Return to search

Avaliação do desajuste marginal de coroas totais fundidas em titanio comercialmente puro utilizando diferentes padrões para fundição / Evaluation of marginal misfit of casting commercially pure titanium total crow using differrent pattern for casting

Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T02:52:52Z (GMT). No. of bitstreams: 1
Torres_JoseWalterMurta_M.pdf: 1252099 bytes, checksum: 8a9ecb06692b975d77a7808edbe5eeec (MD5)
Previous issue date: 2005 / Resumo: Padrões de fundição de restaurações protéticas metálicas são usualmente confeccionados em cera. Todavia, especula-se que possa haver aumento nos valores de desajuste marginal, causado por alterações dimensionais ocorridas quando da remoção dos padrões previamente à inclusão em revestimento. Assim, a resina acrílica quimicamente ativada tornou-se uma opção e seu uso rotineiro em laboratórios comerciais. O titânio possui propriedades como biocompatibilidade, baixa condutividade térmica, baixo custo e alta resistência mecânica, tornando-se o material preferido para implantes e o foco de inúmeros estudos visando seu uso em restaurações e coroas protéticas. Visando o menor desajuste marginal possível é recomendado pelo fabricante do sistema de fundição de titânio o uso de cera para a confecção dos padrões, não havendo avaliações do uso de resina acrílica para este fim. Foi propósito deste estudo comparar o desajuste marginal de coroas unitárias fundidas em titânio comercialmente puro (Ti CP - Tritan; Dentaurum, Alemanha), utilizando-se cera (como controle) e as resinas acrílicas Duralay (Reliance Dental Mfg, Co., EUA) e Pattern Resin (GC America Inc., EUA) na confecção dos padrões. Dez dentes bovinos foram preparados para restaurações tipo coroa total, moldados com silicone e replicados em gesso tipo IV. Dez padrões de fundição com 0,7 mm de espessura foram confeccionados para cada grupo (n=10). As coroas foram fundidas em titânio comercialmente puro em máquina de fundição por plasma e vácuo. Após a fundição, as coroas foram removidas do revestimento e ajustadas nos troquéis e nos dentes correspondentes. Para a leitura dos desajustes marginais foi utilizado um microscópio de medição com precisão de 0,5µm, sendo efetuadas 3 leituras em cada conjunto padrão/dente preparado. Os valores obtidos foram tabulados e submetidos à análise de variância e ao teste de Tukey ao nível de 5% de probabilidade. Foram verificados desajustes de 151µm para as coroas fundidas a partir dos padrões em cera, de 153µm para os padrões obtidos em resina Duralay e de 165µm para as fundições obtidas por padrões em resina Pattern. Não foram verificadas diferenças significativas entre os grupos avaliados, estando estes dentro de valores próximos a 150µm / Abstract: Patterns for casting metallic restorations are usually obtained from wax. However, it is speculated that increased marginal misfits could be created caused by dimensional changes during the removal of the pattern from the cast. Therefore, chemically activated acrylic resin is a routinely option in dental commercial laboratories. The characteristics of titanium include biocompatibility, low thermal conductivity, low cost and high mechanical resistance becoming the material of choice for implants and the focus of innumerous studies in prosthetic field such as crowns. To obtain the lowest marginal misfit in crowns, it is recommended that titanium appliances should be cast using wax as pattern, with no evaluation on the use of acrylic resin for this purpose. The aim of this study was to compare the marginal adjustment of crowns cast in commercially pure titanium (CP Ti - Tritan; Dentaurum, Germany)using wax (control), and the acrylic resins Duralay (Reliance Dental, Mfg Co., USA) and Pattern Resin (GC America Inc., USA) as patterns. Ten bovine teeth were prepared for full crown restorations. Impressions were made in silicone material and replicated in type IV dental stone. Ten 0.7 mm-casting patterns were made for each groups. The crowns were cast in CP Ti in a plasma-vacuum casting machine. After casting, the crowns were removed from the investment and adjusted on the respective preparation. For the marginal misfit readings, a 0.5µm-traveling microscope was used. Three readings were taken from each crown-preparation interface. The means were calculated and submitted to analysis of variance and Tukey test at 5% probability lever. Misfits of 151µm were obtained for the crowns cast using wax as patterns; 153µm when Duralay was used; and, 165µm for the crowns made from Pattern Resin. No significant differences were seen among the groups, and the values about 150µm / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289187
Date09 January 2005
CreatorsTorres, Jose Walter Murta
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Henriques, Guilherme Elias Pessanha, 1968-, Junior, Manoel Gomes Troia, Nóbilo, Mauro Antonio de Arruda
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format59f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0034 seconds