• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 280
  • 42
  • 31
  • 12
  • 12
  • 12
  • 12
  • 10
  • 10
  • 10
  • 10
  • 8
  • 7
  • 2
  • 2
  • Tagged with
  • 390
  • 249
  • 107
  • 59
  • 52
  • 51
  • 34
  • 34
  • 32
  • 31
  • 30
  • 28
  • 27
  • 26
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

COMBINED POSTERIOR-ANTERIOR SURGERY FOR OSTEOPOROTIC DELAYED VERTEBRAL FRACTURE WITH NEUROLOGIC DEFICIT

KATO, FUMIHIKO, ISHIGURO, NAOKI, MACHINO, MASAAKI, ITO, KEIGO, YUKAWA, YASUTSUGU, NAKASHIMA, HIROAKI 08 1900 (has links)
No description available.
212

Prevalencia de osteoporose, fraturas vertebrais, ingestao de calcio e deficiencia de vitamina D em mulheres pos-menopausa

Farias, Francisco Alfredo Bandeira e. January 2003 (has links) (PDF)
Doutor -- Escola Nacional de Saude Publica, Rio de Janeiro, 2003.
213

Perturbações músculo-esqueléticas na região lombar da coluna-estudo comparativo entre nadadores de lazer e nadadores de competição

Fernandes, Rui Manuel Pinhão January 1999 (has links)
No description available.
214

Estudo da aplicação de força durante a técnica de mobilização póstero anterior central na coluna lombar

Muta, Henrique Shimanuki [UNESP] 01 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-01Bitstream added on 2014-06-13T18:57:57Z : No. of bitstreams: 1 muta_hs_me_guara.pdf: 492160 bytes, checksum: c31427e991b74ee256fe65b5d34cc2ce (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Na fisioterapia existem procedimentos que dependem da percepção manual do fisioterapeuta por estarem relacionados à aplicação de forças graduadas. Alguns estudos demonstraram que há uma grande dificuldade na percepção da força, ocorrendo grande variabilidade em sua aplicação. O objetivo deste estudo foi desenvolver um equipamento portátil para a medida de forças aplicadas por fisioterapeutas durante a realização da técnica de pressão póstero anterior central na coluna lombar e analisar alguns parâmetros envolvidos no método de mobilização articular. Houve variabilidade na forma de aplicação das cargas em diferentes aspectos. Dessa forma, podemos demonstrar com esses resultados, que a percepção manual do fisioterapeuta durante a realização da técnica de pressão póstero anterior central não foi tão precisa comparando os valores estimados com os valores das cargas aplicadas durante o intervalo de coleta. / In Physical Therapy there are some procedures that depend on manual sensibility of physical therapist because that involves graded forces. Some studies have shown that there is a great difficulty in the perception of the force, occuring great variability on the application. The purpose of this study is to develop a portable device to measure the forces applied by physical therapists during the procedure of posteroanterior central pressure in the lumbar spine and to analyze some parameter involved in the method of articular mobilization. There was variability in application of the technique in many ways. Therefore, we can show with these results that the manual sensibility of the physical therapists during the application of the posteroanterior central pressure technique wasnþt accurate comparing the estimated values to the actual results obtained during the experiment interval of time.
215

Desenvolvimento de dispositivos para realização de testes in vitro em coluna vertebral

Lemos, Felipe Fernandes [UNESP] 13 January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-01-13Bitstream added on 2014-06-13T19:37:19Z : No. of bitstreams: 1 lemos_ff_me_guara.pdf: 3167749 bytes, checksum: 900a2570260a39cccd178d8a2ecb5b4a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Para melhor entender os mecanismos degenerativos da coluna vertebral e avaliar o melhor método para seu tratamento é necessário que se conheça o comportamento dos diversos componentes das articulações intervertebrais. Com isso, torna-se essencial o desenvolvimento de dispositivos capazes de simular as condições fisiológicas de movimentos e cargas a fim de realizar testes in vitro que fornecerão dados para posteriormente serem testados in vivo. O objetivo deste trabalho é o desenvolvimento de dispositivos para a realização de testes in vitro com coluna vertebral. Estes dispositivos constam de uma máquina capaz de simular o movimento de flexão-extensão, pré-cargas axiais e a angulação pélvica, e uma lâmina de extensometria para captar as deformações dos tecidos testados. Foram realizados experimentos com discos invertebrais suínos a fim de avaliar a eficiência dos dispositivos. Realizaram-se dois experimentos usando os dispositivos desenvolvidos e um experimento na máquina universal de ensaios. Como resultado obteve-se valores de propriedades mecânicas coerentes com a literatura e o disco intervertebral comportando-se como um material viscoelástico. Outro ponto importante foi a obtenção da pressão intradiscal aproximada relacionando-a com o deslocamento angular da coluna. Conclui-se que os dispositivos apresentaram funcionamento satisfatório, abrindo perspectivas para outros estudos. / The best way to understand the degenerative mechanisms of the vertebral column and to evaluate appropriated methods for its treatment it is necessary to know the behavior of the diverse components of the intervertebral joints. So, it becomes essential to simulate the physiological conditions of movements and loads in order to carry through test in vitro that they will supply datas to be tested in vivo. The objective of this study is the development of devices of low cont for the accomplishment of tests in vitro with spine. These devices consist of a machine capable to simulate the movement of flexion-extension, daily pay-loads and the pelvic inclination, and an extensometry blade to catch the deformations of tested structures. POrcine had been carried through experiments with intervertebral discs in order to evaluate the efficiency od the devices. Two experiments had been become fullfilled using the developed devices and an experiment in the universal test machine. As result we got values of coherent mechanical properties with literature and the intervertebral disc behaving as a viscoelastic material. Another important point was the attainment of the intradiscal pressure approached relating it with the angular displacement of the spine. It is concluded that the devices had presented satisfactory functioning, opening perspective for other studies.
216

Hallazgos característicos de hernia discal lumbar diagnosticado por resonancia magnética en pacientes con lumbalgia en el Hospital PNP Luis N. Saenz, Lima. Enero- julio 2017

Surichaqui Montalvo, Milagros Levy January 2018 (has links)
Determina los hallazgos característicos de hernia discal lumbar diagnosticada por resonancia magnética en pacientes con lumbalgia. Realiza un estudio de tipo observacional, con diseño descriptivo, retrospectivo de corte transversal. La muestra está conformada por 140 informes radiológicos de columna lumbar por resonancia magnética de pacientes con hernia discal lumbar en el Hospital Nacional PNP Luis N. Sáenz de enero a julio en el año 2017. Se utilizó la historia de 140 pacientes. De estos pacientes, 77 fueron hombres (55 %) y 63 fueron mujeres (45%). En lo que se refiere al grupo de edades, siendo el intervalo más frecuente de 60 a más años con 56 personas (37,9%), prominencia anular difusa (32.9 %) fue la más diagnosticada. Con respecto a la localización de la hernia, la frecuencia más alta fue de (23,9 %) entre las vértebras L4-L5. Según su ubicación en el plano axial, se encontró en un mayor porcentaje (81.4%) en la ubicación foraminal y según los cambios de degeneración de hernia discal lumbar (Cambios Modic) diagnosticadas, la frecuencia más alta le correspondió a Cambios Modic tipo I (62.5%). Los hallazgos característicos de hernias discales lumbares diagnosticado por resonancia magnética en pacientes con lumbalgia, fueron de prominencia anular difusa, de localización en L4-L5, foraminal, y de cambios Modic tipo I. Hubo predominio en edades de 60 años a más, siendo el sexo femenino el más frecuente. / Tesis
217

Desenvolvimento de um macromodelo biomecânico tridimensional da coluna vertebral durante tarefas de levantamento

La Torre, Marcelo January 2009 (has links)
As atividades desenvolvidas pelo ser humano traduzem-se em grandes esforços internos, sobre as mais variadas estruturas corporais. O conhecimento da magnitude destes esforços pode auxiliar profissionais da área da saúde em atividades como prescrição de exercícios, reabilitação e prevenção de lesões. A magnitude dos esforços internos pode ser obtida por meio de um método direto ou indireto. O método direto esbarra em questões éticas e limitações tecnológicas, enquanto que o método analítico indireto por meio do conhecimento de parâmetros biomecânicos externos pode inferir sobre os esforços internos. Assim o objetivo deste estudo foi implementar um Macromodelo biomecânico tridimensional da coluna vertebral (MM3D), para cálculo das forças internas, articular e muscular resultantes, durante diferentes tarefas de levantamento de carga. O MM3D implementado consiste de um modelo de segmentos articulados (MSA-3D) o qual é composto por dezesseis segmentos rígidos conectados associados a um Modelo de distribuição (MDFMA) o qual fornece as forças musculares (FM) e articulares (FA) resultantes em três níveis da coluna vertebral (superior, médio e inferior). No MSA-3D as forças e momentos proximais líquidos são obtidos a partir da resolução das equações de movimento de Newton-Euler por meio da solução inversa. Com base nas forças e momentos proximais líquidos obtidos do MSA-3D o MDFMA baseado em técnicas de otimização e dados da literatura fornece as FM e FA resultantes na coluna vertebral. A tarefa avaliada consistiu do levantamento de um objeto com 20% da massa corporal do indivíduo em três diferentes técnicas de levantamento. Para registro cinemático foram utilizadas cinco câmeras digitais, com freqüência de amostragem de 25 Hz. O registro cinético foi realizado por meio da utilização de uma plataforma de força, a base de strain-gauges. Os resultados do MM3D implementado foram avaliados por meio da estimativa da acurácia da medida tridimensional obtida pela cinemetria, pela comparação dos resultados do MSA-3D com os valores mensurados pela plataforma de força, pela comparação da FRP e MP calculados pela via superior e inferior do MSA-3D nos segmentos da coluna vertebral e literatura. Os resultados obtidos sugerem uma coerência do MM3D com informações de mensurações diretas e estimativas indiretas obtidas da literatura. Assim o MM3D se mostrou capaz de avaliar e comparar as FM e FA nos três segmentos da coluna vertebral durante diferentes tarefas de levantamento. / Activities performed by the human being can be translated in large internal loads in the most varied body structures. Knowledge of these loads' magnitude may help health area professionals in activities such as prescription of exercises, rehabilitation and prevention of injuries. Internal load's magnitude may be obtained through direct or indirect methods. Direct method stumbles in ethical questions and technology limitations, while indirect analytic method through knowledge of external biomechanics parameters may deduce internal loads. Thus the objective of this study was to implement a tridimensional biomechanical macromodel of the spine (MM3D) to calculate internal forces, joint and muscular resultants, during different tasks of weight lifting. The implemented MM3D consists of an articulated segments model (MSA-3D) composed by sixteen rigid segments connected associated to a distribution Model (MDFMA) that provides resultant muscle (FM) and joint (FA) forces in three levels of the spine (superior, medium and inferior). At the MSA-3D liquid forces and proximal moments are obtained from the resolution of Newton-Euler movement equations through inverse solution. Based in the MSA-3D liquid forces and proximal moments obtained, the MDFMA, based in optimization techniques and data from literature, provides spine resultants FM and FA. The evaluated task consisted of lifting an object with 20% of the subjects' body weight using three different lifting techniques. For kinematics records five digital video cameras were used, with sampling frequency of 25 Hz. Kinetic record was performed using a force platform (strain-gauges based). MM3D implemented results were evaluated through accuracy estimation of the tridimensional measures obtained from kinematics, through comparison of the MSA-3D results and values measured by the force platform, through comparison of spine's segments calculated proximal resultant force and proximal moment calculated through upper and lower ways of MSA-3D and literature. Results suggest a coherence of direct measured information of MM3D and indirect estimative obtained from literature. Thus MM3D showed capable of evaluating and comparing FM and FA at the spine's three segments during different lifting tasks.
218

Modelo biomecânico tridimensional para análise das forças internas atuantes na coluna cervical superior e inferior durante o ciclismo

Pasini, Maicon January 2009 (has links)
Elevados índices de dor cervical e lombar têm sido reportados em ciclistas. Fatores como a postura adotada na bicicleta, a ativação dos músculos extensores da coluna e a ação de cargas mecânicas nas estruturas da coluna tem sido apontados como possíveis causas da dor. Embora relatados e aparentemente aceitos, poucos estudos objetivaram investigar estes fatores. Em adição, a dor crônica não específica é frequentemente diagnosticada em ciclistas, pois poucas evidências de anormalidade são observadas quando realizados exames radiológicos clínicos. O emprego de métodos biomecânicos de investigação, como a estimativa da magnitude da força muscular dos extensores da coluna e da força articular em diferentes níveis da coluna poderia contribuir para avaliação do risco de lesão e dor em decorrência do ciclismo, além de auxiliar na criação de estratégias de prevenção e programas de reabilitação. Assim, este estudo teve como objetivo quantificar e comparar as forças internas atuantes na coluna cervical durante o ciclismo em diferentes posturas, por meio do desenvolvimento e aplicação de um modelo biomecânico tridimensional in vivo. O modelo biomecânico proposto foi composto por dois segmentos rígidos (coluna cervical superior e inferior) conectados. O segmento coluna cervical superior compreende a cabeça, C1 e C2. O segmento coluna cervical inferior compreende as vértebras cervicais de C3 a C7. No segmento coluna cervical superior são considerados dois vetores de força muscular: FM1 (rectus capitis posterior major, rectus capitis posterior minor, obliquus capitis superior e obliquus capitis inferior) e FM2 (semispinalis capitis e splenius capitis). Já no segmento coluna cervical inferior estão inclusos os vetores FM3 (semispinalis cervicis) e FM4 (splenius cervicis). A resolução das equações de movimento de Newton-Euler é realizada por meio da solução inversa. Os parâmetros cinemáticos foram obtidos utilizando imagens externas da cabeça e coluna cervical, adquiridas por meio de quatro câmeras de vídeo digital com frequencia de amostragem de 25 Hz. Para estimar a localização dos centros de rotação (C2-3 e C6-7) foram realizados exames radiológicos convencionais estáticos. Os parâmetros de massa e centro de massa foram retirados de tabelas antropométricas da literatura. Participaram do estudo 12 ciclistas com pelo menos dois anos de experiência competitiva cada. O estudo foi aprovado pelo Comitê de Ética em Pesquisa da Universidade Federal do Rio Grande do Sul e os sujeitos assinaram um termo de consentimento livre e esclarecido. Cada participante foi avaliado utilizando sua própria bicicleta acoplada a um ciclossimulador magnético, em duas etapas realizadas no mesmo dia. Inicialmente foi mensurada a massa corporal total do individuo e em seguida identificados e marcados 14 pontos anatômicos de interesse com uma caneta dermatográfica. Durante as avaliações foram fixos marcadores revestidos com papel reflexivo e contendo chumbo no interior em todos os pontos anatômicos de interesse. Na Etapa I os sujeitos pedalaram durante 2 minutos em cada postura (ereta, descanso, intermediária, ataque e cotovelos flexionados), sendo coletados dados cinemáticos durante os últimos 30 segundos de cada uma. Na Etapa II foram realizados exames radiológicos estáticos em cada uma das 5 posturas analisadas (ereta, descanso, intermediária, ataque e cotovelos flexionados) e em flexão e extensão máximas da coluna cervical. Os resultados indicam que as forças internas atuantes nas estruturas da coluna cervical apresentaram maiores magnitudes nas posturas que envolvem a prática do ciclismo (descanso, intermediária, ataque e cotovelos flexionados), quando comparadas a postura de referência (ereta). Observando somente as posturas que envolvem o ciclismo, as forças internas aumentaram gradativamente a medida que os ciclistas transferiram o apoio de suas mãos da região superior para a região inferior do guidão, adotando as posturas descanso, intermediária e ataque, respectivamente. Entretanto, as maiores magnitudes das forças internas foram observadas quando os ciclistas efetuaram o apoio das mãos envolvendo os manetes e flexionaram a articulação do cotovelo (postura cotovelos flexionados). Proporcionalmente os maiores aumentos das forças internas ocorreram na coluna cervical superior, porém as maiores magnitudes das forças internas foram alcançadas na coluna cervical inferior. O processo de avaliação demonstrou que o modelo biomecânico tridimensional da coluna cervical proposto foi considerado capaz de representar de maneira confiável o sistema de interesse. Os resultados encontrados são coerentes, sendo o modelo um instrumento adequado para estimar as forças internas atuantes na coluna cervical durante o ciclismo em diferentes posturas. / High index of cervical and lumbar pain had been registered in cyclists. Factors as a posture adopted on bicycle, the activity of spine extensor muscles and the action of mechanical load in the spine structures had been put like possible causes of pain. Although related and apparently accepted, few studies investigate these factors. In addition, the non-specific chronic pain is frequently diagnosed in cyclists, because few evidences of abnormalities are investigated when clinic radiologics exams are done. The use of biomechanical methods of investigation, like the estimate of muscular force magnitude of extensors of spine and of joint force in different levels of spine can be contributed to evaluation of injury risk and pain caused by cycling, beyond the assist in strategies of prevention and rehabilitation programs. Therefore, this study had like objective to quantify and compare the active internal forces in the cervical spine during cycling in different postures, through development and application of three dimensional in vivo biomechanical model. The biomechanical model suggested was compound by two rigid segments (upper and lower cervical spine) connected. The upper cervical spine segment include head, C1 and C2. The lower cervical spine segment include cervical vertebraes of C3 to C7. In the upper cervical spine segment are considered two vectors of muscular force: FM1 (rectus capitis posterior major, rectus capitis posterior minor, obliquus capitis superior e obliquus capitis inferior) and FM2 (semispinalis capitis e splenius capitis). In the lower cervical spine segment are included the vectors FM3 (semispinalis cervicis) and FM4 (splenius cervicis). The resolution of movement equation of Newton-Euler is done through inverse dynamics. The kinematic parameters were obtained using external images of head and cervical spine, acquired by four digital video cameras with sampling frequency of 25 Hz. To estimate the location of rotation centers (C2-3 and C6-7) statics conventional radiologic exams were done. The parameters of mass and center of mass were removed of anthropometric tables of literature. 12 cyclists with at least two years of competitive experience each one participated of the study. The study was approved by Ethics Committee in Researches of Federal University of Rio Grande do Sul and the subjects signed a free and clear consent term. Each participant was assessed using your bicycle attached in a magnetic cycle simulator, in two stages done in the same day. Initially the total body mass of subjects was measured and then 14 anatomic points of interest were identified and marked with a dermatography pen. During the evaluation markers encased with reflective paper and containing lead inside of these markers were fixed in all anatomic points of interest. In the stage I the subjects rode a bicycle during 2 minutes in each posture (upright neutral, rest, intermediate, attack and flexed elbows). The kinematic data were collected during the last 30 seconds of each one. In the stage II static radiologic exams were done in each of 5 analyzed postures (upright neutral, rest, intermediate, attack and flexed elbows) and in maxim flexion and extension of cervical spine. The results indicate that the internal forces active in the structures of cervical spine presented more magnitudes in the postures that involve the cycling practice (rest, intermediate, attack and flexed elbows), when compared to reference posture (upright neutral). Observing just the postures that involve the cycling, the internal forces gradually increased as cyclists transferred the your hands from upper to lower region of handlebar, adopting the rest, intermediate and attack postures, respectively. However, the greater magnitude of internal forces were observed when the cyclists hands involving the brake levers and flexed the elbow joints (flexed elbows posture). Proportionally the greatest increase of internal forces occurred in the upper cervical spine, however the greatest magnitudes of internal forces were reached in the lower cervical spine. The evaluation process demonstrated that the three dimensional biomechanical model of cervical spine was considered able to represent of reliable way the interest system. The results found are coherent, the model is an adequate instrument to estimate the internal forces active in the cervical spine during cycling in different postures.
219

Análise morfométrica dos pedículos toracolombares de pacientes da Região Sul do Brasil / Ana Paula Massuda Valadão de Oliveira ; orientador, Luiz Roberto Aguiar

Oliveira, Ana Paula Massuda Valadão de, 1971- January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f. 139-150 / A instrumentação com parafusos pediculares representa um dos mais importantes avanços técnicos na cirurgia de coluna, desde sua descrição em 1959. A correta aplicação desta técnica depende muito da anatomia e morfometria dos pedículos. Vários estudos popu / First described in 1959, pedicle screw instrumentation remains one of the most important technical advances in spinal surgery. Effective application of the technique depends greatly on pedicle anatomy and morphometry, which several studies have shown to v
220

Sistema para aplicação e avaliação do treinamento locomotor com suporte parcial de peso na lesão medular / Ericson Pereira ; orientadora, Elisangela F. Manffra ; co-orientador, Luiz Roberto Aguiar

Pereira, Ericson January 2009 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f. 126-134 / O treino locomotor com suporte de peso (TLSP) é um método de reabilitação aplicado na lesão medular para estimular a recuperação da capacidade muscular, evitar a atrofia e restabelecer a capacidade de sustentar um percentual do peso corporal. O treino con / The body weight support training (BWST) is a method for rehabilitation of spinal cord injury which aims at stimulating muscle capacity recovery and preventing atrophy. Moreover, it might restore the capacity of supporting body weight partially. The method

Page generated in 0.0711 seconds