Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:35:30Z (GMT). No. of bitstreams: 1
325537.pdf: 2029115 bytes, checksum: dfcdac0cf969ec71a28f21b8f87903e5 (MD5)
Previous issue date: 2013 / Objetivo: Avaliar as alterações dentárias imediatas de inclinação, altura e espessura alveolar na região de molares após a expansão maxilar com o aparelho Quadrihélice por meio de Tomografia Computadorizada de Feixe Cônico. Metodologia: A amostra foi composta por 24 pacientes que utilizaram o aparelho Quadrihélice, com uma ativação mensal de 2mm durante 4 meses, totalizando 8mm de expansão, com mais 2 meses de contenção. As imagens de Tomografia computadorizada de Feixe Cônico (TCFC) foram realizadas no início (T1) e após a contenção de dois meses (T2). Os dados foram obtidos através do método padronizado de análise de imagens e manipulados pelo programa Osirix Medical Imaging Software 32-bit. O teste estatístico utilizado para verificar se havia diferenças entre as médias foi o teste "t" para dados pareados. Resultados: Foi observada redução média na espessura óssea alveolar de 0,57mm e perda óssea vertical média de 0,25mm. A inclinação dos molares para vestibular ocorreu, com um aumento médio de 14o. Conclusões: O Quadrihélice mostrou-se eficiente, mas apresentou perdas ósseas que precisam ser consideradas, realçando que se deve controlar a inclinação vestibular dos molares para se obter um melhor resultado.<br> / Abstract : Objective: To evaluate immediate dental tip, height and thickness of alveolar molar region after maxillary expansion appliance with Quad-helix through Cone Beam Computed Tomography. Methods: The sample consisted of 24 patients who used the device Quad-helix activation with a 2mm monthly for 4 months, reaching 8mm expansion, with over two months of contention. Images of beam computed tomography (CBCT) were performed at baseline (T1) and after retention of two months (T2). Data were obtained through standardized method of image analysis and manipulated by the program OsiriX Medical Imaging Software 32 - bit. The statistical test used to check if there were differences between the means was the "t" test for paired data. Results: There was a mean reduction in alveolar bone thickness of 0,57mm and average vertical bone loss of 0,25mm. The inclination of the molars buccally occurred, with an average increase of 14o. Conclusions: the Quad-Helix was efficient, but showed bone loss that must be considered, stressing that it must control the buccal inclination of molars to obtain better result.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/122950 |
Date | January 2013 |
Creators | Floriano, Gilberto |
Contributors | Universidade Federal de Santa Catarina, Ribeiro, Gerson Luiz Ulema |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 157 p.| il., grafs., tabs. |
Source | reponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.002 seconds