• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 11
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 54
  • 54
  • 35
  • 21
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Fonte ininterrupta de energia trifásica de alto desempenho sem transformador com dupla funcionalidade do estágio de entrada e sistema de controle digital / High performance three-phase transformerless uninterruptible power supply with double functionality of the input stage and digital control system

Venturini, William Alegranci 21 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This master s thesis proposes a three-phase transformerless double-conversion UPS with digital control system and reduced overall cost. The topology is composed of an input stage, a battery bank, an inverter, an auxiliary circuit and transfer switches. The input stage assumes the three-phase rectifier function with LCL filter in normal operation mode and is responsible for discharge the battery bank in backup mode. This configuration reduces the system cost since an available circuit is used to discharge the battery bank. In conventional double-conversion UPS topologies the input stage remains inactive during the backup mode and an additional circuit is employed for this purpose. The auxiliary circuit is formed by an inductor and a switching leg and is used as a battery charger during normal operation mode and is additionally used to balance the bus capacitors voltages in backup mode. In this configuration, the auxiliary circuit can be designed for only a fraction of the UPS rated power, also providing lower total system cost. Transfer switches change the configuration of the input stage and the auxiliary circuit according to the UPS operating mode. The detailed operation of the topology, modelling, digital control structure, and the results obtained by simulation are showed. Finally a 20 kVA prototype is implemented and experimental results are acquired for the validation of the employed design methodology as well as the proposed circuit functionality. / Esta dissertação de mestrado propõem uma topologia de fonte ininterrupta de energia (UPS - Uninterruptible Power Supplies) trifásica de dupla conversão sem transformador com custo reduzido e sistema de controle digital. A UPS proposta é composta por um estágio de entrada, um banco de baterias, um inversor, um circuito auxiliar e chaves de transferência. O estágio de entrada assume a função de retificador trifásico com filtro LCL em modo normal de operação da UPS e é responsável pela descarga do banco de baterias em modo bateria de operação. Esta configuração reduz o custo do sistema, pois permite que seja aproveitado um circuito disponível e dimensionado para a potência nominal da UPS para a descarga do banco de baterias. Em topologias convencionais de UPSs de dupla conversão o estágio de entrada permanece ocioso durante este modo de operação e um circuito adicional é empregado para este fim. O circuito auxiliar é formado por um indutor e um braço de interruptores e é utilizado como carregador de baterias em modo normal de operação e adicionalmente é utilizado para realizar o equilíbrio das tensões dos capacitores de barramento em modo bateria. Com esta configuração, o circuito auxiliar pode ser dimensionado para apenas uma fração da potência nominal da UPS, propiciando também a redução do custo total do sistema. As chaves de transferência alteram as configurações do estágio de entrada e do circuito auxiliar de acordo com o modo de operação da UPS. É apresentada a operação detalhada da topologia, a modelagem, a estrutura de controle digital utilizada e os resultados obtidos via simulação. Por fim, um protótipo de 20 kVA é implementado e resultados experimentais são adquiridos para a validação da metodologia de projeto empregada bem como da funcionalidade do circuito proposto.
42

Projeto em tempo discreto de controladores ressonantes aplicados a fontes ininterruptas de energia

Keiel, Guilherme January 2017 (has links)
Este trabalho apresenta um estudo da discretização de controladores ressonantes aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Suppllies). Primeiramente, diferentes métodos de discretização serão considerados na obtenção de um modelo em tempo discreto da UPS. Além disso, estes métodos serão comparados do ponto de vista frequencial para a definição da formulação do controlador ressonante a ser utilizado. Então, uma metodologia de projeto robusto do controlador ressonante em tempo discreto é proposta a partir de uma representação em espaço de estados do sistema em malha fechada e os parâmetros do controlador são obtidos através da solução de um problema de otimização convexa sujeito a restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). A estratégia proposta foi validada por meio de resultados de simulação e experimentais obtidos com um inversor comercial de 3,5 kVA considerando os critérios estabelecidos na norma IEC 62040-3. Nestas condições, demonstrara-se um desempenho melhor do que os obtidos com a discretização do controlador projetado em tempo contínuo, sobretudo quando consideradas frequências de amostragem menores. / This work presents a study about discrete-time resonant controllers applied to uninterruptible power supplies (UPSs). First, different discretization methods are considered to obtain an equivalent UPS discrete-time model. Moreover, these methods are compared in the frequency domain in order to define the resonant controller structure to be employed. Then, a robust design methodology to the discrete-time resonant controller is proposed using a state-space representation of the closed-loop system and the controller parameters are obtained by solving a convex optimization problem subject to constraints in the form of Linear Matrix Inequalities (LMIs). The proposed strategy was validated by means of simulation and experimental results obtained with a 3.5 kVA commercial inverter taking into account the IEC 62040-3 norm requirements. In this conditions, a better performance was achieved than those obtained through discretization of a continuous-time controller, especially when considering smaller sampling frequencies.
43

Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)

Barden, Alisson Thomas January 2016 (has links)
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensão de saída devido às correntes com elevado conteúdo harmônico drenadas pelas cargas. Além disso, o controle é formulado em referencial síncrono (dq0) utilizando controladores Proporcional-Integral (PI) convencionais muito difundidos na maioria das aplicações comerciais de UPS. O projeto de ambos controladores é realizado utilizando uma metodologia de controle robusto com realimentação de estados, onde os parâmetros dos controladores são determinados através da resolução de um problema de otimização convexa sujeito a um conjunto de restrições na forma de desigualdades matriciais lineares (LMI). Uma análise comparativa de desempenho é realizada entre controladores com um modo ressonante (sintonizado na fundamental) e o PI em dq0, pois apresentam estruturas funcionalmente equivalentes sob a ótica do princípio do modelo interno aplicada a seus respectivos referenciais. Além do mais, demonstra-se a melhoria no desempenho com o uso dos controladores múltiplo ressonantes em referencial estacionário onde escolhe-se as frequências de ressonância de cada modo de maneira a suprimir os efeitos de harmônicas específicas na tensão de saída da UPS. A análise comparativa entre os controladores propostos é realizada através de simulações numéricas, utilizando os procedimentos de ensaio dinâmico e estático e as exigências estabelecidas pela norma internacional IEC 62040-3. / The main objective of this work is the development of robust controllers based on the internalmodel principle, in synchronous and stationary frames, applied to the output stage of an uninterruptible power supply (UPS), in order to minimize the output voltage distortion caused by the connection of balanced and unbalanced nonlinear loads. The formulation in stationary abc-frame is accomplished through the aplication of a multiple resonant controller, so that, it is possible to achieve zero-error tracking of the sinusoidal reference and disturbances rejection on the output voltage due to the high amount of harmonic currents drained by the loads. Moreover, a controller in synchronous reference frame (dq0 axis) is formulated through the application of conventional Proportional-Integral (PI) controllers which are widely used in comercial UPS applications. The design of both controllers is formulated using a state-feedback robust controlmethod, in which the controller parameters are determined by solving a convex optimization problem subject to a set of LMI constraints. A comparative analysis on the performance of the single-mode resonant controller (tuned at the fundamental frequency) and the PI controller is performed, because these controllers are functionally equivalent in the sense of the internal model principle applied to their respective frames. Furthermore, the improvement in performance is demostrated with the use of multiple resonant controllers in stationary abc-frame where the resonance frequencies are chosen to suppress the effects of a specific harmonic in the UPS output voltage. The comparative analysis of the proposed controllers is performed through numerical simulations, making use of the dynamical and steady-state test methods and performance requirements defined by the IEC 62040-3 international stardard.
44

Análise de variações topológicas aplicadas a uma UPS tipo delta monofásica

Ghetti, Frederico Toledo 26 May 2009 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-03-02T11:39:15Z No. of bitstreams: 1 fredericotoledoghetti.pdf: 2816885 bytes, checksum: 98c4c49d919a94d51a94ff86a91c33a1 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-06T19:32:09Z (GMT) No. of bitstreams: 1 fredericotoledoghetti.pdf: 2816885 bytes, checksum: 98c4c49d919a94d51a94ff86a91c33a1 (MD5) / Made available in DSpace on 2017-03-06T19:32:09Z (GMT). No. of bitstreams: 1 fredericotoledoghetti.pdf: 2816885 bytes, checksum: 98c4c49d919a94d51a94ff86a91c33a1 (MD5) Previous issue date: 2009-05-26 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / É apresentado, neste trabalho, um estudo sobre topologias alternativas de fontes ininterruptas de energia do tipo Delta, para o emprego em cargas monofásicas de até 1kVA. O estudo prevê a inserção de um conversor CC-CC entre o conversor shunt e o banco de baterias. Tal modificação em relação à UPS do tipo Delta convencional otimiza o projeto do banco de baterias e requisita um menor número de células em série para sua confecção. Além disso, a proposta elimina o uso de transformadores de baixa freqüência, considerados em alguns trabalhos anteriores, o que também contribui para a redução do peso e volume do sistema. Duas diferentes topologias para o conversor CC-CC foram investigadas e comparações de desempenho e viabilidade foram realizadas. A topologia que apresentou melhor desempenho nos quesitos custo, volume e peso, foi selecionada para testes em bancada. Ao final, resultados simulados e práticos são apresentados para validação do modelo. / This dissertation presents a study on single-phase Delta-UPS topological alternatives for low power and low cost applications. The proposed topology has a DC-DC converter connected between the shunt inverter and the battery bank/series converter DC terminals, respectively. This modification will allow the downsizing of the DC battery bank as well as the removing of the series converter transformer. Two different topologies of the DC DC converter were investigated and a comparative study among them will be accomplished. Simulation results are presented and experimental results will be included to validate the proposed study.
45

Sledování vlivu teploty na vlastnosti olověných akumulátorů / Monitoring of temperature influence on properties of lead-acid accumulators

Musil, Petr January 2019 (has links)
This thesis deals with lead-acid battery, its parameters and temperature behaviour of this electro-chemical source of power. In the theory section, types of batteries are presented, followed by their primary parameters and electro-chemical reactions, which take part in battery cells. This section also contains information about charging stages, detailed description of each battery part, used materials, construction of the battery and degradation processes caused by battery operation. The practictal section of this thesis offers a measurement scheme for automated measuring workstation. Furthermore, the practical section presents results of measurements on parameters of chosen lead-acid battery types, it also contains long-term deep battery cycling and measurements under elevated temperatures. Detailed comparison of measurements results and datasheet values is included. Conclusion sums up parameters of chosen lead-acid battery types and their feasibility for further usage in power backuping.
46

Návrh zajištění bezpečnosti DC v silové infrastruktuře a jeho dopad na ekonomiku podniku / A Suggestion to Ensure Safety of DC in Power Infrastructure and its Impact on Economics of an Enterprise

Trůčka, Martin January 2010 (has links)
The aim of this thesis is a description of a proposal to ensure safety of DC in power infrastructure and its impact on economics of an enterprise. The first part is focused on the analysis of the whole situation. The work also contains other possibilities of solution with respect to theoretical resources. The attention is also drawn to a particular procedure to minimize the financial loss of the company caused by a power failure and to a plan for providing maximum protection against this power failure.
47

Inversores fotovoltaicos conectados à rede com armazenamento de energia – classificação, recomendações técnicas e gerenciamento / Grid-connected photovoltaic energy storage systems – classification, technical recommendations and management

Bellinaso, Lucas Vizzotto 08 March 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Grid-connected photovoltaic systems with energy storage have features of conventional gridconnected inverters and uninterruptible power supplies. In these systems, all elements, which include photovoltaic generator, batteries, loads and electric grid, are connected to the same equipment named multifunctional photovoltaic converter. As it is a recent technology, there are many research opportunities in this theme, from classifications and standards to specific problems. This study investigates this field in a comprehensive manner, proposing classifications, technical recommendations and a power management strategy. Initially, classifications are proposed considering system configuration and continuity of supply to the loads. In the following, technical recommendations related to grid and load compatibility, as well as safety technical recommendations, are proposed. The last proposal consists on a power management strategy which defines the operation mode of the static converters and system elements as a function of the energy scarcity. Experimental results of the power management are presented in order to validate the proposals. In this way, this thesis contributes to the development of multifunctional photovoltaic converters technology so that the distributed generation becomes more independent of solar availability and can better collaborate with the electric system. / Sistemas fotovoltaicos conectados à rede com armazenamento de energia são aqueles que conjugam características dos inversores conectados à rede convencionais e de fontes ininterruptas de energia. Nesses sistemas, todos os seus elementos, que incluem o gerador fotovoltaico, as baterias, as cargas e a rede elétrica, são conectados a um mesmo equipamento chamado de conversor fotovoltaico multifuncional. Por se tratar de uma tecnologia recente, existem muitas oportunidades de pesquisa inédita no tema, desde premissas e classificações básicas até a solução de problemas mais específicos. Este trabalho investiga o tema de maneira abrangente, propondo classificações, recomendações técnicas e uma estratégia para gerenciamento interno de potência dos conversores fotovoltaicos multifuncionais. Inicialmente, classificações são propostas considerando a configuração do sistema e a continuidade de fornecimento de energia às cargas. A seguir, são propostas recomendações técnicas relacionadas à compatibilidade com a rede e com as cargas, além de recomendações técnicas de segurança, baseando-se em normas existentes. A última proposta consiste em uma estratégia de gerenciamento interno de potência que define os modos de operação dos conversores estáticos e dos elementos do sistema em função da escassez de energia. Resultados experimentais do método proposto para o gerenciamento interno de potências são apresentados com o objetivo de validar as propostas desenvolvidas. Dessa forma, o presente trabalho contribui com o desenvolvimento da tecnologia de conversores fotovoltaicos multifuncionais, para que a geração distribuída de energia elétrica se torne mais independente da disponibilidade solar e possa melhor colaborar com o sistema elétrico.
48

Análise e implementação de um circuito de auxílio à comutação integrado aplicado a uma fonte ininterrupta de energia / Analysis and implementation of an integrated auxiliary commutation circuit applied to an uninterruptible power supply

Oliveira, Adriano Toniolo de 14 April 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study proposes an auxiliary commutation circuit, applied to a double-conversion uninterruptible power supply, operating with a three-level PWM full-bridge inverter. In order to construct this circuit, we use the concept of integration of auxiliary commutation circuit: the case study of ZVT. The concept of iCAC is not directly applied to three-level PWM inverters. Then, it is necessary the use of classic auxiliary commutation techniques combined with the concept of integration. In this study, it is presented a hybrid auxiliary commutation circuit. Due to the restrictions imposed by the iCAC, just one of the inverter legs can be integrated. To the other inverter leg it is used a conventional auxiliary commutation circuit. The proposed system aims at achieving a better performance if compared to the same uninterruptible power supply operating with a classic ZVT auxiliary commutation circuit. There is also the advantage that all the auxiliary switches operate with ZVS and/or ZCZ soft switching. Through the use of iCAC it is obtained a minimization of circulating reactive energy in the auxiliary commutation circuits and it contributes to increase the global performance of the uninterruptible power supply. The number of additional components is reduced in relation to the classic CAC and, consequently, the system becomes more attractive to the industry. During this study, the analysis of the system and the simulation results are presented. Finally, experimental results are presented, comparing the efficiency of the CAC iZVT proposed system versus the classic CAC ZVT, in order to validate the proposed system. / Este trabalho propõe um circuito de auxílio à comutação, aplicado a uma fonte ininterrupta de energia de dupla conversão, operando com inversor PWM ponte completa modulado em três níveis de tensão. Para obtenção desse circuito, este trabalho utiliza o conceito de integração de circuitos de auxílio à comutação: O estudo do caso ZVT. O conceito de iCAC não é aplicável diretamente a inversores PWM modulados em três níveis de tensão. Dessa forma faz-se necessário a utilização de técnicas clássicas de auxílio à comutação em conjunto com o conceito de integração. A partir deste estudo é proposto um circuito de auxílio à comutação híbrido. Devido às restrições impostas pelo iCAC apenas uma das pernas do inversor pode ser integrada. Para a outra perna do inversor é então utilizado um circuito de auxílio à comutação convencional. O sistema proposto visa obter melhor rendimento em relação à mesma fonte ininterrupta de energia operando com circuito de auxílio à comutação clássicos do tipo ZVT. Há também a vantagem de que todas as chaves auxiliares operam com comutação suave ZVS e/ou ZCS. Com uso do conceito de iCAC é obtida a minimização da energia reativa circulante nos circuitos de auxílio à comutação, o que contribui para elevar o rendimento global da fonte ininterrupta de energia. O número de componentes adicionais é reduzido em relação ao CAC clássico, tornando assim o sistema atrativo à indústria. Ao longo desse estudo, são apresentadas as análises do funcionamento do sistema e resultados de simulação são apresentados. Por fim, resultados experimentais são apresentados, comparando a eficiência do sistema proposto CAC iZVT versus CAC ZVT clássico, para dessa forma validar o sistema proposto.
49

Projeto e implementação de método para conexão paralela de UPSs com compartilhamento de potência

Annunziato, Rafael Christiano 31 August 2012 (has links)
Este trabalho apresenta o projeto e a implementação prática de um método completo para ser utilizado na conexão de UPSs monofásicos em paralelo. Existe um algoritmo que executa o droop de fase/frequência, e um novo método que trabalha com e sem comunicação de dados entre os inversores. Quando a comunicação está ativa, um novo algoritmo é utilizado, inserindo um resistência virtual variável, junto com o compartilhamento de potência ativa, obtendo um baixo valor de THD (Total Harmonic Distortion) na tensão de saída e bom compartilhamento de potência. Quando a comunicação de dados não funciona, uma resistência virtual constante é inserida, aumentando a THD de saída com carga não-linear, mas ainda proporcionando um bom compartilhamento de potência ativa. A vantagem é poder obter um bom desempenho quando a comunicação de dados está operando, mas, no caso de sua falha, o sistema ainda funciona, proporcionando maior confiabilidade. A implementação possui um algoritmo de emulação de carga eletrônica, com o propósito de executar testes de produção, baseado no mesmo algoritmo de paralelismo, apenas mudando algumas variáveis. / This work presents the design and experimental implementation of a complete paralleling method to be used for parallel single-phase UPSs connection. There is a algorithm that performs a phase/frequency droop, and a new method to work with or without data communication among the inverters. When communication is working, a new algorithm is used, inserting a variable virtual resistance in the output, along with active power sharing, obtaining a low output voltage THD (Total Harmonic Distortion) value and good power sharing. Without communication a constant virtual resistance is inserted, increasing the output THD with non-linear load, but still allowing a good active power sharing. The advantage is to obtain a good performance operation with communication, but, in case of communication failure, the system still works providing more reliability. The implementation have a electronic load emulation algorithm, with purpose to execute factory tests, based in the same parallelism algorithm, just changing some variables.
50

Projeto e implementação de método para conexão paralela de UPSs com compartilhamento de potência

Annunziato, Rafael Christiano 31 August 2012 (has links)
Este trabalho apresenta o projeto e a implementação prática de um método completo para ser utilizado na conexão de UPSs monofásicos em paralelo. Existe um algoritmo que executa o droop de fase/frequência, e um novo método que trabalha com e sem comunicação de dados entre os inversores. Quando a comunicação está ativa, um novo algoritmo é utilizado, inserindo um resistência virtual variável, junto com o compartilhamento de potência ativa, obtendo um baixo valor de THD (Total Harmonic Distortion) na tensão de saída e bom compartilhamento de potência. Quando a comunicação de dados não funciona, uma resistência virtual constante é inserida, aumentando a THD de saída com carga não-linear, mas ainda proporcionando um bom compartilhamento de potência ativa. A vantagem é poder obter um bom desempenho quando a comunicação de dados está operando, mas, no caso de sua falha, o sistema ainda funciona, proporcionando maior confiabilidade. A implementação possui um algoritmo de emulação de carga eletrônica, com o propósito de executar testes de produção, baseado no mesmo algoritmo de paralelismo, apenas mudando algumas variáveis. / This work presents the design and experimental implementation of a complete paralleling method to be used for parallel single-phase UPSs connection. There is a algorithm that performs a phase/frequency droop, and a new method to work with or without data communication among the inverters. When communication is working, a new algorithm is used, inserting a variable virtual resistance in the output, along with active power sharing, obtaining a low output voltage THD (Total Harmonic Distortion) value and good power sharing. Without communication a constant virtual resistance is inserted, increasing the output THD with non-linear load, but still allowing a good active power sharing. The advantage is to obtain a good performance operation with communication, but, in case of communication failure, the system still works providing more reliability. The implementation have a electronic load emulation algorithm, with purpose to execute factory tests, based in the same parallelism algorithm, just changing some variables.

Page generated in 0.0667 seconds