• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 662
  • 22
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 707
  • 361
  • 97
  • 88
  • 75
  • 72
  • 64
  • 56
  • 50
  • 46
  • 41
  • 41
  • 39
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Estudo da intensificação da coalescência de emulsões de água em óleo com a aplicação de onda estacionária de ultrassom. / Study of the intensifying water in oil emulsions coalescence with the application of ultrasonic standing wave.

Atehortua, Carlos Mario Giraldo 14 August 2015 (has links)
Considerando que o petróleo quando extraído dos poços em águas profundas chega a ter teor de água superior a 50% e que antes de ser enviado à refinaria deve ter uma quantidade de água inferior a 1%, torna-se necessário o uso de técnicas de redução da quantidade de água. Durante a extração do petróleo formam-se emulsões de água em óleo que são muito estáveis devido a um filme interfacial contendo asfaltenos e/ou resinas ao redor das gotas de água. Nesse trabalho é apresentada a utilização de ondas estacionárias de ultrassom para realizar a quebra dessas emulsões. Quando gotículas de água com dimensões da ordem de 10m, muito menores que o comprimento de onda, são submetidas a um campo acústico estacionário em óleo, a força de radiação acústica empurra as gotículas para os nós de pressão da onda. Uma célula de coalescência com frequência central ao redor de 1 MHz, constituída por quatro camadas sendo uma piezelétrica, uma de acoplamento sólido, uma com o líquido e outra refletora, foi modelada empregando o método da matriz de transferência, que permite calcular a impedância elétrica em função da frequência. Para minimizar o efeito do gradiente de temperatura entre a entrada e a saída da cavidade da célula, quando está em operação, foram utilizados dois transdutores piezelétricos posicionados transversalmente ao fluxo que são excitados e controlados independentemente. Foi implementado um controlador digital para ajustar a frequência e a potência de cada transdutor. O controlador tem como entrada o módulo e a fase da corrente elétrica no transdutor e como saída a amplitude da tensão elétrica e a frequência. Para as células desenvolvidas, o algoritmo de controle segue um determinado pico de ressonância no interior da cavidade da célula no intervalo de frequência de 1,09 a 1,15 MHz. A separação acústica de emulsões de água em óleo foi realizada em uma planta de laboratório de processamento de petróleo no CENPES/PETROBRAS. Foram testados a variação da quantidade de desemulsificante, o teor inicial de água na emulsão e a influência da vazão do sistema, com uma potência de 80 W. O teor final de água na emulsão mostrou que a aplicação de ultrassom aumentou a coalescência de água da emulsão, em todas as condições testadas, quando comparada a um teste sem aplicação de ultrassom. Identificou-se o tempo de residência no interior da célula de separação como um fator importante no processo de coalescência de emulsões de água e óleo. O uso de desemulsificante químico é necessário para realizar a separação, porém, em quantidades elevadas implicaria no uso de processos adicionais antes do repasse final do petróleo à refinaria. Os teores iniciais de água na emulsão de 30 e 50% indicam que o uso da onda estacionária na coalescência de emulsões não tem limitação quanto a esse parâmetro. De acordo com os resultados obtidos em laboratório, essa técnica seria indicada como uma alternativa para integrar um sistema de processamento primário em conjunto com um separador eletrostático. / Considering that oil when extracted from the wells in deep water have water content greater than 50%, and that before to be sent to the refinery must have a quantity of water less than 1%, it becomes necessary to use water amount reduction techniques. During the oil extraction are formed water-in-oil emulsions that are highly stable due to an interfacial film containing asphaltenes and / or resins around the water droplets. This work presents the use of ultrasonic standing waves to perform that emulsion break. When water droplets with dimensions about 10m, much smaller than the wavelength, are placed in a standing acoustic field in oil, the acoustic radiation force pushes the water droplets to the pressure wave nodes. A coalescing chamber with frequency about 1 MHz, with four layers comprising a piezoelectric, a solid coupling, one with the liquid, and another reflector, was modeled using the matrix transfer method, that allows calculating the electrical impedance as a function of frequency. To minimize the effect of the temperature gradient between the inlet and the outlet of the chamber cavity, when it is operating, were used two groups of piezoelectric transducers positioned transverse to the flow which are excited and controlled independently. A digital controller has been implemented to adjust the frequency and the power of each transducer. The controller has as input the modulus and phase of electrical current of the transducer and as output the amplitude of voltage and the frequency. For developed cells, the control algorithm follows an specific resonance peak within the chambers cavity in the frequency range 1.09 to 1.15 MHz. Acoustic separation of water in oil emulsions was carried out on a laboratory oil processing plant. Tests were performed by varying the amount of the chemical demulsifier, the initial water content in the emulsion. The system flow rate was kept constant at 80 W using the control system. Residence time within the separation chamber was identified as an important factor in the water in oil emulsions coalescence process. The use of chemical demulsifier is required to perform the separation, however in large quantities, it implies the use of additional processes before the oil final transfer to the refinery. Initial water contents in the emulsion about 30 and 50% indicate that the use of the acoustic standing wave in the emulsion coalescence has not limitation on this parameter. According to the results obtained in laboratory, this technique would be indicated as an alternative to integrate a primary processing system together with an electrostatic separator.
102

An?lise do desempenho da ultrassonografia no imageamento n?o invasivo de dep?sitos sedimentares simulados em laborat?rio

Pires, J?lio C?sar Gall 20 January 2014 (has links)
Made available in DSpace on 2015-04-14T13:59:06Z (GMT). No. of bitstreams: 1 456914.pdf: 4300690 bytes, checksum: 4347bfbddc1c3238eb967996a15790e4 (MD5) Previous issue date: 2014-01-20 / In this study, the application of acoustic waves for imaging the internal architecture of sedimentary deposits produced in the simulation of different types of sediment tanks was investigated systematically. To do so we used two ultrasound imaging equipment medical and industrial, yielding two groups of images. The medical device (1.0<&#55349;&#56403;< 10 MHz) was employed to optimize detail and industrial equipment (0.1 < &#55349;&#56403;<1.0 MHz ) favors the penetration in thicker layers . The acoustic behavior (maximum depth of the signal propagation speed of sound and contrast) traditional materials used in experimental simulations (coal, sand and balotine) and new artificial sediments was studied using polymer-based composites. For analysis of such materials different arrangements which changed the topography, thickness and grain size of the sediment layers were created. The transducer frequency and settling time were also monitored in the trials. The results showed that the maximum depth of view in 5 MHz was not more than 2 cm for all materials used. For a frequency of 250 kHz the display area increases substantially more than 6 cm. Although the spatial resolution decreases with decreasing frequency, due to the dotted aspect (speckle) of ultrasound images of the deposits isn&#8223;t observed a significant loss of detail through the use of frequencies in the kHz range. The depth of view varied with particle size of pelleted material, being slightly higher in materials with larger grains. For particle sizes greater than 180 &#61549;m, there was obtained a maximum depth of view of the order of 1.27 cm to 1.10 cm coal 210 and to the sand. While for the polymer based composites of the same particle size range was obtained values around 0.7 cm. Materials with less than 180 &#61549;m tracks offered greater difficulty in spreading the signal beam, as the beam is reflected with high efficiency. The calculations of the propagation speed of the ultrasonic wave in the material revealed that by decreasing the particle propagation velocity in the sediment increases slightly. The value of the sound propagation velocity estimated to the coal 205 was 1989?74 m/s, while for coal 210 was 1705?45 m/s. In limestone, sand, balotine, RP , RPNF , GPMMA and PMMA particle size less than 180 &#61549;m was the Vp of the order of 1650 m/s . There were no changes of these values for the frequencies used, as expected, except for the fine sand at 250 kHz decreased by ~ 20 %. No significant differences were observed in the intensity of the sound signal between different materials. However, the spherical morphologies of balotine or rounded sand gave more intense signals and favor layers when the contrast between different materials, such as coal or polymer composites are used in neighboring layers. The particle size also influences the contrast, since larger grains favor the diffuse reflection, while the greater compaction of sediments smaller grains creates more favorable conditions almost specular reflection of greater intensity. Conventional materials used for imaging proved to be good for contrast as in the case of balotine and sand , coal and limestone but had become very reflective Furthermore, another drawback is the time of getting very high settling time suspension, which prevents / impairs its use in visual tests or ultrasound imaging . Artificial materials showed little difference in acoustic behavior of the test image but can be pigmented for visual tests in current density and have wide variations in behavior X-ray images due to changes in the concentrations of fillers added at the time of synthesis. In imaging by acoustic waves should, however, take into account problems such as reduced depth preview for clinical echographs and small visual area of the transducer, because the images can&#8223;t be used for analysis. One possibility for the application of this technique is to make successive images of the deposits in increments of low thickness (of the order of cm), with the same acquisition parameters. Thus each layer of material can be imaged independently and then grouped based on predetermined points of reference. Then through sequential imaging to reconstruct the global architecture of the sediment can be studied. The research of the internal architecture of sedimentary deposits produced in physical models employing acoustic waves for imaging revealed by the observation of material characteristics can estimate the presence of the layers that constitute it. To do this, find differences substances as particle size, particle morphology, speed of acoustic propagation in the material and density are of great importance and facilitate the analysis of a sample. / Neste trabalho a aplica??o de ondas ac?sticas para o imageamento de dep?sitos sedimentares produzidos em laborat?rio, com diferentes tipos de sedimentos, foi investigada sistematicamente. Para tanto, usou-se dois equipamentos de imageamento por ultrassom, um m?dico e um industrial, obtendo-se dois grupos de imagens. O equipamento m?dico (1,0<&#55349;&#56403; < 10 MHz) foi empregado para otimizar detalhes e o equipamento industrial (0,1 <&#55349;&#56403; < 1,0 MHz) favorece a penetra??o em camadas mais espessas. Foi avaliado o comportamento ac?stico (profundidade m?xima do sinal, velocidade de propaga??o do som e contraste) de materiais tradicionais usados em simula??es experimentais (carv?o, areia e balotine) e de novos sedimentos artificiais, utilizando comp?sitos de base polim?rica. Para an?lise dos materiais mencionados foram criados diferentes arranjos, onde se modificou a topografia, espessura das camadas e granulometria dos sedimentos. A frequ?ncia do transdutor e o tempo de sedimenta??o tamb?m foram controlados nos ensaios. Os resultados obtidos mostraram que a profundidade m?xima de visualiza??o em 5 MHz n?o foi superior a 2cm para todos os materiais utilizados. Para uma frequ?ncia de 250 kHz a zona de visualiza??o aumenta substancialmente para mais de 6 cm. Apesar da resolu??o espacial decrescer com a diminui??o da frequ?ncia, devido ao aspecto pontilhado (speckle) das imagens ultrassonogr?ficas dos dep?sitos, n?o se observa uma perda de detalhe significativa com o uso de frequ?ncias na faixa do kHz. A profundidade de visualiza??o variou em fun??o da granulometria do material sedimentado, sendo levemente maior em materiais com gr?os maiores. Para granulometrias maiores que 180 &#956;m, se obteve uma profundidade m?xima de visualiza??o da ordem de 1,27 cm para o carv?o 210 e 1,10 cm para a areia. Enquanto que para os comp?sitos de base polim?ricas da mesma faixa granulom?trica se obteve valores em torno de 0,7 cm. Os materiais com faixas menores que 180 &#956;m ofereceram maior dificuldade ? propaga??o do sinal do feixe, j? que o feixe ? refletido com grande efici?ncia. Os c?lculos de velocidade de propaga??o da onda ultrass?nica nos materiais revelaram que ao se diminuir a granulometria a velocidade de propaga??o no sedimento aumenta levemente. O valor de velocidade de propaga??o do som estimado para o carv?o 205 foi de 1989?74 m/s, enquanto para o carv?o 210 foi de 1705?45 m/s. No calc?rio, areia, balotine, RP, RPNF, GPMMA e PMMA com granulometria menor que 180 &#956;m a Vp foi da ordem de 1650 m/s. N?o houve mudan?as desses valores para as frequ?ncias utilizadas, como esperado, com exce??o para a areia fina que em 250 kHz apresentou uma redu??o de ~ 20%. N?o foram observadas diferen?as muito significativas na intensidade do sinal sonoro entre os diversos materiais. Contudo, as morfologias esf?ricas do balotine ou arredondadas da areia proporcionaram sinais mais intensos e favorecem o contraste entre camadas quando materiais distintos, como o carv?o ou os comp?sitos polim?ricos s?o usados em camadas vizinhas. A granulometria tamb?m influencia no contraste, j? que gr?os maiores favorecem a reflex?o difusa, enquanto a maior compacta??o de sedimentos de gr?os menores cria condi??es mais favor?veis a reflex?o quase especular de maior intensidade. Os materiais convencionais empregados para o imageamento revelaram-se bons para o contraste como ? o caso do balotine e da areia, mas o carv?o e o calc?rio apresentaram-se muito reflexivos, al?m disso, outro ponto negativo ? o tempo de sedimenta??o elevado ficando muito tempo em suspens?o, o que impossibilita/prejudica seu emprego em testes visuais ou imageamento ultrass?nico. Os materiais artificiais apresentaram pouca diferen?a de comportamento nos testes de imagem ac?stico, mas podem ser pigmentados para testes visuais em correntes de densidade e apresentam grandes varia??es de comportamento em imagens de raios x devido a mudan?as nas concentra??es de cargas adicionadas no momento da s?ntese. No imageamento por ondas ac?sticas deve-se, contudo, levar em conta problemas como a reduzida profundidade de visualiza??o para ec?grafos cl?nicos e a pequena ?rea visual do transdutor, pois as imagens podem n?o servir para an?lise. Uma possibilidade para a aplica??o dessa t?cnica ? fazer imagens sucessivas do dep?sitos com incrementos de espessura baixos (da ordem de cm), com os mesmos par?metros de aquisi??o. Assim cada camada de material pode ser imageada independentemente e depois agrupada com base em pontos de referencias pr?-estabelecidos. Ent?o atrav?s do imageamento sequencial a reconstruir da arquitetura global do sedimento pode ser estudada.
103

Força de radiação acústica produzida por ondas estacionárias de ultrassom. / Acoustic radiation force generated by ultrasound standing waves.

Ramos, Tiago dos Santos 28 September 2017 (has links)
O estudo da força de radiação acústica é de extrema importância para compreender o fenômeno da levitação acústica, tendo em vista que ela é que permite a levitação de objetos no interior de uma cavidade acústica. A cavidade acústica é uma região do espaço delimitada pelas faces de um transdutor e de um refletor, onde é produzida uma onda estacionária de alta intensidade. Nesta técnica, conhecida como levitação por ondas estacionárias, pequenos objetos são aprisionados nos nós de pressão da onda estacionária. Além desta, também existe uma outra técnica de levitação onde não há a necessidade de se utilizar um refletor, técnica conhecida como levitação de campo próximo, na qual se tem apenas um transdutor e o objeto de face plana que se deseja levitar. Nesta técnica há uma pequena região com ar entre o transdutor e o objeto, sendo que a espessura da camada de ar é muito menor que o comprimento de onda. Neste trabalho foi feito um estudo numérico e experimental da força de radiação acústica em levitadores acústicos de onda estacionária e em levitadores de campo próximo. As simulações foram realizadas no software de elementos finitos COMSOL Mutiphysics. No estudo experimental foi utilizada uma balança eletrônica para medir a força de radiação acústica e uma câmera de alta velocidade para observar o comportamento oscilatório de objetos esféricos no interior da cavidade acústica. O estudo da força de radiação acústica resultou em três principais contribuições. A primeira contribuição está relacionada com a caracterização de efeitos não lineares em um levitador acústico, como o fenômeno de salto (jump phenomenon) e o fenômeno de histerese. A segunda contribuição está relacionada com o estudo numérico e experimental da força de radiação acústica que atua no refletor de um levitador acústico. Por último também foi feito um estudo da força de radiação acústica que atua no refletor para a região do campo próximo. Neste último estudo foi verificado que quando o diâmetro da face do transdutor é pequeno em comparação com o comprimento de onda, surge uma força atrativa sobre o refletor, e esta força pode ser utilizada para levitar um objeto plano em baixo da face do transdutor, sem haver necessidade de utilizar refletores. / The study of the acoustic radiation force is of high relevance to understand the acoustic levitation, since it is responsible for the levitation of small objects in the interior of an acoustic cavity. The acoustic cavity is the region delimited by the surfaces of the transducer and the reflector, where it is generated an acoustic standing wave field of high intensity. In this technique, called standing wave acoustic levitation, small objects are entrapped at the pressure nodes of the standing wave. In addition, there is also another levitation technique where there is no need to use a reflector. This technique is known as near-field levitation, in which there is only one transducer and the flat-faced object to be levitated. In this technique there is a small region with air between the transducer and the object, with the thickness of the air layer being much smaller than the wavelength. In this work, a numerical and experimental study of the acoustic radiation force in acoustic wave levitators and near-field levitators was done. The simulations were performed in the finite element software COMSOL Mutiphysics. In the experimental results, an electronic scale was used to measure the acoustic radiation force and a high speed camera was applied to observe the oscillatory behavior of spherical objects inside the acoustic cavity. The study of acoustic radiation strength resulted in three main contributions. The first contribution is related to the characterization of nonlinear effects in an acoustic levitator, such as the jump phenomenon and the hysteresis phenomenon. The second contribution is related to the numerical and experimental study of the acoustic radiation force that acts on the reflector of an acoustic levitator. Finally, a study of the acoustic radiation force that acts on the reflector for the near field region was also made. In this last study, it was verified that when the transducer is small in comparison with the wavelength, an attractive force appears on the reflector. This force can be used to levitate a flat object below the transducer face, without requiring a reflector.
104

Ultrassonografia de glândulas genitais acessórias em carneiros da raça Dorper : caracterização e correlações reprodutivas /

Camela, Efigénia Singa Cassule. January 2015 (has links)
Orientador: Maria Emilia Franco Oliveira / Coorientador: Marcus Antônio Rossi Feliciano / Coorientador: Wilter Ricardo Russiano Vicente / Banca: Leandro Rodello / Banca: Lizandra Amoroso / Resumo: Objetivou-se caracterizar e descrever os parâmetros ultrassonográficos das glândulas vesiculares, prostática, bulbouretrais e os índices vasculares Doppler das artérias testicular e ilíaca interna de carneiros Dorper, correlacionando-os a avaliação testicular, seminal e níveis séricos de testosterona de acordo com a maturidade sexual dos animais. Foram avaliados 45 animais: 24 púberes (8 e 11 meses); e 21 maduros (≥ 12 meses) de idade. Os machos foram examinados por ultrassonografia antes e após colheita seminal e as glândulas foram mensuradas pela biometria. Realizou-se análise qualitativa das glândulas anexas quanto à ecotextura (homogênea e heterogênea) e ecogenicidade (hipo/hiperecoicas de alta e baixa intensidade e anecogênicos). O sêmen foi avaliado quanto a suas características morfofisiológicas. Verificou-se a glândula vesicular e bulbouretral com ecotextura heterogênea, predominando ecogenicidade hipoecogênica de baixa intensidade. A glândula prostática apresentou o parênquima com ecotextura homogênea em relação às outras glândulas e ecogenicidade hipoecogênica. Os valores para idade de 8-11 meses foram de glândula vesicular: 24,81±3,26 mm; próstata: 12,88±1,20 mm; e bulbouretral: 13,72±1,31 mm; e para os animais > 12 meses para a vesicular: 24,58±3,77; próstata: 14,22±2,67; e bulbouretral: 14,71±1,78. Houve correlações significativas (p<0,05) para as dimensões das glândulas genitais acessórias com as do testículo, com as características seminais e com a testosterona. Conclui-se que pela ultrassonografia convencional as glândulas vesicular e bulbouretral têm ecotextura heterogênea, predominando ecogenicidade hipoecogênica de baixa intensidade independentemente da idade. A glândula prostática apresenta o parênquima com ecotextura mais homogênea e a ecogenicidade mostra-se hipoecogênica de alta intensidade na parte dorsal à uretra e hipoecogênica de baixa intensidade na... / Abstract: This study aimed to characterize and describe the ultrassonographic parameters of prostate, vesicular, bulbourethral glands and Doppler vascular index of testicular arteries and internal iliac of Dorper rams, correlating them with evaluation of testicles, semen and serum testosterone levels according to the animals sexual maturity. We evaluated 45 animals: 24 pubescent (8 and 11 months) and 21 mature (≥ 12 months) of age. Males were examined by ultrasound before and after semen collection and seminal glands were biometric measured. We conducted qualitative analysis of accessory glands by the echotexture (homogenitys and heterogenety) and echogenicity (hypo/hyperechoic high and low intensity and anechogenic). Semen had it morphological and physiological characteristics evaluated. Vesicular and bulbourethral glands were found to have a heterogeneous echotexture, predominantly hypoechoic echogenicity of low intensity. The prostate gland parenchyma presented with homogeneous echo texture compared to other glands and hypoechoic echogenicity. The values for age 8-11 months were: vesicular gland (24.81±3.26 mm); Prostate (12.88±1.20 mm); and bulbourethral (13.72±1.31 mm). The values for animals> 12 months were: vesicular glands (24.58±3.77 mm); Prostate (14.22±2.67 mm); and bulbourethral (14.71±1.78 mm). There were significant correlations (p<0.05) for the dimensions of the accessory genital glands with testicles, seminal characteristics and testosterone serum levels. It is concluded that the conventional ultrasound of the vesicular and bulbourethral glands have heterogeneous echo texture, predominantly hypoechoic echogenicity of low intensity regardless of age. The prostate gland has the parenchyma with more homogeneous echo texture and echogenicity shows up high intensity hypoechoic in the dorsal part of the urethra and of low intensity hypoechoic in the ventral part to the urethra. Mature Dorper rans, showed higher dimensions ... / Mestre
105

S?ndrome de fragilidade em idosos longevos : an?lise da composi??o corporal por ultrassom

Ribeiro, Andr? 27 July 2018 (has links)
Submitted by PPG Gerontologia Biom?dica (geronbio@pucrs.br) on 2018-12-17T15:46:17Z No. of bitstreams: 1 RIBEIRO_ANDRE_TES.pdf: 4012990 bytes, checksum: 5933986cd6984b54d4f8aa39de819ad9 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2018-12-18T16:44:11Z (GMT) No. of bitstreams: 1 RIBEIRO_ANDRE_TES.pdf: 4012990 bytes, checksum: 5933986cd6984b54d4f8aa39de819ad9 (MD5) / Made available in DSpace on 2018-12-18T16:51:19Z (GMT). No. of bitstreams: 1 RIBEIRO_ANDRE_TES.pdf: 4012990 bytes, checksum: 5933986cd6984b54d4f8aa39de819ad9 (MD5) Previous issue date: 2018-07-27 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction: Fragility is a common clinical syndrome in the elderly, which causes great risks to health, disabilities, hospitalizations and consequently a high risk of mortality. The available knowledge about the multiple aspects of fragility in the elderly suggests that it is a predictor of changes in body composition, with a decline in lean mass, and in this way, a relevance in the study of the subject in long-lived patients is observed. In this aspect, the present study proposes the use of Ultrasound (US) because it is a portable method, with ease of handling and not be influenced by skinfolds, which minimizes possible inter and intra-rater variations, therefore, with greater reliability in relation to the results presented. Objectives: To identify the characteristics of the body composition through the US in the groups of non-frailty and frailty oldest-old. Methods: The greatest possible number of oldest-old were traced through the Geriatrics General Ambulatory of Hospital S?o Lucas / PUCRS. Personal and social data were collected through a questionnaire. Fragility data were obtained through five phenotypes. Body composition data were obtained through the portable US. For the analysis of the data, the sample was separated into two groups, according to the classification of fragility: frailty and non-frailty. Percentage differences between the categorical variables were calculated through the creation of cross tables between the variables. Numerical variables were presented through means, standard deviations and variances. Results: 52 elderly people with a mean age of 90.10 ? 4.49 years were evaluated. 63.5% were classified as non-frailty and 36.5% frailty. The majority of the sample is composed of women (73.1%). White race totals 86.5% and 80.5% are widowers. 31.6% of the frailty oldest-old live alone. The average amenities were higher for the frailty (3.21 ? 1.14) compared to non-frailty (2.15 ? 1.67). In the analysis of schooling, those who reported having elementary education (? 8th grade) had a higher odds ratio [RP1,22 (CI95% 1.00-1.49)] to develop fragility compared to the reference category (? high school) (p = 0.046). Through the classification of the percentage of body fat (%F) by the US, it was observed that the female longevity with scores above 33 %F, presented a higher odds ratio [RP1,81 (IC95% 1,30-2, 52)] to develop fragility compared to the category with the reference %F (<29 %F) (p <0.001). For males, those who obtained scores above 26 %F had a greater chance [RP1,81 (IC95% 1.30-2.52)] of developing fragility compared to the category with the reference %F (<23 %F) (p <0.001).Conclusion: The present study showed persuasive results between fragility syndrome and body composition. Through the analysis of body composition by Ultrasound and according to the points of cuts predicted in the literature, it was possible to identify associations between obesity and increased risk of frailty in longevity. It was concluded that, the higher the body fat levels and the lower the lean mass (sarcopenic obesity), the greater the level of fragility of the longevity above 80 years of age. / Introdu??o: Fragilidade ? uma s?ndrome cl?nica comum em idosos, que ocasiona grandes riscos para a sa?de, incapacidades, hospitaliza??es e como consequ?ncia grande risco de mortalidade. O conhecimento dispon?vel sobre os m?ltiplos aspectos da fragilidade em idosos sugerem que esta seja preditora de altera??es na composi??o corporal, com decl?nio da massa magra, e desta maneira, observa-se uma relev?ncia no estudo do tema em pacientes longevos. Neste aspecto, o presente estudo prop?e o uso do Ultrassom (US) por ser um m?todo port?til, com facilidade de manuseio e n?o ser influenci?vel pelas dobras cut?neas corporais, o que minimiza poss?veis varia??es inter e intra-avaliador, portanto, com maior confiabilidade em rela??o aos resultados apresentados. Objetivos: Identificar as caracter?sticas da composi??o corporal atrav?s do US nos grupos de longevos n?o fr?geis e com fragilidade. M?todos: Os longevos foram rastreados atrav?s do Ambulat?rio Geral de Geriatria do Hospital S?o Lucas/PUCRS. Os dados pessoais e sociais foram coletados atrav?s de um question?rio. Dados de fragilidade foram obtidos atrav?s de cinco fen?tipos. Dados de composi??o corporal foram obtidos atrav?s do US port?til. Para a an?lise dos dados, a amostra foi separada em dois grupos, de acordo com a classifica??o da fragilidade: fr?gil e n?o fr?gil. As vari?veis num?ricas foram apresentadas atrav?s das m?dias, desvio padr?es e vari?ncias. Aprovado pelo CEP-PUCRS sob n?mero CAEE 68165117.6.0000.5336. Resultados: A amostra foi composta por 52 idosos longevos com idade m?dia de 90,10?4,49 anos. 63,5% foram classificados como n?o-fr?geis e 36,5% fr?geis. A maioria s?o mulheres (73,1%). Ra?a branca soma 86,5% e 80,5% s?o vi?vos. 31,6% dos longevos fr?geis moram sozinhos. A m?dia de comorbidades foi maior para os fr?geis (3,21?1,14) comparada aos n?o-fr?geis (2,15?1,67). Na an?lise da escolaridade, longevos que relataram ter ensino fundamental (?8?s?rie), apresentaram maior raz?o de chance [RP1,22(IC95%1,00-1,49)] de desenvolver a fragilidade frente ? categoria de refer?ncia (?Ensino M?dio) (p=0,046). Atrav?s da classifica??o do percentual de gordura corporal (%G) pelo US, observou-se que os longevos do sexo feminino com escores acima de 33 %G, apresentaram maior raz?o de chance [RP1,81(IC95%1,30-2,52)] de desenvolver a fragilidade frente ? categoria com o %G de refer?ncia (<29%G) (p<0,001). Para o sexo masculino, os que obtiveram escores acima de 26 %G, apresentaram maior chance !5 [RP1,81(IC95%1,30-2,52)] de desenvolver a fragilidade frente ? categoria com o %G de refer?ncia (<23%G) (p<0,001). Conclus?o: O presente estudo mostrou resultados persuasivos entre a s?ndrome de fragilidade e a composi??o corporal. Atrav?s das an?lises de composi??o corporal por Ultrassom e conforme os pontos de cortes preditos pela literatura, foi poss?vel identificar associa??es entre obesidade e aumento do risco de fragilidade em longevos. Concluiu-se que, quanto maiores os n?veis de gordura corporal e menores os de massa magra (obesidade sarcop?nica),maior ? o n?vel de fragilidade dos longevos acima de 80 anos de idade.
106

Acesso venoso central em crian?as guiado por ultrassom

Zanolla, Gabriela Ruschel 22 August 2014 (has links)
Made available in DSpace on 2015-04-14T13:33:09Z (GMT). No. of bitstreams: 1 462339.pdf: 739502 bytes, checksum: a5c2e9c1b9d675deb38c16405678afe2 (MD5) Previous issue date: 2014-08-22 / Objective: The objective is to determine if ultrasound guidance for internal jugular vein catheterization can be safely performed, improving success rates and diminishing the procedure lenght and complication rates. Methods: Prospective randomized trial submiting 51 patients to central venous access. 1:1, on gender and age. The patients selected were between 0yrs 18yrs Tha data analysis was made utilizing the Mann-Whitney Test and Pearson s qui-squared. Results: 51 patients were submited to central venous access to internal jugular vein. 23 were US guided, and 28 procedures utilized landmark method. There was no difference betwwen groups on age and weight wise, The number of punctions to access the vein were smaller in the US group md(P25-P75) 3(2-5) X 1(1-2)p<0,001, and faster too. There was a decrease n complication rates using the US from 39% to 4,3% (p<0,009), Conclusions: The present data suggest that ultrasound guided catheterization of the internal jugular vein is more successful than the landmark method: was more rapidly done, had greater success rates and less complication rates and number of punctions. / Objetivo: Determinar se o US reduz n?mero de pun??es, tempo de procedimento e taxa de complica??es nos acessos venosos na veia jugular interna. M?todos: Estudo prospectivo, randomizado 1:1, em g?nero e idade, em pacientes de 0 a 18 anos submetidos a acesso venoso central. Para an?lise dos dados, utilizou-se o teste de Mann-Whitney e qui-quadrado de Pearson. Resultados: Foram realizados acessos em 51 pacientes, sendo 23 guiados por US. N?o houve diferen?a entre em grupos em rela??o ao peso, idade. O n?mero de pun??es necess?rias para acessar a veia foi menor com uso do US md (P25-P75) 3(2-5) X 1(1-2) p<0,001, bem como tempo de procedimento. Ocorreu uma diminui??o das complica??es com uso do ultrassom de 39% para 4,3% (p<0,009), Conclus?o: O acesso venoso na veia jugular interna guiado por ultrassom foi superior a t?cnica tradicional em termos de tempo de localiza??o da veia e de procedimento, de complica??es e de n?mero de pun??es.
107

Simulação da vascularização através da cortical óssea de mandíbulas suínas por meio da ultrassonografia modo B e Doppler / Simulation of vasularization of the cortical bone of the jaw swine by using ultrasound B mode and Doppler

Baladi, Marina Gazzano 06 July 2011 (has links)
A ultrassonografia é um método de diagnóstico que aproveita o eco produzido pelo som para ver, em tempo real, as sombras produzidas pelas estruturas e órgãos. Os aparelhos de ultrassom em geral utilizam uma frequência próxima de 1MHz. A ultrassonografia permite ainda, pelo modo Doppler, conhecer o sentido e a velocidade de fluxos sanguíneos. Por não utilizar radiação, ionizante, é um método inócuo e barato. A avaliação da circulação nos tecidos corpóreos pode indicar o tipo de lesão ou, nos casos de cirurgia, mostrar a posição de artérias presentes na região. Neste trabalho foi de finalidade apresentar a espessura óssea ideal para a captação do sinal Doppler, utilizando uma amostra de 10 mandíbulas suínas maceradas, avaliando-se a região dos terceiros molares (de ambos os lados, direito e esquerdo, totalizando 20 hemimandíbulas). As mandíbulas suínas foram preparadas para receber e adaptar tubos de CFlex conectados a um capilar de vidro e a uma bomba propulsora, por onde passava o líquido, simulando a vascularização sanguínea. Foram tomadas diferentes medidas de espessura óssea, sendo possível, em algumas hemimandíbulas, captarmos sinais. Na dependência da espessura da cortical óssea, que em nosso trabalho estudamos no intervalo de 0,2 a 1,0mm, possibilitou-se a captação de sinais, no modo B e Doppler, referentes ao simulador da vascularização. A ultrassonografia é um recurso imaginológico com aplicabilidade cada vez maior na área da Saúde, em particular no estudo da vascularização intraóssea. / Ultrasound is an image diagnostic method that takes advantage of the echo produced by sound to see in real time, the shadows produced by the structures and organs. Ultrasound machines typically use a frequency of about 1MHz. The ultrasound also enables, by the Doppler mode, to read the direction and velocity of blood flow. As we do not use radiation, ionizing radiation, it is a harmless and inexpensive method. The evaluation of the circulation in body tissues may indicate the type of injury, or in cases of surgery, it shows the position of the arteries in the region. This study aimed to present the ideal bone thickness to capture the Doppler signal using a sample of 10 macerated pig jaws, assessing the region of the third molars (on both sides, right and left, totaling 20 hemijwas). The pig jaws were prepared to accept and adapt CFlex tubes connected to a glass capillary and a pump, through which liquid flowed, simulating the blood vasculature. Different measures of bone thickness, were taken and in some hemijaws signals were possible to be taken. Depending on the thickness of cortical bone, which in our work we have studied in the range 0,2 to 1,0 mm, made it possible to capture signals in B mode and Doppler simulator for the vasculature. Ultrasound is a resource imaginologic increasing applicability in healthcare, particularly in the study of intraosseous vascularity.
108

Avaliação dos parâmetros de imagens de massas anexiais pélvicas em tele-ecografia.

Gonçalves, Fausto da Silva 14 March 2013 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2017-05-26T12:24:58Z No. of bitstreams: 1 faustodasilvagonçalves_dissert.pdf: 1310792 bytes, checksum: 52a5579dab6c9a6b5bf94f7d828a2eef (MD5) / Made available in DSpace on 2017-05-26T12:24:58Z (GMT). No. of bitstreams: 1 faustodasilvagonçalves_dissert.pdf: 1310792 bytes, checksum: 52a5579dab6c9a6b5bf94f7d828a2eef (MD5) Previous issue date: 2013-03-14 / Introduction: According to the World Health Organization, is a diagnostic imaging procedure necessary for the accurate treatment of at least 25% of patients worldwide. While the imaging technology has evolved so dizzying, over 90% of all images required can be performed with simple machines to ultrasound and X- rays. There are data indicating Transvaginal Ultrasonography as one of the most effective methods for detecting ovarian tumors, to be safe, fast, easy to perform and well accepted by patients. It is the most frequently used test for this purpose due to its excellent cost / benefit ratio, being an innocuous and widely used method in the diagnosis of adnexal masses. Numerous studies have been conducted to differentiate adnexal masses and thereby reduce the number of patients subjected to inappropriate treatment. Objectives: Evaluation of sonographic parameters related with the morphological characteristics of pelvic adnexal masses by obtaining two-dimensional images taken by observer presence and sent electronically (via Tele-Ultrasound) in static mode and dynamic observers do not face (distance) for comparative analyzes inter-and intra-observer and validation of a second opinion. Methods: From March to August 2010 50 patients were selected for presenting viewing adnexal mass on ultrasound. The pelvic sonographic examinations were performed by cesarean section and by vaginal Imaging Unit in the Department of Obstetrics and Gynecology, Hospital de Base in São José do Rio Preto. The adnexal masses were evaluated according to their morphological characteristics. Results: There was good inter-rater agreement independent of the modality (dynamic and static) used. Conclusions: The sonographic parameters of the morphological characteristics of pelvic adnexal masses directed by Tele-Ultrasound is capable of being validated for issuing a second opinion. There were no significant differences in the methodology employed in the issue of tele-ultrasound images (static or dynamic) to characterize the composition of pelvic adnexal masses. / Introdução: De acordo com a Organização Mundial de Saúde, o diagnóstico por imagem é um procedimento necessário para o tratamento acurado de pelo menos 25% dos pacientes em todo o mundo. Embora a tecnologia de imagem tenha evoluído de forma vertiginosa, mais de 90% de todas as imagens necessárias podem ser realizadas com máquinas simples de Ultrassonografia e Raios-X. Há dados indicando a Ultrassonografia Transvaginal como um dos métodos mais efetivos para detecção de tumores ovarianos, por ser seguro, rápido, fácil de realizar e bem aceito pelas pacientes. É o exame mais utilizado para esse propósito devido a sua excelente relação custo/benefício, ser um método inócuo e amplamente utilizado no diagnóstico de massas anexiais. Inúmeros estudos têm sido realizados para diferenciar as massas anexiais e assim reduzir o número de pacientes submetidas a tratamentos inadequados. Objetivos: Avaliação dos parâmetros ultrassonográficos relacionados com as características morfológicas de massas anexiais pélvicas através da obtenção de imagens bidimensionais realizadas por observador presencial e encaminhadas eletronicamente (via Tele-Ecografia) no modo estático e dinâmico a observadores não presenciais (à distância) para análises comparativas inter e intra- observadores e validação de uma segunda opinião. Casuística e métodos: No período de março a agosto de 2010 foram selecionadas 50 pacientes por apresentarem visualização de massa anexial ao exame ecográfico. Os exames ultrassonográficos pélvicos foram realizados por via abdominal e por via endovaginal na Unidade de Imagenologia do Departamento de Ginecologia e Obstetrícia do Hospital de Base de São José do Rio Preto. As massas anexiais foram avaliadas de acordo com suas características morfológicas. Resultados: Houve uma boa concordância inter-examinadores independente da modalidade (dinâmica e estática) utilizada. Conclusões: Os parâmetros ultrassonográficos das características morfológicas de massas anexiais pélvicas encaminhadas por Tele-Ecografia são passíveis de serem validadas para a emissão de uma segunda opinião. Não houve diferenças significativas quanto à metodologia empregada na emissão das imagens tele-ecograficas (estática ou dinâmica) na caracterização da composição das massas anexiais pélvicas.
109

Sintese mediada por ultrassom de potenciais antibióticos e antitumorais derivados de glicopiranosil 1,2,3-triazóis

SILVA, Gilson Bezerra da 31 March 2011 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2017-02-16T12:52:21Z No. of bitstreams: 1 Gilson Bezerra da Silva.pdf: 6058425 bytes, checksum: b0b0770ddfb3e8e122bab73651c925a3 (MD5) / Made available in DSpace on 2017-02-16T12:52:21Z (GMT). No. of bitstreams: 1 Gilson Bezerra da Silva.pdf: 6058425 bytes, checksum: b0b0770ddfb3e8e122bab73651c925a3 (MD5) Previous issue date: 2011-03-31 / The purpose of this work is to synthesize a novel B glycosilpyranose linked to heterocyclic 1,2,3-triazole at N-1 under ultrasound irradiation. We have been engaged in the preparation of various glycosyl triazoles from the reaction between glycosyl azide and terminal alkynes. The glycosyl triazoles have been obtained in moderate to excellent yields (63-99%) through the copper (I)- catalyst 1,3-dipolar cycloaddition reaction at room temperature using ultrasound irradiation. We have also applied the ultrasound energy to increase the chemical reactivity in all reaction steps, which consequently enhanced notabily the reaction rates as well as the yields. Carrageenan-induced paw edema model was used to assess the anti-inflammatory effect. Preliminary antiinflammatory activity tests have been performed with substituted 1,2,3-triazole contaning glycoconjugates and the results demonstrate that these compounds are able to reduce the carrageenan-induced paw swelling by 49.2-64.7%, and represent a promising starting point for further modification of drug candidates which should be useful treating inflammation. / O propósito deste trabalho foi sintetizar uma nova série de B glicosilpiranose ligada ao heterociclo 1,2,3-triazólico, pelo nitrogênio N-1, sob irradiação de ultrassom. Estamos empenhados na preparação de vários triazóis ligados a glicopiranose a partir da reação entre -glicopiranosil azida e vários alcinos terminais. Os glicopiranosil-triazóis foram obtidos em moderados a excelentes rendimentos (63-99%) pela reação de cicloadição 1,3-dipolar catalisada por cobre (I) à temperatura ambiente empregando a irradiação de ultrassom. Também aplicamos a energia de ultrassom para aumentar a reatividade química em todas as etapas de reação, aumentando notavelmente tanto a velocidade da reação quanto os rendimentos dos produtos desejados. O estudo do efeito da atividade anti-inflamatória foi avaliado através da indução da inflamação pela carragenina. Testes preliminares da atividade antiinflamatória foram realizados para os glicoconjugados de benzoeterociclos-1,2,3-triazólicos e os resultados demonstraram que estes compostos reduziram o edema da pata induzido pela carragenina em 49,2-64,7%, e representa promissor ponto de partida no desenvolvimento de candidatos a fármacos para uso em terapias anti-inflamatórias.
110

Influência da ativação ultrassônica do gel de hipoclorito de sódio 3 por cento, e da medicação intracanal com hidróxido de cálcio sobre micro-organismos e ácido lipoteicóico /

Pelegrini, Fernanda Carvalho. January 2017 (has links)
Orientador: Claudio Antônio Talge Carvalho / Banca: Márcia Carneiro Valera Garakis / Banca: Renato Miotto Palo / Resumo: O objetivo deste estudo foi avaliar in vitro a ação do gel de hipoclorito de sódio (NaOCl) 3 % e da medicação intracanal (MIC) de hidróxido de cálcio (CaOH2), agitados ou não por ultrassom sobre Enterococcus faecalis, Escherichia coli e ácido lipoteicóico (LTA). Para isso 80 dentes humanos unirradiculares tiveram suas coroas removidas padronizando seu comprimento em 16 mm +- 0,5 mm, sendo seus canais instrumentados inicialmente até instrumento R25 (Reciproc). Os canais foram contaminados com suspensões de E. faecalis e E. coli. Os canais foram instrumentados utilizando-se instrumento R40, sob irrigação com 2 ml de NaOCl 3% gel seguida de irrigação com 10 ml de solução salina estéril e apirogênica. Após os canais foram irrigados com EDTA 17%, seguido de irrigação com 5 ml de solução salina estéril e apirogênica, sendo por último preenchidos com medicação intracanal de hidróxido de cálcio mantida durante 7 ou 14 dias. Os espécimes foram divididos inicialmente em 2 grupos (n=40) de acordo com a agitação ultrassônica (US) ou não da substância química auxiliar. Sendo novamente divididos de acordo com a agitação ultrassônica ou não da medicação intracanal (MIC) e o tempo de ação desta (n=10): 1) NaOCl + Ca(OH)2 (7 dias). 2) NaOCl + Ca(OH)2 (14 dias). 3) NaOCl + Ca(OH)2 com US (7 dias) 4) NaOCl + Ca(OH)2 com US (14 dias). 5) NaOCl com US + Ca(OH)2 (7 dias). 6) NaOCl com US + Ca(OH)2 (14dias) 7) NaOCl com US + Ca(OH)2 com US (7dias). 8) NaOCl com US + Ca(OH)2 com US (14 dias). For... (Resumo completo, clicar acesso eletrônico abaixo) / The aim of this study was to evaluate in vitro the action of sodium hypochlorite (NaOCl) 3% gel and calcium hydroxide as an intracanal medication, both activated by ultrasound on the reduction of E. faecalis e E. coli and lipotheicoic acid (LTA). Eight human single-rooted teeth with standardized size of 16 mm were prepared initially to R25 instrument (Reciproc) and distributed in microplate (n = 10). After sterilization (Co60 gamma radiation), the infection was carried out 8 microlitres of E. coli suspension, and after 7 days 8 microlitres of E. faecalis suspension, maintained for 21 days. Following the collection confirmation was performed (1st collection), then the root were instrumented using R40 instrument, irrigation with 2 ml of NaOCl 3% gel followed by washing with 10 ml of saline. The specimens were divided into 8 groups (n = 10) according to different ultrasonic irrigation protocols and different periods exposed to intracanal medication: 1) NaOCl + Ca(OH)2(7 days). 2) NaOCl + Ca(OH)2 (14 days). 3) NaOCl + Ca(OH)2 with PUI (7 dias) 4) NaOCl + Ca(OH)2 with PUI (14 days). 5) NaOCl with PUI + Ca(OH)2 (7 days). 6) NaOCl with PUI + Ca(OH)2 (14 days) 7) NaOCl with PUI + Ca(OH)2 (7 days). 8) NaOCl with PUI + Ca(OH)2 with PUI (14 days). Were made to sample colections of content of root canals, after instrumentation (2nd sample), after the use of EDTA (3rd sample) and after the Ca(OH)2 (4th Collection) . Microbiological culture and LTA quantification revealed that 3 % NaOCl gel was capable to eliminate E. faecalis and E. coli almost completely from root canals, but not lipotheicoic acid, regardless the use of ultrasonic activation. The ultrasonic activation of intracanal medication (Ca(OH)2) was not effective in removing neither microorganisms nor LTA. In addition, the groups with greatest reduction were the ones with no ultrasonic activation either of intracanal.... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre

Page generated in 0.0539 seconds