Return to search

Avaliação da agua e do sedimento das microbacias dos Ribeirões Graminha e Aguas da Serra na cidade de Limeira, SP / Evaluation of the water and the sediment of the microbasins of Brooks Graminha and Aguas da Serra in the city of Limeira, SP

Orientador: Silvana Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T03:52:29Z (GMT). No. of bitstreams: 1
Fazza_ElizeteVieira_M.pdf: 2172063 bytes, checksum: 9efe3c01da1dbb554288a537bfa44ea7 (MD5)
Previous issue date: 2007 / Resumo: A cidade de Limeira está localizada no Estado de São Paulo e possui economia expressiva, com indústrias em vários setores produtivos, entre elas, galvanoplastias voltadas para a produção de jóias, semijóias e bijuterias. Visando elucidar se há influência antropogênica nos mananciais da cidade, avaliou-se a qualidade das águas e as concentrações de metais presentes na água e nos sedimentos dos ribeirões Graminha e Águas da Serra, cujas nascentes estão na zona urbana de Limeira. As determinações de metais foram realizadas pela técnica de Fluorescência de Raios X por Reflexão Total com Radiação Síncrotron (SR-TXRF). Os limites de detecção para amostras de água estão na faixa de 0,50 a 0,05 µg.L-1 para Ca e Zn, respectivamente, enquanto que para as amostras de sedimento os limites de detecção obtidos foram iguais a 0,22 e 0,02 µg.g-1 para os mesmos elementos. Nas amostras de água dos dois mananciais e para ambos os períodos amostrados (seco e húmido) as concetrações de Al e Fe foram superiores aos limites máximos permissíveis estabelecidos pela legislação vigente. Os elementos Zn e Cu apresentaram o mesmo comportamento. Para o Cr e Ni apenas alguns pontos de amostragem apresentaram valores acima dos limites permitidos. No ribeirão Águas da Serra os valores foram superiores ao permitido para todos os pontos exceto pra dois pontos no período seco, enquanto que para o ribeirão Graminha os resultados foram superiores para quatro pontos no período úmido. Nas amostras de sedimento o elemento Cu ultrapassou o valor estabelecido pela legislação em ambos os mananciais. Os valores para Pb nas amostras de sedimento também foram ultrapassados para todas as amostras do ribeirão Águas da Serra e em alguns pontos do Graminha. Os resultados obtidos para Cr foram excedidos em três pontos no período húmido e em dois pontos no período seco para o ribeirão Águas da Serra, e no Graminha apenas no período seco os valores para dois pontos foram excedidos. Para Ni e Zn em apenas alguns pontos foram observados valores acima do permitido. A metodologia aplicada foi eficiente porque permitiu a determinação dos metais a níveis exigidos pela legislação brasileira. As concentrações dos metais foram superiores aos valores máximos permissíveis estabelecidos pela legislação vigente para vários elementos tanto nas amostras de água quanto nas amostras de sedimento. Os resultados apontam para a necessidade de ações para recuperar a qualidade dos mananciais bem como protegê-los de novas alterações antrópicas negativas.
Palavras Chave: Metais pesado, Água ¿ Qualidade, Sedimentos, Poluição -- Aspectos Ambientais, Meio ambiente, Fluorescência de raio X, Síncrotron / Abstract: The city of Limeira is located in the State of São Paulo and has expressive economy, with industries in several productive sectors, as galvanization industries for the jewels, semi-jewels and bijoux production. Aiming to explain the anthropogenic influence in the sources, the water and sediment qualities of the Graminha and Águas da Serra brooks were evaluated whose springs are in the urban zone of Limeira. The metal determination was performed using Synchrotron Radiation Total Reflection X-Ray Fluorescence (SRTXRF). The detection limits for water samples were in the range of 0.50 to 0.05 µg.L-1 for Ca and Zn, respectively while for sediment samples the detection limits were 0.22 to 0.02 µg.g-1 for the same elements. For water samples in both brooks and for all periods (dry and humid) the concentrations of Al and Fe were higher than the maximum permissive values (MPV) established by the legislation. For Zn and Cu the same behaviour was observed. For Cr and Ni just some locations presented values higher than MPV for water samples. Moreover in Águas da Serra brook values higher than MPV were observed for all points except for two points in the dry period, for Graminha 12 stream the results were higher for four sample locations in the humid period. For sediment samples Cu surpass the value established by the legislation for both springs. For Pb the values surpass the limit for all samples in Águas da Serra and some points for Graminha stream. The results for Cr in sediment samples were surpassed for three points in the humid period and two points in the dry period for Águas da Serra brook, and in Graminha just in the dry period for two points the values were exceeded. For Ni and Zn only a few points surpassed the limits for both springs.The applied methodology was efficient because the detection limits turned possible the determination of the metals in levels in according to legislation. The metal concentrations were higher than the maximum permisse values established by the Brazilian Legislation for several elements in water and sediment samples. The results point to the action necessity to recover the quality of the sources as well as to protect the brooks of new negative anthropogenic alterations.
Keywords: Heavy metals, Water quality, Sediment, Pollution, Environment, Synchrotron Radiation Total Reflection X-Ray Fluorescence (SR-TXRF) / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258642
Date29 August 2007
CreatorsFazza, Elizete Vieira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Moreira, Silvana, 1957-, Nour, Edson Aparecido Abdul, Vives, Ana Elisa Sirito de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format168p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0141 seconds