Risco para contaminação de artigos: uma proposta de diagnóstico de enfermagem

Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2015-12-21T12:03:29Z
No. of bitstreams: 1
Raquel Calado da Silva Gonçalves.pdf: 1984853 bytes, checksum: 24758c95e14e6b3d50284303fec3a219 (MD5) / Made available in DSpace on 2015-12-21T12:03:29Z (GMT). No. of bitstreams: 1
Raquel Calado da Silva Gonçalves.pdf: 1984853 bytes, checksum: 24758c95e14e6b3d50284303fec3a219 (MD5)
Previous issue date: 2013 / Mestrado Profissional em Enfermagem Assistencial / Introdução: Objetivos: Geral: Validar em forma e conteúdo a proposta
diagnóstica “Risco para contaminação de artigos”. Específicos: Identificar a
proposta diagnóstica a partir da revisão integrativa da literatura; identificar os
fatores de risco, bem como a pertinência dos títulos, conceitos e a disposição em
domínios, através da análise por especialistas. Método: Estudo de validação,
seguindo o método de validação de conteúdo, realizado em duas etapas: 1 -
Análise do conceito e revisão integrativa; 2 - Validação de conteúdo por
especialistas. Utilizou-se a definição da estimativa do tamanho amostral e a
proporção esperada de peritos composta por 38 enfermeiros, considerando-se um
erro amostral aceitável de 15%, nível de confiança de 99% e proporção de
especialistas de 85% para validação do diagnóstico. Estes responderam
Instrumento de validação do tipo likert, contendo os itens a serem validados e sua
definição para os seguintes critérios: Adequação; Pertinência; Clareza; Precisão;
e Objetividade. Para análise dos dados calculou-se o número de especialistas que
consideraram adequado o indicador clínico, com aplicação do teste estatístico
binominal. Ressalta-se à apreciação do Comitê de Ética em Pesquisa local, sob o
número CAAE: 04960612.5.0000.5243. Resultados: Obteve-se concordância
entre o proposto e o validado pelos peritos, com escore acima de 0,80, para os
itens: Domínio, Falha na bomba de vácuo; Uso de autoclaves sem o controle microbiológico; Esterilização de cargas sem o uso do pacote teste desafio (PCD); Limpeza manual de instrumental com lúmen; Utilização de autoclaves sem a realização periódica de manutenções preventivas e/ou corretivas; Pacotes não identificados corretamente; Armazenamento dos pacotes estéreis em área não restrita; e Transporte dos pacotes estéreis em carro de transporte aberto. A presença e a detecção precoce de falhas no maquinário mostraram-se relevante
tanto na literatura como na avaliação dos peritos: ‘Falha na bomba de vácuo’,
‘Uso de autoclaves sem o controle microbiológico’, ‘Esterilização de cargas sem o uso do pacote teste desafio (PCD)’ e ‘Utilização de autoclaves sem a realização periódica de manutenções preventivas e/ou corretivas’. Classificaram-se como menores (escore geral entre 0,71 e 0,79) os itens Classe; Enunciado diagnóstico; Definição; Presença de sujidades no artigo após a limpeza; Parâmetros físicos inadequados ao final do ciclo; Falha no indicador químico após a esterilização;
Uso de material implantável antes do resultado do indicador biológico; e,
Esterilização de implantes em ciclo para uso imediato. Outros dois itens não
foram validados: ‘Parâmetros físicos inadequados ao final do ciclo’ e o ‘Falha no indicador químico após a esterilização’, que obtiveram valores marginais de 0,76 e 0,78, respectivamente. Os itens Definição (0,0066) e ‘Esterilização de implantes
em ciclo para uso imediato’ (0,0396), foram classificados como inadequado pelos peritos. Conclusões: Conclui-se que a proposta diagnóstica “Risco para
contaminação de artigos” está adequada, uma vez que os peritos validaram os itens propostos. Dois itens foram considerados inadequados e devem ser revisados antes da submissão e da validação clínica / Introduction: Objectives: General: Validating in form and content the diagnostic proposal "risk for contamination of articles". Specifics: Identifying the proposal from
the integrative review diagnostic of literature; identify the risk factors, as well as the relevance of the titles, concepts and disposition in domains, through analysis by experts. Method: A validation study, following the content validation method, performed in two steps: 1-concept analysis and integrative review; 2-content validation by experts. It was used the definition of sample size estimate and the expected proportion of experts composed by 38 nurses, considering an acceptable
sampling error of 15%, 99% confidence level, and proportion of specialists 85% for validation of the diagnosis. These answered as Instrument of validation of Likert type, containing the items to be validated and its definition to the following criteria: Suitability; Relevance; Clarity; Precision; and Objectivity. For data analysis it was calculated the number of specialists who considered appropriate the clinical indicator, with application of the binomial statistical test. It was emphasized to the local Research Ethics Committee, under the CAAE number: 04960612.5.0000.5243. Results: An agreement was obtained between the proposed and the validated by experts, with score above 0.80, for the items: domain, vacuum pump failure; Use of autoclaves without the microbiological control; Sterilization of loads without the use of challenge test package; Manual cleaning of instruments with lumen; Use of autoclaves without performing periodic
preventive and/or corrective maintenance; Unidentified packages correctly; Storage of sterile packages in unrestricted area; and transport of sterile packages in open transport car. The presence and the early detection of faults in machinery were relevant both in literature as in the assessment of the experts: ' vacuum pump failure ', ' use of autoclaves without the microbiological control ', ' sterilization
of loads without the use of challenge test package (PCD) ' and ' use of autoclaves without performing periodic preventive and/or corrective maintenance '. Qualified as minors (General score between 0.71 and 0.79) the Class items; Statement diagnosis; Definition; Presence of dirt in the article after cleanup; Inadequate
physical parameters at the end of the cycle; Chemical indicator failed after
sterilization; Use of implantable material before the biological indicator's result; and implant Sterilization cycle for immediate use. The other two items were not validated: ' inappropriate physical parameters at the end of the cycle ' and the ' chemical indicator failed after sterilization, which achieved marginal values of 0.76 and 0.78, respectively. The items Definition (0.0066) and 'implant Sterilization in
cycle for immediate use' (0.0396) were classified as inadequate by the experts.
Conclusions: it is concluded that the proposed diagnosis "Risk for contamination of articles" is appropriate, since the experts validated the proposed items. Two items were considered inappropriate and should be reviewed before submission and clinical validation

Identiferoai:union.ndltd.org:IBICT/oai:https://app.uff.br/riuff:1/1223
Date January 2013
CreatorsGonçalves, Raquel Calado da Silva
ContributorsSilva, Maria Virgínia Godoy da, Santana, Rosimere Ferreira
PublisherUniversidade Federal Fluminense, Niterói
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFF, instname:Universidade Federal Fluminense, instacron:UFF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0031 seconds