Return to search

Medição minimamente invasiva da pressão vesical no homem : instrumentação e aplicação clínica / Minimally invasive measurement of vesical pressure in men : instrumentation and clinical application

Orientador: José Wilson Magalhães Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T12:41:31Z (GMT). No. of bitstreams: 1
Almeida_JoaoCarlosMartinsde_M.pdf: 13918269 bytes, checksum: 78378428b79af0919ecab395a454bf98 (MD5)
Previous issue date: 2014 / Resumo: O estudo urodinâmico tem importante papel na determinação da necessidade de pacientes portadores de sintomas do trato urinário inferior (STUI) se submeterem à cirurgia da próstata. O estudo pressão-fluxo pode contribuir muito para a quantificação dos STUI, porém é invasivo, demorado e de custo elevado. Métodos alternativos têm sido desenvolvidos procurando minimizar o procedimento invasivo necessário para medição da pressão vesical. Um método alternativo foi desenvolvido no Centro de Engenharia Biomédica da UNICAMP e consiste num dispositivo denominado conector uretral (Pat. N. PI 0502171-5). Trata-se de um dispositivo cilíndrico e vazado, que permite o escoamento de urina por seu interior. O paciente é orientado a introduzir o conector na uretra antes de iniciar a micção e, ao urinar, solicitado a ocluir a saída do dispositivo, interrompendo o fluxo urinário por um curto intervalo e permitindo o registro da pressão dentro da bexiga urinária. Neste trabalho, uma instrumentação e uma nova versão do conector uretral foram desenvolvidas para medir a pressão vesical em homens. Aplicado em testes clínicos em indivíduos com sintomas de obstrução infravesical decorrente de hiperplasia benigna da próstata, o conjunto demonstrou capacidade de diferenciar indivíduos com obstrução de indivíduos não obstruídos sem diferença significativa do que se obtém no estudo pressão-fluxo (p > 0,05). O conector apresentou sensibilidade e especificidade de 66,7%, valores similares aos dos métodos alternativos descritos na literatura. Além disso, 88,5% dos indivíduos relataram preferir o conector uretral ao estudo pressão-fluxo, indicando a importância do conector como método alternativo minimamente invasivo ao estudo urodinâmico convencional / Abstract: Urodynamic assessment has an important role in the decision of patients complaining of lower urinary tract symptoms (LUTS) to undergo prostate surgery. Pressure-flow study may contribute to the evaluation of LUTS, but its procedure is invasive, time-consuming and expensive. Alternative methods have been developed aiming at measuring vesical pressure in a less invasive manner. An alternative method was developed in the Center for Biomedical Engineering at UNICAMP and consists of a device named urethral connector (Pat. N. PI 0502171-5). The device has a cylindrical shape and an internal longitudinal hole that permits urine to pass through it. The patient is instructed to insert the urethral connector into his urethra before starting to urinate. During micturition, he is instructed to occlude the urine outlet of the device for a short period of time so that vesical pressure may be measured. In this work, an instrumentation and a new version of the urethral connector were developed to measure vesical pressure in men. The device and instrumentation were applied in clinical tests in individuals reporting LUTS secondary to infravesical obstruction due to benign prostatic hyperplasia. It was shown that this new method is capable of differentiating obstructed individuals from nonobstructed ones. Results were not significantly different from those obtained when conventional pressure-flow study was applied (p > 0.05). The urethral connector had a sensibility and specificity of 66.7%, values similar to those found by the alternative methods described in the literature. About 88.5% of the individuals evaluated reported to prefer the new method instead of the conventional assessment which reinforces the importance of the urethral connector as a less invasive and alternative method to the conventional urodynamic study / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259390
Date26 August 2018
CreatorsAlmeida, João Carlos Martins de, 1987-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bassani, José Wilson Magalhães, 1953-, Button, Sergio Tonini, Muhlen, Sérgio Santos
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format50 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds