• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 662
  • 22
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 707
  • 361
  • 97
  • 88
  • 75
  • 72
  • 64
  • 56
  • 50
  • 46
  • 41
  • 41
  • 39
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Estudo comparativo de duas técnicas de enxerto autógeno utilizando piezocirurgia para levantamento de seio maxilar / Comparative study of two autogenous graft techniques using piezosurgery for sinus lifting

Camargo Filho, Geraldo Prestes de 28 May 2010 (has links)
A técnica de levantamento de seio maxilar apresenta como uma possível complicação a perfuração da membrana sinusal. A utilização de dispositivos ultrassônicos apresenta-se como uma interessante ferramenta, particularmente segura e eficiente para realização das ostectomias de parede sinusal e divulsão de membrana sinusal. O presente trabalho teve por objetivo comparar duas técnicas que utilizam a cirurgia ultrassônica para realização de enxerto autógeno para levantamento de seio maxilar. Dez coelhos foram utilizados no estudo, sendo que um deles não foi submetido a procedimento cirúrgico. Os nove coelhos operados tiveram os seios maxilares preenchidos com enxertos autógenos coletados de díploe externa de calota craniana, nas formas particulado do lado direito e raspado do lado esquerdo, ambos com aparelho ultrassônico. Os dados de densidade óssea nos seios maxilares esquerdo e direito, obtidos por meio de tomografia computadorizada nos sentidos transversal e longitudinal, registrados 90 dias após a realização dos enxertos foram comparados estatisticamente. Cortes histológicos das áreas enxertadas foram realizados com finalidade descritiva. Não houve diferenças estatisticamente significantes entre as técnicas de enxerto que utilizaram osso raspado e particulado coletado por meio de dispositivo ultrassônico da calota craniana de coelhos. O aspecto histológico observado após 90 dias foi semelhante nos dois grupos, mostrando tecido ósseo maduro em meio a tecido conjuntivo frouxo. Os procedimentos transoperatórios nos levaram a concluir que o ultrassom piezoelétrico mostrou-se um instrumento seguro na abordagem cirúrgica do seio maxilar de coelhos, permitindo a manutenção da integridade da membrana sinusal durante as manobras cirúrgicas. / Maxillary sinus lifting is a technique which presents as a possible complication the sinus membrane perforation. The use of ultrasonic devices is presented as an interesting tool, particularly safe and efficient to perform ostectomies of sinus wall and dissection of sinus membrane. This study aimed to compare two techniques that used ultrasound surgery to perform autogenous graft for maxillary sinus lifting. Ten rabbits were used in the study, one of which did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were compared statistically. Histological sections of the grafted areas were performed with descriptive purposes. There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device of the skull of rabbits. Histological aspects after 90 days were similar in both groups, showing mature bone through a fibrous connective tissue. Operatory assessment procedures leads us to conclude that the piezoelectric ultrasound showed as a safe tool in the surgical approach of the maxillary sinus of rabbits, allowing the maintenance of sinus membrane integrity during surgical procedures.
92

Phantom antropomórfico para treinamento de biópsia de tireoide guiada por ultrassom / Anthropomorphic phantom for training of ultrasound-guided biopsy

Grillo, Felipe Wilker 30 September 2015 (has links)
O câncer de tireoide é um dos mais comuns da região da cabeça e pescoço. Atualmente, o método mais eficaz no diagnóstico de lesões da tireoide é a técnica de biópsia conhecida por punção aspirativa por agulha fina (PAAF) guiada por ultrassom. As imagens de ultrassom são utilizadas como guia para inserção de uma agulha fina até a região da lesão, onde são retirados fragmentos de tecido para análise microscópica. O sucesso dos procedimentos de biópsias está diretamente ligado a experiência do médico desde guiar a agulha à lesão até a preparação das lâminas para análise microscópica. O treinamento médico proporciona, durante a realização dos procedimentos, maior confiança ao médico e maior conforto ao paciente. No entanto o número de pacientes disponíveis, bem como o estágio de graduação do profissional, limitam o número de treinamentos realizados. Com base nessas limitações, esse estudo teve por objetivo o desenvolvimento de um phantom de tireoide permitirá que os treinamentos sejam realizados em qualquer horário e local, minimizando a responsabilidade de alunos e professores. Phantoms para ultrassom, geralmente, são corpos de prova construídos para mimetizar propriedades mecânicas e acústicas dos tecidos biológicos que podem ser utilizados no treinamento de habilidades médicas. Para o desenvolvimento deste modelo, utilizou-se um material a base de hidrocarbonetos de cadeia longa com diferentes concentrações de agentes contraste (pó de vidro, cera de carnaúba, parafina granulada, borracha de silicone). Caracterizou-se amostras de diferentes composições com relação ao módulo elástico, velocidade e atenuação da onda ultrassônica, de modo à atingir valores próximos aos encontrados na literatura para as regiões a serem mimetizadas. Obteve-se valores entre 1385 e 1480 m/s, para velocidade; valores entre 0,4 e 4 dB/cm para atenuação; e uma faixa entre 40 e 750 kPa para o módulo elástico. Ao final da caracterização dos materiais, obteve-se um phantom morfológico de pescoço, contendo a mimetização da tireoide para procedimentos de biópsia de tireoide guiada por ultrassom. / The thyroid cancer is one of the most common of head and neck region. Currently, the most effective method in the diagnosis of thyroid lesions is biopsy technique, known by fine-needle aspiration (FNA) guided by ultrasound. Ultrasound images guides the fine needle insertion into the lesion for sampling and then examined under a microscope. The medical training provides greater confidence to physician and comfort to patient. However, the number of available patients as well as the doctor degree stage limit the number of trainings conducted. Therefore, this study aimed to develop a thyroid phantom to training everywhere at any time, minimizing the students and teachers responsibilities. Ultrasound Phantoms mimics mechanical and acoustic properties of biological tissue and can be used for medical training. To develop the phantom we used a hydrocarbon-based material with different concentrations of contrast agents (glass powder, Carnauba wax, paraffin wax and silicone rubber). We calculated the elastic modulus, velocity and ultrasonic wave attenuation of different mixtures to reach values, as close the literature as possible. Was obtained values from 1385 to 1480 m / s for ultrasound velocity, values from 0.4 to 4 dB/cm for attenuation and a range from 40 to 750 kPa for elastic modulus. This study present an anthropomorphic neck phantom containing the necessary structures for training ultrasound guided biopsy by fine-needle aspiration.
93

Aplicação do transdutor magnetoacústico em estudos gástricos: in vitro e in vivo / Magnetoacústico transducer application in gastric studies: in vitro and in vivo.

Bruno, Alexandre Colello 23 January 2015 (has links)
A proposta deste trabalho foi desenvolver e avaliar as aplicações do transdutor magnetoacústico, em estudos in vitro e in vivo como ferramenta para o diagnóstico clínico, inicialmente para a análise de motilidade gastrintestinal. Na primeira etapa, a intensidade do campo magnético foi mapeada e ajustada, o melhor processamento para os dados foi definido e a viabilidade do uso de nanopartículas como marcadores foi contatada. Nos estudos in vivo, realizados em ratos, avaliou-se o potencial do transdutor híbrido para análise do esvaziamento gástrico, de alimentos marcado com partículas magnéticas, comparando os dados susceptométricos (padrão ouro) com os acústicos. O esvaziamento foi relacionado com a variação de área do estômago no tempo, que foi demarcada nas imagens de ultrassom usando a vibração das partículas como contraste. Outras variações e aplicações da ultrassonografia magnetomotriz foram investigadas, usando a excitação magnética pulsada (antes harmônica), aumentando a taxa de aquisição das imagens e gerando imagens elastográficas em fantomas. A produção e detecção de Shaer Waves (elastografia absoluta) também foi avaliada em outros fantomas com uma esfera de ferrita, sem e com uma inclusão mais rígida. A ultrassonografia magnetomotriz pulsada e o processamento vinculado a ela foram capazes de gerar as shear waves, através de puxões magnéticos na esfera de ferrita, e estimar a velocidade de propagação dessas. Com esta velocidade, estimaram-se os coeficientes elástico e viscoso dos meios de propagação. Portanto, o transdutor magnetoacústico, avaliado de diversas formas nesse trabalho, apresentou-se como uma potencial ferramenta para diagnóstico da motilidade gástrica in vivo, usando tanto a ultrassonografia magnetomotriz harmônica como a pulsada. As técnicas de processamento podem ser convencionais (modos Doppler, Power Doppler e elastográficos) ou dedicadas, as quais podem detectar deslocamentos, deformações ou propagação de ondas sísmicas; suas aplicações não se limitam ao estômago e nem os diagnósticos in vivo. / The aim of this study was to develop and to evaluate applications magneto-acoustic transducer in phantoms and in vivo studies, as a tool for clinical diagnosis, initially for analysis of gastrointestinal motility. First step, the magnetic field intensity was adjusted and mapped; the best data and image processing was defined, and nanoparticles markers were studied to future applications. In experiments with rats (in vivo), we evaluated the hybrid transducer potential by gastric emptying analysis using foods labeled magnetic particles, comparing the susceptometric data (gold standard) with the acoustic. Others magneto motive ultrasonography variations and applications were investigated. The variations were the pulsed magnetic excitation and the high frame rate. The rats empty gastric were evaluated with solid and liquid food by pulsed magneto-motive ultrasound; the solid food took longer to leave the stomach, as was expected. Other applications based on the use of elastography techniques combined with pulsed magneto-motive ultrasound in phantoms were evaluated - the first potential application was the lesions detection in the colon wall (by elastography relative). In this case, harder inclusions were located by elastography based on deformations caused by the magnetic pulse and by the magnetic fluid inserted in the supposed colon. The second potential application was Shear Waves production and detection (Transient elastography) using a ferrite sphere inside the phantoms with a harder inclusion. The pulsed Magneto Motive Ultrasound was able to generate shear waves by magnetic \"pushes\" in the ferrite sphere and it estimated the speed propagation of these. Therefore, the Magneto-Acoustic transducer showed that it is a potential tool for gastric motility diagnosis in vivo, using the harmonic or pulsed Magneto-Motive Ultrasound. Their processing techniques can be conventional (Doppler, Power Doppler and elastography modes), or dedicated to detect displacements, strains and seismic waves propagation, and its applications are not limited to stomach and in vivo diagnostics.
94

Aplicação do ultrassom para avaliação de cavidades intra-ósseas, em mandíbulas de porco / Application of ultrasound for evaluation of intraosseous cavities in pig jaw

Ferreira, Thásia Luiz Dias 23 March 2010 (has links)
O ultrassom é rotineiramente utilizado para avaliação de tecidos moles, contudo é um método que possui características importantes para avaliação não somente destes tecidos, mas dos ósseos também, além de possuir recursos diferenciais que auxiliariam muito no planejamento do tratamento e do prognóstico; embasados nessa premissa analisamos a possibilidade de avaliação de alterações intra-ósseas, por meio do ultrassom. A amostra foi constituída por cinco mandíbulas de porco, maceradas, e avaliadas nas regiões dos terceiros molares (tanto do lado direito quanto do esquerdo, totalizando 10 avaliações), por possuírem nessa região uma cripta óssea expressiva, o que simularia uma lesão intra-óssea. Para as avaliações ultrassonográficas dois grupos de três observadores foram formados, sendo um de CirurgiõesDentistas (Radiologistas) e outro de Médicos (Ultrassonografistas), os quais avaliaram, individualmente, a facilidade de visualização da imagem obtida por meio da ultrassonografia, bem como também o grau de translucidez do osso. Sendo que 46,6% das avaliações feitas pelos Cirurgiões-Dentistas foram ponderadas como de fácil visualização, 13,3% foram considerados de média dificuldade para avaliação, contra 23,3% que foram classificadas como de difícil localização, contudo 16,6% não foram possíveis de serem observadas. Os médicos classificaram como de fácil visualização 43,3% das ultrassonografias avaliadas, 23,3% como de média dificuldade, 20% de difícil observação e não conseguiram visualizar em 13,3% da amostra. Após avaliar os resultados encontrados e embasados na revisão da literatura foi possível concluir que: é possível se avaliar cavidades intraósseas por meio da ultrassonografia, contudo, para isso é necessário que a cortical óssea, por onde o feixe de ondas ultrassônicas vai penetrar, esteja adelgaçada; o US é um método imaginológico de fácil execução e interpretação, uma vez que os Cirurgiões- Dentistas que não tinham acesso, nem familiaridade, com este recurso imaginológico, conseguiram não só utilizá-lo, mas também compreender suas imagens, contudo em um grau discretamente menor em relação ao grupo formado por Médicos Ultrassonografistas, o que pode ser justificado por uma maior experiência por parte desses profissionais; mais estudos devem ser conduzido a fim de se explorar mais os benefícios e as vantagens que o US pode oferecer na área Odontológica. / Ultrasound (US) is routinely used for evaluation of soft tissues; however it is a method that has important features to evaluate not only these tissues, but also hard tissues that could help in the treatment planning and prognosis. This study analyzed the possibility of evaluation of intra-osseous changes, by means of US; grounded in this premise. The sample consisted of five macerated pig jaws, and the third molars areas (both the right and the left, totaling 10 ratings) were evaluated as these regions have a significant bone crypt, which simulate an intra-osseous lesion. For ultrasound images assessments two groups of three observers were trained, one of dentists (Radiology specialists) and other of physicians (US specialists), which evaluated individually, the visualization of the image obtained by US, and also the translucency degree of the bone. Dentists have been considered 46.6% of the assessments of easy viewing; 13.3% were considered of medium difficulty; 23.3% were classified as very difficult, although 16.6% were not found. Physicians considered 43.3% of images of easy viewing; 23.3% were considered of medium difficulty; 20% were classified as very difficult, although 13,3% were not found. Based on this results and the literature findings, it is possible to conclude that US is a useful tool for assessment of intraosseus cavities, but cortical bone should be thin so the sound waves can penetrate. US is an imaging method easy to perform and interpret, as the dentists, who had no access or familiarity with US, could interpret its images, at a slightly lower level than the US specialists, which can be explained by greater experience by these professionals. More studies should be conducted in order to explore the potential benefits and advantages of US utilization in Dentistry.
95

Avaliação do uso da ultrassonografia modo B para exploração através de tecido ósseo de costelas bovinas / Evaluation of the use of ultrasound B-mode exploration through bone beef ribs

Abreu, Marcos Petto Nunes de 30 July 2012 (has links)
O uso da ultrassonografia, para diagnóstico, como forma de exame complementar na área da Saúde é cotidiano e consagrado, principalmente no estudo e avaliação das doenças em tecidos moles. Com a consolidação e o desenvolvimento deste método, novos usos vem sendo descritos. Existem relatos científicos da possibilidade do uso do ultrassom para avaliação de lesões no interior do tecido ósseo. Frente a esta alternativa, o presente estudo avaliou o uso da ultrassonografia para exploração através de tecido ósseo, de diferentes espessuras, com a utilização de um modelo laboratorial em costelas bovinas, definindo a espessura óssea cortical que permite a passagem do ultrassom. Primeiramente realizamos um ensaio experimental para definir a melhor metodologia para o estudo. O modelo laboratorial usado era constituído por uma costela bovina, macerada, desgastada em diferentes espessuras. A amostra do estudo foi constituída em 180 leituras de ultrassom provenientes de 20 costelas bovinas maceradas; onde cada uma delas foi examinada em 9 áreas que se diferenciavam na espessura do remanescente ósseo; assim definidas 4,0mm, 3,0mm, 2,5mm, 2,0mm, 1,5mm, 1,0mm, 0,5mm, 0,2mm e sem desgaste. Para os exames de ultrassom foi utilizado o aparelho de ultrassom portátil Terason t3000 (Terason, divisão da Teratech Corporation, USA). Os exames foram realizados pela técnica da imersão, onde se mergulhava os espécimes e o transdutor do ultrassom em um recipiente com água. Para avaliar se havia ou não passagem da onda de ultrassom pelo tecido ósseo, em uma determinada espessura, era observada a formação de imagem de um objeto metálico posicionado atrás do osso. Conforme observado pela tabulação dos resultados ocorreu a passagem das ondas de ultrassom através do osso de espessuras 2,0mm, 1,5mm, 1,0mm, 0,5mm e 0,2mm diferentemente do ocorrido nas espessuras 4,0mm, 3,0mm, 2,5mm e sem desgaste. Houve diferença estatisticamente significante (P<0,001) entre as espessuras menores ou iguais a 2,0mm e as espessuras maiores ou iguais a 2,5mm, quanto a formação de imagem ultrassonográfica de um objeto metálico posicionado atrás do tecido ósseo. Concluímos que houve possibilidade de utilização do exame de ultrassom na avaliação através do tecido ósseo de espessuras menores ou iguais a 2,0mm. / The use of ultrasound as a complementary examination in health diagnoses is something usual and well established, mainly in the study and evaluation of diseases in soft tissue. As the consolidation and development of this method ocourred, new uses for it has been described. There are scientific reports with the possibility of the use of ultrasound for the evaluation of lesions within the bone tissue. Faced with this alternative, the aim of the present study was to evaluate the use of ultrasound for exploration through the bone tissue of different thicknesses, using a laboratory model of beef ribs, so thath would be defined the minimum required thicknesses of cortical bone for passage of the ultrasound. First we conducted an experimental trial to determine the best methodology for the study. The laboratory model used consisted of beef ribs prepared in different thicknesses. The study sample consisted of 180 ultrasound readings from 20 macerated beef ribs, each of which was examined in 9 different areas defined as, no wear, 4.0 mm, 3.0 mm, 2.5 mm, 2.0 mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm in thicknesses of the remaining bone. For ultrasound scanning was used a portable ultrasound device, Terason t3000 (Terason, a division of Teratech Corporation, USA). The examinations were performed by the technique of immersion, where the specimens and the ultrasound transductor were immersed in a water tank. To assess whether there was passage of ultrasound waves by the bone tissue in a certain thickness, it was observed the occurrence of a image formation from a metallic object that was positioned behind the bone. As noted by tabulating the results, there was passage of ultrasound waves through the bone thickness 2.0mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm different from those occurred in thickness of 4.0mm, 3.0mm, 2.5mm and no wear. There was significant difference (P<0.001) between the thicknesses less than or equal to 2.0 mm and thickness greater than or equal to 2.5 mm, in the ultrasound imaging of a metallic object positioned behind the bone. We conclude that there was possibility of using the ultrasound examination in the evaluation through the bone thickness less than or equal to 2.0mm.
96

Determinação das propriedades elásticas de laminados compósitos carbono/epóxi pelo método de ultrassom por imersão. / Determination of elastic properties of carbon/epoxy composite laminates by immersion ultrasonic method.

Yamashita, Dan 20 October 2016 (has links)
Este trabalho tem o objetivo de determinar as constantes elásticas de laminados compósitos de carbono/epóxi através do método não destrutivo de ultrassom, utilizando a técnica da imersão. Foram implementados dois métodos de imersão em água para a determinação das constantes elásticas. Um que utiliza o percurso na água sem a amostra como referência (FRM), e outro que utiliza o percurso com incidência normal na amostra como referência (SRM). Laminados unidirecionais e biaxiais foram ensaiados em um goniômetro com elevada precisão de movimento angular, e a aquisição de sinais feita com alta taxa de amostragem e grande resolução de amplitude. Uma análise da influência da variação da temperatura e espessura foi feita e comprovada a superioridade do método SRM sobre o FRM. A compensação da temperatura através de um par de transdutores, bem como através de um termômetro com resolução de 0.01°C foi implementada e comparada. As curvas de velocidade foram obtidas com transdutores de diferentes frequências centrais e comparadas. Foi realizada uma análise detalhada da sensibilidade das constantes elásticas com relação as velocidades em cada plano de medição, e através desta análise foram utilizados os planos mais adequados para reconstrução das constantes elásticas. Também foi verificada a polarização das ondas de cisalhamento para cada plano de medição, uma vez que é necessária a correta associação da velocidade experimental com a velocidade calculada para o procedimento de otimização. Um algoritmo de otimização foi utilizado para reconstruir as constantes elásticas dos laminados compósitos a partir da medição experimental das velocidades, onde foi avaliada a convergência utilizando a equação de Christoffel na forma implícita e explícita, para os materiais de simetria tetragonal e hexagonal. / The objective of this work is to obtain the elastic constants of carbon/epoxy composite laminates using ultrasonic non destructive testing, with immersion technique. Two immersion methods were implemented. One method uses as reference the path without sample, called fluid reference method (FRM), the second method uses the path with the specimen in normal incidence, called self-reference method (SRM). Unidirectional and biaxial laminates were tested using a goniometer with high angular resolution, and the signals were acquired with a high sample rate and amplitude resolution. Analyses of the influence of temperature and thickness variations were performed and concluded the superiority of the SRM over the FRM method. Temperature compensation using a pair of transducers and a 0.01° resolution thermometer was implemented and compared. Velocity curves were obtained and compared using transducers with different frequencies. A detailed analysis was performed to evaluate the sensitivity of the elastic constants to each velocity in different acquisition planes, and the results were used to reconstruct the elastic constants in the planes/velocities which they were most sensible to. As the correct association of each experimental velocity with the calculated velocities from Christoffel\'s equation is necessary, an analysis of the polarization mode of each velocity in the acquisition planes was also performed. An optimization algorithm was used to reconstruct the elastic constants of composite laminates from experimental velocities. Its convergence was evaluated for the implicit and explicit form of Christoffel\'s equation, and for materials with tetragonal and hexagonal symmetry.
97

Efeito da irrigação e medicação endodôntica em dentina infectada por biofilmes orais

Zapata, Ronald Ordinola 07 June 2013 (has links)
O objetivo desse estudo foi avaliar o efeito antimicrobiano da irrigação e da medicação endodôntica em dentina infectada por biofilmes orais. Na primeira parte do estudo, avaliaram-se as seguintes soluções irrigadoras: hipoclorito de sódio a 1%, clorexidina a 2%, ácido cítrico a 10% e EDTA a 17%. Na segunda parte, avaliaram-se soluções irrigadoras contendo associações (MTAD, Smear Clear, Qmix, ácido maleico a 7%, iodo-iodeto de potássio a 2% e ácido peracético a 4%), sendo essas soluções comparadas a 2 concentrações de hipoclorito de sódio. Na terceira parte, avaliou-se o efeito de dispositivos sônicos, ultrassônicos e de laser na capacidade de limpeza do hipoclorito de sódio a 6%, com uso de microscópio eletrônico de varredura. Na quarta parte, avaliaram-se os efeitos antimicrobianos de 3 pastas de hidróxido de cálcio contendo 3 radiopacificadores diferentes (óxido de zinco, sulfato de bário e iodofórmio). No último experimento, foram avaliadas as propriedades antimicrobianas da pasta triantibiótica, da clorexidina em gel e da pasta aquosa de hidróxido de cálcio. Os resultados mostraram que todas as soluções de hipoclorito de sódio testadas e o ácido peracético a 4% foram mais efetivas sobre o biofilme em comparação a todos os irrigantes testados. As soluções de hipoclorito de sódio propiciaram significativamente uma melhor limpeza da dentina. O ácido peracético foi também efetivo para dissolver células do biofilme. A ativação do hipoclorito de sódio com o ultrassom e com laser interferiu favoravelmente na limpeza da dentina infectada. A pasta triantibiótica e o hidróxido de cálcio associado ao iodofórmio foram os medicamentos mais efetivos na descontaminação da dentina infectada. Portanto, o protocolo ideal que deve ser adotado para garantir uma descontaminação efetiva da dentina contaminada por biofilmes orais inclui o uso de hipoclorito de sódio ativado por ultrassom ou laser e medicação intracanal de hidróxido de cálcio com iodofórmio. O ácido peracético e a pasta triantibiótica apresentaram resultados promissores. / The aim of this study was to evaluate the antimicrobial effect of endodontic irrigation and medication on biofilm infected dentin. In the first part, we evaluated the following irrigant solutions: 1% sodium hypochlorite, 2% chlorhexidine, 10% citric acid and 17% EDTA. In the second part, irrigant solutions containing combinations of antimicrobials such as \"MTAD,\" \"Smear Clear\", \"Qmix\", 7% maleic acid and 2% iodine-potassium iodide and 4% peracetic acid were evaluated. These solutions were compared to 2 concentrations of sodium hypochlorite. In the third part, we evaluated the effect of sonic, ultrasonic and laser irrigation on the cleaning ability of biofilm infected dentin using 6% sodium hypochlorite under scanning electron microscope. In the fourth part, we evaluated the antimicrobial effects of 3 calcium hydroxide pastes containing 3 different radiopacifiers (zinc oxide, barium sulfate and iodoform). In the last experiment, we evaluated the antimicrobial properties of the triantibiotic paste, 2% chlorhexidine gel and calcium hydroxide paste. The results showed that the sodium hypochlorite and the peracetic acid solutions were more effective to decontaminate the biofilm infected dentin in comparison to all of the tested irrigants. The sodium hypochlorite solutions allowed significantly better cleaning of the dentine. The peracetic acid was also effective to dissolve the biofilm cells. Activation of 6% sodium hypochlorite with ultrasonic and laser increased the cleaning of biofilm infected dentin. The triantibiotic paste and calcium hydroxide associated to iodoform were the most effective intracanal dressings available for the decontamination of the infected dentin. Therefore, the ideal protocol to be adopted in order to ensure an effective decontamination of biofilm infected dentin includes the use of sodium hypochlorite, specially activated by ultrasound or laser; and the use of calcium hydroxide with iodoform intracanal dressing. The peracetic acid and the triantibiotic paste also showed promising results.
98

Avaliação das soluções irrigadoras da \"smear layer\" nos diversos níveis do conduto radicular com e sem o uso do ultra-som: estudo em microscopia eletrônica de varredura / Evaluation of irrigating solutions on smear layer removal at different levels of root canal with and without ultrasonics: a scanning electron microscopic study

Rodrigues, Clarissa Teles 27 May 2011 (has links)
Este estudo teve como objetivo avaliar a capacidade de remoção da smear layer das paredes de canais radiculares instrumentados pelas soluções de soro fisiológico, EDTA a 17%, vinagre de maçã e SmearClear®, nos três níveis radiculares, associadas ou não ao ultra-som. Para tal propósito, foram utilizados 70 dentes caninos humanos superiores e inferiores extraídos os quais tiveram suas coroas removidas. O comprimento de trabalho foi determinado pela visualização da ponta de uma lima tipo K com diâmetro 10 no forame apical, subtraindo-se 1 milímetro dessa medida. Para o preparo biomecânico, instrumentou-se os dentes com o sistema rotatório ProTaper®, pela técnica coroa-ápice, até o instrumento F5, irrigando os canais com hipoclorito de sódio a 2,5% a cada troca de instrumento. Os dentes foram divididos aleatoriamente em 6 grupos de 10 dentes e 2 grupos controle de 5 dentes de acordo com o método de irrigação final a serem testados: Grupo 1 (controle) Soro fisiológico por 3 minutos sem ultra-som; Grupo 2 - (controle) Soro fisiológico por 3 minutos, sendo o primeiro minuto ativado pelo ultra-som; Grupo 3 - EDTA a 17% por 3 minutos sem ultra-som; Grupo 4 - EDTA a 17% por 3 minutos, sendo o primeiro minuto ativado pelo ultra-som; Grupo 5 - Vinagre de maçã por 3 minutos sem ultra-som; Grupo 6 - Vinagre de maçã por 3 minutos, sendo o primeiro minuto ativado pelo ultra-som; Grupo 7 - SmearClear® por 1 minuto sem ultra-som; Grupo 8 - SmearClear® por 1 minuto ativado pelo ultra-som. Em seguida, os dentes foram irrigados com hipoclorito de sódio a 2,5% e soro fisiológico e secos com cones de papel absorvente. As raízes foram seccionadas longitudinalmente e preparadas para a microscopia eletrônica de varredura com o aumento de 750 vezes. Fotomicrografias foram obtidas dos terços cervical, médio e apical e analisadas por três examinadores para a atribuição de escores para posterior análise estatística. Concluiu-se que as soluções de EDTA e SmearClear® foram efetivas na remoção da smear layer do canal radicular, com pequena vantagem numérica do EDTA, entretanto, sem diferença estatisticamente significante entre elas. O soro fisiológico apresentou resultado significativamente inferior comparado às demais soluções irrigadoras. O vinagre de maçã se mostrou ligeiramente inferior ao SmearClear® e ao EDTA, apresentando diferença estatisticamente significante ao EDTA no terço cervical. O uso do ultra-som não promoveu uma melhora significante na capacidade de limpeza de todas as soluções irrigadoras testadas. Em todos os grupos, o resultado menos favorável em relação à remoção da camada de smear layer foi observado no terço apical do canal radicular, com diferença estatisticamente significante em relação ao terço cervical. / The aim of this study was to evaluate the smear layer removal from instrumented root canal walls by saline solution, 17% EDTA, apple vinegar and SmearClear®, at three radicular levels, with or without ultrasonics. For that purpose, 70 upper and lower human canines were used, which had their crowns removed. The working length was established by visualizing the tip of a 10 K-type file at the apical foramen, by reducing 1 mm from this measurement. For preparation of root canal, the teeth were instrumented with rotatory files ProTaper®, using the crown-down technique, up to F5 instrument, irrigating with 2,5% sodium hypochlorite between each instrument change. The teeth were randomly divided into 6 groups of 10 teeth each and 2 control groups of 5 teeth according to the final irrigation protocol: Group 1 (control) Saline solution for 3 minutes without ultrasonics; Group 2 (control) Saline solution for 3 minutes, with ultrasonic activation for the first minute; Group 3 17% EDTA for 3 minutes without ultrasonics; Group 4 17% EDTA for 3 minutes, with ultrasonic activation for the first minute; Group 5 Apple vinegar for 3 minutes without ultrasonics; Group 6 Apple vinegar for 3 minutes, with ultrasonic activation for the first minute; Group 7 - SmearClear® for 1 minute without ultrasonics; Group 8 - SmearClear® for 1 minute with ultrasonic activation. Subsequently, the teeth were irrigated with 2,5% sodium hypochlorite and dried with paper points. The teeth were split open longitudinally and prepared for scanning electron microscopy at magnification of 750X. Photomicrographs were taken from coronal, middle and apical thirds and analyzed by three examiners for scores attribution for statistical analysis. It was concluded that EDTA and SmearClear® were efficient for smear layer removal from root canals, with a discrete superiority of EDTA, however, without statistical significance. The saline solution showed significant inferior results compared with the others solutions. Apple vinegar was slightly inferior to SmearClear® and EDTA, with statistical difference observed between apple vinegar and EDTA in coronal third. The ultrasonics did not enhance the cleaning ability of all the irrigating solutions tested. In all cases, the least favorable result regarding smear layer removal was observed in the apical third of the root canal, with statistically significant differences in the coronal third.
99

Avaliação da aplicabilidade da ultrassonografia musculoesquelética do segmento toracolombar e lombar da coluna vertebral de cães hígidos / Evaluation of the applicability of musculoskeletal ultrasound of the thoracolumbar and lumbar spine of healthy dogs

Lopes, Érika Rondon 15 June 2016 (has links)
Alterações na coluna vertebral de cães são comumente encontradas na rotina clínica e cirúrgica veterinária. Existem poucos estudos sobre a anatomia ultrassonográfica musculoesquelética do segmento toracolombar e lombar da coluna vertebral normal de cães. O objetivo deste trabalho foi comparar a anatomia ultrassonográfica musculoesquelética normal dos segmentos vertebrais avaliados com imagens obtidas pela ressonância magnética, tomografia computadorizada e peças anatômicas visando demonstrar a sua capacidade de identificação de estruturas. A varredura ultrassonográfica permitiu a visibilização da musculatura da região, processos articulares, processos espinhosos, ligamentos interespinhosos e ligamento amarelo na janela lombossacra. A tomografia computadorizada forneceu imagens com melhor detalhamento ósseo quando comparada ao exame ultrassonográfico. A ressonância magnética de baixo campo permitiu a identificação das mesmas estruturas que o exame ultrassonográfico acrescido da identificação do líquido cefalorraquidiano, processos transversos e melhor detalhamento dos discos intervertebrais e medula espinhal. Com o conhecimento da anatomia ultrassonográfica da região, acredita-se que lesões musculares e ligamentares possam ser identificadas. Vale salientar que em regiões onde a tomografia computadorizada e a ressonância magnética não estejam acessíveis a ultrassonografia da região pode ser uma boa alternativa para identificar possíveis alterações não visibilizadas ao exame radiográfico, ou complementar o mesmo. / Changes in the spine of dogs are usually found in clinical and surgical practices. There are few studies on musculoskeletal ultrasound anatomy of thoracolumbar and lumbar segments of the normal spine of dogs. The aim of this study was to compare normal musculoskeletal ultrasound anatomy of the vertebral segments evaluated with images obtained by magnetic resonance imaging, computed tomography and anatomical parts in order to establish its ability to identify structures. The ultrasound scan allowed visualization of the muscles of the region, articular processes, spinous process, interspinous ligament and yellow ligament in the lumbosacral window. Computed tomography provide images with better bone details when compared to ultrasound examination. Low field magnetic resonance imaging allowed the identification of the same structures as the ultrasound examination plus the identification of cerebrospinal fluid, transverse processes and better detail of the intervertebral discs and spinal cord. Knowledge of ultrasound anatomy of the region may lead to detection of muscle and ligament injuries. It is emphasized that in areas where CT and MRI are not accessible, ultrasonography of the region can be a good alternative to identify possible alterations not visualized by radiographic examination or supplement it.
100

Aplicabilidade da ultrassonografia musculoesquelética na articulação do cotovelo de cães hígidos / Applicability of musculoskeletal ultrasound in the elbow joint of healthy dogs

Bellegard, Gabriela Monaldo Corrá 14 December 2016 (has links)
A articulação do cotovelo é complexa e tem grande relevância clínica nos atendimentos aos pequenos animais. Esta região já foi bem explorada em pesquisas anteriores pelos métodos radiográficos e tomográficos, porém, ainda há poucos estudos relacionados à ultrassonografia. O objetivo deste estudo foi descrever a anatomia ultrassonográfica da articulação do cotovelo de cães e comparar com os achados das demais modalidades de diagnóstico por imagem. Dessa forma, demonstrar a capacidade da técnica de identificar as principais estruturas desta articulação e seu potencial uso em regiões onde a tomografia computadorizada e ressonância magnética não estiverem disponíveis. Dez animais com peso entre 5 kg e 15 kg foram radiografados e selecionados para o estudo ultrassonográfico. O protocolo para a descrição ultrassonográfica foi estabelecido dividindo-se as áreas da articulação em porções proximal, média e distal; e faces lateral, cranial, medial e caudal. A avaliação foi realizada nos planos longitudinais, transversais e oblíquos e as estruturas musculoesqueléticas foram descritas conforme sua arquitetura, ecogenicidade e ecotextura. Como parte complementar deste estudo um dos animais foi submetido aos exames de tomografia computadorizada e ressonância magnética. Em relação às estruturas visibilizadas, o exame ultrassonográfico foi eficiente para as análises muscular, tendínea e ligamentar. Os contornos ósseos e regiões sede de alterações de importância clínica, como processo coronóide medial da ulna e processo ancôneo também foram visibilizados, porém de forma limitada. O conhecimento prévio da anatomia ultrassonográfica normal da articulação do cotovelo, assim como das vantagens e limitações da técnica, permitem a realização de estudos subsequentes, relacionados às possíveis identificações de alterações musculoesqueléticas. / The elbow is a complex joint and has a great clinical relevance at the small animal medicine care. Previous research of this region has been explored using radiographic and tomographic methods, however, there are few studies related to ultrasonography. The aim of this study was to describe the ultrasonographic anatomy of the elbow joint of dogs and compare it with the findings of other types of diagnostic imaging. Thus, demonstrate the ability of this technique to identify the main structures of this joint and its potential use in regions where computed tomography and magnetic resonance imaging are not available. Ten animals weighing between 5 kg and 15 kg were radiographed and selected to the ultrasonographic study. The protocol was established for the ultrasonographic description dividing the articular areas in proximal, middle and distal; and lateral cranial, medial, and caudal faces. The approach was made in longitudinal, transverse and oblique planes and the musculoskeletal structures were described according to the architecture, echogenicity and echotexture. Computed tomography and magnetic resonance scans were made in one animal as an additional part of this study. Regarding visualized structures, the ultrasonography was efficient for muscle, tendon and ligament analysis. Bone contours and regions that have clinical significance such as medial coronoid process and anconeus process were identified, but with limited access. Prior knowledge of the normal sonographic anatomy of the elbow joint as well as the technical advantages and limitations allow pursuing further studies related to the possible identification of musculoskeletal disorders.

Page generated in 0.0935 seconds