Return to search

Avaliação da biocompatibilidade de magnetolipossomas à base de nanopartículas de maghemita

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Medicina, 2008. / Submitted by Priscilla Brito Oliveira (priscilla.b.oliveira@gmail.com) on 2009-09-25T17:33:51Z
No. of bitstreams: 1
Dissert_Julia Poubel Coelho.pdf: 2109130 bytes, checksum: b6ff6344b759c1414a4815506cedb27b (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2010-06-11T15:28:22Z (GMT) No. of bitstreams: 1
Dissert_Julia Poubel Coelho.pdf: 2109130 bytes, checksum: b6ff6344b759c1414a4815506cedb27b (MD5) / Made available in DSpace on 2010-06-11T15:28:22Z (GMT). No. of bitstreams: 1
Dissert_Julia Poubel Coelho.pdf: 2109130 bytes, checksum: b6ff6344b759c1414a4815506cedb27b (MD5)
Previous issue date: 2008 / A nanobiotecnologia consiste em um campo de pesquisa emergente e promissor.
Materiais nanoestruturados, tais como fluidos magnéticos e magnetolipossomas (ML), têm
sido propostos como sistemas de entrega de drogas e termoterapia contra o câncer, entre
outras aplicações em biomedicina. Em particular, ML são estruturas fisiologicamente estáveis,
constituídas por nanopartículas magnéticas (NPM) acondicionadas em uma bicamada
fosfolipídica. Uma amostra de ML contendo nanopartículas de maghemita recobertas com
citrato encapsuladas em lipossomas (denominada ML-Magh) foi sintetizada com propósitos
de aplicações biomédicas. Polietilenoglicol (PEG) foi associado à bicamada lipídica. A
proposta deste estudo foi investigar o comportamento biológico de ML-Magh (1,0 × 1014
partículas/ mL), avaliando sua biocompatibilidade/ toxicidade por meio de testes in vitro e in
vivo. O tamanho e o potencial de carga de superfície dos ML foram estudados e apresentaram
diâmetro médio de 124 nm e carga negativa (potencial zeta, -24,4 mV). Nos testes in vitro,
células ductais de glândula submandibular humana (HSG) e células mesangiais (CM) foram
cultivadas durante 24 horas na presença de ML-Magh em duas diferentes doses (50 mL and
100 mL). Análises por microscopia de luz mostraram que ML-Magh não induz alterações
morfológicas em ambos os tipos celulares. Para os testes in vivo, 100 mL de ML-Magh foram
endovenosa ou intraperitonealmente administrada em camundongos fêmeas Swiss (n=5-6).
Animais controle (n=3) foram tratados com solução salina tamponada por fosfato (PBS). Os
efeitos da amostra ML-Magh foram investigados de 30 minutos até 30 dias após
administração, dependendo do teste. A viabilidade de células peritoneais investigada por meio
de dois diferentes métodos, exclusão por Nigrosina e Iodeto de Propídio, não foi afetada. A
contagem de leucócitos do sangue indicou que ML-Magh não apresenta potencial próinflamatório.
Apenas um aumento na população de eosinófilos foi observado, uma hora após
administração de ML-Magh, sugerindo um ligeiro processo alérgico. A ausência de
genotoxicidade e citotoxicidade foi confirmada respectivamente, pelo teste de micronúcleo e
porcentagem de eritrócitos policromáticos. A análise histopatológica realizada em três tecidos
mostrou poucos agregados de NPM em pulmões e baço, e nenhum no fígado. Alterações
morfológicas não foram encontradas nestes tecidos durante todo o período experimental. Os
raros infiltrados inflamatórios observados após tratamento no fígado e nos pulmões também
foram vistos nos animais controle. Testes bioquímicos realizados no sangue mostraram
alterações irrelevantes, uma vez que as concentrações de alanina aminotransferase (ALT),
fosfatase alcalina (FA), uréia e creatinina foram constantes em quase todos os tempos após
administração de ML-Magh, sugerindo ausência de danos hepáticos e renais. A determinação
dos níveis de ferro sérico mostrou que ML-Magh não alterou significativamente os níveis de
ferro, exceto em testes com o dobro (200 mL) da concentração usual. Os dados sugerem que a
amostra investigada é biocompatível e tem potencial para ser usada em aplicações
biomédicas, especialmente como agentes na terapia contra o câncer, por meio da
magnetohipertermia ou sistemas de entrega de drogas. ________________________________________________________________________________________ ABSTRACT / Nanobiotechnology represents an emerging and promising research field.
Nanostructured materials, such as magnetic fluids and magnetoliposomes (MLs), have been
proposed for drug-delivery systems and thermal-based cancer therapy amongst other several
applications in biomedicine. In particular, MLs are physiologically stable structures,
consisting of magnetic nanoparticles (MNPs) wrapped by a phospholipid bilayer. A ML
sample containing citrate-coated maghemite nanoparticles encapsulated in liposomes (called
ML-Magh) was synthesized for biomedical applications purposes. Polyethylene glycol (PEG)
was grafted onto the liposome bilayer. The aim of this work was to investigate the biological
behaviour of ML-Magh (1,0 × 1014 particle/ mL), by evaluating their biocompatibility/
toxicity through in vitro and in vivo tests. The particle size and surface charge potential of
MLs were determined. They presented a mean particle size of 124 nm and a negative surface
charge, as determined by measuring the zeta potential (-24,4 mV). To perform the in vitro
test, human submandibular duct cells (HSG) and mesangial cells (CM) were cultivated during
24 hours in the presence of the ML-Magh sample at two different doses (50 mL and 100 mL).
Analysis by light microscopy showed that ML-Magh does not induce morphological
alterations on both cellular types. For the in vivo tests, 100 mL of the ML-Magh sample were
endovenously or intraperitoneally administrated to female Swiss mice (n=5-6). Control
animals (n=3) were treated with phosphate buffered saline (PBS). ML-Magh sample effects
were investigated from 30 minutes until 30 days after the administration. The viability of
peritoneal cells was not affected by the ML-Magh treatment, as investigated by two different
methods: nigrosin dye exclusion and propidium iodide exclusion. The leukocytes cytometry
indicated that ML-Magh has no pro-inflammatory action. The eosinophil population
presented an increase one hour after ML-Magh administration, suggesting a slight allergic
process. Absence of genotoxicity and cytotoxicity was confirmed by micronucleus test and
polychromatic erythrocyte percentage, respectively. The histopathology analysis performed in
three tissues showed few particle clusters in the lungs and spleen. Clusters were not observed
in the liver. No morphological alterations were found in these tissues during all the
experimental time. The rare inflammatory infiltration observed in the liver and lungs of MLMagh-
treated mice was also observed in control animals. Biochemical blood tests showed
irrelevant alterations. Concentrations of alanine aminotransferase (ALT), alkaline phosphatase
(ALP), urea, and creatinine were constant almost all over the experiment, suggesting no
hepatic or splenic injury. The levels of serum iron were not affected by ML-Magh treatment.
Nevertheless, serum iron levels are dose-dependent. Data suggest that the investigated sample
is biocompatible and it has potential to be used in biomedical applications, especially as
agents for anticancer therapy through magnetohyperthermia and drug delivery systems.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/4992
Date January 2008
CreatorsCoelho, Júlia Poubel
ContributorsLacava, Zulmira Guerrero Marques
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds