas em ratos diabéticos / Study of the effect of the ultrasound of low intensity and the physical exercise on consolidation of breakings in diabetic rats

Juciléia Barbosa Bezerra 04 March 2005 (has links)
O diabetes Mellitus é uma doença na qual o organismo perde a habilidade de regular adequadamente o metabolismo dos carboidratos e é caracterizada entre outros sintomas, por hiperglicemia permanente. Especificamente, o diabetes Tipo I, está associado com a diminuição da integridade do tecido ósseo e, por isso, mais propenso à fraturas. Esta pesquisa refere-se ao estudo aplicação do ultra-som e do exercício físico (natação) como formas de consolidação de fraturas em fíbulas de ratos diabéticos e apresenta resultados das avaliações glicêmicas, radiológicas, histológica e de microscopia de luz polarizada. A avaliação do grau de birrefringência nos permitiu observar que os animais diabéticos, tanto os exercitados quanto os tratados apresentaram melhores resultados que os controles. O tratamento com ultra-som de baixa intensidade e o exercício físico foram eficazes na consolidação de osteotomias experimentais / Diabetes Mellitus is a desease characterized by lost of ability in the regulating the carbohydrate metabolism and it is represented by constant hiperglycaemia and others sintoms. Among the types of diabetes, the type I, is associated with the decrease of the bone tissue integrity and therefore more susceptible to fractures. This research is related to the aplication of ultrasound and physical exercise(swimming) to help healing of osteotomized fibulae in diabetics rats. The results were evaluated by glycaemics, radiological, hystological and polarized light microscopy analysis. Birefringence analysis showed that diabetic animals, exercited and treated with ultrasound presented better results as compared to the controls. The treatment with low intensity ultrasound and physical exercise demonstrated efficacy in experimental healing fractures
187

Estudo dos efeitos da irradiação pulsada de baixa intensidade sobre o desenvolvimento de segmentos de coluna vertebral implantados em camundongos isogênicos / Low-intensity pulsed ultrasonic irradiation effects on development of vertebral column segments implanted in isogenics mice

Andrezza Furquim da Cruz 15 April 2005 (has links)
Estudo dos efeitos da irradiação ultra-sônica pulsada de baixa intensidade sobre o desenvolvimento de segmentos da coluna vertebral implantados em camundongos isogênicos / The aim of the present research was evaluate the action of low-intensity pulsed ultrasonic irradiation on development and ossification of vertebral column blastemas, through mice new born tail segments implants in adult receptor isogenic mice lineages C57BL/6 and Balb/C. New born tail segments were implanted in subcutaneous tissues of adults isogenics mice C57BL/6 and intramuscularly in adults isogenics mice Balb/C. After 24 hours the implant, the animals in both groups, were stimulated with the low-intensity pulsed ultrasound (LIPUS), 10 minutes per day. After 5 days of stimulus, the receptors animals were death and had the implanted tails removed for histopathology, trhrough Periodic Acid Schiff plus Alcian Blue (PAS/AB), Masson's tricomico and hem lumen-eosin (HE). The group of animals stimulated which received subcutaneous implant presented the implant with accelerated in inter-vertebral diks, faces to chondrocytes organization and chondroblastes findings in cartilaginous matrix, showing maturity in fiber cartilages arrangements. It was observed too, a collagen fibers enlargement in the disks fibro cartilage which show more dense next the pulposo nucleus in the segments implanted and stimulated, compared with the controls segments. The areas of the segments were available by Fisher's test and Student's t. It didn't watch significant differences in the vertebral bodies' areas sizes in the animals which implant was subcutaneous (p'< OU = '0.05). In the intramuscular implants animals group, it was observed a major velocity in the hialuronic acid matrix formation in the intervertebral disks after LIPUS stimulus. Moreover, the fibrous ring fiber cartilages' were better organized with large number of cells inside the cartilaginous matrix compared with the controls segments. With regard to the vertebral bodies in the intramuscular implants, it's not verifies significant increases in the areas (p'< OU =' 0,05). The findings allow conclude that LIPUS should promote the ontogenetic differentation of the structural components of the mice vertebral column more quickly, trhough vertebras endochondral ossification microscopic evaluation and the inter-vertebral disks components differentiation, follow the methodology employed.
188

Estudo experimental dos efeitos do ultra-som pulsado de baixa intensidade sobre a regeneração do nervo ciático de ratos após neurotomia, mediante avaliações morfológicas e morfométricas.

Ana Rosa Crisci 05 June 2001 (has links)
As qualidades biofísicas do U.S.P. levaram-nos a estimar o efeito do mesmo sobre a regeneração de um nervo periférico. Este estudo foi levado a efeito sobre a axotomia experimental do nervo ciático de ratos. Para tal finalidade estimulamos por 12 dias consecutivos, durante 20 minutos o coto proximal dos nervos axotomizados. A morfologia foi avaliada comparativamente entre cortes semifinos corados pelo azul de toluidina e cortes ultra finos à microscopia eletrônica, dos cotos proximais de nervos estimulados e não estimulados. A avaliação morfométrica das estruturas, baseou-se na contagem diferencial das fibras; da espessura da bainha de mielina e da área dos axônios das fibras tipo A, mediante o emprego de um software especializado ( Image Tool). Os achados morfológicos e a análise estatística dos dados morfométricos são altamente sugestivos de que o U.S.P. estimula a regeneração de nervos periféricos. / The biophysical qualities of pulsed ultrasound led us to appraise it¢s effect on the regeneration of a peripheral nerve. In this study our intention was to evaluate the effects of pulsed ultrasound on the axotomy of the ciatic nerve in rats. The proximal stump of the nerve was stimulated on 12 consecutive days with pulsed ultrasound and the effects of the sonication were evaluated through morphologic and morphometric techniques. Our findings suggest that sonication leads to a rapid regeneration of the nerve after axotomization. These affirmations are based on the counting of different types of fibre components in mixed nerves and the morphologic recovery of the same in comparasion with nerves of animals submitted to sham operation.
189

Análise histológica em tecido epitelial sadio de ratos Wistar (in vivo) irradiados com diferentes intensidades do ultra-som / Histological analyses in healthy epithelium tissue irradiated with different ultrasound intensities in Wistar rats in vivo

Daiane Müller de Bem 12 December 2008 (has links)
A energia ultra-sônica é um dos recursos físicos amplamente utilizado e pesquisado nos tratamentos de fisioterapia e diagnósticos médicos. Sabe-se que diante de uma escassa literatura dos efeitos do ultra-som em tecidos sadios, muitos profissionais fisioterapeutas acabam realizando aplicações infundadas de métodos e parâmetros. O objetivo desta pesquisa foi avaliar possíveis alterações do tecido sadio in vivo de ratos Wistar irradiados com diferentes intensidades, analisando a histologia e morfometria. Foram utilizados 30 ratos da linhagem Wistar, distribuídos aleatoriamente em 5 grupos de 6 animais cada. Foi escolhida a região dorsal do lado direito para tratamento com área de 4 \'CM POT.2\'. O lado esquerdo serviu como controle em todos os grupos. O tratamento foi feito durante 4 dias com 2 minutos de irradiação. Para verificar a intensidade de saída, utilizou-se o dosímetro de precisão antes da aplicação do ultra-som em cada animal. Foi realizada uma análise histológica descritiva e morfometria por meio do software Image Tool. Como resultado pode-se observar um discreto infiltrado inflamatório e adelgaçamento das fibras da derme, principalmente dos grupos irradiados com 1.5 e 2 W/\'CM POT.2\'. Notou-se também um aumento na espessura da epiderme nas amostras dos animais irradiados quando comparado com o controle. Para avaliar os resultados quantitativos, utilizou-se como análise estatística ANOVA \"one way\" e o teste \"pos hoc\" de Tukey com nível de significância p < 0,01. Em 120 medidas da espessura da epiderme obtiveram-se diferenças significativas do grupo controle com os grupos irradiados com (1.0, 1.5 e 2.0 W/\'CM POT.2\'). Concluímos diante dos resultados que houve alterações no tecido sob ação do US nas doses maiores, o que nos alerta para possíveis implicações do uso do US em estética. / The ultrasound (US) energy is one of the resources widely used and researched in both physio-therapist treatment and in medical diagnosis. In front of a scarce literature about the US effects in healthy tissues, many professionals have carried out unfounded applications of methods and parameters. So, the aim of this research was evaluate, through the histology, possible alternations in healthy tissues of Wistar rats in vivo irradiated with different intensity, analyzing the qualitative and quantitative histological slides. We used 30 Wistar rats randomly distributed in 5 groups of animals each. The local chosen for receiving the treatment was the dorsal right side, whose area was 4 \'CM POT.2\'. The left side was used as control of the animal itself for all the groups. The rats underwent the treatment during 4 days exposed to 2 minutes of irradiation. In order to check the energy output, the precision dosimeter was used before US application in each animal. The histological slides were evaluated qualitatively in the microscope and quantitatively through the image tool software. The qualitative result shows a discrete inflammatory process with infiltration and atrophy dermis fibers, mainly in the groups with higher US dosage. In the quantitative aspect, we found epidermis thickness increased in the 1.5 and 2 W/\'CM POT.2\' of US, with statistical difference (ANOVA) compared to control. We conclude that US therapy can be dangerous with high dosage applied in the intact skin.
190

Desenvolvimento de guia de ondas ultra-sônicas para monitorar a osseointegração de implantes dentários / Development of ultrasonic waveguide for monitoring dental implant osseointegration

Marina Storani de Almeida 17 April 2007 (has links)
Os equipamentos dispóníveis para acompanhamento clínico de implantes dentários monitoram mudanças de estabilidade, mas não são capazes de quantificar o nível de osseointegração. A literatura mostra que a aplicação de ultra-som pulsado de baixa intensidade estimula o reparo de fraturas ósseas e o crescimento de tecido ósseo nos poros de implantes, indicando que um guia de onda ultra-sônico poderia ser usado tanto para monitorar o processo de osseointegração como também para diminuir o período de recuperação. Diversas dimensões e geometrias foram consideradas nas simulações dos guias ultra-sônicos, e o guia com formato degrau apresentou maior sensibilidade a mudanças na composição do meio que envolve o implante. Resultados obtidos por simulação sugerem que há uma relação linear entre a energia do sinal detectado e o grau de osseointegração. Foram realizados experimentos com guias de onda de titânio e alumínio, sendo necessário realizar mais testes com guias de dimensões reduzidas para a obtenção de um dispositivo adequado para uso clínico. / Available equipments for clinical assessment of dental implants monitor changes in stiffness but are not able to quantify the osseointegration level. Literature shows that the application of low-intensity pulsed ultrasound stimulates the healing of bone fractures and the bone ingrowth into implants pores, indicating that an ultrasonic waveguide could be used to monitor the osseointegration process as well as to shorten the healing period. Several dimensions and geometries were considered in the waveguides simulations, and the step-shaped waveguide showed more sensibility to changes in the surrounding media of the implant. Results obtained by simulation suggest there is a linear relation between the energy of the detected signal and the osseointegration level. Experiments with titanium and aluminum waveguides were conducted, being necessary to carry out more studies with reduced size waveguides in order to obtain a suitable device for clinical use.

Page generated in 0.1138 seconds