Return to search

Estudo da aplicação de redes neuronais artificiais para apoio à decisão na liberação do perfil lipídico e de glicemia em jejum.

Orientadora : Profª Drª Jeroniza Nunes Marchaukoski / Co-Orientador: Prof. Dr. Geraldo Picheth / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Educação profissional e Tecnológica, Programa de Pós-Graduação em Bioinformática. Defesa: Curitiba, 21/02/2011 / Bibliografia: fls. 84-88 / Resumo: As determinações do perfil lipídico (colesterol total, HDL-colesterol, LDL-colesterol, triglicérides) e da glicemia em jejum são ensaios de grande demanda nos laboratórios clínicos. A liberação destes resultados por profissionais consome tempo e atenção. O estudo se propõe avaliar a aplicação das redes neuronais, Multilayer Perceptron (MLP) e Free Associative Neurons (FAN), como ferramentas de inteligência artificial para colaborar na liberação dos resultados, em processo designado "segunda opinião". O projeto tem a aprovação do Comitê de Ética em Pesquisa com Seres Humanos do HC-UFPR (CAE: 0253.0.208.000-10). Uma amostra contendo 60.006 registros obtidos do banco de dados do HC-UFPR foi analisada. A idade média dos pacientes foi cerca de 47 anos (amplitude de variação de 2 a 99 anos), com predomínio de mulheres (~65%). Esta amostra foi classificada em "liberado" quando todo os valores dentro dos critérios estabelecidos de normalidade e "retido" quando qualquer analito estudado se mostrou fora da referência. Esta classificação resultou em 62% da amostra classificada no grupo "retido". Quando as redes neuronais foram testadas com arquivos completos (n=30.003) a rede FAN apresentou divergência cerca de 6 vezes superior à rede MLP (7,6% vs. 1,2%) embora ambas tenham um desempenho satisfatório em acurácia (>90%). Foram treinadas e testadas as redes FAN e MLP com arquivos incompletos, aracterizados pela ausência de algum dos parâmetros em estudo com diferentes tamanhos de arquivos (30.536, 65.536 e 120.000 registros). Nesta condição que mimetiza os resultados liberados pelo laboratório clínico, a rede neuronal MLP apresentou desempenho superior à rede FAN. O estudo permitiu concluir que: (1) a rede neuronal FAN perde desempenho com arquivos incompletos, (2) a rede neuronal MLP apresentou desempenho superior à rede FAN quando estudada com arquivos completos ou incompletos, (3) o tamanho amostral utilizado para treinamento e teste não afetaram o desempenho da rede neuronal MLP, enquanto que a rede FAN é afetada por perda de sensibilidade, (4) resultados divergentes da rede neuronal MLP avaliados por especialistas humanos evidenciaram que os ensaios com valores alterados foram o principal elemento de inconsistência. Em síntese, a rede neuronal MLP é recomendada para outros estudos com desenho amostral semelhante e apresenta potencial para aplicação no laboratório clínico como suporte a decisão na liberação de resultados. / Abstract: The lipid profile (total cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides) and fasting blood glucose are tests of high throughput in clinical laboratories. In the process of liberate these results professionals needs to takes time and attention. The study aims to evaluate the application of neural networks, Multilayer Perceptron (MLP) and Free Associative Neurons (FAN), as artificial intelligence tools to assist in the release of the results, a process called "second opinion". The project was approved by the Ethic Committee in Human Research of the HC-UFPR (CAE: 0253.0.208.000-10). A sample containing 60,006 registers obtained from HC-UFPR Database was analyzed. The mean age of patients was about 47 years (range: 2-99 years) with predominance of women (~65%). This sample was classified as "released", when all values were within the established criteria of normality and "retained" when any studied analyte showed values outside the reference of normality. This classification resulted in 62% of the sample classified as "retained". When neural networks were tested with complete files (n=30,003) FAN network disagreement was about 6 times higher compared with the MLP network (7.6% vs. 1.2%) although both have a
satisfactory performance in accuracy (> 90%). The FAN and MLP networks were also trained and tested with incomplete files, characterized by the absence of any of the parameters under study with different file sizes (30,536, 65,536 and 120,000 registers). In this condition that mimics the results released by a clinical laboratory, the MLP neural network showed a superior performance compared to the FAN network. The study concluded that: (1) the FAN neural network loses performance with incomplete files, (2) the performance of MLP neural network was superior to the FAN network when tested with complete or incomplete files, (3) the sample size used to training and testing did not affect the performance of MLP neural network, while FAN network that is affected by loss of sensitivity, (4) divergent results of the MLP neural network evaluated by human experts showed that the tests with high values were the main element of inconsistency. In summary, the MLP neural network is recommended for other studies with similar sample design and presents a potential for application in the clinical laboratory as a decision support system.

Identiferoai:union.ndltd.org:IBICT/oai:dspace.c3sl.ufpr.br:1884/48063
Date January 2011
CreatorsPrado, Ademir Luiz do
ContributorsMarchaukoski, Jeroniza Nunes, 1973-, Picheth, Geraldo, 1955-, Universidade Federal do Paraná. Setor de Educação Profissional e Tecnológica. Programa de Pós-Graduação em Bioinformática
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format99f. : il. [algumas color.], grafs., tabs., application/pdf
Sourcereponame:Repositório Institucional da UFPR, instname:Universidade Federal do Paraná, instacron:UFPR
Rightsinfo:eu-repo/semantics/openAccess
RelationDísponivel em formato digital

Page generated in 0.0108 seconds